F84C - Excelon Plus Modular System Oil removal filter

Similar documents
F84G - Excelon Plus Modular System General purpose filter

F84V - Excelon Plus Modular System Oil vapour removal filters

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

L84M, L84C - Excelon Plus Modular System Micro- and oilfog lubricator

T84T - Excelon Plus Modular System 3/2 shut-off valve

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

L84M, L84C - Excelon Plus Modular System Micro-Fog and Oil-Fog Lubricators

T84T - Excelon Plus Modular System 3/2 shut-off valve

F64C, F64H - Olympian Plus Plug-In System Puraire high efficiency coalescing filter

BL68 - Olympian Plus plug-in system Filter/regulators and lubricators

Weight (kg) Model L92C- P-ETN. N/en

Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en

Drain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

P64F - Olympian Plus plug-in system Soft start/dump valves

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.

Weight (kg) Dimension No. G1/4 Exhausting None 0,2 1 T F2BG *1) Interface Exhausting None 0,4 3 T10-N10-D2BN

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

with interchangeable cartridges: 1/8, 1/4 and 3/8 threaded or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm

, /2 Soft start ( soft clutch ) valve

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

P72F P74F P74F-AD P7 F- - 1/4" (72) 2 3/8" 3 1/2" (74) 4 3/4" (74) 6. ISO G parallel

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

F64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6

82 series Brass compression fittings

83 series Brass compression fittings

FLEXIBILITY, VALUE AND EASE OF USE NO TOOLS REQUIRED

SBM TECHNOLOGY Cooling / Air Recovery Valve

AUTO STAR with central connector M12x1

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

25000, 4/2 Direct solenoid actuated poppet valves

24010, 3/2 Direct solenoid actuated poppet valve

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

LRM/55401/M, Roundline cylinder Magnetic piston, double acting

60 series, 2/2 or 3/2 Ball valve

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters

SBM TECHNOLOGY PET Blow Valve Block

Filters, Gauges, Regulators

Orders. Combination shut off valve, filter/regulator and lubricator. Models. BL92 ø 8 mm, G1/4. For further information

NFPA Double acting imperial cylinders

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

LPRA/182000/M, ISO cylinder Magnetic piston, double acting

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat

LRA/8000/M/EX, LRA/8000/EX, ISO cylinder Magnetic & Non-magnetic piston, double acting

Inside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10.

Operating pressure (bar) kv factor (m 3 /h) *3)

60 SCFM Model # A B C D 3C-060-M04-P, Manual Drain C-060-M04-F, Float Drain C-060-M04-Fi, Float Drain w/indicator

Air Preparation Products

Parker Global Air Preparation System

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS

AIR PREPARATION PRODUCTS. Table of Contents

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

5.22 A IR PREPARATION FILTERS: HIGH EFFICIENCY H IGH FLOW AIR FILTER SERIES AF AF (1 1 2) AF (2) AF (1 1 2) AF (2) S TOCKED

PRA/842000/M, PRA/ Clean Line cylinder Magnetic or non-magnetic piston, double acting

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

Parker Global Air Preparation System. A complete air preparation system

120 SCFM Eliminex Port Sizes 1/2", 3/4", 1" Maximum Temp. & Pressure* PSI Polycarbonate 175 F, 200 PSIG Polycarb. 125 F, 150 PSIG Model

VM15 series, 2 x 3/2, 5/2 or 5/3 Valve islands

Nugget 40, V08 series

N/** поставка оборудования для подготовки воздуха

A44000, LINTRA-LITE Rodless Cylinders Non-magnetic and Magnetic Piston, double acting

Product Data Sheet Filter Elements ERUF.. (for ultrafilter filter housings)

Our policy is one of continued research and development. We therefore reserve the right

Modular line 042 1/4. Regulator. Regulator

83 series Brass compression fittings Ø 1/ nominal pipe size, NPT thread

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

VR61, 3/2, 2 x 3/2, 5/2 or 5/3 Solenoid and pilot actuated spool valves

Filters, regulators, and lubricators

Air Preparation Products 652 Series Filter Regulator (FR) for Process Industry Applications

Page General Purpose Filter Replacement Filter Elements Bowl Assemblies Accessories & Optional Extras

F1000/F3000/F4000/F8000 Series

Compressed Air Cleaning Filter Series

ISO Cylinders Compact Cylinders TC08 Series Plastic Finger Tight Fittings

M/44000/M. LINTRA Rodless cylinders Magnetic piston Double acting Ø 25 to 40 mm

Compressed Air Cleaning Filter Series

Valve Islands, V22 Series Sub-base Mounted 2 x 3/2, 5/2 and 5/3 Valves Solenoid Actuated with Wireway

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

C D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right

Norgren Filters, Regulators and Lubricators. dixonvalve.com Customer Service:

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

FILTERS, REGULATORS & LUBRICATORS

PURESTREAM -FRL PURESTREAM - FRL. Installation / Operating / Maintenance Instructions Filter Series F1. Specifications.

Oil Mist Separator Unit LGA 1200 FU/FUW

Our policy is one of continued research and development. We therefore reserve the right to amend,

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an

AIR PREPARATION PRODUCTS

M/1000, Heavy Duty Cylinders Double Acting

Filters MS-LFM/LFX, MS series, NPT

-Q- Temperature range C. -L- Operating pressure bar. Vacuum filters ESF Technical data. Function

97100 NAMUR. Technical data

FRL/AirCare Air Controls & Accessories

Transcription:

> Port size: 3/8... 3/4 (ISO G/PTF) > Light weight Polycarbonate bowl > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > High efficiency oil and particle removal > Double safety lock bowl > Metal bowl with prismatic liquid level indicator lens > Service indicator standard > Air purity class in accordance with ISO 8573-1: Remaining oil aerosol to class 1* *Tested in accordance with the methods laid out in ISO 12500-1 using an inlet oil aerosol concentration of 4mg/m³ Technical features Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 10 bar (145 psi) Metal bowl: 20 bar (290 psi) Remaining oil content: 0,01 mg/m 3 at +21 C (+69 F) Particle removal: To 0,01 μm Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Flow: Maximum flow to maintain stated oil removal performance at challenge rate of 4 mg/m 3 F84C: 25 dm 3 /s, at port size: 1/2 Operating pressure: 6,3 bar (91 psi) Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: 0,2 bar (2.9 psi) Minimum air flow required to close drain: 1 dm 3 /s (2 scfm) Ambient/Media temperature: Polycarbonate bowl: -10... +60ºC (+14... +140ºF) Metal bowl: -20... +65ºC (-4... +149 F) Air supply must be dry enough to avoid ice formation at temperatures below +2 C (+35 F). Note: Install an F84G filter with a 5 μm filter element upstream of the F84C filter for maximum service life. Materials: Body: Die cast aluminium Body covers: ABS Bowl: Transparent PC with PP guard or die cast aluminium Liquid level indicator lens (metal bowl): PA Filter element: Synthetic fibre & PE foam Bowl o - ring: Chloroprene Elastomers: NBR Technical data F84C - standard models Symbol Port size Drain Bowl Weight Model (kg) G3/8 Auto Guarded polycarbonate 0,38 F84C-3GD-AP0 G1/2 Auto Guarded polycarbonate 0,38 F84C-4GD-AP0 G3/4 Auto Guarded polycarbonate 0,38 F84C-6GD-AP0 G3/8 Auto Metal with level indicator 0,52 F84C-3GD-AD0 G1/2 Auto Metal with level indicator 0,52 F84C-4GD-AD0 G3/4 Auto Metal with level indicator 0,52 F84C-6GD-AD0 G3/8 Manual Guarded polycarbonate 0,38 F84C-3GD-QP0 G1/2 Manual Guarded polycarbonate 0,38 F84C-4GD-QP0 G3/4 Manual Guarded polycarbonate 0,38 F84C-6GD-QP0 G3/8 Manual Metal with level indicator 0,52 F84C-3GD-QD0 G1/2 Manual Metal with level indicator 0,52 F84C-4GD-QD0 G3/4 Manual Metal with level indicator 0,52 F84C-6GD-QD0 without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd en 8.200.155.01

Option selector Port size Substitute 3/8 3 1/2 4 3/4 6 Thread form Substitute PTF A ISO G parallel (standard) G F84C- D- 0 Bowl Metal with liquid indicator Transparent with guard (standard) Drain Manual (standard) Auto drain (standard) Substitute D P Substitute Q A Typical performance characteristics Inlet pressure Maximum flow (bar) (dm3/s) *1) 2,50 12 4,00 17 6,30 25 8,00 30 10,00 35 *1) Maximum flow to maintain stated oil removal performance Flow characteristics F84C Port size: 1/2, wet element Pressure drop Δp (bar) Inlet pressure Inlet pressure 0,45 2.5 0,40 0,35 0,30 0,25 4.0 6.0 0,20 0,15 6.3 8.0 0,10 10 0,05 0,0 0 5 10 15 20 25 30 Air flow (dm 3 /s) en 8.200.155.02 without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd

Accessories Wall mounting bracket Quikclamp Quikclamp with bracket assembled Pressure sensing block 1/4 PTF Pressure sensing block G1/4 Page 6 Page 6 Page 6 Page 6 Page 6 840024-50KIT 840014-51KIT 840014-52KIT 840016-50KIT 840016-51KIT Full flow porting block 3/4 PTF Full flow porting block G3/4 Pressure switch interface block (18D pressure switch) Pneumatic pressure switch 18D (0,5... 8 bar) *1) Digital pressure switch 51D (-1... 10 bar) *2) Page 6 Page 6 Page 7 Page 7 Page 7 840028-50KIT 840028-53KIT 0337717000000000 0881300 0860810 *1) Flanged version. For other pressure ranges, please see data sheet 5.11.001 *2) For other pressure ranges, please see data sheet 5.11.385 3/8 PTF 1/2 PTF 3/4 PTF G3/8 G1/2 G3/4 Page 7 Page 7 Page 7 Page 7 Page 7 840015-02KIT 840015-03KIT 840015-04KIT 840015-10KIT 840015-11KIT 840015-12KIT without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd en 8.200.155.03

Maintenance/Service Coalescing filter element Auto drain kit with metal Nut - Imperial Auto drain kit with metal Nut - Metric 840044-50KIT 6000-61KIT 6000-60KIT Spare parts (Guarded Poly bowl with auto drain 6 mm PIF) (Guarded Poly bowl with manual drain) (Metal with S/Glass & auto drain, 6 mm PIF) (Metal with S/Glass & manual drain) 840025-51KIT 840025-50KIT 840003-51KIT 840003-50KIT (Guarded Poly bowl with auto drain, 1/4 PIF) (Metal with S/Glass & auto drain, 1/4 PIF) 840025-53KIT 840003-56KIT en 8.200.155.04 without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd

Dimensions Dimensions in mm Projection/Third angle 73 36 36 70 4 1 181 233 230 52 3 2 # 25 Automatic Drain 1/4 Turn Manual Drain # Minimum clearance for bowl removal 1 Main ports 3/8, 1/2 or 3/4 (ISO G/PTF) 2 Transparent bowl with guard 3 Metal bowl with liquid level indicator lens 3 Service indicator without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd en 8.200.155.05

46 57 51 29 36 47 57 5 8 49 119 54.3 56 47 54 F84C - Excelon Plus Modular System Accessories Dimensions in mm Projection/Third angle Quikclamp with wall bracket Quikclamp 76 51 14 7 60 11.5 4 5 Mounting bracket 8.9 15 58 71 15 4 18 66 31 Pressure sensing block Full flow porting block 80 51 68 45 21 33 en 8.200.155.06 without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd

40 40 38.5 30 5 45 18 A/C F84C - Excelon Plus Modular System Porting block for 18D pressure switch 18D Pressure switch 27.5 Dimensions in mm Projection/Third angle 32 44 G1/2 40 35 30 72 18D Porting block and 18D assembled Pipe adaptor 38.5 18 32 44 G1/2 40 57 51D Pressure switch - digital 31 36,5 1 2 ~30 ~300 31 6 5 G1/8 7 1 Switch OUT 1, green LED 2 Switch OUT 2, red LED 3 3 Dustproof protector 4 Connector M12 x 1 5 Inlet port 6 Alternative inlet port G1/8 plugged 7 Thread for mounting screw 4 without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd en 8.200.155.07

Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. en 8.200.155.08 without notice, the specifications given in this document. (2017-9214a) 2015 Norgren Ltd