Test Report For: EMECO INDUSTRIES INC Bar Stool

Similar documents
APPLICANT: EMECO DATE: Mar 10, ELM AVE HANOVER, PA, USA

Test Report No.: SDHL FT Date: May 15, 2017 Page 1 of 15

Test Report No.: AJHL FT Date: JUN.02, 2016 Page 1 of 5

Report Number: G CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334

CX5000 CAT 5e UTP System

CX6150 CAT 6 Enhanced UTP System

EESTOR INC. TEST REPORT

CS6700 CAT 6A SHIELDED SYSTEM

CX6850 CAT 6A PREMIUM+ UTP SYSTEM

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

TEST REPORT INTERTEK TESTING SERVICES NA, INC Arlingate Lane Columbus, OH, 43228

Test Report Number: G CRT-039f

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units.

Certified Automotive Parts Association. Vehicle Test Fit Report. Report Number: HN-04060BBQ/COM VTF CAR Refit/ Tong Yang Industry Co.

Test Report No.: SDHL FT Date: Jun.15, 2017 Page 1 of 5

Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

No , Vers.1

The Scala Ladder System Leaning Ladders - Sliding Ladders - Hook-on Ladders 7.1

Report issued by: AUTHORISED FOR ISSUE:. Caroline Blenkhorn Section Head Appliances Department

ANSI/BIFMA X Desk/Table Products - Tests. American National Standard for Office and Institutional Furnishings

T~$t P~Cijpt1oll ', je~t# ' ~n~:2{211rtadje.sampje. PREPARED FOR: Comfor Tek Seating Street North Lethbridge, AB

N , Vers. 0

General-Purpose Office Chairs - Tests

Sliding Door Systems 8.1

AWRF Associated Wire Rope Fabricators

Type: Office work chair Lab.no.: Depth: 650 mm Width: 710 mm Height: 1345 mm Weight: 18,8 kg. EN :2009 and EN :2009.

NovitaTech Engineering

Test Report No.: AJD Date: NOV.05, 2013 Page: 1 of 5

PRODUCT EVALUATION REPORT

FEDERAL STANDARD PERFORMANCE TEST METHOD FOR INTENSIVE USE CHAIRS

Test Report No: EEC18/01 dated August 02, 2018

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

ALFI by JASPER MORRISON

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 3480 Windquest Drive Holland, MI Dan Kolean Phone: MECHANICAL

Seth Setzer Submit Samples to: Phone: Ext.

Code Compliance Research Report CCRR-0258

R E P O R T N U M B E R

Standard Diesel & FCC Additive Technical Analysis on Lubricity

Contact person Date Reference Page Hans Eriksson F000838G 1 (4) Wood Technology

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By:

SPC Series. Digital Scale. Operation Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. UL 2528 Cathy Ln Jasper, IN Brian Truelove Phone: MECHANICAL

Type: Office work chair Lab.no.: A. EN :2009 Office furniture - Office work chair - Part 2: Safety requirements.

Table Tennis Table. Assembly Instructions Model CONTACT INFO. Hours

2 a5;- Ar.7(? ffut)"lr- To: Cc: Sent: Friday, December 20,2013 2:09 PM. From: Crccarelli, Kathryn com] ''il

ALFI by JASPER MORRISON

FOLD N STORE. Table Tennis Table. Assembly Instructions Model , DS, DS CONTACT INFO Hours.

Contact person Date Reference Page Michael Lindblad F000833F 1 (1) Sustainable Built Environment

TERMS AND CONDITIONS

January 18, 2002 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

January 20, 2004 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax SAMPLE N

SFI SPECIFICATION 49.2 EFFECTIVE: MARCH 22, 2011 *

AXD 530 MicroManometer

Sede: Via Antica, 24/ S. Giovanni al Nat. UD Tel r.a. Fax

FOLD N STORE. Table Tennis Table. Assembly Instructions Model DS, DS CONTACT INFO Hours.

Municipality Generator Interconnection Application Single Meter Application Part I

Contact person Date Reference Page Michael Lindblad F013838C 1 (1) Sustainable Built Environment

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

Rear Weight Kit 19A , OEM-19A-218 & M060

Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger March 16, 2016 (Q022516U1R2) Testing Location

S T A N D A R D. ASAE S FEB04 Front and Rear Power Take-Off for Agricultural Tractors

INDUSTRIAL HAUL AGREEMENT

Note: it is a criminal offence to give false information in this application.

TEST REPORT N

R-Solutions Spike Hole Plugging Compound Static and Dynamic Load Tests

Contact person Date Reference Page Ulf Lemke F015337C 1 (4) Wood Technology

Subject - Revisions to PG&E Forms Entitled General Terms and Conditions (Form ) and Declarations (Form ).

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

SFI SPECIFICATION 27.1 EFFECTIVE: OCTOBER 11, 2006 *

SFI SPECIFICATION 32.1 EFFECTIVE: MARCH 24, 2009 *

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

OWNER S MANUAL. 2 Axle

CASING SPACERS DESIGNED FOR WATER, SEWER, OIL & GAS

September 9, Ms. Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, N.E., Room 1A Washington, DC 20426

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Rear Weight Kit M060

Report No 2370/ This Report consists of 40 pages. Authority & date Request by Client dated 25 November 2010

(Text with EEA relevance)

SFI SPECIFICATION 39.2 EFFECTIVE: August 25, 2017 *

Technical Services Report

SFI SPECIFICATION 6.1 EFFECTIVE: FEBRUARY 26, 2014 *

Installation Precautions. Use Precautions. Specifications

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California

WPERC Irrigation Engine Rebate Program Rules

VOUCHER INCENTIVE PROGRAM Application Package

EDSGN 100. Folding Shopping Cart

REPORT NO INSPECTION, TEST AND EVALUATION OF. Interlock Kits SUBMITTED TO MASTER ELECTRICAL SERVICES 3107 LANVALE AVENUE RICHMOND, VA 23230

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

As Introduced. 132nd General Assembly Regular Session S. B. No

OPERATOR S MANUAL MODEL RS-2

November 8, 2004 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

PRE-EMPLOYMENT URINALYSIS NOTIFICATION

SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels

5 Year / 160,000 km (100,000 mi) ** 1 Year / 30,000 km (19,000 mi) 3 Year / 100,000 km (62,000 mi)

Transcription:

4700 Broadmoor SE, Suite 200 Kentwood, MI 49512 Telephone: 616-- 656-- 7401 Facsimile: 616-- 656-- 2022 www.intertek-- etlsemko.com EMECO INDUSTRIES INC P.O. No. N / A Page 1 of 18 Test Report For: EMECO INDUSTRIES INC ANSI/BIFMA X5.1-2017 GENERAL-PURPOSE OFFICE CHAIRS TESTS 20-06 Bar Stool Lynwood Pearson Project Manager James Jantz Reviewer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

P.O. No. N / A Page 2 of 18 Nicole Runde Emeco Industries Inc 805 W Elm Ave Hanover, PA 17331-4706 USA Phone: (717) 637-5951 E-mail: nicole@emeco.net DATE RECEIVED: March 7, 2017 DATES TESTED: March 8 March 16, 2017 DESCRIPTION OF SAMPLES: Part Description: Condition of Test Sample: 20-06 Bar Stool New WORK REQUESTED/APPLICABLE DOCUMENTS: To test the submitted sample per ANSI/BIFMA X5.1 2017 General Purpose Office Chairs Test Standard for the following test program: Test No. Test Description: 7 Drop Test Dynamic 10 Seating Durability Tests Cyclic 11 Stability Tests 17 Leg strength Test Front and Side Application 18 Footrest Static Load Test Vertical 19 Footrest Durability Test Vertical Cyclic CONCLUSION: Test Results Notation ANSI/BIFMA 5.1 2017 #7 Drop Test Dynamic Compliant No loss of serviceability. ANSI/BIFMA 5.1 2017 #10 Seating Durability Tests Cyclic Compliant No loss of serviceability. ANSI/BIFMA 5.1 2017 #11 Stability Tests Compliant No loss of serviceability. ANSI/BIFMA 5.1 2017 #17 Leg strength Test Front and Side Compliant No loss of serviceability. Application ANSI/BIFMA 5.1 2017 #18 Footrest Static Load Test Vertical Compliant No loss of serviceability. ANSI/BIFMA 5.1 2017 #19 Footrest Durability Test Vertical Cyclic Compliant No loss of serviceability.

P.O. No. N / A Page 3 of 18 TEST EQUIPMENT: Asset # Description Last Cal Next Due 138012 Scale/0-1,000# 10/18/2016 10/18/2017 138039.10 WEIGHT BAG VBU VBU 138039.2 WEIGHT BAG VBU VBU 138042 SEATING IMPACT / 2 STATION VBU VBU 138112 Graduated Rule 36" 10/11/2013 10/11/2018 138211 BED EDGE TESTER VBU VBU 138272 Load Cell 0-10000# 10/19/2016 10/19/2017 138279 FORCE GAUGE 3/3/2017 3/3/2018 138400 SCIENTIFIC STOPWATCH 4/26/2016 4/26/2017 138916.2 TIMING BOX VBU VBU

P.O. No. N / A Page 4 of 18 7. DROP TEST DYNAMIC: Date Tested: March 16, 2017 Condition of Test Sample: New Test Procedure: Test Method: ANSI/BIFMA X5.1-2017; Test No. 7 Functional Load: 225 lbs. Proof Load: 300 lbs. Drop Height: 6 Number of Samples Tested: One (1) Acceptance Criteria: Functional Load: Proof Load: There shall be no loss of serviceability. There shall be no sudden and major change in the structural integrity of the product. Loss of serviceability is acceptable. Results: Sample ID Drop Weight Results Functional Load 225 lbs. Pass 1 Proof Load 300 lbs. Pass The submitted sample met the acceptance criteria of the test described above. Refer to the following page for photograph.

P.O. No. N / A Page 5 of 18 Drop Test Dynamic

P.O. No. N / A Page 6 of 18 10. SEATING DURABILITY TESTS CYCLIC Date Tested: March 10 March 16, 2017 Condition of Test Sample: New Test Procedure: Test Method: ANSI/BIFMA X5.1-2017; Test No. 10 Section 10.3 Impact Test Bag Diameter: 16 Bag Weight: 125 lbs. Number Cycles: 100,000 Height of Drop: 1.4 Cycles per Minute: 10 to 30 Section 10.4 Front Corner Load-Ease Test Cyclic Off-center Bag Diameter: 8 Bag Weight: 200 lbs. Number of Cycles Required: 20,000 to each Front Corner Cycles per Minute: 10 to 30 Number of Samples Tested: One (1) Acceptance Criteria: There shall be no loss of serviceability to the chair after completion of both the Impact and Load Ease Tests. If applicable, the chair base (center structure) shall not touch the test platform as a result of the impact loads. Results: Section 10.3 Section 10.4 Sample No. Number of Cycles Description of Results 1 100,000 Pass Location of Force Number of Cycles Description of Results Left Front Corner 20,000 Pass Right Front Corner 20,000 Pass The submitted sample met the acceptance criteria of the test described above. Refer to the following pages for photographs.

P.O. No. N / A Page 7 of 18 Impact Test

P.O. No. N / A Page 8 of 18 Load Ease Test

P.O. No. N / A Page 9 of 18 11. STABILITY TESTS (Front and Rear): Date Tested: March 16, 2017 Condition of Test Sample: New Test Procedure: Test Method: ANSI/BIFMA X5.1-2017; Test No. 11 All of the chair's adjustable features shall be set for the most unstable conditions. Chair Type: Section 11.3 Weight in Seat Section 11.4 Alternative: Vertical Load: Horizontal Force: III Rear Stability Type I: 286 lbs. (13 disks) Type II: 286 lbs. (13 disks) Type III: 132 lbs. (6 disks) Front Stability N / A 135 lbs. 4.5 lbs. Number of Samples Tested: One (1) Acceptance Criteria: Rear Stability: Front Stability: Results: The force to tip shall not be less than: Type I: Chair must not tip over Type II: Chair must not tip over Type III: [F = 1.1 (47 H) pounds force.]. H is the seat height in inches. For chairs with seat height equal to or greater than 710 mm (28.0 in.), a fixed force of 93 N (20.9 lbf.) shall be applied. : The chair shall not tip over as the result of the force application of 4.5 lbf. Sample ID Seat Height Front Stability Rear Stability Results 1 30.25 11.8 lbf. to tip N / A Pass The submitted sample met the acceptance criteria of the test described above. Refer to the following page for photograph.

P.O. No. N / A Page 10 of 18 Front Stability

P.O. No. N / A Page 11 of 18 17. LEG STRENGTH TEST FRONT AND SIDE APPLICATION: Date Tested: March 16, 2017 Condition of Test Sample: New Test Procedure: Test Method: ANSI/BIFMA X5.1 2017; Test No. 17 Section 17.3 Functional Load: Proof Load: Section 17.4 Functional Load: Proof Load: Front to Rear Application: 75 lbf. (Load Each Leg) 113 lbf. (Load Each Leg) Side to Side Application: 75 lbf. (Load Each Leg) 113 lbf. (Load Each Leg) Number of Samples Tested: One (1) Acceptance Criteria: Functional Load: Proof Load: Results: No structural breakage or loss of serviceability, including stacking if applicable. No sudden and major change in the structural integrity of the product. Loss of serviceability is acceptable. Sample ID 1 Load Application Functional Results Proof Results Side to Side (Rear Side) Side to Side (Front Side) Front to Rear (Left Side) Front to Rear (Right Side) 75 lbf. Pass 113 lbf Pass 75 lbf. Pass 113 lbf Pass 75 lbf. Pass 113 lbf. Pass 75 lbf. Pass 113 lbf. Pass The submitted sample met the acceptance criteria of the test described above. Refer to the following page for photograph.

P.O. No. N / A Page 12 of 18 Leg Strength Test Front Application

P.O. No. N / A Page 13 of 18 Leg Strength Test Side Application

P.O. No. N / A Page 14 of 18 18. FOOTREST STATIC LOAD TEST VERTICAL Date Tested: March 10, 2017 Condition of Test Sample: New Test Procedure: Test Method: ANSI/BIFMA X5.1-2017; Test No. 18 Functional Load: a) Apply a force F1 of 100 lbf. uniformly along a 4 in. distance along the footrest but not greater than 2 in. from the outside edge at the apparent weakest point of the structure for one (1) minute in the vertical downward direction. If the footrest adjusts in height relative to the seat and allows for a force application 180 degrees (on the opposite side of the chair) from the primary force application, maintain force F1 and apply an additional force F2 of 100 lbf. to the footrest at the opposing position for an additional one (1) minute. The F2 force shall also be applied uniformly along a 4 in. distance along the footrest but not greater than 2 in. from the outside edge. b) If applicable, remove force F2. c) Increase the force F1 to 200 lbf. for one (1) minute. Proof Load: Apply a force of 300 lbf. uniformly along a 4 in. distance along the footrest but not greater than 2 in. from the outside edge at the apparent weakest point of the structure for one (1) minute in the vertical downward direction. Number of Samples Tested: One (1) Acceptance Criteria: The load applied once shall cause no sudden and major change in the structural integrity of the unit. Loss of serviceability is acceptable. Results: Sample ID Load (lbf.) Results Functional Load 200 lbf. Pass 1 Proof Load 300 lbf. Pass The submitted sample met the acceptance criteria of the test described above. Refer to the following page for photograph.

P.O. No. N / A Page 15 of 18 Footrest Static Load Test Vertical

P.O. No. N / A Page 16 of 18 19. FOOTREST DURABILITY TEST VERTICAL CYCLIC Date Tested: March 8 March 10, 2017 Condition of Test Sample: New Test Procedure: Test Method: ANSI/BIFMA X5.1-2017; Test No. 19 Load To Footrest: 200 lbs. Direction of Force: Vertically Downward Number of Cycles Required: 50,000 Cycles per Minute: 10 to 30 Number of Samples Tested: One (1) Acceptance Criteria: There shall be no loss of serviceability. Adjustable footrests that move more than 25 mm (1 in.) in the first 500 cycles shall be considered to have lost their serviceability. Results: Sample ID Number of Cycles Description of Results 1 50,000 Pass The submitted sample met the acceptance criteria of the test described above. Refer to the following page for photograph.

P.O. No. N / A Page 17 of 18 Footrest Durability Test Vertical Cyclic

P.O. No. N / A Page 18 of 18 Revisions Made To Test Report Date Revision Description Revised by Revised by 16-Mar-2017 Initial release. Lynwood Pearson