GEIGER-GJ56.. For Venetian blinds and exterior blinds

Similar documents
GEIGER-SOLIDline* GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens. Bedienungsanleitung. Operating Instructions. Manuel d utilisation

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds

GEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds

X-line Raffstore with KNX interface For Venetian blinds and exterior blinds

GEIGER GJ56.. Product Datasheet WITH MECHANICAL OR ELECTRONIC LIMIT STOP. Venetian blind motor series GJ56.. GJ56.. Noise reduction GJ56..

Standard Venetian blind motors. In the past, higher priority was usually given to functionality rather than to the sound power level of the motor.

GEIGER AIR products The sun protection drives of the future

Porte 150 Users Manual Swing Gate Opener 24V DC

Wilo-Control SC-Fire Jockey

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

AXIAL FANS Axis / Tubo OPERATION MANUAL

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

c-go 24V/6A 24V/8A 24V/12A

Chain wheel rolling door drives DKM 170, 250, 350, 500 and 750 WKM 170

RolTop Roller Blind Drive

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Northern Sales & Distribution Centre

Instruction Manual. Caravan Charging System CSV 404. Table of contents

T35 W35. Thermoelectric cooler Instruction Manual 6. Thermoelektrische Kühlbox Bedienungsanleitung 16. Glacière thermoélectrique Notice d emploi 27

Mod: KLD6-12/35XLAS-N

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Assembly and Operating Instructions

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

STÜTZVORRICHTUNG MODUL

Mechanical Operating Instructions

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Multi-Mover Charger for model L25

blue garda blue roll blue roll EAsy blue micro blue micro EAsy moteurs tubulaires motores tubulares Serie - Series - Baureihe - Série - Serie

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Cordless Floor Polisher

English. Instruction and operation manual S 110. Power Meter

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

DEUTSCH 01 ESPAÑOL 43 PORTUGUÊS 71 SUOMI 127

LCD video-goggle with 5,8 GHz diversity receiver HIVR 101

GARDENA. N FIN P E I DK S NL F GB D

28W WORK LAMP Model: CTL28 Part No:

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

Installation instructions BasicRelay CR / / 2012

Originalbedienungsanleitung/Ersatzteilliste 5. Original operating manual/spare parts list 11

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

Mounting and Operating Instructions EB 5868/5869 EN

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

ExitSafe. Operating instructions Retain for future reference _EN_1118

Operating Instructions

Jetpik. Model JP-51M/51/210/250-SOLO Power Floss System

English. Instruction and operation manual S 212. Dew point sensor

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

PowerPlex 40V MAX Standard Battery Pack/Charger

Shaft mounted rolling door drives DFM/DFE 100, 170, 250, 350, 500 and 750 WFM/WFE 170

Assembly and Maintenance Manual Type ASNU

Instruction manual Electric glass door lock Touch-to-open

362 Clamp Meter. Users Manual

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Pedelec Operating Instructions Pedelec handleiding Pédélec manuel

CoolFreeze CFX35, CFX40, CFX50, CFX65, CFX65DZ

Battery Charger JCB- SCH20LI.2

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Instruction manual. CSV 402 caravan power supply. Table of contents

1 Safety instructions. 2 Device components. System Blind control insert with auxiliary input

Aesculap B. Braun VetCare

Operating Instructions AC/Rechargeable Professional Hair Clipper

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Instruction manual and installation guide Traction sheave brake TSB TSB

Sense7-series Non-contact coded safety switch

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

PS Bedienungsanleitung. Symbole 3. D PowerStarter 7. GB PowerStarter 15. E PowerStarter 23. F PowerStarter 31.

WATERFLUX 3070 Quick Start

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

Usage Instructions of Solar Control for 3Way-Ball Valve

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Installation Instructions. Ultimate Screen. English Version 2.3

Operating Instructions CYR52

moteurs tubulaires motores tubulares Serie - Series - Baureihe - Série - Serie BLUE OCEAN

HQUA. UV Water Sterilizer Instruction Manual. Contents

LS-300 lighting stand. user manual

Universal Battery Charger Cat. No.: Instruction Manual

Power consumption In operation At rest For wire sizing

233 True-rms Remote Display Digital Multimeter Safety Information

TECHNICAL GUIDELINES ELECTRO MOTORS

KMR 1200 B (06/99)

WORM GEAR 421F... Information. Radio and control accessories. Operating systems. for Venetian blinds. Operating systems. for rolling shutters

OPERATION & MAINTENANCE INSTRUCTIONS

Cordless Floor Polisher

Operating and mounting instructions AxisDrive

S1200 DC Smart Charger (1 200W) Instruction Manual Bedienungsanleitung Manuel d utilisation Manuale di Istruzioni

Energy-Saving Under-Cabinet Light. Assembly and safety advice Z30802A-BS Z30802B-BS

ELECTRICAL DRIVE. Roller blind system. uadro. single buttons. Motors

Assembly and Maintenance Manual Type AS

Smile 11 RA/-B Smile 12 RF/-G Reset button

General Instructions and Inspection Instructions for Crane

Transcription:

Venetian blind motor: GEIGER-GJ56.. For Venetian blinds and exterior blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original installation and operating instructions XXX Manuel d utilisation XXX Manual de instrucciones XXX Istruzioni per l uso 1

Index 1. General information...2 2. Guarantee...2 3. Safety information...3 4. Intended use...4 5. Assembly note...4 6. Installation instructions...5 7. Setting of the end stops...7 8. Technical data...8 9. Information for the specialist electrician...9 10. Declaration of conformity...9 11. Notes on waste disposal...9 12. What to do if...10 1. General information Dear customer, By purchasing a GEIGER motor you have decided on a quality product from GEIGER. Thank you very much for your decision and the confidence placed in us. Before you put this drive into operation please observe the following safety information. It serves for the prevention of danger and for the avoidance of personal injury and damage to property. Please retain this information for future reference. Suitable for all Venetian blinds and exterior blinds Installation without stops possible 2. Guarantee In the case of incorrect installation contrary to the operating instructions and/ or constructional modification, the legal and contractual guarantee for property damage and product liability lapses. 2 Gerhard Geiger GmbH & Co. KG 100W0599 en 0812

3. Safety information II ATTTION: Important safety information. For personal safety, it is important to follow these instructions. The instructions should be kept. This appliance is not to be used by persons (including children) whose physical, sensorial or mental capacities are impaired, or who have no expe rience or know-how, unless they have been supervised or been given instructions on the use of the appliance by someone who is responsible for their safety. Children must be supervised to make sure they do not play with the appliance. The installation is to be checked regularly for defective balance, wear and damage. Damaged connecting leads must be replaced by the GEIGER connecting lead of the same wire type. During operation observe the danger zone. If people or objects are in the danger zone, do not use the installation. Urgently shut down damaged installations until repair. Unconditionally shut down the unit during maintenance and cleaning operations. Pinching and shearing sites are to be avoided and to be safeguarded against. When operating the manual actuator with the open sun protection system, exercise caution as it can fall down quickly if springs expand or are broken. Do not operate the device if operations such as, for example, window cleaning are to be carried out in the vicinity. Disconnect the device from the mains power supply if operations such as, for example, window cleaning are being carried out in the vicinity. II ATTTION: Important safety information. Follow all installation instructions, as incorrect installation can lead to serious injuries. The motor surface can become very hot during prolonged operation. Please do not touch the motor during the cool down phase. Connection must be carried out by a skilled electrician according to the regulations in force locally. The mains plug of the motor must be accessible after installation. On the installation of the motor without mechanical protection of the driven parts, the motor must be installed at a height of at least 2.5 m above the ground or of another level which provides access to the drive. Before the motor is installed, all leads which are not needed are to be removed and all equipment which is not needed for actuation is to be put out of operation. If the motor is controlled by a switch or pushbutton, the switch or pushbutton must be mounted within eyeshot of the motor. The switch or pushbutton must not be located in the vicinity of moving parts. The height 3

of installa tion must be at least 1.5 m above the floor. If the apparatus is equipped without a pin and a socket connector (STAS3K) in the connecting lead, or other means for disconnecting from the mains with at least a 3 mm contact opening on each pole, a disconnecting device of this type must be incorporated into the permanently installed electrical installation according to the wiring rules. Permanently installed control devices must be attached visibly. The correct dimensioning of the drive is to be observed. The rated sound pressure level is less than 70 db(a). 4. Intended use The motors of the model range GJ56.. with mechanical end stop are designed exclusively for the operation of Venetian blinds and exterior blinds. If the motors are used for other applications and/or modifications are performed to the motors, which have not been discussed with GEIGER Antriebstechnik, then the manufacturer is not liable for personal injury and/or damage to property and for consequential damage. 5. Assembly note When viewed from inside the room, the power supply connection of the GJ56 is located on the left side. The straps Electric mains are wound on the winding rollers from the outside. The adjustment Direction buttons of the limit stop control OP device and the limit stop switch must point downward. The GJ56 which is set to the lower end position when it leaves the factory, is installed in the fully lowered Venetian blind. Thus, adjusting the lower end position is not required. The GJ56 must be installed in alignment with the turning bars. Inside the room It is important that the GJ56.. is installed centrally. Please make sure that the load is evenly distributed. Inclined installation: The inclined installation is permitted till 45 maximum to level. The limit stop switch and the adjustment buttons must point downward. 4 Gerhard Geiger GmbH & Co. KG 100W0599 en 0812

6. Installation instructions II I Prior to installation please check to ensure there is no visible damage to the motor like cracks or open cables. Before fixing please check the strength of the masonry and of the surface. Head rail opening at top: 5

Head rail opening at bottom: i 6 Gerhard Geiger GmbH & Co. KG 100W0599 en 0812

7. Setting of the end stops The GJ56 is equipped with two integrated, adjustable limit switches. If required, the factory settings can be changed at any time as often as you like. II The GJ56 can only be operated with an installed limit stop switch. If required, the GJ56 can be delivered without limit stop switch. Operation with limit stop switch If the GJ56 is to be switched o in the upper end position by means of the limit stop switch, and the GJ56 was installed in the fully lowered Venetian blind as described above, no further settings are required. II Adjustment buttons Limit stop switch Extension Note: The limit stop switch will stop the GJ56.. direction OP only. If you press the DOWN adjustment button for the lower end position and DOWN direction, the Venetian blind can move over the lower turning position and move up again. If the Venetian blind hits the limit stop switch now, the GJ56 is not switched o and the Venetian blind could be damaged. Adjustment of upper end position 1. Move the Venetian blind approx. 300 mm below the required end position. 2. Press the black adjustment button. 3. Move up the Venetian blind to the required end position. 4. Move down the Venetian blind about 6 seconds, until the black adjustment button jumps back audibly (click). Now the upper end position is adjusted. Adjustment of lower end position 1. Move the Venetian blind approx. 300 mm above the required end position. 2. Press the white adjustment button. 3. Move down the Venetian blind to the required end position. 4. Move up the Venetian blind about 6 seconds until the white adjustment button jumps back audibly (click). Now the lower end position is adjusted. 7

geprüfte Sicherheit geprüfte Sicherheit 8. Technical data Technical data GJ56.. with mechanical end stop (standard mechanical) GJ5603k GJ5606k GJ5610 GJ5620 Voltage 230 V~/50 Hz 230 V~/50 Hz 230 V~/50 Hz 230 V~/50 Hz Current 0,40 A 0,40 A 0,60 A 0,85 A Cos Phi (cosj) > 0,95 > 0,95 > 0,95 > 0,95 Inrush current x 1,2 x 1,2 x 1,2 x 1,2 (factor) Power 90 W 93 W 135 W 190 W Torque 3 Nm 6 Nm 10 Nm 2 x 10 Nm Speed 26 rpm 26 rpm 26 rpm 26 rpm Protection class IP 54 IP 54 IP 54 IP 54 Limit switch range 80 rotations 80 rotations 80 rotations 80 rotations Operating mode KB 4 min KB 4 min KB 4 min KB 4 min Length 299 mm 299 mm 309 mm 336 mm Diameter 55 mm 55 mm 55 mm 55 mm Weight approx 1,50 kg approx 1,50 kg approx 1,70 kg approx 2,2 kg Subject to technical modifications DE V Technical data GJ56.. with mechanical end stop (run-time optimized version) GJ5606 GJ5616 Voltage 230 V~/50 Hz 230 V~/50 Hz Current 0,40 A 0,70 A Cos Phi (cosj) > 0,95 > 0,95 Inrush current x 1,2 x 1,2 (factor) Power 90 W 150 W Torque 6 Nm 2 x 8 Nm Speed 26 rpm 26 rpm Protection class IP 54 IP 54 Limit switch range 80 rotations 80 rotations Operating mode KB 6 min KB 6 min Length 304 mm 336 mm Diameter 55 mm 55 mm Weight approx 1,60 kg approx 2,20 kg Subject to technical modifications DE V 8 Gerhard Geiger GmbH & Co. KG 100W0599 en 0812

9. Information for the specialist electrician HH Caution: Wrong installation and wrong connection can lead to serious injuries. Because of back-voltage of the capacitor, the parallel connection of the GJ56.. is not permissible. If two GJ56.. are operated in parallel, a 2-pole switch or a suitable cut-o relay must basically be used. Please do not use any installation switch which allows simultaneous up and down controls. Please do not use PVC cables to connect the GJ56.. They are not suitable for equipment used outdoors or exposed to prolonged high levels of UV radiation. Connecting cables with plug connectors of the Hirschmann Company, type STAS 3K, may only be used in connection with the Hirschmann cable socket STAK 3K. 10. Declaration of conformity We herewith explicitly declare that this product complies with the essential requirements and relevant directives. It is authorised for use in all EC member states and in Switzerland without any need of prior registration. The Declaration of Conformity concerning this product is available on our website:. L1 N PE Mains: 230V / 50Hz PE green/yellow N 1 2 3 blue brown black Electronic / mechanical limit stop 11. Notes on waste disposal Recycling of packaging materials In the interest of environmental protection, please contact your local government s recycling or solid waste management department to learn more about the services it provides. Waste disposal of electric and electronic equipment Electronic equipment or batteries cannot be discarded along with the normal household waste. Keep for more information on the recycling and disposal methods envisaged by the local regulations in your area. 9

12. What to do if Problem Motor does not run. Instead of in the upwards direction, motor runs downwards. Motor only runs in one direction. After running several times, the motor breaks down and no longer responds. The blind is in the upper end position, actuates the limit stop switch and can no longer move downward. Solution Motor not plugged in. Please check the plug connection. Check connecting cable for possible damage. Check the mains voltage and allow the cause of the voltage break down to be tested by a specialist electrician. The control leads are interchanged. Exchange black/brown control leads. Motor in the end position. Run motor in the opposite direction. The motor became too hot and has switched o. Try it again after a cooling time of about 15 min. The motor has been installed upside down or the lower end stop has been overrun and the straps are wound up the wrong way. Restore free motion of the limit stop switch. Re-adjust the end positions For technical questions, please call our service team at: +49 (0) 7142 938-300. They will be happy to assist you. Gerhard Geiger GmbH & Co. KG Schleifmühle 6 D-74321 Bietigheim-Bissingen Telephone: +49 (0) 7142 938-0 Telefax: +49 (0) 7142 938-230 info@geiger-antriebstechnik.de 10 Gerhard Geiger GmbH & Co. KG 100W0599 en 0812