RVCH-027 Health Safety Controller Information

Similar documents
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Application Engineering

LOADHOG BATTERY CHARGER

GLMV169DBF PLMV169DCG

Application Engineering

NM1250R SERVICE PARTS

EI30MH55GBA EI30MH55GSA EI30MH55GWA EI30MH55GZA

3200NT Timer Service Manual

SERVICE MANUAL (INTERNATIONAL)

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit

FMV156DBF FMV156DCG FMV156DQF FMV156DSF

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Eclipse 2000 Service Parts

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

REPLACEMENT PARTS MANUAL

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual

GCU-10. Automatic Engine Control Unit Operators Manual

Fault Codes. J control

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

GLMB209DBC GLMB209DQC GLMB209DSC PLMB209DCD

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

BUNN CDS-2 ILLUSTRATED PARTS CATALOG

nufacturing Company, L.P San Felipe, Suite 500

Installation, Operation and Maintenance Manual

SECTION 5 PARTS LISTS & EXPLODED VIEWS

OPERATING INSTRUCTIONS AND SERVICE MANUAL COUNTDOWN TIMER. MODEL MP-3905 WITH MP-2002 Control

Solstice Electric Fryers SE Series Service Manual


POWERLINE 2000 Energy Management System TM

Setup and Programming Manual

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

Installation, Operation and Maintenance Manual

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

PARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

Ultrafryer Low Oil Level Model E3RL-14/8 Operation Instructions for Remote U-23 with Auxiliary Controls

nufacturing Company, L.P San Felipe, Suite 500

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

C1448, C1848, C2148 Service Parts

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

MDT5N25 & MTD5N40 SERVICE PARTS

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

Parts Catalog. Mixer SP20. Model:

FM800R SERVICE PARTS

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

Senior Swing Control Box. Table of Contents

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Table of Contents. For latest version, visit:

Electronic Refrigerator Diagnostics

SECTION 3. PARTS INFORMATION INTRODUCTION This section identifies and lists the replaceable parts of the Henny Penny merchandiser.

REPLACEMENT PARTS MANUAL

CN268/328 Bus Air-Conditioning Units. Service Parts Manual

nufacturing Company, L.P San Felipe, Suite 500

SECTION 7. PARTS INFORMATION

NME950 & FME1200 SERVICE PARTS

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

MDT5N25 & MTD5N40 SERVICE PARTS

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

NME650R SERVICE PARTS

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

nufacturing Company, L.P San Felipe, Suite

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

DESCRIPTION PART NUMBER GRP

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

XENON POWER SUPPLY 4000 Watt Gladiator IV

nufacturing Company, L.P San Felipe, Suite 500

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

MULTI-ZONE FOAMED MACHINE MODEL PARTS MANUAL

ELECTRO-MECH SCOREBOARD CO.

FMV156DBB FMV156DCC FMV156DQB FMV156DSB

ERROR RECOVERY ERR R O C D O ES / REC V O E Y R PR C O EDURES E

B-PC20 Power Close Module

Drying Tumblers 120 Pound Capacity Refer to Page 3 for Model Numbers Cover

CHEV P-UP CONTROL PANEL CONVERSION KIT an ISO 9001:2008 Registered Company

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Application Engineering Europe

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

REPAIR PARTS. DP13HM Package Heat Pump Units 3-Phase DP13HM3643AA DP13HM4843AA DP13HM6043AA. This manual is to be used by qualified technicians only.

NM650 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

Parts Catalog SLICING MACHINES

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

ELECTRICAL SYSTEM RP-7

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

SERVICE MANUAL (INTERNATIONAL)

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

XENON POWER SUPPLY Compact Model 220 Volt Equipment Type

The parking brake is an electrically actuated system that operates drum brakes integrated into the rear brake discs. The

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

OPERATING INSTRUCTIONS AND SERVICE MANUAL FOOTBALL SCOREBOARD MODEL MP-3455 WITH MP-3000 CONTROL

Transcription:

Royal Vision Cooler RVCH-07 Health Safety Controller Information R Royal Vendors, Inc. 46 Industrial Boulevard Kearneysville, West Virginia 540-776 USA Telephone + 04 78 7056 Toll Free in North America 800 9 94 Fax + 04 75 406 www.royalvendors.com

Serial numbers 06RA00007 and after Health Safety Controller Operation. When the controller is first powered up, a Health Safety error will be present, the diagnostic LED will be on continuously, and the controller will supply (-) 4VDC to lock the door. This is intended to prevent access to spoiled food or drinks whenever the previous state of the refrigeration is unknown.. To reset the Health Safety error, press the RESET switch. This will clear all errors, supply (+) 4VDC to the solenoid to unlock the door, and initiate a timer.. Upon reset, the controller will enter a grace period. At the end of this grace period, the controller will sample the cabinet temperature to see if the temperature is below 4 F (5 C). The length of this grace period is determined by the state of the door switch at the time the reset button is pressed. a. a. If the door is open at the time of reset, the controller will allow a 60-minute grace period. b. If the door is closed, the controller will allow a 0-minute grace period. c. If at the end of either grace period (0 or 60 minutes) the temperature is not below 4 F (5 C), the controller will trigger a Health Safety error, supply (-) 4VDC to lock the door, and the diagnostic LED will indicate a Health Safety error. 4. The controller constantly monitors the cabinet temperature. After the initial grace period has expired, the controller will assume normal operation and watch for an unexpected rise in temperature. a. If the temperature is observed to rise above 4 F (5 C), the controller will start a 5-minute timer. b. If the temperature remains above 4 F (5 C) for more than 5 minutes, the controller will trigger a Health Safety error and supply (-) 4VDC to lock the door. c. If within this 5-minute period the temperature falls below 4 F (5 C), the 5-minute timer will be reset and no error will occur. 5. The controller constantly monitors the state of the door switch. If the controller determines that the door switch has cycled (i.e., gone from closed to open or open to closed), the controller will begin a grace period. The length of this grace period will depend upon the state of the door after the transition has occurred. a. If the door remains open, the controller will allow a 60-minute grace period. b. If the door remains closed, the controller will allow a 0-minute grace period. c. If the door again cycles during the timeout period, the grace period will be reset and the countdown will be based upon the state of the door switch based on rules (a) or (b) above. d. At the end of the grace period, the cabinet temperature must be at or below 4 F (5 C). If the temperature is above 4 F (5 C), the Health Safety error will be triggered and supply (-) 4VDC to lock the door. If the temperature is below 4 F (5 C), normal operation will resume. Royal Vision Cooler Health Safety Controller Information

6. The controller constantly monitors the AC power through an AC power detector circuit. When AC power is disrupted, the controller will shed all loads (LED, sensors, etc.), immediately supply (-) 4VDC to the solenoid from a capacitor or battery to lock the door, and enter into a low-power state of operation. The controller will remain in this low-power state for 0 minutes or until AC power returns. If AC power returns before the 0-minute timeout period has expired, the controller will sample the temperature upon power-up. a. If the temperature is below 4 F (5 C), the controller will return to normal operation and supply (+) 4VDC to unlock the door. b. If the temperature is above 4 F (5 C), the controller will trigger the Health Safety error and supply (-) 4VDC to lock the door (to ensure the door is still locked). c. If power is not restored within the 0-minute timeout period, the controller will trigger the Health Safety error and enter into stop mode. Serial numbers 06RA00006 and before. When the controller is first powered up, a Health Safety error will be present, the diagnostic LED will be on continuously, and the door solenoid will not be activated. This is intended to prevent access to spoiled food or drinks whenever the previous state of the refrigeration is unknown.. To reset the Health Safety error, press the RESET switch. This will clear all errors, activate the door solenoid, and initiate a timer.. Upon reset, the controller will enter a grace period. At the end of this grace period, the controller will sample the cabinet temperature to see if the temperature is below 4 F (5 C). The length of this grace period is determined by the state of the door switch at the time the reset button is pressed. a. If the door is open at the time of reset, the controller will allow a 60-minute grace period. b. If the door is closed, the controller will allow a 0-minute grace period. c. If at the end of either grace period (0 or 60 minutes) the temperature is not below 4 F (5 C), the controller will trigger a Health Safety error, the door will be locked, and the diagnostic LED will indicate a Health Safety error. 4. The controller constantly monitors the cabinet temperature. After the initial grace period has expired, the controller will assume normal operation and watch for an unexpected rise in temperature. a. If the temperature is observed to rise above 4 F (5 C), the controller will start a 5-minute timer. b. If the temperature remains above 4 F (5 C) for more than 5 minutes, the controller will trigger a Health Safety error. c. If within this 5-minute period the temperature falls below 4 F (5 C), the 5-minute timer will be reset and no error will occur. 5. The controller constantly monitors the state of the door switch. If the controller determines that Royal Vision Cooler Health Safety Controller Information

the door switch has cycled (i.e., gone from closed to open or open to closed), the controller will begin a grace period. The length of this grace period will depend upon the state of the door after the transition has occurred. a. If the door remains open, the controller will allow a 60-minute grace period. b. If the door remains closed, the controller will allow a 0-minute grace period. c. If the door again cycles during the timeout period, the grace period will be reset and the countdown will be based upon the state of the door switch based on rules (a) or (b) above. 6. At the end of the grace period, the cabinet temperature must be at or below 4 F (5 C). If the temperature is above 4 F (5 C), the Health Safety error will be triggered. If the temperature is below 4 F (5 C), normal operation will resume. 7. The controller constantly monitors the AC power through an AC power detector circuit. When AC power is disrupted, the controller will shed all loads (solenoid, LED, sensors, etc.) and enter into a low-power state of operation. 8. The controller will remain in this low-power state for 0 minutes or until AC power returns. If AC power returns before the 0-minute timeout period has expired, the controller will sample the temperature upon power-up. a. If the temperature is below 4 F (5 C), the controller will return to normal operation. b. If the temperature is above 4 F (5 C), the controller will trigger the Health Safety error. c. If power is not restored within the 0-minute timeout period, the controller will trigger the Health Safety error and enter into stop mode. 4 Royal Vision Cooler Health Safety Controller Information

Health Safety Controller Pinouts Serial numbers 06RA00007 and after LED_DSPLY HS_RESET The Health Safety controller is responsible for all proper function of the Health Safety system. The board is located in the bottom right section of the Cooler s cabinet and is protected by a cover. Removing this cover will expose the board, along with all wiring connections to it. CN6 ERROR_SW CN8 TEMP CN7 DOOR CN5 SOLND CN4 4 VAC Health Safety controller (serial numbers 0-- and after). OPERATION REQUIREMENTS: The Health Safety controller requires approximately 4 volts AC from the transformer. This allows the controller to function and to supply power to the components listed below. PINOUTS: The Health Safety Controller has several electrical pinouts, a reset button, and an indicator LED. The following section outlines all the controller s pinouts. The word key refers to the small plastic insert plugged into a position of the wire harness connector. The purpose of the key is to prevent connecting the harnessing backward or upside-down. The keyed position is a blank position within the pinout (no pin) in which a key is inserted. Some pinouts may have several blank positions with a key plugged into one or more of the positions. You can use the key to determine which end of the pinout is Pin. 4 VAC (Position CN4): The harness connecting to this pinout comes from the transformer. It is imperative that the correct harness be connected to this pinout. If this harness is not connected, the Health Safety system will not function and the door will be locked. PIN WIRE COLOR SIGNAL / FUNCTION Red 4 VAC power Green Ground Black 4 VAC power SOLND (Position CN5): This harness connects to the solenoid. The solenoid is used to lock or unlock the door, depending upon the signal the controller receives from the door switch and the temperature sensor. PIN WIRE COLOR SIGNAL / FUNCTION Red 4 VDC power for solenoid Black Ground Royal Vision Cooler Health Safety Controller Information 5

ERROR_SW (Position CN6): This harness connects to the external reset switch, located below the grille along the lower right-hand side. A reset button can also be found on the controller itself, to the left of this pinout. Resetting of the Health Safety system is performed using either of these two buttons. PIN WIRE COLOR SIGNAL / FUNCTION Red Reset signal Black Ground for switch signal DOOR (Position CN7): The harness connecting to this pinout comes from the door switch. From the signal received from this switch, the controller determines the current state of the door (open or closed). PIN WIRE COLOR SIGNAL / FUNCTION Red Door switch signal; when the door is open, the switch is closed. Black Return to ground for switch signal SNSR (Position CN8): This harness connects to the temperature sensor, which is mounted in the refrigeration deck. The controller uses the information received from this sensor to monitor the temperature inside the cabinet. PIN WIRE COLOR SIGNAL / FUNCTION Red 5 VDC White Temperature sensor signal - Key 4 Black Return to ground 6 Royal Vision Cooler Health Safety Controller Information

Serial numbers 06RA00006 and before J 4 VAC J DOOR J DFRST DSPLY J5 RESET J6 SNSR J7 SOLND The Health Safety controller is responsible for all proper function of the Health Safety system. The board is located in the bottom right section of the Cooler s cabinet and is protected by a cover. Removing this cover will expose the board, along with all wiring connections to it. OPERATION REQUIREMENTS: The Health Safety controller requires approximately 4 volts AC from the transformer. This allows the controller to function and to supply power to the components listed below. Health Safety controller (serial numbers 0-- and before). PINOUTS: The Health Safety Controller has several electrical pinouts, a reset button, and an indicator LED. The following section outlines all the controller s pinouts. The word key refers to the small plastic insert plugged into a position of the wire harness connector. The purpose of the key is to prevent connecting the harnessing backward or upside-down. The keyed position is a blank position within the pinout (no pin) in which a key is inserted. Some pinouts may have several blank positions with a key plugged into one or more of the positions. You can use the key to determine which end of the pinout is Pin. 4 VAC (Position J): The harness connecting to this pinout comes from the transformer. It is imperative that the correct harness be connected to this pinout. If this harness is not connected, the Health Safety system will not function and the door will be locked. PIN WIRE COLOR SIGNAL / FUNCTION Red 4 VAC power Green Ground Black 4 VAC power DOOR (Position J): The harness connecting to this pinout comes from the door switch. From the signal received from this switch, the controller determines the current state of the door (open or closed). PIN WIRE COLOR SIGNAL / FUNCTION Red Door switch signal; when the door is open, the switch is closed. Black Return to ground for switch signal Royal Vision Cooler Health Safety Controller Information 7

DFRST (Position J): This pinout is not used. RESET (Position J5): This harness connects to the external reset switch, located below the grille along the lower right-hand side. A reset button can also be found on the controller itself, to the left of this pinout. Resetting of the Health Safety system is performed using either of these two buttons. PIN WIRE COLOR SIGNAL / FUNCTION Red Reset signal Black Ground for switch signal SNSR (Position J6): This harness connects to the temperature sensor, which is mounted in the refrigeration deck. The controller uses the information received from this sensor to monitor the temperature inside the cabinet. PIN WIRE COLOR SIGNAL / FUNCTION Red 5 VDC White Temperature sensor signal - Key 4 Black Return to ground SOLND (Position J7): This harness connects to the solenoid. The solenoid is used to lock or unlock the door, depending upon the signal the controller receives from the door switch and the temperature sensor. If power is lost to the solenoid, the door will be locked. PIN WIRE COLOR SIGNAL / FUNCTION Red 4 VDC power for solenoid Black Ground 8 Royal Vision Cooler Health Safety Controller Information

LED Status Indicator The Health Safety controller has an on-board bi-color LED lamp (at the position marked LED_DSPLY or DSPLY ) that indicates the state of its operations through a series of LED flash sequences. Each flash within a given sequence is separated by a one-second pause. Each flash sequence is terminated by a four-second pause. Multiple error codes are sequenced one after another and are separated by a foursecond pause. For example, the flash sequence below would indicate Message ( The door is closed and everything is good ): ON OFF OFF OFF OFF ON OFF OFF OFF OFF The following would indicate Message 4 ( The controller has a health safety error ): ON OFF ON OFF ON OFF ON OFF OFF OFF OFF Serial numbers 06RA00007 and after Flashes Meaning / Interpretation 0 (LED on continuously) The controller is waiting to be reset. Door is closed and everything is good. (green) Door is open and everything is good. (green) The temperature sensor is working, but the temperature is greater than 4 F (5 C). (green) 4 The controller has a health safety error. (red) 5 The temperature sensor is unplugged or defective. 6 not used 7 not used 8 not used 9 Health safety error caused by the door being open too long. Serial numbers 06RA00006 and before Flashes Meaning / Interpretation 0 (LED on continuously) The controller is waiting to be reset. Door is closed and everything is good. (green) Door is open and everything is good. (green) The temperature sensor is working, but the temperature is greater than 4 F (5 C). (green) 4 The controller has a health safety error. (red) 5 The temperature sensor is unplugged or defective. 6 The door lock solenoid is shorted or drawing too much current. 7 The door lock solenoid open or not drawing enough current. 8 The controller has just been reset. 9 Health safety error caused by the door being open too long. Royal Vision Cooler Health Safety Controller Information 9

Refrigeration Control The recommended refrigeration setting for the Health Safety Cooler is 7-8 on the refrigeration control knob. 0 Royal Vision Cooler Health Safety Controller Information

Grille Assembly 8 7 4 6 5 Item Number Description Part Number Grille Frame, Top 7009 Grille Louver 700 Grille Frame, Bottom 700 4 Grille Frame, Left 7004 5 Grille Frame, Right 7005 6 Grille Mounting Bracket 7006 7 Door Switch 8509 8 Reset Button Assembly (includes all items below) 700 Reset Button Bracket 700 Reset Button 850 Machine Screw, #6- x.5 E9004 Keps Nut, #6- E90508 Royal Vision Cooler Health Safety Controller Information

Lock Assembly and Associated Parts (serial numbers beginning 06RA00007 and after) 6 7 5 4 Item No. Description Part No. Health Timer Lock Assembly 970 Insulated Pocket, Outer 96065 Vertical Panel Backer, Left, Full Length 97 Vertical Panel Backer, Left, Header Unit 9707 4 Insulated Pocket, Inner 96064 5 Emergency Release Button Panel 975 Assy., Full Length (includes the following five parts) Emergency Release Button Panel Assy., Header Unit (includes the following five parts) 9708 Item No. Description Part No. Vertical Pnl. Cover, Left, Full Length 97 Vertical Pnl. Cover, Left, Header Unit 970 Emergency Release Button 8579 Bushing 8000 Hex Jam Nut, 9/6-8 90509 O-Ring 85809 6 Latch Strike Housing 9705 Subassembly 7 Bottom Edge Guard 970 Royal Vision Cooler Health Safety Controller Information

Lock Assembly (serial numbers beginning 06RA00006 and before) 5 9 8 6 0 7 4 Item Number Description Part Number Lock Assembly, RVC Health Safety (includes items -0 below) 7040 Mounting Bracket 704 Solenoid Mechanism Assembly 709 Solenoid Cover 707 4 Screw, #8- x /8 E900 5 Keps Nut, #8- E90500 6 External Release Lever Assembly 7046 7 Bushing 8000 8 Hex Jam Nut, 9/6-8 E90509 9 Screw, #8- x /8 Hex Head E9006 0 Release Push Rod 705 Internal Release Lever Assembly (covers item 0 inside cabinet) 7045 Cable Retainer (covers harness to the Lock Assembly on the outside of the cabinet) 70 Royal Vision Cooler Health Safety Controller Information

Door Assembly (serial numbers beginning 06RA00007 and after) 7 5 4 6 Item Number Description Part Number Door Assembly, RVC Health Safety Ver., Header Unit (includes items -7) 97500 Door Assembly, RVC Health Safety Ver., Full Length (includes items -7) 9750 Cooler Door, Header Unit 8499 Cooler Door, Full Length 8506 Door Lock Assembly (includes items -7 below) 9700 Latch Protector 975 Lock 844 4 Lock Mounting Plate 970 5 Lock Latch, Health Timer Cooler 970 6 Lock Back Cover 709 7 Stop Nut, #8- E905004 Door Handle 8578 4 Royal Vision Cooler Health Safety Controller Information

Door Assembly (serial numbers beginning 06RA00006 and before) 4 5 Item Number Description Part Number Door Assembly, RVC Health Safety (includes items -5 below) 7050 Cooler Door 8499 Door Switch Strike 70500 Latch Assembly 7044 4 Molly Jack Nut, /4-0 906088 5 Machine Screw, /4-0 x /4, Hex Head, Black 907 Door Handle 8578 Royal Vision Cooler Health Safety Controller Information 5

Lower Cabinet Parts (serial numbers beginning 06RA00007 and after) 8 7 8 7 6 4 9 0 5 5 6 4 Item No. Description Part No. Health Safety Controller 8655 Ballast, Advance 8806 LED power supply 88057 Main Wiring Harness, Split 84767 4 Cable Clamp E9604 5 Evaporator Box Guide Plate 7044 6 EMI Filter 8406 7 Transformer 8805 8 Transformer Cover 978 9 Door Switch Base Bracket 7069 0 Door Switch Mounting Bracket 7070 Fuseholder Bracket 845 Fuse,.0 Amp Slo-Blow 84766 Switch, On / Off 8507 Item No. Description Part No. Wiring Cover 707 4 Bushing E9607 5 Health Timer Board Bracket 977 Assembly 6 Screw, #8- x /8 E900 7 Screw, #6- x /8 907 8 Cable Clamp, E96004 REFRIGERATION: Refrigeration Assembly, Health Safety, with Access Doors Refrigeration Control, Health Safety, RVCH-07 Refrigeration Control, Health Safety, RVCH-00 / -0 70470 8088 8089 6 Royal Vision Cooler Health Safety Controller Information

J4 J5 Lower Cabinet Parts (serial numbers beginning 06RA00006 and before) 4 5 J J J J6 J7 7 6 Item Number Description Part Number Transformer 8805 Health Safety Controller 8655 Board Cover Assembly 708 Fuseholder Assembly 845 Fuse,.0 Amp Slo-Blow 84766 4 EMI Filter 8406 5 Switch, On / Off 8507 6 Main Wiring Harness 84596 7 Fuseholder Bracket 70 HARNESSING: Harness, Door Switch and Reset Button, Grille Side 84760 Harness, Door Switch and Reset Button, Cabinet Side 8476 Harness, EMI Filter to Transformer and Lights 8476 Harness, Health Safety Board Power to Fuse and Transformer 8476 Harness, Health Safety Board to Solenoid 84764 Solenoid Termination 84765 REFRIGERATION: Refrigeration Assembly, Health Safety, with Access Doors 70470 Refrigeration Control, Health Safety, RVCH-07 8088 Refrigeration Control, Health Safety, RVCH-00 / -0 8089 Royal Vision Cooler Health Safety Controller Information 7

External and Internal Release of Door Lock (serial numbers beginning 06RA00006 and before) Both external and internal releases have been designed into the lock assembly. The following section outlines how to open the door using these releases. EXTERNAL RELEASE The external release is intended for use when power is lost to the Cooler and access to the inside of the cabinet is necessary. To use the external release, insert a pencil or similar object into the access hole located on the back of the lock assembly, as shown in the following illustration. Angle the pencil upward, then push down to release the door from the lock. External release access hole INTERNAL RELEASE The internal release is used if a person becomes entrapped in the Cooler s cabinet and cannot open the door. To use the internal release, simply press the internal release lever, as shown in the following illustration. The lever is located inside the cabinet directly adjacent to the lock assembly. 8 Royal Vision Cooler Health Safety Controller Information

Wiring Diagram RVCH-07 with Health Safety Controller (serial numbers beginning with 06RA00007 and after) LIGHT SWITCH ON OFF BLACK BLACK BLACK WHITE BALLAST LAMP OPTIONAL 0V LED CONFIGURATIONS ( & LAMP) LAMP ORIENTATION MAY VARY BY MODEL LIGHT SWITCH ON OFF N LED L N OPTIONAL 4VDC LED CONFIGURATIONS ( & LAMP) LAMP ORIENTATION MAY VARY BY MODEL LIGHT SWITCH ON POWER SUPPLY N L V-V+ LED V- V+ RVC 7(SINGLE LAMP), & 0 OFF BLACK WHITE BALLAST LAMP LIGHT SWITCH ON OFF N LED POWER SUPPLY N L V-V+ LED LAMP LED L LIGHT SWITCH ON OFF LED INPUT DC 4V V+ V- L V+V- INPUT DC 4V REMOTE RESET DOOR SWITCH NC COM COM NO NC NO DRAIN WIRE DOOR LOCK SOLENOID TXFMR 0VAC 4VAC FUSE KEY WHT GRN HEALTH SAFETY CONTROLLER ERROR SW 4 TEMP DOOR SOLND 4VAC LED DSPLY HB RESET REFRIGERATION CASSETTE 4 4 TEMPERATURE SENSORS AIR EVAP COMPRESSOR FAN HEALTH SAFETY CONTROLLER TEMP SENSOR ELECTRONIC TEMPERATURE CONTROL 4 5 6 COMPRESSOR EVAPORATOR FAN LINE RETURN (SMOOTH) LINE (RIBBED) MAINS JUNCTION BLOCK BLACK GREEN WHITE LINE GROUND NEUTRAL MAINS POWER IN LOAD ON FILTER LINE RIBBED 4 4 NEUTRAL (RIBBED) NEUTRAL (SMOOTH) NEUTRAL (SMOOTH) NEUTRAL (RIBBED) LINE (SMOOTH) LINE (RIBBED) NEUTRAL (SMOOTH) OFF SMOOTH MASTER SWITCH Royal Vision Cooler Health Safety Controller Information 9

Wiring Diagram RVCH-07 with Health Safety Controller (serial numbers beginning with 06RA00006 and before) LIGHT SWITCH ON OFF BLACK BLACK BLACK WHITE BALLAST LAMP RVC 7(SINGLE LAMP), & 0 BLACK WHITE BALLAST LAMP LIGHTING NOTES: - LED LAMPS MAY BE SUBSTITUTED FOR T8 FLUORESCENT LAMPS. - HIGH VOLTAGE LED, BALLAST IS REMOVED FROM DEPICTED CONFIGURATION. - LOW VOLTAGE LED, CLASS SWITCHING POWER SUPPLY (OUTPUT - 4VDC) REPLACES ELECTRONIC BALLAST. LAMP LOCATED IN FRONT GRILL REMOTE RESET NC NO COM COM NO NC 4 4 DOOR SWITCH TXFMR 0VAC 4VAC FUSE DFRST DSPLY DOOR 4VAC RESET RESET SNSR WHT KEY 4 HEALTH SOLND SAFETY CONTROLLER DRAIN WIRE DOOR LOCK SOLENOID 4 4 REFRIGERATION CASSETTE TEMPERATURE SENSORS AIR EVAP COMPRESSOR FAN HEALTH SAFETY CONTROLLER TEMP SENSOR ELECTRONIC TEMPERATURE CONTROL 4 5 6 COMPRESSOR EVAPORATOR FAN LINE RETURN (SMOOTH) LINE (RIBBED) MAINS JUNCTION BLOCK BLACK WHITE GREEN LINE NEUTRAL GROUND MAINS POWER IN LOAD FILTER LINE RIBBED 4 4 NEUTRAL (RIBBED) NEUTRAL (SMOOTH) NEUTRAL (SMOOTH) NEUTRAL (RIBBED) LINE (SMOOTH) LINE (RIBBED) NEUTRAL (SMOOTH) ON OFF SMOOTH MASTER SWITCH R 806 Rev. 0 June 0 Printed in the United States of America