Library Product Section Product Model Literature Type Sequence Date File No. Supersedes

Similar documents
Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

ECONOMIZERS. 1/2012 Supersedes

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

ECONOMIZERS. 5/2012 Supersedes

Package Unit Modulating Economizer Installation Instructions

Installation Instructions

Installation Instructions

Package Unit Modulating Economizer Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

Installation Instructions

Installation Instructions

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

INSTALLATION INSTRUCTIONS

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

Installation Instructions

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

LF Series At A Glance

INSTALLATION INSTRUCTIONS MODELS (-)XRD-MCCM3 & (-)XRD-MECM3/TECM3 CONVERTIBLE AIRFLOW ECONOMIZERS

N-1001 Economizer Logic Network

INSTALLATION INSTRUCTION

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

R81EAA-2 Economizer Circuit Board

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS MODELS (-)XRD-PDCM3 & (-)XRD-SDCM3 VERTICAL AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

Metasys Zoning Package Installation

Installation Instructions

Installation Instructions

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

Remote Temperature Controllers. Quick Selection Guide

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

MA-5200 Series MA-5300 Series

MicroMetl. INSTALLATION INSTRUCTIONS Dual Stage Relief Economizer ECD-SRT12DR, ECD-SRT34DR, ECD-SRT5SDR & ECD-SRT5LDR

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

Voyager Microcontrols

YCCS TE-6800 Series Temperature Sensors

INSTALLATION INSTRUCTIONS MODELS (-)XRD-RGCM3 HORIZONTAL AIRFLOW ECONOMIZERS

Product Data. Single Packaged Gas/Electric 15 SEER Convertible, 2 5 Ton A-EN. July 2016

Discharge Air Control

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION & MAINTENANCE MANUAL BYPASS ECONOMIZER OPTION

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION FEATURES

CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

System 350 S350P Proportional Plus Integral Temperature Stage Module

Terms. Direct Acting (DA) The action of a controller that increases its branch line pressure as the controlled variable increases

System 350 P352AB Electronic Pressure Control Series

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

General Information... 2

TC62D Installation Instructions

INSTRUCTIONS FOR (-)XRX-AW04 or (-)XRX-AW05 MOTORIZED FRESH AIR DAMPER KIT

LOW AMBIENT ACCESSORY INSTALLATION INSTRUCTION

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing

G600 Series Replacement Intermittent Pilot Ignition Controls

Damper Actuator Installation

INSTALLATION INSTRUCTIONS

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

Factory Option Codes L M E S P R D V F F H E

TS Series TS Series

SLIMZONE CLASSIC /

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

ENERGY RECOVERY SYSTEM 60 HZ

Installers Guide. Trane Communications Interface ( Comm3 / Comm4 )

Metasys Zoning Package

WARNING IMPORTANT

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

G76x Direct Spark Ignition Controls

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Installation Instructions

SINGLE PACKAGE HEAT PUMPS

Transcription:

INSTALLER'S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES. Library Product Section Product Model Literature Type Sequence Date File No. Supersedes ACC-SVN85B-EN Service Literature Unitary Unitary Accessories Econ., Dmprs., Motors, Low Ambient Installer's Guide January 2008 ACC-SVN85B-EN 0/08 ACC-SVN85A-EN /06 Model: BAYENTH00A Used With: BAYECON054,55&73 BAYECON086A,088A BAYECON0,02,03,04A BAYECON200,20,203,204A Enthalpy Sensor Control IMPORTANT -- This is customer property and is to remain with this unit. Please return to service information pack upon completion of work. Installation For BAYECON054,055 Downflow Discharge Economizer: WARNING: TO PREVENT INJURY OR DEATH DUE TO ELECTRICAL SHOCK OR CONTACT WITH MOVING PARTS. LOCK UNIT DISCONNECT SWITCH IN OPEN POSITION BEFORE SERVICING UNIT. Single Enthalpy Sensor (Outdoor Air Only) General Information: The solid state enthalpy sensor is used with a solid state economizer actuator motor. Contents General Information... BAYECON054,055 (Downflow)... Differential... 2 BAYECON073 (Horizontal)... 3 Differential... 3 BAYECON086,088 (Downflow)... 4 Differential... 4 BAYECON086,088 (Horizontal)... 5 Differential... 5 BAYECON0,02,03,04 (Downflow)... 6 BAYECON200,20,203,204 (Horizontal)... 7 Operation (All Economizers)... 8 Checkout/Troubleshooting... 9 Wiring (054,055,086,088)... 0 Wiring (0,02,03,04)... Wiring (200,20,203,204)... 2. Units with economizers already installed: When installing the enthalpy sensor after the economizer has been installed remove the economizer/filter access panel located on the return side of the unit. 2. Remove the two screws securing the disk type thermostat to the top of the motor deck. 3. Next, disconnect the wires 56A and 50A(YL) from the thermostat. 2 SINGLE ENTHALPHY SENSOR Trane 2008

4. Using the two screws removed in step 2, mount the Enthalpy sensor in the thermostat's previous location, see figure 2. 5. Connect wire 56A to S and 50A(YL) to terminals on the Enthalpy Sensor. 6. On the Control Module (Solid State Economizer Logic Module) attached to the Economizer Motor, remove the red resistor from terminals and and discard. See figure 4. 4 Control Module before Installation W7459D A B C TR S O D TR 2 (R) RED 750 OHM JUMPER (R4) WHITE 620 OHM JUMPER S DISK TYPE THERMOSTAT 7. Remove the white resistor from between the S O terminal and wire 56A. Than install the white resistor across the and terminals MIN. POS. OPEN LED LIGHTS WHEN OUTDOOR AIR IS SUITABLE FOR FREE COOLING 8. Install the terminal adaptor provided with the sensor on terminal S O of the Control Module and connect wire 56A to it. 9. Replace the economizer/filter access panel. Installation for Differential Enthalpy Sensing (Outside Air & Return Air). Complete the procedures for installing a single enthalpy sensor. 2. Mount the second enthalpy sensor on the bottom side of the motor deck, see figure 3. 5 W7459D A B C TR S O D TR M9097_W/O Control Module with One Enthalpy Sensor ENTHALPY CHANGEOVER SETPOINT C7400 (R4) WHITE 620 OHM JUMPER S 3. Remove the knockout located below the Economizer Motor and insert a snap bushing. 4. Install field supplied wires through the snap bushing MIN. POS. OPEN LED LIGHTS WHEN OUTDOOR AIR IS SUITABLE FOR FREE COOLING 3 6 M9097 JUMPER USED FOR SINGLE ENTHALPY CONTROL. Control Module with Two Enthalpy Sensors W7459D A B C TR S O D TR ENTHALPY CHANGEOVER SETPOINT C7400 S S C7400 DIFFERENTIAL ENTHALPY SENSOR MIN. POS. OPEN LED LIGHTS WHEN OUTDOOR AIR IS SUITABLE FOR FREE COOLING SCREWS M9097_2_ page 2

Installation for BAYECON073 Horizontial Discharge Economizer: INSTALLER'S GUIDE Single Enthalpy Sensor (Outdoor Air Only). Units with economizers already installed: When installing the enthalpy sensor after the economizer has been installed remove the economizer rain hood. 2. Remove the two screws securing the disk type thermostat on the damper side of the economizer. 3. Next, disconnect the wires 56A and 50A(YL) from the thermostat. 4. Using the two screws removed in step 2, mount the Enthalpy sensor on the outside face of the economizer. See figure below. 5. Connect wire 56A to S and 50A(YL) to terminal on the Enthalpy sensor. 6. Remove the filter access panel on the return side of the unit reach into the Control Module attached to the Economizer Motor, remove the red resistor from terminals and and discard. See figure 4. 7. Remove the white resistor from between the S O terminal and wire 56A. Than install the white resistor across the and terminals 8. Install the terminal adaptor provided with the sensor on terminal S O of the Control Module and connect wire 56A to it. 9. Reinstall the rain hood and filter access panel. Installation for Differential Enthalpy Sensing. Complete the procedures for installing a single enthalpy sensor. 2. Mount the second enthalpy sensor in the return air stream. See figure below. 4. Install field supplied wires through from terminals S and on the return enthalpy sensor to the and terminals on the Control Module. 6. On the Control Module (Solid State Economizer Logic Module) attached to the Economizer Motor, remove the white resistor from between the terminal and the terminal. Then connect the wire from S on the sensor to on the Control Module and on the sensor to on the Control Module. 7 66584 page 3

Installation for BAYECON086A, BAYECON088A Downflow Discharge Single Enthalpy Sensor (Outdoor Air Only). Units with economizers already installed: When installing the enthalpy sensor after the economizer has been installed remove the economizer/filter access panel located on the front side of the unit. Remove the mist eliminator and retaining angle from the economizer. 2. Remove the two screws securing the disk type thermostat to the rear panel. 3. Disconnect the wires 82A(YL) and 83A(YL) from the thermostat. 4. Locate bushing supplied with kit and pull wires 82A(YL) and 83A(YL) through bushing. Snap bushing into the hole where the thermostat was removed. 5. Connect wire 82A(YL) to S and 83A(YL) to terminals on the Enthalpy Sensor. 6. Using the two screws removed in step 2, mount the Enthalpy sensor ajacent to thermostat s previous location, Engagement holes are provided. 7. On the Control Module (Solid State Economizer Logic Module) attached to the Economizer Motor, remove the red resistor from terminals SR and and discard. See figure 4. 8 8. Remove the white resistor from between the SO terminal and wire 82A(YL). Then install the white resistor across the SR and terminals 9. Install the terminal adaptor provided with the sensor on terminal SO of the Control Module and connect wire 82A(YL) to it. 0. Replace the economizer/filter access panel and mist eliminator. Installation for Differential Enthalpy Sensing (Two Sensors). Complete the procedures for installing a single enthalpy sensor. 2. Mount the second enthalpy sensor on the bottom side of the Return Air Bolckoff. 3. Remove the knock-out located near the front side of the Return Air Bolckoff and insert a snap bushing. 4. Install field supplied wires through the snap bushing from terminals S and on the return enthalpy sensor to the SR and terminals on the Control Module. 5. On the Control Module attached to the Economizer Motor, remove the white resistor from between the SR terminal and the terminal and discard. Then connect the wire from S on the sensor to SR on the Control Module and on the sensor to on the Control Module. page 4

Installation for BAYECON086A, BAYECON088A Horizontal Discharge Single Enthalpy Sensor (Outdoor Air Only). Units with economizers already installed: When installing the enthalpy sensor after the economizer has been installed remove the economizer/filter access panel located on the front side of the unit. Remove the mist eliminator and retaining angle from the economizer. 2. Remove the two screws securing the disk type thermostat to the rear panel. 3. Disconnect the wires 82A(YL) and 83A(YL) from the thermostat. 4. Locate bushing supplied with kit and pull wires 82A and 83A) through bushing. Snap bushing into the hole where the thermostat was removed. 5. Connect wire 82A to S and 83A to terminals on the Enthalpy Sensor. 6. Using the two screws removed in step 2, mount the Enthalpy sensor ajacent to thermostat s previous location, Engagement holes are provided. 7. On the Control Module (Solid State Economizer Logic Module) attached to the Economizer Motor, remove the red resistor from terminals SR and and discard. 8. Remove the white resistor from between the SO terminal and wire 82A. Then install the white resistor across the SR and terminals 9. Install the terminal adapter provided with the sensor on terminal SO of the Control Module and connect wire 82a to it. 0. Replace the economizer/filter access panel and mist eliminator. Installation for Differential Enthalpy Sensing (Two Sensors). Complete the procedures for installing a single enthalpy sensor. 2. Mount the second enthalpy sensor on the side of the return air hood 3. Remove the knock-out located near the front side of the Return Air Bolckoff and insert a snap bushing. 4. Install field supplied wires through the snap bushing from terminals S and on the return enthalpy sensor to the SR and terminals on the Control Module. 5. On the Control Module attached to the Economizer Motor, remove the white resistor from between the SR terminal and the terminal and discard. Then connect the wire from S on the sensor to SR on the Control Module and on the sensor to on the Control Module. 9 page 5

Installation for BAYECON0, BAYECON02, BAYECON03, BAYECON04A Down Discharge Single Enthalpy Sensor Control (Outdoor Air Only). Units with economizers already installed: When installing the Enthalpy Sensor Control (ESC) after the economizer has been installed remove the COIL ACCESS panel. Remove the mist eliminator. 2. Remove the two screws securing the outdoor air sensor (OAS) to the rear panel. 3. Disconnect the YL/BK and YL wires from the OAS. 4. Retain the screws for later use and discard the OAS removed in steps 2 & 3. 5. Using the two screws removed in step 2, mount the ESC adjacent to the previous location of the OAS. Engagement holes are provided. 6. Connect the YL/BK wire to S and the YL wire to terminal on enthalpy sensor. 7. Reinstall the mist eliminator. 8. On the Control Module (Solid State Economizer Logic Module) attached to the Economizer Motor, remove the red resistor from terminals and and discard. See figure 4. 9. Remove the white resistor from between the S O terminal and wire 56A. Then install the white resistor across the and terminals 0. Install the terminal adaptor provided with the sensor on terminal S O of the Control Module and connect wire 56A to it. 0 page 6

Installation for BAYECON200, BAYECON20, BAYECON203, BAYECON204A Horizontal Discharge Single Enthalpy Sensor (Outdoor Air Only). Units with economizers already installed: Remove hood from economizer to access outdoor air sensor (OSA) and install Enthalpy Sensor Control (ESC). Remove COIL ACCESS panel to access Control Module (Solid State Economizer Logic Module). 2. Remove the two screws securing the OSA to the economizer. 3. Disconnect the YL/BK and YL wires from the OSA. 4. Retain the screws for later use and discard the OSA removed in steps 2 & 3. 9. On the Control Module attached to the Economizer Motor, remove the red resister from terminals S(R) and and discard. 0. Remove the white resistor from between the S(O) terminal and wire 56A. Then install the white resistor across the S(R) and terminals.. Install the terminal adaptor provided with the sensor on terminal S(O) of the Control Module and connect wire 56A to it. 5. Install ESC on mounting bracket located in the upper corner of the hood using the screws removed in step 2. 6. Re-install hood on economizer. 7. Remove top mist eliminator in hood and connect the YL/BK wire to S and the YL wire to terminal on ESC. 8. Re-install mist eliminator into hood. q Economizer Hood Mounting Bracket Printed from D7452G0 page 7

Operation (All Economizers) Controller Dial Setting Control set point scale is located on the Control Module, see Figure 4 on page 2. Control points A, B, C, D are field selectable, and are used for single enthalpy sensing. The Solid State Enthalpy Sensor is used with a solid state economizer control and damper actuator to proportion an outdoor air damper in a ventilation system. When using a single enthalpy control setpoint A, B, C, or D combines temperature and humidity conditions resulting in the control curve shown on the psychrometric chart below. When the enthalpy of the outdoor air is below (left of) the appropriate curve, the outdoor air damper can proportion open on a call for cooling. If the outdoor air enthalpy rises above (right of) the control curve, the outdoor air damper will close to minimum position. For differential enthalpy, you must turn the control set point past D (fully clockwise). Differential enthalpy is not available for 0,02,03,04 Economizers. If the outdoor air enthalpy is lower than the return air enthalpy, the outdoor air damper will proportion open on a call for cooling. If the outdoor air enthalpy is higher than the return air enthalpy, the outdoor air damper will close to minimum position. If the outdoor air enthalpy and return air enthalpy are equal, the outdoor air damper will proportion open on a call for cooling. q CONTROL CONTROL POINT CURVE APPROX. F ( C) AT 50% RH A 73 (23) B 70 (2) C 67 (9) D 63 (7) ENTHALPY BTU PER POUND DRY AIR 00 90 2 4 6 8 20 22 24 26 28 30 32 34 36 38 40 42 44 46 35 (2) 40 (4) 45 (7) 50 (0) D 60 (6) A 55 (3) B C 65 (8) 70 (2) 75 (24) 80 70 80 (27) 60 50 85 (29) 40 90 (32) 30 95 (35) 20 00 (38) RELATIVE HUMIDITY (%) 05 (4) 0 (43) 0 D C B A 35 (2) 40 (4) 45 (7) 50 (0) 55 (3) 60 (6) 65 (8) 70 (2) 75 (24) 80 (27) APPROXIMATE DRY BULB TEMPERATURE F ( C) HIGH LIMIT CURVE FOR W7459D. 85 (29) 90 (32) 95 (35) 00 (38) 05 (4) M68 0 (43) page 8

Checkout and Troubleshooting Checkout Procedure for Single Sensor Response A. Make sure enthalpy sensor is connected to SO and. The white resistor must be placed on SR and.. Turn enthalpy set point on Economizer Logic Module to A 2. With power connected, spray a small amount of envronmentally safe coolant in upper left vent of sensor to simulate low enthalpy conditions. (See figure 2) B. Disconnect power at TR and TR. ) LED (light -emitting diode) turns on within a minute. 2) Terminals 2, 3 closed. Terminals, 2 open Terminals 2, 3 open. Terminals, 2 closed. Checkout procedure for Differential Enthalpy (Second enthalpy sensor connected to terminals SR and ) A.. Turn enthalpy set point on Economizer Logic Module past D (full clockwise). 2. With power connected, spray a small amount of environmentally safe coolant into upper left vent of sensor connected to SO and to simulate low outdoor air enthalpy. (See figure 2). B. Spray small amount of environmmentally safe coolant in upper left vent of return air enthalpy sensor connected to SR and to simulate low return air enthalpy. ) LED turns off. 2) Terminals 2, 3 closed. Terminals, 2 open. ) LED turns off. 2) Terminals 2, 3 open. Terminals, 2 closed. w SPRAY SMALL AMOUNT OF COOLANT INTO UPPER LEFT CORNER VENT OF ENTHALPY SENSOR CASE TO SIMULATE LOW ENTHALPY FOR CHECKOUT. ENTHALPY SENSOR S ENVIRONMENTALLY SAFE COOLANT, SUCH AS ENVI-RO-TECH 672-0S M263 page 9

Enthalpy Sensor Wiring When Used With BAYECON054,055 & 73 BAYECON086A,088A ECONOMIZER W/OPTIONAL OUTDOOR ENTHALPY SENSOR (82A) (83A) (GREEN) Installer Note: Please Check Installed Option ECONOMIZER W/OPTIONAL DIFFERENTIAL ENTHALPY SENSORS (82A) (83A) page 0

Enthalpy Sensor Wiring When Used With BAYECON00,02,03,04,200,20,203,204 INSTALLER'S GUIDE ECONOMIZER W/OPTIONAL OUTDOOR ENTHALPY SENSOR (YL/BK) (GREEN) The manufacturer has a policy of continuous product improvement, and it reserves the right to change specifications and design without notice. page