C3000 SIGNAL TRANSMITTER. Introduction

Similar documents
CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

MAXIGARD A2000 SPEED SWITCH. Introduction

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

A5000GEC-24VDC ZERO SPEED SWITCH

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Electric Actuator Installation, Operation & Maintenance Manual

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81)

Boston Gear Ratiotrol DC Motor Speed Control

SG1000A Slide Gate Sensor Slide Gate & Valve Position

Air Curtain. Installation, Operating and Maintenance Instructions

Model 116 DPI Switch Installation and Operating Instructions

BEAMER Tilt Beam Sensor

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM. User Guide Quality Industrial Weighing and Force Measurement Equipment

Model 616 Rotating Disk Electrode Instruction Manual

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Installation and Operating Manual

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

LU27 Series Quick Start

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

HYGRODYNAMICS DEW POINT MONITOR MODEL 8092P 8092P-230VAC TABLE OF CONTENTS DIAGRAMS

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

CAP ANALOG 4100 INSTALLATION & OPERATION MANAUL

SETRA Operating Instructions Series DPT 230 Pressure Transducers

OWNERS MANUAL JANUARY 2007 ISO

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

TTH-1315 TTH-1315-A Temperature & Humidity Sensor User s Manual

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

Installation and Set Up Instructions

PRODUCT INFORMATION BULLETIN

MAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

ROD HOLDER & DOWNRIGGER TROLLING SYSTEM

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

Web Volume Control Model WV220

RK Standby Battery Operator s Manual

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator

VICTORY TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Kompensator External Low Voltage Heating Cable System

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

LNW-5. Installation... 2 Lift Truck Conditions Indicator Installation Hose Installation

Kitchen Tech Series Air Curtain

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

BMRX Series ROTARY LEVEL CONTROL

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

XP88 & XP89 Series Quick Start

Installation Instructions Soft Top Replacement Hardware, Wrangler

ADI-125/750 ADI-125/1500 ADI-125/2500

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

1100 Series Piston Type Differential Pressure Gauges

SAFTRONICS DF8 PLUS SERIES

RK Standby Battery Operator s Manual

Installation and Set Up Instructions

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

EchoPod. Technical Support. Model: DL14-(XX) Quick Start

BLWS23MDAxS-160 Offline Series 110VAC, 3A Brushless Controller / Motor

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

WEB CONTROL PRODUCTS

OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

TB Series Brakes Tension Control System

TRAC-3 TENSION READOUT AND CONTROL

SPC-PANEL Simplex, Single Phase Pump Control Panel

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Tracer VM with User Interface

Harvil 4 Foot Air Hockey Table

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

INSTALLATION/OPERATING INSTRUCTIONS TSC

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Shaft Speed Switches. SCP Series Speed Switch. M Series Speed Switch M100T/M5000T. Our Most Popular Speed Switch!

Filtered PWM Speed Control for Permanent Magnet DC Motors

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

Dual Linear Actuator Controller

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

Transcription:

C131-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 C3000 SIGNAL TRANSMITTER Introduction The MAXIGARD C3000 series is designed to convert shaft speed to 4-20 MA or 0-10 VDC analog outputs. The transmitters are built of quality material and completely factory tested to insure long life and trouble free operation. Principle of Operation The Maxigard C3000 Signal Transmitter has a non contact sensor and is supplied with a magnetic target. The sensor signal is not impaired by the build up of dust or any other foreign material on the magnetic target or sensing head. The C3000 is designed to convert shaft speed to analog 4-20 MA or 0-10 VDC outputs. Components THE C3000 SIGNAL TRANSMITTER INCLUDES:! 4 MAGNET DISC (OTHER OPTIONAL TARGETS AVAILABLE)! SENSING HEAD WITH MOUNTING BRACKET & 10 FEET OF CABLE! CIRCUITRY WITH 4-20 MA OR 0-10 VDC ANALOG OUTPUT! NEMA 4 ENCLOSURE (C3000) / NEMA 4X ENCLOSURE (C3000C)

C131-05, Page 2 SECTION 1 - MECHANICAL 1.0 Magnet Disc 1.1 The end of the shaft to be monitored should be square to prevent excessive disc wobble. 1.2 Center drill and tap the shaft end. (Suggested #21 drill and #10-32NF tap). Bolt the magnet disc to the end of the shaft. Use Loc-tite to keep the bolt and disc tight on the shaft. (see figure 1A & 1C, page 3). 2.0 Magnet Wrap (optional) 2.1 Separate the two halves of the magnet wrap by loosening the cap screws holding the two halves together. 2.2 Place both halves of the magnet wrap around the shaft. Re-insert and tighten the cap screws making sure the wrap is square to the shaft. (see figure 1B &1D, page 3). NOTE There will be a slight gap between the two halves after tightening. This gap will not affect the generated signal. 3.0 Mounting the Sensing Head 3.1 Place the sensing head so it is centered directly in front of the magnets in the disc or optional wrap. (see figure 1A, 1B, 1C &1D page 3). 3.2 The gap setting between the sensor and magnet disc should be approximately 1/8-7/8.

SENSING METHOD C131-05, Page 3 STANDARD SENSING HEAD & MAGNETIC DISC STANDARD SENSING HEAD & MAGNETIC WRAP 1/8" to 7/8" GAP MAGNET SENSOR MAGNET 1/8" to 7/8" GAP SENSOR MAGNET DISC Figure 1A MAGNET WRAP Figure 1B XP SENSING HEAD & MAGNETIC DISC XP SENSING HEAD & MAGNETIC WRAP 1/8" to 7/8" GAP MAGNET MAGNET 1/8" to 7/8" GAP 1 5/8" Figure 1C Figure 1D 4.0 Signal Transmitter Enclosure 4.1 The 3000 switch enclosure is UL/CSA listed, rated NEMA 4, dust tight, oil tight, and water tight, painted carbon steel suitable for indoor or outdoor use. (see figure 2A, page 4) 4.2 The C3000C switch enclosure is UL/CSA listed, rated Nema 4X corrosion resistant, dust tight, oil tight and water tight, fiberglass construction suitable for indoor or outdoor use. (see figure 2B, page 4) CAUTION Remove the circuit board from the enclosure before punching or drilling conduit holes. Be sure to remove all metal chips and filings.

C131-05, Page 4 C3000 NEMA 4 STEEL C3000C NEMA 4X FIBERGLASS 6" 3 1/2" 6 15/16" 4 1/4" 8" 8 3/4" 8 1/2" 9 1/8" 4" 5/16" 4" 5/16" Figure 2A Figure 2B 1/4" 4" DIMENSIONAL DATA 5/16" 2 1/2" 10 5/16" 2 1/2" 10 3/4" 1/2" NPS 3/4" 1/2" NPS 3/16" 1 3/8" 2" MATERIAL: RED ANODIZED ALUMINUM 1 3/8" 2" MATERIAL: PVC STANDARD MAGNET DISC STANDARD SENSING HEAD AND MOUNTING BRACKET NEMA 4X SENSING HEAD AND MOUNTING BRACKET D"+3" 3" 15/16" 2" 5/8" 5/8" 4" 5/16" X 1" 1" 2 1/2" D" 7/8" 10 OPTIONAL MAGNET WRAP XP SENSING HEAD AND MOUNTING BRACKET CALL TOLL FREE 800-328-0738 Figure 3

SECTION 2 - FIELD WIRING C131-05, Page 5 5.0 Sensing Head Wiring 5.1 Connect the sensing head cable to terminals black, white and shield located on terminal block TB2. 5.2 The sensing head comes standard with 10 of cable. Additional cable can be added as required. Be sure to maintain continuity. Wrap the splice with the foil shield and electrical tape. 6.0 Wiring the C3000 or C3000C Signal Transmitter 6.1 Connect 120 VAC power to L1 and Neutral to L2 on terminal block TB1. Connect equipment safety ground to GD on terminal block TB1. 6.2 Make analog output connections to signal output + - on terminal block TB1. 6.3 See figure 5 page 6 for typical wiring interface diagram. WARNING To avoid electrical shock disconnect all sources of power before wiring and observe voltage ratings of the C3000 Signal Conditioner. Figure 4

C131-05, Page 6 NOTE The 0-10VDC and 4-20MA outputs must be connected to isolated or differential inputs. Single ended inputs are not supported. 120VAC C3000 N SENSOR WHITE BLACK SHIELD TB2-1 TB2-2 TB2-3 TB1-L1 TB1-L2 TACHOMETER + - TB1-GD TB1 + TACHOMETER OUTPUT TB1 - TB1 - SIGNAL OUTPUT TB1 + 1 CHANNEL 1 + 2 CHANNEL 1 - DIFFERENTIAL ANALOG INPUT MODULE Figure 5

C131-05, Page 7 SECTION #3 - FIELD CALIBRATION 7.0 Speed Range Selection 7.1 Locate dip switch SW1 on the C3000 circuit board. 7.2 Configure the dip switches for the proper speed range based on the maximum shaft speed that the C3000 will be monitoring. Make this selection before calibrating the signal output. (see figure 6, page 7) SPEED RANGE SELECTION DIP SWITCH SETTINGS LO SPEED MED SPEED MED HI SPEED HI SPEED VERY HI SPEED 8.0 Output Signal Calibration (4/20 MA or 0-10 VDC) Figure 6 8.1 Locate jumpers J1 and J2 on the C3000 circuit board. 8.2 Configure the jumper pins for 4-20 MA or 0-10 VDC. (see figure 7, page 7) L2 + - + J1 J2 J1 OUTPUT SELECTION 4/20 MA 0-10 VDC J2 9.0 Zero Adjustment Figure 7 9.1 Apply 120 VAC power to the C3000 circuit board. 9.2 Connect a digital meter to + - signal output terminal on terminal block TB1. If using the 4-20 MA scale adjust potentiometer P2 to 4 MA. If using the 0-10 VCD scale adjust potentiometer P2 to 0 VDC. CW to increase signal CCW to decrease signal.

C131-05, Page 8 10.0 Span Adjustment 10.1 Apply 120 VAC power to the C3000 circuit board. Run the machine at maximum operating speed (speed that you want to equal full scale). 10.2 Connect a digital meter to + - signal output terminal on terminal block TB1. If using the 4-20 MA scale adjust potentiometer P3 to 20 MA. If using the 0-10 VCD scale adjust potentiometer P3 to 10 VDC. CW to increase signal CCW to decrease signal. 10.3 Repeat steps 9.0 to 10.2. 11.0 Optional Tachometer Calibration 11.1 Connect display meter to + - tachometer output on terminal block TB1. 11.2 Apply 120 VAC power to the C3000 circuit board. Run the machine at normal operating speed. 11.3 With the machine running at normal operating speed adjust potentiometer P1 until the meter matches machine speed or rate. CW to increase CCW to decrease. SPARE PARTS LIST Part No. Description 1243 Circuit Board 1129 Sensing Head, w/10 Cable (std) Analog 1130 Mounting Bracket w/jam Nuts (std) 1132 Sensing Head w/10 Cable (XP) Analog 1134 Mounting Bracket (XP) 1136 Magnet Disc (4 dia) 1378 Magnet Disc (8 dia)

C131-05, Page 9 WARRANTY Process Control Systems, Inc. will repair or replace, at their option, F.O.B. factory, any part or unit which proves to be defective in material or workmanship within five years of purchase date, provided that part of the unit was installed and operated as recommended, to be established by examination of the part or unit at the factory. Goods returned under warranty must be shipped prepaid to the factory and accompanied by the serial number, description of defect, order number and date of purchase. This warranty shall not apply to any Maxigard product which shall have been repaired or altered outside of the Process Control Systems factory or has been subject to misuse, negligence or accident. Process Control Systems, Inc. warrants its products, but not their application, and shall not be liable for any incidental or consequential damages incurred through the use or loss of use of a Process Control Systems product. No representatives or other person is authorized or permitted to make any warranty or assume for this company any liability not strictly in accordance with this guarantee. There is no further warranty either expressed or implied beyond that set forth herein.