Ohio s Used Oil Regulations for Generators

Similar documents
Subpart A - Definitions. Subpart B - Applicability

Recycling Used Oil in New Jersey. Sondra Flite, Principal Environmental Specialist NJ Department of Environmental Protection

Subpart D_Standards for Used Oil Collection Centers and Aggregation Points. Subpart E_Standards for Used Oil Transporter and Transfer Facilities

Environmental Management Chapter ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT LAND DIVISION - HAZARDOUS WASTE PROGRAM ADMINISTRATIVE CODE

John Benson David Hanny Barton & Loguidice, P.C.

Florida Department of Environmental Protection

1) Activity Description: Management of Petroleum Storage Tanks and Containers

Ohio Specific Universal Waste

Lecture 11 Used Oil. 1. Introduction 12/19/2012

Preventing Leaks and Spills at Service Stations. A Guide for Facilities

Spill Prevention, Control, and Countermeasure. Training Module

FORT RUCKER Environmental Management System

Title: Jet Engine Test Cell

Department of the Environment

RULE LIQUEFIED PETROLEUM GAS TRANSFER OR DISPENSING (Adopted 1/13/2015)

SECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)

What is Oil? {and what it s not} 15 th Annual OSC Readiness Training Program.

Background. AEM Tier 2 Worksheet Petroleum and Oil Product Storage. Glossary. Agricultural Water Quality Principle:

Draining and Filling Cooling System

SLUG CONTROL PLAN. Section A - Spills from Water-Using Process Areas

2011 STORM WATER POLLUTION PREVENTION PLAN ANNUAL UPDATE QUESTIONNAIRE

Form A STORM WATER POLLUTION PREVENTION PLAN ANNUAL UPDATE QUESTIONNAIRE

Georgia Drycleaner Compliance Calendar

SEPA Statement Processed Fuel Oil

EJIF Municipal Inspection Checklist

Safe Operating Procedure

Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations

PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION

Safe Operating Procedure

Safe Operating Procedure

ES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number

B2. Fueling Operations

Michigan Business Pollution Prevention Program

New Ultra Low Sulfur Diesel fuel and new engines and vehicles with advanced emissions control systems offer significant air quality improvement.

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

USES FOR RECYCLED OIL

TIME TASK FORCE. Guidelines for the Mitigation of Motor Vehicle Fluid Spills at Crash Scenes (Non-Cargo)

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

Tests conducted under the following industry standards for PermaFrost API ASHRAE ARI ASTM EPA ANSI UL. SINCE 1985 Quality Controlled Through Analysis

Vehicle and Equipment Fueling

SPILL PREVENTION CONTROL AND COUNTERMEASURES PLAN (SPCCP) FOR FUELING AT STATION 63

Where s the Waste?, and Where are you Storing It? Stephan Szardenings, CHMM

What is the secret to INOV8 s Burner Technology?

Basic Guidance for the Production/Blending of Biodiesel Product and Complying with Applicable Code

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

Guidelines For the MITIGATION OF ACCIDENTAL DISCHARGES OF MOTOR VEHICLE FLUIDS (NON-CARGO) APPROVED 6/25/04

Pennsylvania DEP Aboveground Storage Tank Facility Visits NISTM PA CONFERENCE Washington, PA May 18, 2017

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids.

Fact Sheet #4 Reducing the Risk of Groundwater Contamination by Improving Petroleum Product Storage

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Dry Cleaner Compliance Calendar 2015

Fuel Storage Dec 2016

Electrical Power Generator Use and Procurement Guidance

EJIF Municipal Inspection Checklist

Update for Ohio BUSTR Class A and B UST Operator Training New regulations UST operations. Robert J May PE Synergy Environmental April 2018

AIR POLLUTION CONTROL REGULATION NO. 20 BURNING OF ALTERNATIVE FUELS

Storage Tank Risk Management Solutions Leak

RULE NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016)

Example Petition for Exemption

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

YOUR SPCC PROGRAM: A CHECK UP

State of New Jersey. Department of Environmental Protection Air Quality Permitting

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

Container Management ASTSWMO. Conference & Training

BODY BUILDER INSTRUCTIONS Mack Trucks

ECM environmental compliance monitoring, inc. 1

UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL NO. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS

THE ENVIRONMENT PROTECTION ACT Regulations made by the Minister under section 96 of the Environment Protection Act 2002

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

Fuel Oil Conversions. Association of Energy Engineers (AEE) September 20, 2011

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009

TRADE EXPERIENCE LOG BOOK CANADIAN PETROLEUM CONTRACTORS ASSOCIATION. Petroleum Mechanic Training & Certification

1.1 Unless otherwise stated, the specification references and test methods are from the latest version in effect at the time of this contract.

OPERATIONS AND MAINTENANCE PLAN

TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00)

6/15/2010. Environmental Auditing. Who Sponsors the Audits? Auditing Rationale. Birdsall Services Group (BSG-PMK) Rule of Self-Insured

A Closer Look at ULSD. Mahesh Albuquerque Director

Follow Up on the Final Decision on the Assessment of Releases of Used Crankcase Oils to the Environment

BRITISH COLUMBIA USED OIL MANAGEMENT ASSOCIATION

Air Permitting: Municipal Facilities with Emergency Generators

Environmental Controls in ROWs and Available Cleanup Funding Programs

OWS OPERATIONS & MAINTENANCE

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

Lorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA

Unit D: Agricultural Equipment Systems. Lesson 1: Understanding Applications of Fluids and Lubricants in Agricultural Equipment

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

P.O. Box 435 Saratoga Springs, NY 12866

MODULAR USED LUBE OIL RE-REFINING

Fats Oils and Grease (FOG) Program Workshop. JEA Industrial Pretreatment Program August 2004

COMMERCIAL ITEM DESCRIPTION DRY CLEANING AND DEGREASING SOLVENT, PD680

This rule shall apply to any stationary source which is a major source of regulated air pollutants or of hazardous air pollutants.

Title: Aircraft Parts Replacement

SPCC Regulation Integrity and Leak Testing Methods

40 CFR 63, Subpart CCCCCC

Waste Lubricating Oil Purification and Recovery

Automotive Service Service Stations

Draining and Filling Cooling System

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

Transcription:

Ohio s Used Oil Regulations for Generators Dan Sowry Office of Compliance Assistance & Pollution Prevention January 29 th, 2013

What we will cover Definition Generator responsibilities On-site management Spills/releases Management options Burning in space heater Used oil filters Do s and Don ts Resources

What is Used Oil? Must meet three criteria: Origin Refined from crude oil or synthetic-based Use lubricant, hydraulic fluid, heat transfer (coolant), cutting fluid Contaminated Physical or chemical impurities Examples: dirt, metal shavings, solvents

Examples of Used Oil engine oils from vehicles and equipment lubricating oil brake/transmission fluids hydraulic fluids insulating oils metal cutting fluids industrial process oils compressor or refrigerant oil

Used Oil Does Not Include oil products (unused/new) cleanup material from oil product spills animal/vegetable oil sludge from virgin oil storage tanks antifreeze kerosene (unless used for lubricating purposes) petroleum distillate solvents gasoline, diesel fuel oily waste water

What is a used oil generator? Used oil generator: the 1 st person whose action or process 1 st causes used oil to become subject to regulation. Different types of businesses generate used oil: Manufacturing companies Machine shops Metal working industries Auto service stations Quick lube shops

Additional used oil rules Based on your activities you may also be subject to other used oil rules including: Transporting Collecting from other businesses/homeowners Re-refining or reprocessing Burning Marketing Where to go for more information? epa.state.oh.us/dmwm/home/usedoil2.aspx

Regulation under other programs? Spill Prevention Control and Countermeasures (SPCC) A total aboveground storage capacity of 1,320 gallons; or More than 42,000 gallons of underground storage capacity epa.ohio.gov/portals/41/sb/publications/spcc.pdf Bureau of Underground Storage Tank Regulation (BUSTR) If you store used oil in an underground storage tank, you may have additional requirements. Contact BUSTR at 614-752-7938 or visit their Web page at com.ohio.gov/fire/bustmain.aspx

What are your used oil generator responsibilities? Labeling Storing Releases/Spills Transporting Mixing

Labeling Used Oil Containers and Tanks Containers and aboveground tanks must be clearly labeled with the words, Used Oil

Storing used oil Containers and tanks must be in good condition (not rusting, leaking, etc.)

Responding to releases/spills If there is a leak or spill of used oil: stop the leak, contain it, clean it up, and manage the clean-up materials properly.

Transporting used oil Must use a transporter with an EPA identification number when shipping used oil off-site. Three exceptions: You are transporting less than 55-gallons of used oil on-site; You are the generator of the used oil and are transporting less than 55-gallons to a collection center or aggregation point; or Tolling agreement Contractual agreement to reclaim and return oil to be reused by generator

Mixing used oil You can mix other wastes with your used oil, but it could cause problems: Mixture is often considered hazardous waste May no longer be able to manage as used oil May increase your management and disposal costs

Used oil mixing exceptions CESQGs can mix their used oil and hazardous waste and manage as used oil HOWEVER may not be accepted by used oil processors, re-refiners, or burners Used oil mixed with hazardous waste that is only ignitable (D001) can be managed as used oil if the resulting mixture is not ignitable Must analyze to prove this Used oil mixed with hazardous waste that is corrosive, reactive or TCLP toxic can be managed as used oil if the mixture does not exhibit any characteristic. Must analyze to prove this

Rebuttable presumption This applies to all used oil Used oil with >1000 ppm total halogens (Chlorine, Fluorine, Bromine compounds) is presumed to be mixed with halogenated hazardous waste You may rebut the presumption by: Demonstrating that the oil is from a CESQG Demonstrating that it contains insignificant levels of halogenated hazardous constituents Demonstrating that they are cutting or machining oils containing chlorinated paraffins that are reclaimed under a tolling agreement epa.ohio.gov/portals/32/pdf/usedoilburnerguidance.pdf

Used oil management options Take to a registered collection center Use company or employee owned vehicle and no more than 55-gallons so used oil transporter rules do not apply epa.ohio.gov/portals/32/pdf/used%20oil%20collection%20centers%20list.pdf Take to aggregation point(s) Aggregation point is a site you own that you take used oil to Use company or employee owned vehicle and no more than 55-gallons so used oil transporter rules do not apply Burn your used oil in your space heater Pick-up by used oil recycler Reconditioning Re-refining Reusing Burning for energy recovery in boiler, industrial furnace or space heater epawebapps.epa.state.oh.us/recyclers/jsp/results.jsp?category=17

Sending your used oil to a Burner If you send used oil directly to a company that will be burning for energy recovery, you are a used oil marketer. Used oil marketer must: Obtain U.S. EPA identification # (unless you already have one) Maintain records Name/Address of transporter and burner U.S. EPA ID # of transporter and burner Quantity and date shipped Obtain/retain certification Must be done before 1 st shipment Written notice from burner must state: Burner has notified Ohio EPA Burner will only burn in boiler or industrial furnace Retain certification for 3 years on-site

Sending used oil to another business to be burned in a space heater Must meet the following: Obtain EPA identification number (unless you already have one) Keep records the name of the receiving facility; the quantity of used oil delivered; the date of shipment or delivery; and, a cross-reference to the analysis or information that demonstrates that it meets the specification. Determine if the used oil contains greater than 1,000 ppm total halogens, and be able to rebut the presumption Must be on-specification used oil All used oil is presumed to be off-specification until otherwise demonstrated. Therefore you cannot mix multiple shipments and then test the used oil.

On-specification used oil Used Oil Specification Constituent / Property Maximum Allowable Level (total concentration) Arsenic 5 ppm Cadmium 2 ppm Chromium 10 ppm Lead 100 ppm Flash Point 100º F minimum Total Halogens 4,000 ppm* *Although the used oil specification s total halogen regulatory limit is 4,000 ppm, if the total halogens exceed 1,000 ppm Ohio EPA presumes the used oil has been mixed with a hazardous waste, unless you can prove that it hasn t.

Space heaters must Be vented to the outside; Have a heating capacity of 500,000 BTU/hr or less; and Be legitimately used for heating purposes such as for comfort in homes, workspaces or garages or for other heating purposes such as in a greenhouse.

Used oil filters Two filter types: Terne plated Heavy duty vehicles May be hazardous for lead Hot drain and recycle as scrap metal to avoid HW rules Non-terne plated Light duty vehicles Hot drain and can be disposed in regular trash Strongly recommend recycling as scrap metal epawebapps.epa.state.oh.us/recyclers/jsp/results.jsp?category=18

Do s and Don ts DO inspect equipment for oil leaks and take quick actions if repairs are needed DO train personnel on the correct methods for handling used oil DO look for ways to reduce the amount of used oil waste that your business generates

DON T do this!

DON T do this!

DON T pour used oil into a sewer, floor drain or a storm drain! The oil from a single oil change (1 gallon) can ruin the taste of a million gallons of drinking water, the supply of 50 people for one year. Not only does this cause environmental damage, it can also lead to violations or penalties.

DON T use used oil outside on the ground for any reason! epawebapps.epa.state.oh.us/recyclers/jsp/results.jsp?category=31

DON T mix other wastes with used oil!

Resources Ohio EPA s Used Oil Web page epa.state.oh.us/dmwm/home/usedoil2.aspx Ohio EPA s Used Oil Forms epa.ohio.gov/dmwm/home/nonhwforms.aspx Used Oil Generator Guidance epa.state.oh.us/portals/32/pdf/used_oil_generators_guidance.pdf EPA Identification Number Form epa.state.oh.us/dmwm/home/notiform.aspx Used Oil Requirements Summary Table epa.state.oh.us/portals/32/pdf/usedoilrequirementstable.pdf

Questions? OCAPP: 1-800-329-7518 Free and confidential hotline Dan Sowry Central Ohio OCAPP Representative 614-728-8575 dan.sowry@epa.ohio.gov