Palletized Fixture Accessories

Similar documents
NEW PRODUCTS PRECISION HYDRAULIC CLAMPING. Metric Slip-in Cartridge. 360 Link Clamp. Confirmation Valve

Accessory Valves. Frequently Asked Questions

Miscellaneous Plumbing

Cylinders. Standard Features F-1. Frequently Asked Questions, Features

TuffCam Swing Clamps C-1. Frequently Asked Questions

TuffCam Swing Clamps C-1. Frequently Asked Questions

Power Supplies. Hydraulic Oil ISO 32 Grade

POWER CLAMPING.

POWER CLAMPING. Power Clamping. Air-Powered Hydraulic Pumps

Fracturing Equipment Lubrication Kits

Contact Force (lb.) Stroke (in.) Fluid Advance Work Supports, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks 0.

DME Valve Gate Controls

FUNDAMENTAL TECHNICAL HYDRAULIC CLAMPING INFORMATION

We shut the air supply down to our clamps once they are in position. Sometimes we notice that they are sticking. Could this be the cause?

HOW THE SPRAGUE PRODUCTS BOOSTERS WORK

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

P O W E R P U M P S SECTION INDEX. Proper Size & Selection G1 Series Electric...

VEKTEK PARTS LIST THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL AT REVISION C AND LATER REVISIONS.

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

Monarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category.

January 2007 Approval Guide Fixed Extinguishing Systems 5-57

OPERATION AND PARTS MANUAL

Wedge clamps

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

CRITICAL SUCCESS FACTORS

Rodney Hunt. A GA Industries Company Hydraulic Actuation

Directional Control Valves

Hydraulic Actuation Reliability, Flexibility, and Performance

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

N-Line Valves. Surface Stepping Actuators

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

/2017. Swing sink clamping element double-acting

GENERAL PUMPA member of the Interpump Group


Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

Directional Control Valves

2/2 Solenoid Cartridge Valve, Size 10

Air Driven Gas Boosters

NFPA Style Hydraulic Rod Clamps RCH SERIES ROD LOCKS

PRODUCT CATALOG COMPACT HYDRAULIC SPACE-SAVING, LONG-LASTING DEVICES FOR DEMANDING DESIGN REQUIREMENTS.

Prism PI Intelligent features offer advanced performance

Control Valves & Valve Accessories

TuffCam 7 MPa Swing Clamps

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

KJ4000LW Operating Instructions & Parts Manual NSN

Open Center Compact Valve Custom Installation Guide Rev A

40, 45 & 47 SHAFTS ONL

1/8 NPT (F) 1/8 NPT (F)

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR Cat Tractors with standard shoe/drum brakes

SureFire II Lubricator

MANUAL PALLET VALVE # Manifold Mount Outlet Port # /16-20 UNF SAE-4 Outlet Port # /4 NPT Outlet Port Max. Capacity: 5,000 PSI

Morin series S actuator

PUMP ACCESSORIES. Pump Accessories 40,000 PSI

TECHNICAL DATA 1-1/2 (dn40)

3PC Directional Control Valves

Portable Equipment High-Pressure Heavy-Duty Grease Pumps

ROGERS MACHINERY COMPANY, INC

Digital Manifold with Digital Hydrant Control

SECTION B: SYSTEM OPERATING COMPONENTS

LubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems

Push/Pull Cylinders G-1. Frequently Asked Questions. Frequently Asked Questions, Features

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

Dynaswivel. Air Line Connectors. Ball-Swivel Plug. Never Fight an Air Tool Again! For Use with Most Air Tools THE PROBLEM THE SOLUTION

HARDINGE Collet Blocks

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

SECTION B1: MACHINE COMPONENTS

PNEUMATIC 180 ANGULAR GRIPPER

STRETCH ROD CYLINDERS for Krones Stretch Blow Molding Machines

AccessoriesAccessories

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

INSTALLATION INSTRUCTIONS

POR SERIES Pneumatic Overload Release Clutches

91 \\SERVER\CATALOG 2018\2018 Catalog Rev 1 SHUT OFF BALL VALVE

VEKTEK PARTS LIST. Copyright by Vektek, Inc.

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TotalPac 3 Deluge system Pneumatic release

Electric Actuators Maximum in-lbs

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website

Electric Actuators Maximum in-lbs

Type 2000 Transducer Product Instructions

Skotch Trifecta Oil Valve System

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Service and Parts Manual. Minimum Filtration Required:

hand pumps HAND PUMPS

4-Way Directional Control Valve With Hydraulic Kick Out

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

KVF. Flow Control Servovalve (FCS) DESCRIPTION FEATURES ORDERING INFORMATION KVF X X X X X. BLN Issued: February 2004

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø

Transcription:

Frequently Asked Questions Some questions about pallet and tombstone clamping systems are common to both novices and experienced users. The answers to the following questions may help you better understand palletized hydraulic systems. Contact Vektek for assistance in determining if you should use a decoupled fixture or leave the fixture connected to the pump. What is a pallet decoupler and what is its purpose within a clamping system? A pallet decoupler is a device which serves as the interface between the stationary pump and the moving pallet. This is the point where the hose(s) from the pump is connected and disconnected from the pallet. The decoupler rides along on the pallet and is the regulator of pressurized hydraulic fluid for the clamping circuit while it is disconnected from the pump. A decoupler must contain a shutoff valve to trap pressurized fluid from the pump within the clamping circuit and allow the hose(s) to be disconnected from the pallet. A decoupler must also contain: * A coupler(s) for connecting the hose(s). * Filter screens to minimize the amount of contamination that enters the pallet hydraulic circuit. * An Accumulator to store pressurized hydraulic fluid. The accumulator maintains pressure to the clamping circuit while the pallet is disconnected from the pump. * Ports for connection of the pallet hydraulic circuit. * May include a pressure gauge and an over-pressure relief valve. What are the types of pallet decouplers? We divide pallet decouplers into two basic types based on whether the shutoff valve operates automatically or manually. In Manual Shutoff Valve Decouplers the operator manually closes the shutoff valve to trap pressure on the pallet (to keep the parts clamped) and manually opens it to release pressure from the pallet (unclamp the parts). Manual Shutoff Valve Decouplers require the operator to control the pump to pressurize the pallet and release pressure from the hose(s) for disconnection. For ease of operation, most Manual Shutoff Valve Decouplers are used with single acting clamp systems or circuits. Automatic Shutoff Valve Decoupler the shutoff valve is actuated by Clamp and Unclamp pressures from the pump. The operator only needs to control the pump. Automatic Shutoff Valve Decouplers are used with both single and double acting circuits with equal ease. What is the difference between a pallet decoupler and a Tombstone Top Plate? A Tombstone Top Plate is an expanded type of Manual Shutoff Valve Decoupler. A decoupler has one shutoff valve to control one pallet circuit. A tombstone top plate has multiple shutoff valves to provide separate control of each single acting circuit (face). A common accumulator keeps all circuits pressurized when the tombstone is disconnected from the pump. Tombstones that require double acting clamping circuits must use one Automatic Shutoff Valve Decoupler per face or circuit. If I don t have enough space for a decoupler (or top plate) with its accumulator, can I use just a shutoff valve and a disconnect coupler? Absolutely not, every hydraulic clamping pallet and tombstone must have an accumulator to be safe! We offer decouplers with integral accumulators to minimize their size, and decouplers and top plates that allow the accumulator to be located in a place on the pallet or tombstone that has more space. In addition, we can provide all the individual components required to implement a distributed decoupling system to safely conform to your space limits. Frequently Asked Questions What type of pump do I need to operate decouplers and Tombstone Top Plates? Manual Shutoff Valve Decouplers and Tombstone Top Plates require an on-demand pump that includes a 2-Position 3-Port directional control valve and a mating coupler with suitable hose. Automatic Shut off Valve Decouplers require an on-demand pump that includes a 3-Position 4-Port pressure blocked center directional control valve and a decoupler Operating Handle with suitable hoses. Pumps for palletized fixtures must be configured to de-pressurize the hose(s) for connection and disconnection. See Basic Pump recommendations for each type of decoupler on the following pages. Pumps can also be configured to operate any combination of Manual Shutoff and Automatic Shutoff Valve Decouplers and Top Plates. Most users prefer pendant controlled, pump mounted, and electric control valves for decoupling operations. However, pumps can be configured for remote mounted electric and manual control valves, and with valves for integration into the machine control or machining cell PLC (Programmable Logic Control). Pumps can be set-up with an automatic Pressure Monitoring System to assure that the pallet and tombstone fixture are properly pressurized before entering the machine. Pump operations can be set to deliver a different operating pressure to each pallet and tombstone and to deliver different pressures to the clamp/unclamp side of double acting circuits. Contact Vektek for technical assistance. www.vektek.com 800-992-0236 Vektek, February 2017 K-1

Automatic Shutoff Valve Decouplers, One-Handed Operating Handle Automatic Shutoff Valve Decouplers for Single and Double Acting Systems New Check Valve Decouplers are a convenient, self-contained package that includes quick connect couplings, filters, pilot operated check valve, and an over pressure relief valve. Contains a robust pilot operated check valve with a 1:5 pilot to check ratio for proven long term reliability. Internal 25 micron filters for added protection of the pilot operated check valve through ports A1, A2, A3, A4, and C1. Extra filtration at port B1. No filtration at remaining ports. (replacement filter kits 62-5600-05 or 62-5600-06 for a manifold mount configuration) Integral accumulator available in two operating pressure ranges. SAE female external ports and manifold mounting (bottom and rear) connections. Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release. For single hose systems see the Manual Shutoff Valve Decouplers, page K-9 and K-10. Optional return port B filtration page M-7. Decouplers with Integral Accumulator Pressure Accumulator Range (psi) Capacity B Return Port Filter B3 B4 56-0005-23 1,000-3,500 3.6 cu. in. 70-0401-71 70-0437-71 56-0005-24 2,000-5,000 3.2 cu. in. 70-0401-71 70-0437-71 For use with Operating Handle 56-0008-00 K-2 One-Handed Operating Handle 56-0008-00 For use with Decoupler Nos. 56-0005-23, 56-0005-24, 56-0005-25 or 56-0005-26 Provides a fast, positive connection to the Decoupler. Ergonomic design reduces operator fatigue. For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in. R a surface finish. NOTES: Field repair requires a special Check Valve Installation Tool. Please order 65-6000-00 NOTE: These Automatic Shutoff Valve Decouplers and Operating Handle must be used with a suitable pump (see page K-3) which includes a 3-Position/4-Port, P-Blocked center ( A & B connected to Tank ) directional control valve for operation of single or double acting systems. One Automatic Shutoff Decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the Decoupler port B (as shown in the schematic). Vektek, February 2017 800-992-0236 www.vektek.com

Automatic Shutoff Valve Decouplers for Single and Double Acting Systems Decouplers are a convenient, self-contained package that includes quick connect couplings, filters, pilot operated check valve, accumulator and an over pressure relief valve. Robust pilot operated check valve with a 1:5 pilot to check ratio for proven long term reliability. Internal 25 micron filters for added protection of the pilot operated check valve through ports A1, A2, A3, A4, and C1. Extra filtration at port B1. No filtration at B2, B3, and B4 ports. (Replacement filter kits 62-5600-05 or 62-5600-06 for a manifold mount configuration) External accumulator available in two operating pressure ranges. Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release. For single hose systems see the Manual Shutoff Valve Decoupler, page K-9 and K-10. Optional return port B filtration page M-7. Decouplers with Integral Accumulator Pressure Accumulator Range (psi) Capacity B Return Port Filter B4 B5 56-0005-25 1,000-3,500 3.6 cu. in. 70-0401-71 70-0437-71 56-0005-26 2,000-5,000 3.2 cu. in. 70-0401-71 70-0437-71 Palletized Fixture Accessories Automatic Shutoff Valve Decouplers, One-Handed Operating Handle For use with Operating Handle 56-0008-00. Pumps for Automatic Shutoff Valve Decouplers A. Basic Automatic Shutoff Valve Decoupler Pump: Workholding pump with one 3-Position/4-Port, P-Blocked center directional control valve and 3-Position pendant switch providing Clamp-Disconnect-Unclamp control (all detented) of the palletized circuit. See page J-11 for standard features of all Workholding pumps. 115 VAC, 1 Phase 55-9242-09-1 230 VAC, 3 Phase 55-9272-09-1 460 VAC, 3 Phase 55-9292-09-1 B. Workholding pump with an adjustable clamp and unclamp pressure regulator used with a 3-Position/4-Port P-Blocked center valve. The valve is pendant controlled. Pendant switch must be held in either clamp or unclamp condition to fully cycle devices. Devices will stop when the pendant is released. 115 VAC, 1 Phase 55-9242-65-1 230 VAC, 3 Phase 55-9272-65-1 460 VAC, 3 Phase 55-9292-65-1 C. Other Automatic Shutoff Valve Decoupler Pumps: Vektek offers a matrix of pumps with a wide range of electric and hydraulic control features for use with the Automatic Decouplers. Contact Vektek with your specific needs for technical support on other suitable pump configurations. NOTE: These automatic Shutoff Valve Decouplers and Operating Handle must be used with a suitable pump (see chart above) which includes a 3-Position/4-Port, P-Blocked center ( A & B connected to Tank ) directional control valve for operation of single or double acting systems. One Automatic Shutoff Valve Decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the Decoupler port B (as shown in the schematic). For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in. R a surface finish. NOTES: Field repair requires a special Check Valve Installation Tool. Please order 65-6000-00 Optional Custom-molded 0.190" riser is available. Please order 45-6005-11 separately. K-3 www.vektek.com 800-992-0236 Vektek, February 2017

Automatic Shutoff Valve Decouplers, Two-Handed Operating Handle New 25 Micron Filters Decouplers with Integral Accumulator Pressure Range (psi) Accumulator Capacity B Return Port Filter B3 B4 56-0005-17 1,000-3,500 3.6 cu. in. 70-0401-71 70-0437-71 56-0005-18 2,000-5,000 3.2 cu. in. 70-0401-71 70-0437-71 For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in. R a surface finish. Automatic Shutoff Valve Decouplers for Single and Double Acting Systems Decouplers are a convenient, self-contained package that includes quick connect couplings, filters, pilot operated check valve, an over pressure relief valve. Robust pilot operated check valve with a 1:5 pilot to check ratio for proven long term reliability. Internal 25 micron filters for added protection of the pilot operated check valve through ports A1, A2, A3, A4, and C1. Extra filtration at port B1. No filtration at remaining ports. (replacement filter kits 62-5600-05 or 62-5600-06 for a manifold mount configuration) Integral accumulator available in two operating pressure ranges. SAE female external ports and manifold mounting (bottom and rear) connections on all models. Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release. For single hose systems see the Manual Shutoff Valve Decoupler, page K-9 and K-10. Optional return port B filtration page M-7. K-4 Two-Handed Operating Handle 56-0005-04 For use with Decoupler s 56-0005-17, 56-0005-18, 56-0005-19 or 56-0005-20 NOTES: Field repair requires a special Check Valve Installation Tool. Please order 65-6000-00 NOTE: These automatic Shutoff Valve Decouplers and Operating Handle must be used with a suitable pump (see page K-5) which includes a 3-Position/4-Port, P-Blocked center ( A & B connected to Tank ) directional control valve for operation of single or double acting systems. One Automatic Shutoff Decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the Decoupler port B (as shown in the schematic). Provides fast, positive connection to the Decoupler. The Two-Handed Handle may be used with the optional Handle Docking Module (page K-7) to assure that the hoses are disconnected from the pallet before it is shuttled into the machine. Vektek Pumps for Automatic Shutoff Valve Decouplers inset on page K-5, bullet A, are recommended for use with this handle. Vektek, February 2017 800-992-0236 www.vektek.com

Automatic Shutoff Valve Decouplers for Single and Double Acting Systems Decouplers are a convenient, self-contained package that includes quick connect couplings, filters, pilot operated check valve, accumulator and an over pressure relief valve. Robust pilot operated check valve with a 1:5 pilot to check ratio for proven long term reliability. Check valve through ports A1, A2, A3, A4, and C1. Extra filtration at port B1. No filtration at remaining ports. (replacement filter kits 62-5600-05 or 62-5600-06 for a manifold mount configuration) External accumulator available in two operating pressure ranges. SAE female external ports and manifold mounting (bottom and rear) connections. Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release. For single hose systems see the Manual Shutoff Valve Decoupler, page K-9 and K-10. Optional return port B filtration page M-7. Decouplers with Integral Accumulator Pressure Accumulator B Return Port Filter Range (psi) Capacity B4 B5 56-0005-19 1,000-3,500 3.6 cu. in. 70-0401-71 70-0437-71 56-0005-20 2,000-5,000 3.2 cu. in. 70-0401-71 70-0437-71 For use with Operating Handle 56-0005-04. NOTE: Field repair requires a special Check Valve Installation Tool. Please order 65-6000-00. Optional Custom-molded 0.190 in. riser is available. Please order # 45-6005-11 order separately. Palletized Fixture Accessories Automatic Shutoff Valve Decouplers, Two-Handed Operating Handle Pumps for Automatic Shutoff Valve Decouplers A. Basic Automatic Shutoff Valve Decoupler Pump: Workholding Pump with one 3-Position/4-Port, P-Blocked center directional control valve and 3-Position pendant switch providing Clamp-Disconnect-Unclamp control (all detented) of the palletized circuit. See page J-11 for standard features of all Workholding Pump. 115 VAC, 1 Phase 55-9242-09-1 230 VAC, 3 Phase 55-9272-09-1 460 VAC, 3 Phase 55-9292-09-1 B. Workholding Pump with an adjustable clamp and unclamp pressure regulator used with a 3-Position/4-Port P-Blocked center valve. The valve is pendant controlled. Pendant switch must be held in either clamp or unclamp condition to fully cycle devices. Devices will stop when the pendant is released. 115 VAC, 1 Phase 55-9242-65-1 230 VAC, 3 Phase 55-9272-65-1 460 VAC, 3 Phase 55-9292-65-1 C. Other Automatic Shutoff Valve Decoupler Pumps: Vektek offers a matrix of pumps with a wide range of electric and hydraulic control features for use with the Automatic Decouplers. Contact Vektek with your specific needs for technical support on other suitable pump configurations. For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in R a surface finish. NOTE: These automatic Shutoff Valve Decouplers and Operating Handle must be used with a suitable pump which includes a 3-Position/4-Port, P-Blocked center ( A & B connected to Tank ) directional control valve for operation of single or double acting systems. One Automatic Shutoff Decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the Decoupler port B (as shown in the schematic). K-5 www.vektek.com 800-992-0236 Vektek, February 2017

Automatic Shutoff Valve Decouplers, Two-Handed Operating Handle with Air Automatic Shutoff Valve Decouplers for Single and Double Acting Systems Decouplers are a convenient, self-contained package that includes quick connect couplings, filters, pilot operated check valve, accumulator and over pressure relief valve and separate path for compressed air. Internal 25 micron filters for added protection of the pilot operated check valve through ports A1, A2, A3, A4, and C1. Extra filtration at port B1. No filtration at remaining ports. (replacement filter kits 62-5600-05 or 62-5600-06 for a manifold mount configuration) Robust pilot operated check valve with a 1:5 pilot to check ratio for proven long term reliability. Internal 25 micron filters for added protection of the pilot operated check valve. SAE female external ports and manifold mounting (bottom and rear) connections. Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release. For single hose systems see the Manual Shutoff Valve Decoupler, page K-9 and K-10. Optional return port B filtration page M-7. Handle for this Decoupler unit on page K-7. Decouplers with Integral Accumulator Pressure Range (psi) Accumulator Capacity B Return Port Filter B4 B5 56-0005-21 1000-3500 3.6 cu. in. 70-0401-71 70-0437-71 56-0005-22 2000-5000 3.2 cu. in. 70-0401-71 70-0437-71 K-6 A1, Clamp Quick Coupler Pneumatic Quick Coupler B1, Unclamp Quick Coupler SAE 6 PORT ILS560018 REV H NOTES: Field repair requires a special Check Valve Installation Tool. Please order 65-6000-00. Optional Custom-molded 0.190" riser is available. Please order 45-6005-11, separately. Recommended pumps see Page K-5 For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in. R a surface finish. Two-Handed Operating Handle with Air 56-0007-01 For use with Decoupler s 56-0005-21 and 56-0005-22 NOTE: This Automatic Shutoff Valve Decoupler and Operating Handle must be used with a suitable pump (see blue inset on K-5) which includes a 3-Position/4-Port, P-Blocked center ( A & B connected to Tank ) directional control valve for operation of single or double acting systems. One Automatic Shutoff Decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the Decoupler port B (as shown in the schematic). Vektek, May 2017 800-992-0236 www.vektek.com

Handle Docking Stations with optional feedback sensor Docking Stations are now available for both 1-Handed or 2-Handed Automatic Shutoff Pallet Decoupler Handles. These handy devices provide a standard contamination-free location for quick-disconnect handle storage. Handle Docking Stations have a drain pan to keep your work area free of slip and fall hazards created by dripping disconnects. The optional Proximity Switch confirms the decoupler handle and hoses are connected to the docking station. The pallet can then be safely shuttled into the machine. Adjustable five connector positions insure these stations are ergonomically friendly for all operators. Couplers are BHC treated for long life. Flexible mounting allows for vertical, horizontal or pole applications. 20.7 18.4 4X.281 Decoupler Docking Station Proximitiy Switch Size A Proximity Switch Height B Dock Width 56-0005-28 No Two- Hand N/A 4.37 56-0005-29 Yes Two Hand 1.036 4.37 56-0008-01 No One-Hand N/A 2.95 56-0008-02 Yes One-Hand 0.682 2.95 2X 3.562 MOUNTING HOLES FOR 1/4-20 BOLTS Handle Docking Station 2X 1.500 B GUIDE PIN WITH ONE-HANDED MODEL ONLY.656 A.553 4X.341 SLOT HEIGHT 4.106 4.659 K-7 1.988 FEMALE M12 TO PIGTAIL END EXTENSION CABLE 2.185 1/4 NPT 3.750 1.875 4.371 Horizontal Mounting PROXIMITY SWITCH PIN OUT: PIN 2 PIN 1 EXTENSION CABLE PIN OUT: PIN 1 PIN 2 Mounting Hardware Not Included PIN 3 PIN 4 M12 MALE CONNECTION PROXIMITY SWITCH WIRE DIAGRAM 1 BROWN 4 BLACK LOAD PIN 4 PIN 3 PIN 5 M12 FEMALE CONNECTION SENSOR FEATURE: NORMALLY OPEN CONTACT LED INDICATOR LIGHT 10 TO 36 VDC OPERATING RANGE 100 ma OPERATING CURRENT Approx. 78.7 in. Cordset PIN 1: BROWN (+) PIN 2: WHITE (NOT CONNECTED) PIN 4: BLACK (N/O) PIN 3: BLUE (NOT CONNECTED) PIN 5: GREEN/YELLOW (NOT CONNECTED) ILS560030 REV A Vertical Mounting ILS560028 Pole Mounting REV A www.vektek.com 800-992-0236 Vektek, May 2017

Accumulators Accumulators* Maintains circuit pressure while the pallet or tombstone fixture is disconnected from the pump using a decoupler or tombstone Top Plate. Piston-type, inert gas precharged accumulators compensate for pallet pressure changes during machining. Available in three operating ranges provide up to 3.8 cu. in. of pressure fluid reserve. Hydraulic fluid compresses the precharged inert gas across the piston during circuit pressurization. The pressurized gas provides additional fluid to the circuit to reduce pressure changes in the event of small seeps, or thermal expansion/contraction while the pallet or fixture is in the machine. The 2,000-5,000 psi operating pressure model has gas precharged to 1,500 psi. The 1,000-3,500 psi operating pressure model has gas precharged to 750 psi. Perform annual maintenance in accordance with the instructions provided with each accumulator. Contact Vektek for additional copies of the annual maintenance instructions or to arrange for factory performed annual maintenance. Strictly observe all safety precautions provided with each accumulator. Small System Accumulators Same functions as the larger accumulators above, except for smaller total volume circuits. For system operating pressures of 2,000-5,000 psi unit will provide up to 1 cu. in. of pressurized fluid reserve. K-8 *NOTE: Accumulator s gas precharge must be checked annually. Consult Vektek for technical assistance. Accumulator System Operating Pressure Range Approximate Useable Volume At Maximum System Pressure 10-1014-01 2,000-5,000 psi 1.0 Cubic Inch 10-1014-02 1,000-3,500 psi 1.0 Cubic Inch 10-1016-01 2,000-5,000 psi 3.2 Cubic Inch 10-1016-02 1,000-3,500 psi 3.6 Cubic Inch 10-1016-03 300-1,450 psi 3.8 Cubic Inch Vektek, February 2017 800-992-0236 www.vektek.com

Manual Shutoff Valve Decouplers Manual Shutoff Valve Decoupler for Single Acting Systems This Decoupler is a convenient, self-contained package that includes a quick connect coupling, manual shutoff valve with handle, accumulator (choose from horizontal or vertical arrangement), filter screen, pressure gauge, and over-pressure relief valve. s available for circuits operating at 2,000-5,000 psi and 1,000-3,500 psi with standard and small accumulators. Includes auxiliary ports that can be used for double acting pallet circuits or compressed air. Decoupler with External Accumulator For operation with Female Quick Connect Coupling 30-7827-66 (page H-6) Vertical Accumulator Manual Shutoff Valve Decoupler Pressure Range Accumulator Capacity (psi.) (cu. in.) 56-0001-01 2000-5000 3.2 6.91 56-0001-02 1000-3500 3.6 6.91 56-0001-03 2000-5000 1.0 5.72 A Horizontal Accumulator Manual Shutoff Valve Decoupler * Depending on where the Decoupler is mounted, a spacer (not furnished) may be needed to offset the overhang of the accumulator. Pressure Range Accumulator Capacity A B Min (psi.) (cu. in.) 56-0002-01 2000-5000 3.2 14.47 0.50 56-0002-02 1000-3500 3.6 14.47 0.50 56-0002-03 2000-5000 1.0 13.28 0.25 K-9 Pumps for Manual Shutoff Valve Decouplers A. Basic Manual Shutoff Valve Decoupler Pump: Workholding Pumps with one 2-Position/3-Port, normally closed directional control valve and 2-Position pendant switch providing Clamp-Unclamp/Disconnect control (both detented) of the palletized single acting circuit. See page J-11 for standard features of all Workholding pumps. 115 VAC, 1 Phase 55-9242-33-1 230 VAC, 3 Phase 55-9272-33-1 460 VAC, 3 Phase 55-9292-33-1 B. Other Manual Shutoff Valve Decoupler Pumps: Vektek offers a matrix of pumps with a wide range of electric and hydraulic control features for use with the Manual Shutoff Decouplers to control both single and double acting circuits. Contact Vektek with your specific needs for technical support on other suitable pump configurations. NOTE: This Manual Shutoff Valve Decoupler must be used with a suitable pump (see chart at left) which includes a 2-Position/3-Port, directional control valve for operation of one single acting circuit. Contact Vektek for considerations in the use of this Manual Shutoff Decoupler to control double acting circuits. Also see the Automatic Shutoff Valve Decouplers on pages K-2 through K-6. For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in. R a surface finish. www.vektek.com 800-992-0236 Vektek, February 2017

Manual Shutoff Valve Decouplers, Self-Closing Valve Single Acting Manual Shutoff Valve Decoupler with Self-Closing Valve Decoupler with External Accumulator For operation with Female Quick Connect Coupling 30-7827-66. K-10 This Decoupler is a convenient, self-contained package that includes a male quick disconnect with dust cover, accumulator, filter screens on both sides of system, and an over-pressure relief valve. (Pressure gauge sold separately see page M-18.) Manual shutoff valve automatically closes on system pressurization. Valve is manually opened to release system pressure back to the pump. External accumulator can be repositioned into your decoupler mounting and pallet layout. Manifold mountable from the bottom or the rear surface. External accumulator can be repositioned into ports A3, A6, or A7 to accommodate the decoupler mounting and pallet layout. Pressure gauge can be mounted in A5 or A8 port to accommodate the decoupler mounting and pallet layout. BHC Finish. S/A Decoupler Self-closing Valve System Operating Pressure Min Max Accumulator Quick Connect Part 56-0006-06 2,000 psi 5,000 psi 10-1016-01 30-7727-66 56-0006-07 1,000 psi 3,500 psi 10-1016-02 30-7727-66 For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in. R a surface finish. NOTE: This Self-closing Manual Shutoff Valve Decoupler must be used with a suitable pump which includes a 2-Position/3-Port, directional control valve for operation of one single acting circuit. Vektek, February 2017 800-992-0236 www.vektek.com

Manual Shutoff Valves Top Plate, Four-Sided Manual Shutoff Tombstone Top Plate for Single Acting Systems Provides separate unclamp control of up to four faces of a tombstone or multi-circuit pallet for independent loading and unloading. Tombstone Top Plates are convenient, self-contained packages that include a quick connect coupling, manual shutoff valves, accumulator, filter screens, check valves, pressure gauge(s), and a manual pressure bleed port. The Four-sided Tombstone Top Plate is provided with one common pressure gauge and auxiliary ports for optional pressure gauges at each shutoff valve. s available for circuits operating at 2,000-5,000 psi and 1,000-3,500 psi pressures. Four-Sided Tombstone Top Plate Range 56-0003-01 2,000-5,000 psi 56-0003-02 1,000-3,000 psi For Operation with Female Quick Connect Coupling No, 30-7827-60 (page H-6) K-11 A. Basic Manual Shutoff Valve Top Plate Pump: Workholding pump with one 2-Position/3-Port, normally closed directional control valve and 2-Position pendant switch providing Clamp-Unclamp/Disconnect control (momentary-detent) of the column single acting circuits. These pumps RUN only when the pendant switch is held in the Clamp position. See page J-11 for standard features of all Workholding pumps. 115 VAC, 1 Phase 55-9242-35-1 230 VAC, 3 Phase 55-9272-35-1 460 VAC, 3 Phase 55-9292-35-1 B. Other Manual Shutoff Valve Decoupler Pumps: Vektek offers a matrix of pumps with a wide range of electric and hydraulic control features for use with the Manual Shutoff Valve Top Plates. Contact Vektek with your specific needs for technical support on other suitable pump configurations. NOTE: These Manual Shutoff Valve Top Plates must be used with a suitable pump (see chart) which includes a 2-Position/3-Port, directional control valve for operation of single acting circuits only. Each valve on a Manual Top Plate can be used to operate only one single acting circuit. For operation of double acting circuits, see the Automatic Shutoff Valve Decouplers on pages K-2 through K-6. www.vektek.com 800-992-0236 Vektek, February 2017

Manual Shutoff Valves Top Plate, Two-Sided Manual Shutoff Valve Tombstone Top Plates for Single Acting Systems Provides separate unclamp control of up to two faces of a tombstone or multi-circuit pallet for independent loading and unloading. Tombstone Top Plates are convenient, self-contained packages that include a quick connect coupling, manual shutoff valves, accumulator, filter screens, check valves, pressure gauge, and a manual pressure bleed port. The Two-sided Top Plate is provided with a gauge at each shutoff valve. s available for circuits operating at 1,000-5,000 psi and 1,000-3,500 psi. K-12 Two-Sided Tombstone Top Plate No Circuits Operating at 56-0004-01 2,000-5,000 psi 56-0004-02 1,000-3,500 psi For operation with Female Quick Connect Coupling 30-7827-60 (page H-6). NOTE: These Manual Shutoff Valve Top Plates must be used with a suitable pump (see page K-11) which includes a 2-Position/3-Port, directional control valve for operation of single acting circuits only. Each valve on a Manual Top Plate can be used to operate only one single acting circuit. For operation of double acting circuits, see the Automatic Shutoff Valve Decouplers on pages K-2 through K-6. Vektek, February 2017 800-992-0236 www.vektek.com

Quick Connect with Trigger Mechanism Faster connects/disconnects with Pistol-Grip Trigger Mechanism, Female Connect, and 90 Elbow sold in one convenient package. Ergonomic design reduces operator fatigue. Easily connect/disconnect to hard-to-reach and tall fixtures. Quick Connect with Trigger 56-0009-01 Shutoff Type Accumulator For use with the following Pallet decouplers or other devices using Quick Disconnect coupler Part 30-7727-66 56-0001-01 Manual 1500 psi, Vert. 3.2 cu. in. 56-0001-02 Manual 750 psi, Vert. 3.6 cu. in. 56-0001-03 Manual 1500 psi, Vert. 1.0 cu. in. 56-0002-01 Manual 1500 psi, Horiz. 3.2 cu. in. 56-0002-02 Manual 750 psi, Horiz. 3.6 cu. in. 56-0002-03 Manual 1500 psi, Horiz. 1.0 cu. in. 56-0006-06 Auto 1500 psi, Vert. 3.2 cu. in. 56-0006-07 Auto 750 psi, Vert. 3.6 cu. in. Manual Unload Valves-Tombstone Manual Dump Valves are compact packages that include a manual shutoff valve, check valve, filter screen, auxiliary gauge port and manifold mounting ports. Available with optional manual pressure bleed port. These valves provide separate control of a tombstone face or pallet circuit when integrated into the complete Tombstone Top Plate system shown in the schematic. Manual Unload Valves 70-1017-00 70-1017-03 Description Manual Unload Valve (face mounted) Manual Unload Valve with bleed port Manual Unload Valve, Quick Connect with Trigger Mechanism K-13 L For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 μ in. R a surface finish. www.vektek.com 800-992-0236 Vektek, February 2017

Thread-In Coupling Specifications Thread-In Coupling Elements Coupling elements are made to give you a leak free connection whether pressurized or depressurized. Two flow rates are allowed with your choice of two nominal diameter sizes. The compact design allows couplings to be recessed into the fixture plate. Stainless steel construction provides long service life with replaceable face seals. Axial face seal between coupling mechanism and coupling nipple. Both elements must be positioned and guided within specified tolerances before contact with sealing surfaces. Coupling force at operating pressure ranges from 0-800 and 0-1800 pounds depending on model. Stainless steel construction. Replaceable face seal. Spanner and replacement seal installation tools available. K-14 End Type Coupling Type 56-1013-00 Pressurized Mech. 56-1023-00 Depressurized 56-1015-00 Pressurized Mech. 56-1025-00 Depressurized 56-1113-00 Pressurized Nipple 56-1123-00 Depressurized 56-1115-00 Pressurized Nipple 56-1125-00 Depressurized Max Max. Nom. Ø Thread Flow Operating Rate Pressure (cu.in./min.) 3 5 3 5 M20 x 1.5 M24 x 1.5 M20 x 1.5 M24 x 1.5 NOTE: Clean face of coupling elements with compressed air prior to connecting coupling to protect from contamination intrusion. Both elements must be guided about 1/16 to 1/8 inch before contact of sealing surfaces with radial positioning tolerances. Stroke (in) Min Coupling Force at 0 PSI Axial Position Tolerance Radial Position Tolerance Permit Angle Tolerance 5000 psi 490 0.18 21 lbs. +0.02 ± 0.012 ± 1 7250 psi 730 0.18 22 lbs. +0.02 ± 0.012 ± 1 5000 psi 490 0.18 21 lbs. +0.02 ± 0.012 ± 1 7250 psi 730 0.18 22 lbs. +0.02 ± 0.012 ± 1 Tools 56-1013-00 56-1023-00 56-1015-00 56-1025-00 56-1113-00 56-1123-00 56-1115-00 56-1125-00 Spanner Tool AT-5613-00 AT-5615-00 AT-5613-00 AT-5615-00 Seal Tool AT-5603-00 AT-5605-00 N/A N/A Vektek, February 2017 800-992-0236 www.vektek.com

N MAX. *ALTERNATIVE M MIN. C 63 D G K T Thread-in Coupling Cavity R S PLCS B.0004 R.02 L H A B -.001 -.002 A P Q MAX. E F MECHANISMS CAVITY 0.01 X 45 R.02.08 60 R.02 COUPLING MECHANISMS P End Type Nom. Torque Dia. (lb*ft) A B C D E F G H K L M N P Q R S T 56-1013-00 56-1023-00 56-1015-00 56-1025-00 Mech. 3 11 M20 x 1.5.7090.850.402 N/A 1.228 1.149 N/A.512.445 1.102.197.610.276.102 2.846 Mech. 5 15 M24 x 1.5.8666.850.402.945 1.228 1.142.476.492.445 1.102.197.728.276.110 4.846 P L G K ROUNDED EDGE *ALTERNATIVE M MIN. N P A H B -.001 -.002.08.08 A B.0004 R.02 63 N R S PLCS COUPLING NIPPLES * Only one passage is required, choose option best fit for your application. 60 20 R.02 R.02 D C NIPPLE CAVITY ILS561001 REV B K-15 End Type Nom. Dia. Torque (lb*ft) A B C D G H K L M N P R S 56-1113-00 56-1123-00 56-1115-00 56-1125-00 Nipple 3 11 M20 x 1.5.6304.906.339 1.020.386.512.177.748.197.610.102 2 Nipple 5 15 M24 x 1.5.7878.984.343 1.063.531.551.177.748.197.728.110 4 *Coupling Force Equations: ND3: F (lb) =.1457 * P (psi) ND5: F (lb) =.2387 * P (psi) - Minimum required coupling force between nipple and mechanism resulting from hydraulic operating pressure. - Must be externally countered by some mechanical means. www.vektek.com 800-992-0236 Vektek, March 2018

Wireless Pallet Pressure Monitor Ensures Positive-Pressure Monitoring K-16 Install pressure switches. Find a place on the fixture for your transmitter. Find a place on your machine for your receiver. Wire your control box. No more tool crashes. IT'S THAT SIMPLE! The Guardian gives you full time, In Cycle, hydraulic pressure monitoring configured for your machine tool fixtures. Equipped with an IP 67 sealed pressure switch, sealed Fixture Transmitter, and M12 connectors; Guardian ensures positive-pressure monitoring even in the harshest environments. Best of all, you will enjoy easy pressure monitoring and machine tool notification with no interference issues. The Simple Guardian installs with four wires (Two power wires and a pair of M-code wires). It is a quick and clean installation needing no modifications to the machine tool control. Leave the M-Code check instructions out of your part program for non-monitored fixtures. The Base Guardian system requires six wires and continuously monitors only the pallet in the machining envelope. The pallet being loaded is ignored during the unload/reload process until it enters the machine. Once inside the machine enclosure, Guardian's "focused field" monitors the pallet. Accomplish immediate full-time machine communication by wiring directly into a feed-hold or e-stop control. Guardian notifies your machine immediately of any critical pressure loss. - Fixture Transmitters require no batteries, EVER! - Simplified connection via standard connectors and cables. - Dedicated in-cycle monitoring or machine code polling of fixture status. - Will not affect other plant wireless systems. - Master Control Unit power requirements; 10-36 VDC from Machining Center. - Fully Sealed Fixture Transmitters. Master Control Unit 33-0110-14 Simple 33-0110-24 Base Machine Tool Receiver 33-0111-02 Fixture Transmitter 33-0111-03 Vektek, March 2018 800-992-0236 www.vektek.com

Wireless Pallet Pressure Monitor Accessories Convenience Package Guardian Accessories Cables Description End 1 Connection End 2 Connection Length (ft.) 27-6424-04 Cable, M12 8 Pin* Male Straight Open End 32.8 27-9422-01 Cable, M12 5 Pin Master Control Unit to Machine Tool Male Straight Female 32.8 Receiver Communication Cable** Straight 27-7422-03 16.4 27-7424-01 Extension Cable, M8 3 Pin Pressure Switch to Fixture Transmitter Pressure Switches Male Straight Female Straight 70-7500-78 750-5000 PSI Pressure Switch with 19.7 IN Cable (Shown) 70-7500-74 750-5000 PSI Pressure Switch with M8 Male Connection Only*** * Included with Master control Units 33-0110-14, 33-0110-24 and 33-0110-34. Can be purchased separately for replacement or additional hook up. ** 27-9422-01 is included with 33-0110-14. Cables can be purchased separately for extension or replacement. *** 70-7500-74 requires User Provided 3 Pin M8 Cable. 1.6 K-17 L The Simple and Base Guardian Systems 2 Fixture Transmitter Units 2 Pressure Switches and cables 1 Machine Tool Receiver Master Control All necessary wiring Guardian Convenience Packages Type Description 33-0111-10 Simple Guardian Simple, Monitors only the fixture inside the machining enclosure on demand. 33-0111-20 Base Guardian Base, Monitors only the fixture inside the machining enclosure. www.vektek.com 800-992-0236 Vektek, March 2018