Series 3000 O:l Pump Installation Kit Instructions 6-52 Page O:l SINGLE ACTING PUMP INSTALLATION (P/N 3 598) KIT INTRODUCTION. The O:l Single Acting Pump Installation Kit gives you all the necessary items to change a Series 3000 unit with a 2:l Piston Pump over to a O:l Single Acting Piston Pump. This pump is made available for those applications that require a higher instantaneous delivery rate than the dual acting pumps can provide. Application constraints include: The application must have a low duty cycle (2 cycles per minute maximum). a. Time to fill the pump (upstroke) is approximately.72 sec. b. Pump must be energized 200 msec before opening the guns. stroke equals 2. cubic: inches (35 cubic centimeters). The pump kit includes a 2 position, 3 way, solenoid valve that operates at either 2 VDC or 20 VAC. A CAUTION: The kit should not be fitted on Series 3800 or 3900 hopper applicators, because hopper adhesive head pressure may cause leaks at the pump mount. INSTALLATION Use the following procedure to remove the 2:l pump and install the O:l pump. Refer to the O:l Kit Parts List and Figure for part identification. The numbers in parentheses refer to the item numbers in Figure. The single acting pump must be energized before the guns fire. The customer is required to supply a triggering device (microswitch, photocell, timer, etc) for this purpose. A. Turn the circuit breaker on the applicator off. If there is adhesive in the tank, allow time for it to cool down but not to solidify. CAUTION: Removing the pump after the adhesive has begun to solidify could damage the O-ring on the crossover tube of the pump. P/N 08 59C ONORDSON CORPORATION 993 Issued 9/93
Instructions 6-52 Page 2 Series 3000 O:l Pump Installation Kit 2. Remove the pump enclosure by holding the enclosure and pulling up sharply. DO NOT rock the enclosure back and forth. 3. Set the pump air regulator to zero andshut off a valve upstream of the regulator in the air supply line.. Disconnect the pump inlet air supply line that is attached to the air control valve assembly. 5. Remove the hex head screws and washers that secure the pump and pump mount to the applicator. 6. Rotate the pump slightly in a circular motion to break suction and then pull it straight up to dlisengage the crossover tube from the manifold. A WARNING: Hot adhesive will flow from the pump inlet, outlet, and bleed hole. Wear safety gloves (P/N 902 5), safety glasses, and protective clothing to prevent serious burns,, 7. Remove the electrical cover and the rear panel from the applicator. 8. Disconnect the pump inlet air supply line from the union and connect the new 3/8 PFA tubing (0) using the 3/8 tube nut w/ferrule (2). 9. Check that the pump pan is in the correct position. 0. Hold the new O:l pump assembly () and carefully position the crossover tube of the pump into the inlet port of the manifold. Rotate the pump mount until the bolt holes for the hex head screws line up correctly.. Replace the hex head screws and washers that where removed in Step 5 with the hex head screws (7) and washers (5, 6) provided in this kit. Secure the pump and torque the screws lo- 2 ft-lbs (3.56-6.57 Nm). 2. Apply Never Seez to the threads of the 90 Elbow (3) and connect it to the male elbow (). 3. Apply Never Seez to the threads of the Male Elbow () and connect to the pump as shown in Figure. Issued 993 ONORDSON CORPORATION 993 P/N 08 59 C
Series 3000 O:l Pump Installation Kit Instructions 6-52 Page 3. Apply Never Seez to the threads of the 90 Elbow (3) and secure the solenoid valve (2) to it. 5. Apply Never Seez to the threads of the 3/8 Elbow () and secure it to the solenoid valve (2). 6. Cut the PFA tubing (IO) so that it will reach the 3/8 Elbow () without pulling. Take the! tubing and secure it to the 3/8 Elbow. 7. Remove the front panel from the unit. 8. Push the solenoid wire leads between the tank and the center frame and fish the leads out to the front of the unit. 9. Carefully lay the leads in the notch in the wire channel along with the heater leads. Ru.n the solenoid leads along the wire channel, past the center frame and out into the electrical cabinet. 20. Attach the Push-on Terminal (9) to the end of the solenoid ground lead. Attach the solenoid ground lead to the ground stud located on the base of the electrical cabinet. 2. Connect the solenoid leadls to the back of the Terminal Block (). 22. Take the Terminal Block Bracket (6) and lay the Strip Marker (5) on top. While holding the bracket and strip marker, lay the terminal block on top so that the holes in the terminal block, strip marker and bracket line up. 23. Secure the terminal block to the bracket with the Pan Head Screws (3). 2. Using the HiLo Pan Head Screws (8) and Flat Washers (7), secure the bracket to the center frame. 25. Place the cable straps (9) along the solenoid lead wires to keep them in place. 26. Connect the selected triggering device (microswitch, photocell, timer, etc.) to the front of the terminal block in the same terminals as used in Step 2. 27. Replace the front and rea.r panels and the electrical cover. 28. Restore the applicator to normal operation. P/N 08 59 C ONORDSON CORPOFIATION 993 Issued 9/93
Instructions 6-52 Page Series 3000 O:l Pump Installation Kit Section A-A Center Frame ---a------e --- ---- --- -- Figure - O:l Single Acting Pump Installation Kit Issued 993 ONORDSON CORPORATION 993 P/N 08 59lC
Series 3000 O:l Pump Installation Kit Instructions 6-52 Page 5 O:l Single Acting Pump Installation Kit Parts List Item No. Part Number Description Req d 0 3 598 Installation Kit, O:l Single Acting Kit Pump Assembly, Single Acting 2 98 228 Nut, W/Ferrule, 3/8 Tube 3 982 69 Screw, Pan HD, Sit, M3 x 6 Zn 2 Block, Terminal, Control, Station 5 Strip Marker, StaIion 6 - Bracket, Terminal 3lock, 3000 7 Screw, HiLo, Pan Hd, Ret, 2-8 2 8 Washer, Flat,.09 x.250 2 9 939 0 Strap, Cable,.75 0 D Tubing, PFA, 3/8 2 Ft Elbow, 3/8 Tube x l/8 NPT 2 38 237 Solenoid Valve, 5 VAC/2 VDC 3 973 26 Elbow, Pipe, Hyd, 90, St, l/8 NPT 973 2 Elbow, l/8 NPT, Male 5 983 Washer, Flat Narrow M8 3 6 983 0 Washer, Lock, Split M8 3 7 982 22 Screw, Hex HD, M8 x 30 mm 3 8 900 38 0 Never Seez s 9 933 323 Terminal, Push-on, Hi-Temp P/N 08 596 ONORDSON CORPORATION 993 Issued 9/93
Instructions 6-52 Page 6 Series 3000 O:l Pump Installation Kit Keep your unit going with UptimeTM or Uptime Plus Packs,, covering most maintenance needs with a careful selection of service kits, available at a substantial price discount. Pump D, Uptime TM Pack, P/N 38 230 consists of: 38 50 Service Kit, Ring Retain, Int 38 60 Service Kit, Seal, Pump 38 72 Service Kit, Piston & Screws 38 73 Service Kit, Cup & O-Ring 38 77 Service Kit, Cage, Seat & Ball 38 237 Service Kit, Valve, Sol, 5 VAC/2 VDC Pump D, UptimeTM Plus Pack, P/N 38 235 consists of: Pump D Assembly, Single Acting, with solenoid Issued 9/93 ONORDSON CORPORATION 993 P/N 08 59C
Series 3000 O:l Pump Installation Kit Instructions 6-52 Page 7 Pump D, O:l Single Acting, Parts List Nor&on has created SERVICE KITS to make sure tha,t you can complete any repairs you may need to make. Service kits have been compiled based on our careful analysis of parts typically required to complete repairs of the assembly. We recommend your use of these kits. Refer to the Kit Symbols to identify the kit contents. Nordson Service Kits List Kit Kit No. Symbol Description \ 05 5 05 9 38 63 38 66 38 68 38 7 38 72 38 73 38 77 38 78 38 79 38 80 * Service Kit, Crossover Tube (contains items 25, 26, 27) Service Kit, Locknut & Washer (contains items 3, 32) Service Kit, Check Valve & Ball (contains items 29, 30) Service Kit, Cap Air Cylinder (contains items, 6, 7, 9, 0) Service Kit, Air Cylinder (contains items 0, ) Service Kit, Support Spring (contains items :3, 37, 38) Service Kit, Piston & Screw (contains items 9, 20, 39, 0, ) Service Kit, Cup & C-Ring (contains items 2,,, 5, 6, 0) Service Kit, Cage, Seat & Ball (contains items 22, 23, 2) Service Kit, Spring % Retainer (contains items, 6) Service Kit, Pump Fled & Piston (contains items 5, 9, 20, 39, 0, ) Service Kit, Pump Body & Check Valve (contains items 7, 8, 2, 28, 29, 30) Pump D, O:l Single Acting Pump Parts IList Item Part Kit No. No. Symbol* Description Req d 38 235 Pump D, Uptime Plus, Single Acting w/solenoid 38 76 Piston, Pump, Single Acting, Air (pkg of 2) *The symbols in this column are used to identify the kit in which the part appears. Match these symbols in the parts list to the symbols in the kits list, so you can order the appropriate kit to complete your repair. P/N 08 59C ONORDSON CORPORATION 993 All Rights Resewed Issued 9/93
Instructions Page a 6-52 Series 3000 O:l Pump Installation Kit Item Part Kit No. No. Symbol Description Req d w 2 Cup, Piston, Hi Volume 3 5 6 7 8 9 0 2 3 5 6 7 8 9 20 2 22 23 2 25 26 27 28 29 30 3 32 33 3 35 36 37 38 39 0 3858 386 32685 32686 385 3865 m 09825 m 3869 3859 3850 3860 m s 20375 20376 385 3870 38 3856-389 388 a* * * * *m Washer, Piston Seal, Hi Vol (pkg of ) Bumper, Piston Stop (pkg of 2) Nut, Hex, M6, Steel (pkg of ) Washer, Lock, Split, 6 (pkg of ) Screw, Hex HD, M6 x 20 mm (pkg of ) Stop, Pump, Piston (pkg of 2) Cap, Air Cylinder, Single Acting O-Ring, Viton, 3.75 x 3.88 (pkg of ) Cylinder, Air, Hi Volume Adapter, Air Cylinder, Hi Vol Support, Spring Guide Spring, Comp, Single Acting Pump Rod, Pump, Single Acting Retainer, Spring (pkg of 2) Ring, Retaining, Int,.82, Basic (pkg of ) Seal, Pump (pkg of ) Piston, Pump, Single Acting, Hyd. Screw, Shld., l/-20 Body, Pump, Single Acting Cage, Ball, Siphon Ball, 0 SS,,750 Seat, Siphon Ball x,32 O.D. O-Ring, Viton,,38 x.!563 x.063 (pkg of ) Ring, Back-Up, Single, 7/6 x 9/6 (pkg of ) Tube, Crossover Pin, Groov, Type A,.I25 x.00 Ball, 0 SS,.375 Seat, Ball Check Valve Washer, Lock, Brg, W-08 (pkg of ) Locknut, Mount, Brg, Pn-08 Pump Never Seez, 6 oz Aerosol Can Lubricant, O-Ring, Parker Oz Loctite #620 Washer, Flat, E, Spring Guide Support (pkg of ) Ring, Retaining, l/8 (pkg of ) Plug, Piston O-Ring, Viton,.375 (pkg of ) O-Ring, Viton,.563 (pkg of ) Issued 9/93 ONORDSON CORPORATION 993 P/N 08 59 C
Series 3000 O:l Pump Installation Kit Instructions 6-52 Page 9 P/N 08 596 ONORDSON CORPORATION 993 Issued 9/93