Low Pressure Filters

Similar documents
HYDRAULIC AND LUBE OIL FILTERS RFM Series

Low Pressure Filters

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Low Pressure Filters

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

MEDIUM PRESSURE FILTERS

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

Series RFL In-Line Filter

HIGH PRESSURE FILTERS

Duplex Pressure Filters

Series RFLD Duplex In-Line Filter

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS Series HF2P

NFH Low Pressure Filters

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter RFM with 4-Hole Mounting

SPIN-ON FILTERS & ELEMENTS

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

FILTER ELEMENTS. Overview of Elements PN# / / FIL

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Stainless Steel Pressure Filters Housings, Elements, Indicators & Sizing

Return Line Filter RF

Stainless Steel Pressure Filters

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

Return Line Filter RF

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Change-Over Inline Filter RFLD Weld Version

Breathers. BF...3 & BF...4 Series INNOVATIVE FLUID POWER. ø D1 HEX. Specifications. Hydraulic Symbols. Model Code. Dimensions BF P 3 G 10 W 1.0 /.

OFFLINE FILTRATION SYSTEMS

Change-Over Inline Filter RFLD Welded Version

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Change-Over Pressure Filter DFDK

Pressure Filter DF...K P, DF...M P, Flange Mounted

HPK04 Max Flow: 120 gpm (454 lpm)

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Return Line Filter RFM with 2-Hole Mounting

HMK05/25 DURAMAX Spin-Ons

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

World Pressure Filters A new standard in 7,000 psi pressure filters

Fluid Cooling Industrial COLW Series

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

10 Hydraulic Filters

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

15/40/80CN Series Coreless Medium Pressure Filters

Filters. RFD Series. Change-Over Return Line Filter Service and Parts. 2. Element Replacement. 2.1 Element Removal

RFL Cast Series Service and Parts

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration.

OVERVIEW OF RESERVOIR ACCESSORIES

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

FPK02 In-Line Cartridge Filters

10 Hydraulic Filters

FPK04 Max Flow: 100 gpm (379 lpm)

Low & High Pressure ProGuard Filters

Duplex Filter NFD (for NFD UHE (ultra-high efficiency), see NF Series) Service and Parts

CUSTOM CLAMPS. Head Bolt Arrangements. Model Code B3-5 A1 B1 A1HB B1HB S1 HRSGBLPU 30 A1 373 ST

PT Series Tank Top Filters

Be sure to order the correct number of elements: OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4

15/40/80CN Series. Medium Pressure Filters

J Series Filters HIGH PRESSURE FILTERS. J88 Mini In-Line (Replaceable Filter) J85 Tee-Type. J82 Mini In-Line. J83 In-Line

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Filters. HF4R Series. Service and Parts. Index. Inlet. Outlet. ø7 (ø177.8mm) Bolt Circle ø6.25 (ø158.8mm) ø0.44 (ø11.1mm) 4 Places Equally spaced

LPF Series Service and Parts

12CS/50CS Series. Coreless Spin-on Filters

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

12CS/50CS Series Coreless Medium Pressure Filters

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

NF, NF UHE, NFD UHE & NF MMP with 2600 R element (for Ecomicronfit ( D) element version, see NF 1314/2614 Eco-Fit Series) Service and Parts

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Medium Pressure Filters

MPD Series. Medium Pressure Duplex

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

MPD Series Medium Pressure Filters

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RF4 Series. Return Line Filters

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

DT-350 In-Line Hydraulic Filter

Return line and Suction Boost Filter RKM

Tank top return-line filter Pi 5000

Filters. DFFH & DFFHM Series Service and Parts. Index. This symbol is followed by user tips and particularly useful information

CFU. Compact Filter Unit. hyprofiltration.com/cfu

MPD Series. Medium Pressure Duplex

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Transcription:

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com RFM Series In-Tank Return Line Filters Features The compact and lightweight design make RFM filters especially suitable for mobile applications. RFM filters are constructed of polyamide plastic housing and lid. RFM 9///7 drop replacement for Tank Topper filters. alloy is water tolerant - anodization is not required for water based fluids (HWBF). The filter bowl on models 7-7 also serves as a contamination basket - removed to change element. Models,, 66, and 8 have filter elements equipped with separate, reusable contamination baskets. Cavities for clogging indicators are standard. NEW! s 7/9//6/8 available with - or -bolt tank flange. Applications Agricultural Automotive Construction Hydraulic Symbol A T Technical Details T Mounting Method 7/9//6/8 mounting holes - filter housing 7/9//6/8//7/ //66/8 mounting holes - filter housing Port Connections Inlet / Outlet 9/ 7/6/8 /7 / SAE- / SAE-6 /.6 Smooth Port SAE- / Open Bottom SAE- / NPT / SAE Flange, Code 6 / NPT / SAE Flange, Code 6 / G / BSPP 66/8 Direction of Flow Side inlet and bottom outlet. Mat. of Construc. Head Bowl Lid 9//7/6/8 /7 //66/8 Flow Capacity 7 9 6 8 7 66 8 Housing Pressure Rating Max. Oper. Press: Proof Pressure: Fatigue Pressure: Burst Pressure: Steel gpm (7 lpm) gpm (9 lpm) gpm ( lpm) gpm (6 lpm) 9 gpm (8 lpm) gpm ( lpm) 7 gpm (7 lpm) 87 gpm ( lpm) gpm ( lpm) 7 gpm (66 lpm) gpm (8 lpm) Element Collapse Pressure Rating BN/HC, W/HC ECO/N, BN/AM, P/HC, AM V Fluid Temperature Range Fluid Compatability A T psi ( bar) 8 psi ( bar) psi ( bar) @ million cycles 6- >8 psi ( bar) 66/8 6 psi (7 bar) 9 psid ( bar) psid ( bar) psid ( bar) - to F (- to C) Compatible with all petroleum oils and synthetic fluids rated for use with Fluoroelastomer or Ethylene Propylene seals. Contact HYDAC for information on special housing and element constructions available for use with water glycols, oil/water emulsions, and HWBF. Indicator Trip Pressure P = 9 psi ( bar) -% (standard) P = 7 psi ( bar) -% (optional) Bypass Valve Cracking Pressure ΔP = psid ( bar) +% (standard) ΔP = 87 psid (6 bar) +% (optional) 6 INNOVATIVE FLUID POWER

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com Model Code RFM BN/HC B F F D. X / - V - - L. Filter Type RFM = In-Tank Return Line Filter Element Media BN/HC = Betamicron (Low Collaspe) (not for sizes 9 & ) ECO/N = ECOmicron (Low Collaspe) (not for sizes /7) BN/AM = Betamicron Aquamicron MM = Mobilemicron (Low Collaspe) AM = Aquamicron W/HC = Wire Screen 7, 9,, 6, 8,, 7,,, 66, 8 Working Pressure B = psid ( bar) Optional Second Inlet Connection (omit) = no second port F = / (SAE-) (sz. & only) K = / SAE Flange (code 6) (sz. & only) M = / SAE Flange (code 6) (sz. 66 & 8 only) V = x (SAE 6) (sz. & 7 only) Inlet Connection/Port ( Inlet) C = / (SAE-) (sz. 9 & only) K = / SAE Flange (code 6) (sz. & only) D = (SAE-6) (sz. 7, 6 & 8 only) M = / SAE Flange (code 6) (sz. 66 & 8 only) E = / (SAE-) (sz. & 7 only) Z = Customer Specific F = / (SAE-) (sz., 7,, & only) Filtration Rating (microns),,, = BNHC, ECO/N, = P/HC, = BN/AM, 7, 9 = W/HC = AM, = MM Type of Clogging Indicator A, B, BM, C, E, F, FD Type Number = no indicator, no ports - = clogging indicator positions (see chart) Modification Number (latest version always supplied) Inlet Port Configuration = SAE Straight Thread O-Ring Boss Ports (RFM 6-) 6 = SAE Code 6 Flange (sizes -8) Seals (omit) = Nitrile (NBR) (standard) V = Fluoroelastomer (FPM) Bypass (omit) = psid (standard) B6 KB = Bypass 87 psid (6 bar) = No Bypass not available with ECO/N Supplementary T = Filter Breather (RFM 7, 9,, 6, & 8 only) DTxx = Down tube (xx length in inches - up to inches) DSxx = Dip stick (xx length in inches) SOH = Modification of BNHC Elements for Phosphate Esters L = bolt (sizes 9-8) M = Indicator with Deutsch Connector (FD indicator only) Replacement Element Model Code R BNHC / V 7, 9,, 6, 8,, 7,,, 66, 8 Filtration Rating (micron),,, = BNHC, ECO/N, = P/HC, = BN/AM, 7, 9 = W/HC = AM, = MM Element Media BNHC, ECO/N, P/HC, BN/AM, W/HC, AM, MM Supplementary Details (omit) = standard V = Fluoroelastomer (FPM) seals Clogging Indicator Model Code VR B. X /. Indicator Prefix VR = Return Filters (sizes to 8) VMF = Mobile Filters (sizes 7 to 7) Trip Pressure = 9 psid ( bar) = 7 psid ( bar) (optional) Type of Indicator A = no indicator, plugged port B/BM = Visual pop-up (auto/manual reset) C = Electric switch E = Visual pressure gauge F = Electric pressure switch FD = Electric pressure switch w/deutsch Connector Modification Number Supplementary Details M = Deutsch Connector (male) Seals (omit) = Nitrile (NBR) (standard) V = Fluoroelastomer (FPM) (For additional details and options, see Clogging Indicators section.) Model Codes Containing RED are non-stock items Minimum quantities may apply Contact HYDAC for information and availability INNOVATIVE FLUID POWER 6

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com Clogging Indicator Locations RFM 7/6/8 RFM 7/6/8/-L. 6.. RFM 9/ RFM /7. Plug RFM /. Plug. Standard RFM 9//-L. Standard. Plug. Standard RFM 66/8. Standard. Standard... Plug.........X.X.X.X 6.X.X.X.X.X Clogging Indicator left back Clogging Indicator right back.x Clogging Indicator left 9 to Inlet Clogging Indicator right 9 to Inlet.X Clogging Indicator on Top.X Clogging Indicator left back 9 to Inlet Clogging Indicator left back to Inlet 9 to Inlet 9 to Inlet Clogging Indicator left 9 to Inlet Clogging Indicator right 9 to Inlet.X Clogging Indicator on Top 6 INNOVATIVE FLUID POWER

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com Dimensions RFM 7/6/8 RFM 9/.9 (8mm) RFM 7.8 (mm) RFM 6 8. (6mm) RFM 8.7 (7mm) Clearance Required RFM 7.7 (mm) G /8 (G /8 adapter supplied with indicator) RFM 7/6/8/-L Clearence for Element Removal RFM 7.9 (mm) RFM 6 9. (mm) RFM8.8.9 (mm) (8mm) RFM9.7 (mm) RFM 7.8 (mm) RFM 6 8. (6mm) RFM 8.7 (7mm) RFM 9. (69mm) ø.77 (ømm) RFM 6 8.98 (8mm).9 (mm) ø.6 (mm) RFM 8.7 (9mm) /8 NPT Option OUTLET ø.9 (ø7.mm).8 (8mm). (mm) /6 - UN-B SAE-6 Port. (mm) INLET Tank Opening ø.7 (ø78mm) ø.89 (ø7.mm) Required Clearance.8" (7mm) RFM 9 6.7 (7mm) RFM. (mm) RFM 7/6/8/-L Tank Opening ø.7 (78mm) ø.7 (6mm) ø.96 (6mm) RFM 9//-L ø. (8.mm) Tank Opening ø. (6mm) RFM 9 7.87 (mm) RFM. (8mm) Hose Barb (mm)." (7mm) G /8 (G /8 adapter supplied with indicator) 7 9 6 8 7 66 8 Weight (lbs.)..9...6 6.8 7.9 6.8 7...." (mm). (9mm) ø. (9mm) Dimensions shown are for general information and overall envelope size only. Weights listed are without element. For complete dimensions please contact HYDAC to request a certified print. RFM 7/6/8 w/ oil separator. (8.mm) RFM 7/6/8. (mm) Clearance for Element Removal.8 (6mm).6 + (6 + mm) RFM 9 9.68 (6mm) RFM.9 (9mm) RFM 7/6/8 w/out oil separator.89 (7.mm) RFM 9//-L. (79mm) RFM 9 6.7 (67mm) RFM 9.8 (mm) Tank Opening ø. (ø6mm) RFM 9/. (9mm) OUTLET RFM 9/. (6mm) RFM 7/6/8.7 (mm) RFM 9/. (8.mm). -. (6. -. mm) ø.6 (ø6mm) INLET. (mm) INNOVATIVE FLUID POWER 6

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com 6 RFM 66/8 Dimensions RFM /7 RFM / Required Clearance.78" (96mm) RFM 9.9 (mm) RFM 7. (8mm) RFM.8 (mm) RFM 7 6.9 (mm) open bottom Ø.9" (mm) G /8 (G /8 adapter supplied with indicator).8" (mm) Indicator Port G /".96 (6mm).6 (mm) RFM 66.8 (mm) RFM 8. (8mm) Clearance for Element Removal RFM 66.9 (mm) RFM 8 6. (mm) 7.87 (mm) Threaded Outlet G / ø 6. (6mm) 7 9 6 8 7 66 8 Weight (lbs.)..9...6 6.8 7.9 6.8 7... Dimensions shown are for general information and overall envelope size only. Weights listed are without element. For complete dimensions please contact HYDAC to request a certified print. INNOVATIVE FLUID POWER Clearance Required Indicator Port G / RFM. (6mm) RFM. (8mm) 6. (mm).86 (98mm).88 (8mm) RFM 6.77 (7mm) RFM 9.96 (mm) RFM /7 6.7 (7mm) RFM /7. (.6mm) RFM / 6.97 (77mm) Threaded Outlet NPT ø.8 (mm) RFM /.88 (mm) RFM 66/8 8.66 (mm) RFM 66/8 6.7 (67mm) RFM /7//. (mm) RFM 66/8. (.mm)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com Sizing Information Element K Factors Total pressure loss through the filter is as follows: Assembly ΔP = Housing ΔP + Element ΔP Housing Curve: Pressure loss through housing is as follows: Actual Specific Gravity Housing ΔP = Housing Curve ΔP x.86 Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see sizing section on page 9) RFM 9/ & RFM 9//-L Housing RFM 7/6/8 & RFM 7/6/8/-L Housing 7 8 76 7 8 6. 6........ RFM / 7 Housing 76 7 78 6 6 8... RFM / Housing 7 Actual Viscosity (SUS) x Actual Specific Gravity ΔP Elements = Elements (K) Flow Factor x Flow Rate (gpm) x (From Tables Below) SUS.86...R...BNHC (Betamicron Low Collapse) μm μm μm μm 7.9.78.. 6.66... 8.8..79.97...96.6 7.8.9.6.9...9.66.6..69. 66..66..9 8.8..6. R W/HC (Wire Screen),, 7,, 9, μm 7. 6...7 66. 8. All Element K Factors in psi / gpm....... R MM μm μm 7.6.66 9..8..7 6.6.9 8.8.67.. 7...78.9.. 66..9 8.....R...P/HC (Paper), μm 7.6.8 6.86.7. 66.6 8. RFM 66/8Housing 6 8 6 R AM A.6.8 66.9 8.7...... R ECO/N (ECOmicron ) μm μm μm μm 9...6.7.67.9.77.89 6.67.69.. 8..7.7.6.8.6. 66..68.9. 8.78..6....R...BN/AM μm μm.77.6 66.9.66 INNOVATIVE FLUID POWER 66