ELECTRIC WATER PUMP (EWP ) KIT INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

DAVIES, CRAIG PROPRIETARY LIMITED A.B.N A.C.N MELBOURNE AUSTRALIA

ELECTRIC WATER PUMP (EWP ) & LCD EWP /FAN CONTROLLER INSTALLATION INSTRUCTIONS. EWP80, EWP115, EWP130, & EWP150 Combo Packs

EWP 110 INSTALLATION INSTRUCTIONS

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions

Part No EWP & FAN DIGITAL CONTROLLER INSTRUCTIONS

Max. Current. 3 V - 15 V DC 10 Amps. 20 V - 27 V DC 5.5 Amps. 3 V - 15 V DC 10 Amps. 20 V - 27 V DC 5,5 Amps. 3 V - 15 V DC 10 Amps

Electric Water Pump (EWP )

Davies Craig THERMACTIC FANS 1

Electric Water Pumps

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO COMPLY MAY VOID DAVIES, CRAIG WARRANTY.

Transmission Oil Coolers Ultra-Cool & Hydra-Cool

Digital Controller 12 volt only

ELECTRIC FAN. As a primary cooling source electric fans provide:

About this catalogue:

2015+ SUBARU STI FRONT-MOUNT INTERCOOLER PARTS LIST AND INSTALLATION GUIDE INSTALL DIFFICULTY DISCLAIMER CAUTION INSTALL PROCEDURE TOOLS NEEDED

Consists of. Date:17/02/2011 Page 1/8

Installation Instructions

Introduction. TyreGuard 400 Assembly. Unit Conversion DAVIES, CRAIG PTY LTD TYREGUARD

Specialist Components. SPi 5 Port EFI Kit

WPS-104 Heater Installation Instructions For 500EFI, 700 XP, & Crew Applications

Transmission Oil Coolers

All cores due 30 days after invoice date - no credit after 60 days.

Tecomotive - tinycwa User Manual

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

Installation Instructions for: TOYOTA 4.5L SUPERCHARGER SYSTEM

PRODUCT SAFETY NOTICE

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1

BH128SY FITTING INSTRUCTIONS

Scion FR-S ZN6. GTX2867R Gen2 (Internal Wastegate) Installation Instructions GPP P/N #

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

PRODUCT SAFETY NOTICE DEALER/INSTALLER NOTICE

C40008 & C40009 EXHAUST BRAKES

SS41HF Mitsubishi Pajero NS & NT V8/V9 Series 3.2 Litre Turbo Diesel (4M41 Engine) 3.8 Litre V6 Petrol (6G76 Engine)

Information Booklet WW20072

Step 6: Remove and save the MAP sensor for later use. Step 7: Remove the passenger side intercooler pipe and the EGR intake manifold.

EAF164SY FITTING INSTRUCTIONS

All cores due 30 days after invoice date - no credit after 60 days.

Shotgun Double Barrel HPFP install guide

Installation Manual v2.2: Twin CP3 Fuel Injection Kit Dodge 5.9L

DirectMount EXHAUST BRAKES

V1 Truck Manifold Turbo Kit for F-body

Cooling System Description and Operation

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

INSTALLATION INSTRUCTIONS For Model 855 Wolo Express TM

WEG Cooler. Table of Contents. Introduction and General Description. 3. Operational Specifications.. 4. Dimensional Specifications.

DOMINATOR FUEL PUMPS P/N & Installation Instructions 199R10573

PRXB EXHAUST BRAKE MAXIMUM EXHAUST FLOW DESIGN

Model 6275RC 50% Duty Cycle Compressor

Installation Manual v1.0: Force Cool Kit Dodge with NV4500/NV4500HD/NV5600 Manual Transmissions. Please read all instructions before installation.

2014 RAM C/V Tradesman

Special Note About The JDM High Performance Water Pump:

DODGE CUMMINS COOLANT BYPASS KIT

Engine Cooling. Cooling System Component Layout.

Installation Manual v1.1: Piece Pulse Flow Exhaust Manifold, Stock Replacement L Cummins

SERVICE SCHEDULE. Zero-Turn Mowers

EAGW10SY FITTING INSTRUCTIONS

Shotgun Single Barrel HPFP install guide

VW/Audi FSI 2.0T K04 Turbocharger Kit NO NOISE PIPE FOR RACING USE ONLY INSTALLATION GUIDE

2013 Kia Optima L4-2.0L Turbo

COOLING SYSTEM. Return to Main Table of Contents

DODGE CUMMINS COOLANT BYPASS KIT

Rotrex C-type Superchargers. Setup and maintenance

WATER PUMP INSTALLATION INSTRUCTIONS WEIAND WATER PUMPS ACTION PLUS & TEAM G APPLICATIONS FOR SMALL BLOCK & BIG BLOCK CHEVROLETS

XRT300 AND XRT350 BA XR6 TURBO UPGRADE KIT FITTING INSTRUCTIONS

PRXB EXHAUST BRAKE HIGH PERFORMANCE

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

SLP Camaro ZL1 STAGE 3 (650 HP)

Official Powerdyne Model BD Supercharger and Kit Limited Warranty

HOLLEY LS-SWAP WATER PUMPS WATER PUMP INSTALLATION INSTRUCTIONS FOR GM LS-ENGINE APPLICATIONS:

BD Dual Transmission Cooler Dodge (68RFE, 518, 47RH, 47RE & 48RE) Ford (5R110) & Chevy (Allison 1000) Transmissions

Antifreeze Type SYC1025 (Long life coolant) Mixing ratio (water:antifreeze) Cooling fan module Type Electric Capacity

8 Pin Female Plug. WIRING INSTRUCTIONS TO SUIT : Holden VT V6+V8

COOLING GROUP 7 CONTENTS

DODGE CUMMINS COOLANT BYPASS KIT

Function of residual engine heat utilization system

SS985HF Mazda BT-50 B32P Series 3.2L 5cylinder TDCi Diesel (P5AT Engine)

PLATINUM. Sport Haltech 13B Terminated Engine Harness QUICK START GUIDE

Section 3 Technical Information

RESPA -CF/CFX Installation Kit for Komatsu D475A-5E0

Installation Manual v1.0: Twin CP3 Fuel Injection Kit Dodge 5.9L

INSTALLATION MANUAL AP60B INSTALLATION MANUAL

Installation Instructions

SS175HF ISUZU D-MAX (June 2012 onwards) 3.0Litre, 4 Cylinder Turbo Diesel (4JJ1-TC Hi-Power Engine)

Part No. TL200R1. TOYOTA LANDCRUISER 200 SERIES 160lt REPLACEMENT LONG RANGE FUEL TANK PARTS LIST AND FITTING INSTRUCTIONS

Thermo-Bob 4 Installation Manual. TB4-KT4A Kit KTM 450 SX-F KTM 450 XC-F Husky FC450

A2P Single Phase Automatic Industrial Battery Charger

SECTION 6A1-2 - ENGINE MECHANICAL - V6 SUPERCHARGED

Installation Manual v1.0: Twin CP3 Fuel Injection Kit Dodge 6.7L

Rzr Heater System Part #

Engine and cooling system (ALL-R K-50-A)

READ THIS BEFORE PROCEEDING

BLACKBIRD INSTALLATION SUPPLEMENT

2017+ L5P Duramax 3 ½ Down Pipe & EGR Fix Kit

Water Heater Unit. Thermo Top C Additional Heater. Installation Instructions. FORD Connect. Gasoline and Diesel. not with automatic transmission

SECTION 1D1 M162 ENGINE COOLING

Tecomotive - tinycwa - User Manual Intercooler Version

HP FUEL PUMPS P/N & Installation Instructions 199R10569

96-04 tt. Hellion Power Systems Mustang Twin Turbo Kit Instructions

INSTALLATION INSTRUCTIONS

Transcription:

77 Taras Avenue P.O. Box 363 Altona North Vic 3025 Australia Phone: +61(0)3 9369 1234 Fax: +61(0)3 9369 3456 info@daviescraig.com.au ELECTRIC WATER PUMP (EWP ) KIT INSTALLATION INSTRUCTIONS EWP80, EWP115, EWP130, & EWP150 Kits PLEASE READ ALL THESE INSTRUCTIONS THOROUGHLY BEFORE YOU START WORK. DON T RUSH - ENSURE YOU HAVE FULL UNDERSTANDING OF THE WORK AHEAD BEFORE YOU COMMENCE. ENSURE YOU HAVE ALL TOOLS AND COMPONENTS REQUIRED. Congratulations on your purchase of the Davies, Craig EWP Electric Water Pump Kit which is designed to replace or complement the existing belt driven mechanical water pump. In addition with a Davies, Craig Digital Controller your thermostat can be replaced. The major benefits of an Electric Water Pump (EWP ) are, removal of the parasitic power losses running a mechanical water pump at any speed, reduction of engine warm-up time and elimination of heat soak by running the EWP after a hot engine shut down by operating the EWP with the EWP/Fan Digital Controller, or one of the Davies, Craig Thermatic Switches. Your new EWP has the advantage of providing the best coolant flow rate independent of engine speed. TABLE OF CONTENTS EWP KIT CONTENTS... 2 SECTION 1: INSTALLING YOUR EWP... 3 SECTION 2: OPTIONS FOR PUMP CONTROL... 4 SECTION 3: DISABLE EXISTING MECHANICAL WATER PUMP... 8 SECTION 4: BLEEDING THE EWP... 9 SECTION 5: OPERATING YOUR EWP ELECTRIC WATER PUMP... 10 CAUTIONS... 11 P/No:18924 EWP Kit Customer Instructions. Page 1 of 12

EWP130 (12V/24V) EWP Components EWP KIT CONTENTS Hardware Bag Components Part # Description Qty. Part # Description Qty. 8180 or EWP Pump Short (12V) N/A Scotch Lock 1 1 8181 EWP Pump Short (24V) N/A Ring Terminal 1 8515 Wiring Harness 1 N/A Self-Tapping Screw 1 18301 L Adaptor 35mm (Alloy) 1 N/A Adaptor M5 Bolt 12 18302 Straight Adaptor 35mm (Alloy) 1 N/A Relay 1 8509 O-Ring 2 18510 EWP Rubber Sleeve 3mm 2 18512 Hose Clamps 2 8909 / 8910 Hardware Bag 1 EWP150 (12V) - EWP115 Alloy (12V) - EWP115 Nylon EWP Components Hardware Bag Components Part # Description Qty. Part # Description Qty. 8160 or EWP150 Pump Short N/A Scotch Lock 1 8140 or EWP115 Alloy Pump Short, 1 N/A Ring Terminal 1 8125 EWP115 Nylon Pump Short N/A Self-Tapping Screw 1 8515 Wiring Harness 1 N/A Relay 1 18510 EWP Rubber Sleeve 3mm 2 18512 Hose Clamps 2 8526 EWP Hardware Bag 1 EWP80 Nylon (12V) EWP Components Hardware Bag Components Part # Description Qty. Part # Description Qty. 8105 EWP Pump Short 1 N/A Scotch Lock 1 8515 Wiring Harness 1 N/A Ring Terminal 1 8309 Elbow Adaptor 35mm (Nylon) 1 N/A Self-Tapping Screw 1 8307 Straight Adaptor 35mm(Nylon) 1 N/A Adaptor M5 Bolt 6 8509 O-Ring 2 N/A Adaptor M5 Nut 6 18510 EWP Rubber Sleeve 3mm 2 N/A M5 Cap Screw Long 6 18512 Hose Clamps 2 N/A Relay 1 8908 EWP Hardware Bag 1 Optional Accessories Part # Description Suitable for No. 1025 Flanged Adaptor All EWPs 1 1024 90 Degree Adaptor EWP115 (Alloy Only), EWP150 8700 EWP Mounting EWP115 Bracket EWP115 EWP130 8000 Digital Controller All EWPs 2 3 4 3. 1. 2. 4. Page 2 of 12

SECTION 1: INSTALLING YOUR EWP 1. Your EWP Electric Water Pump is best fitted in the lower radiator hose which connects the radiator to the existing mechanical water pump housing. In conventional vehicle operating conditions, the hose will carry the weight of your EWP and insulate the EWP from engine vibration. Check the area for available space. Further radiator hose or adaptors may be required. Position the EWP in the lower hose so the inlet, in the centre of the pump is connected to the radiator side and the outlet is connected to the engine s mechanical water pump housing or your EWP Header Adaptor (not supplied). The EWP should be positioned as low as possible to maximise the gravity feed from the radiator and to avoid air entering and remaining in the pump. Alternatively, the EWP may be fitted in the upper radiator hose. In this case, coolant level is critical and bleeding of all air from the cooling system essential. Follow instructions above for correct EWP fitment ensuring the pump outlet is connected to the hose going into the top of the radiator. The pump can be installed in any orientation but to assist air bleeding try to mount the outlet pointing upwards. (See Section 8 for bleeding instructions). Ensure your cooling system is kept full of coolant. 2. If you have either an EWP130 or EWP80, assemble the provided EWP Straight and L Adaptors to suit the configuration and space available. Ensure that the Straight and L Adaptors have the O-Ring fit securely between them and the flange faces on the EWP body. Six of the shorter Adaptor M5 Bolts (Part # 8507) should be used to attach the Adaptor to the EWP outlet. The remainder M5 bolts (Part # 8507 for EWP130) or (Part # 8514 for EWP80) can be used to attach the Adaptor to the EWP Inlet. If necessary, add the rubber sleeves to the inlet and outlet of the EWP to suit your particular hose diameter. If you require thicker sleeves, contact Davies, Craig for supply free of charge. 3. Cut out the not required section of the radiator hose. Connect the pump inlet and outlets to the appropriate hose ensuring hose clamps are very firmly tightened. Page 3 of 12

SECTION 2: OPTIONS FOR PUMP CONTROL 1. With EWP Fan Digital Controller, Part #8000 or Part #8020: We highly recommend the use of the EWP & Fan Digital Controller for maximum cooling efficiency. The EWP & Fan Controller will vary the EWP speed in response to the coolant temperature. You set the temperature desired for maximum power or fuel efficiency. The Digital Controller has an in built function that allows the EWP to run on after hot engine shutdown to eliminate heat soak. We further recommend the removal of the engine s thermostat and disabling of mechanical water pump. The pump belt may need to be modified or the pump pulley left as an idler. The vehicle s heater may take a little longer to warm up and to improve the heating, we recommend the fitment of an Electric Booster Pump (EBP) to the heater line if necessary. 2. With Davies, Craig Thermatic Switches, Part #0401 or Part #0444: Combine the EWP with either of the approved Davies, Craig thermal switches listed here when the EWP is used as a booster pump to assist the existing mechanical water pump cool an overheating engine. Connect the thermal switch directly to the battery and your EWP will run on to eliminate heat soak. You may leave the thermostat in place, but ensure the EWP operates only when the thermostat is fully open. 3. Continuous running: Wire the EWP direct to the ignition for maximum cooling (race vehicles, very hot climates). This option requires the removal of the engine thermostat and the mechanical pump impeller or pump belt. This option may also be used for road cars with the thermostat in place with a small hole (suggest 5mm), allowing a small amount of flow to circulate even when the thermostat is closed. WARNING: When using the Electric Water Pump (EWP ) on vehicles using LPG, it is recommended that an EBP be fitted to circulate coolant through the LPG converter. Part #8000 LCD Controller Part #0444 Thermatic Switch Page 4 of 12

OPTION 1: INSTALLING EWP & FAN DIGITAL CONTROLLER Part #8000 or Part #8020 NOTE: Wiring from EWP kit will not be required however retain for hard wiring the EWP during bleeding. 1. The Digital Controller must be fitted inside the passenger compartment. 2. Connect the wiring harness to the Digital Controller and mount the Controller in an appropriate position --- avoid mounting the controller where it may be exposed to direct sunlight. 3. An additional screw is provided for mounting Digital Controller fuse holder where necessary. 4. Mount Remote Test Light in a location, which will be visible. The Test Light may be fitted by inserting it through a 4.6mm hole drilled in a plastic area of the interior/dashboard or simply with adhesive tape. 5. For installation of the sensor in the position of the thermostat refer to the Digital Controller instruction booklet. 6. Bleed the EWP. Refer to SECTION 4: BLEEDING THE EWP (Page 9). After bleeding the EWP continue with the installation process. Part #8020 Above Part #8000 Page 5 of 12

OPTION 2: USING THE EWP AS A BOOSTER PUMP Part #0401 or Part #0444 NOTE: This option when combined with a Davies, Craig Thermatic Switch, Part #0401 or Part #0444, will turn the EWP on at the temperature you set, to give additional flow to an overheating cooling system. INSTALLING THERMAL SWITCH (Part #0401 OR #0444) 1. Install the Thermo Switch (Part #0401 or Part #0444) - Refer Wiring Diagrams (Figure 1 and Figure 2) below. 2. For detailed instructions on installing switches, please refer to 0401 & 0444 instruction sheets. 3. Bleed the EWP. Refer to SECTION 4: BLEEDING THE EWP (Page 9). After bleeding the EWP continue on with the next stage. PUMP MOTOR RELAY & LOOM FROM PUMP PACKAGING GREEN THERMAL SWITCH RED BLUE + _ BLUE BLACK EARTH FUSE BATTERY Figure 1: Wiring Diagram: EWP With Thermal Switch - Part #0401 WARNING: ENSURE IGNITION SOURCE IS NOT CONNECTED TO THE ENGINE MANAGEMENT SYSTEM PUMP MOTOR BLUE 1 1 RELAY BLACK GREEN 86 30 87 RED 85 2 EARTH 1 THERMAL SWITCH FUS E 5 FUS E 5 ORANGE 2 BLACK YELLOW 3 IGNITION RED 4 +VE BATTER Y 1. BLUE CONNECTOR 2. SELF TAPPER 3. SCTOCHLOCK 4. RING TERMINAL 5. FUSE HOLDER & FUSE Figure 2: Wiring Diagram: EWP with Thermal Switch - Part #0444 Page 6 of 12

OPTION 3: CONTINUOUS RUNNING (Recommended for race vehicles, very hot climate & cars running on LPG.) Continuous EWP operation may be required for some road or race engine applications, in some very hot climatic conditions and engines fitted with liquid petroleum/butane gas (LPG) conversion. This option will provide maximum flow from your EWP under all operating conditions without a Digital Controller or a Thermatic Switch fitted. Should you choose this method you should retain the engine thermostat and drill one or two holes (suggest 5mm) in the plate to allow some coolant flow when the thermostat is closed. PUMP MOTOR +VE IGNITION SOURCE RELAY & LOOM FROM PUMP PACKAGING GREEN RED FUSE + _ BLUE EARTH BATTERY BLACK Figure 3: Wiring Diagram: EWP Continuous Running Page 7 of 12

SECTION 3: DISABLE EXISTING MECHANICAL WATER PUMP Davies Craig has tailor made EWP Header-Adaptor Kits visit the website for details, see image below (Part#8630). 1. You may choose to by-pass the belt-driven water pump pulley by installing a shorter belt. This option may not be possible if the crank pulley drives a beltdriven power steering and fan or unless you replace the mechanical fan with a Davies, Craig Thermatic Fan. For example see Figure 4 below: 2. Remove the thermostat from the thermostat housing. 3. Re-fit the thermostat housing ensuring that there is no damage to the thermostat-housing gasket. BEFORE Water Pump Pulley AFTER Water Pump Pulley Alternator Pulley Crank Pulley Alternator Pulley Crank Pulley Figure 4: Belt Orientation Diagram OR 1. Remove the existing belt-driven water pump housing. 2. Remove the water pump impeller from the pump shaft. (NOTE: You may need to drill holes through the impeller close to the drive shaft.) Alternatively, remove vanes from impeller. Mechanical water pumps differ from engine to engine and you need to take appropriate action that suits the specific water pump to disable the pump. 3. Re-fit the water pump housing without the impeller ensuring that there is no damage to the water pump gasket and the pump seal is still retained. Re-fit the water pump belt and tighten to manufacturer s specifications. Part #8630 - EWP Header-Adaptor Kit (Ford Big Block) Page 8 of 12

SECTION 4: BLEEDING THE EWP For the EWP 80 ensure it is orientated correctly as shown below before continuing. NOTE: This orientation is a temporary requirement for the purpose of bleeding the pump and ensuring there is no air entrapped within the seal housing of the pump. The pump can be set-up in another orientation upon completion of the bleeding procedure. INLET AIR POCKET INLET Correct Pump Orientation Wrong Pump Orientation Figure 5: EWP80 Pump Orientation Diagram FOR ALL EWPS: 1. Fill the engine cooling system with appropriate coolant. 2. Turn heater on full. 3. With the radiator cap off, hardwire the EWP directly to the vehicle s battery or a 12v power source. Air trapped in the cooling system will exit at the top of the radiator. 4. Turn on engine and idle. 5. Top up the radiator with coolant with the EWP running until all air is eliminated. Waterless coolants increase the load on an EWP and may reduce pump life. 6. Turn off engine. 7. Replace the radiator cap and reconnect the EWP to the wiring system supplied. Page 9 of 12

SECTION 5: OPERATING YOUR EWP ELECTRIC WATER PUMP Start engine, confirm no leaks at radiator hoses and re-torque radiator hose clamps if required. Monitor the engine temperature, which should take longer than usual to reach steady state. If the ignition is left on (or if a turbo timer is connected) after a hot shut down, the pump will continue to run and prevent engine heat soak. Re-tighten the hose clamps after a few hours running at temperature and again after 20 hours running. Check for leaks. NB: The heater circuit may take longer than normal to warm up. SECTION 6: EWP INSTALLATION RECOMMENDATIONS To ensure maximum life and optimum performance from your new EWP, Davies, Craig recommends: Storage - If a EWP is installed in your vehicle s engine cooling system, stored and/or not started or driven for more than 3 months, e.g. a show/static display or race car, it s strongly recommended the EWP is operated for approximately 5 mins constant running every month. This will minimise the build-up of any sediment in the EWP and also lubricate all parts within the pump. Heater - For improved heater performance on vehicles which have the heater inlet (return) and outlet ports in the mechanical pump housing (referred to in Warnings ), Davies, Craig suggests the fitment of the EBP. This unit fits into the heater hose and boosts coolant flow through the heater circuit and/or cylinder heads. Check out website www.daviescraig.com.au LPG (Liquid Petroleum Gas or Butane) vehicles require constant flow through the LPG converter and if the EWP is used in conjunction with the EWP /Fan Digital Controller, we recommend the installation of an EBP to overcome the converter body freezing at start-up. As a preventative measure, we strongly recommended you flush out your engine s cooling system every 6 months or 10,000kms to help remove any build up of sediment. Page 10 of 12

CAUTIONS Do not operate your EWP dry as seal damage may occur and your warranty may be jeopardised. Use of the EWP after removing the pump impeller or deleting the mechanical pump pulley from the belt system will increase maximum engine speed. Running an engine at higher than normal speeds may affect other engine components. Engine temperature must be monitored closely at all times more especially after installation and until your EWP operational procedures have been confirmed. The EWP can handle most rust particles, shale, and sludge found in cooling systems but large rust particles should be flushed from the radiator before the EWP is installed. Some engines may require special bleeding procedures to remove all air from their cooling system. The EWP must be completely full of coolant at all times to achieve the life expectations of your EWP and to ensure your warranty is not jeopardised. Do not use the vehicle s engine management system or wiring connected to the vehicle s engine management system (ECU) as an ignition source as it may cause failure of the management system and/or the electrical system. The ignition source for your EWP and EWP /Fan Digital Controller Combo Kit must be a steady positive supply of 12-14V or 24-27V DC. Vehicles with both heater circuit inlet (return) and outlet ports in the mechanical pump housing will suffer reduced heater performance unless the heater returns position is relocated. The engine cooling system must use coolant as specified by the vehicle s manufacturer. The EWP is a circulation pump ideal for most closed circuit pressurised automotive cooling systems. The EWP is not a self-priming water pump and therefore will not produce its full flow without a positive head in an open system. The EWP impeller tip clearance has been designed to achieve maximum efficiency and is therefore very close to the housing. When new and bedding in, the impellor may touch the internal wall of the EWP housing causing a slight noise. This sound will cease within a very short time after the impeller has bed-in. Waterless coolants increase the load on an EWP and may reduce pump life. These installation instructions will suit most vehicles but there are circumstances surrounding some engine designs, environments, and the nature of motoring involved, which may require other installation arrangements not outlined here. Frequently Asked Questions are listed on our website www.daviescraig.com.au Davies Craig Pty Ltd appreciates customer feedback. Emails can be directed to info@daviescraig.com.au or telephone +61 (0) 3 9369 1234. Page 11 of 12

WARRANTY We warranty that for a period of two years or 2000 hours continuous running (whichever is the lesser) from the date of purchase, we shall carry out, free of cost, any repairs that are reasonably necessary to correct any fault in the operation of your Electric Water Pump provided that such a fault is directly attributable to a defect in the workmanship or materials used in the manufacture of the part(s) and is not due to installation other than described in these instructions. Labour and consequential costs are excluded. DAVIES, CRAIG PTY. LTD. REGISTER YOUR WARRANTY AT: www.daviescraig.com.au Page 12 of 12