Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Similar documents
Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-43 Extruded Airfoil Blade Control Damper

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Model VCD-20 3V CONTROL DAMPER

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-23 Low Leakage CONTROL DAMPER

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

VCD-23. Flange Options. Size Limitations

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-331 Combination Fire Smoke Dampers

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

HCD-230 Industrial Control Damper

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

Thermal Isolation. Break

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

HVAC Control & Balancing Dampers

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

HVAC Control & Balancing Dampers

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Air Measuring Products AMD AMS IAQ

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

ID-141x 12-Gauge Hat Channel Industrial Damper

Series HCD Airfoil Control Damper

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

BD-1600 Balancing/Zone Control Damper

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Motorized Fire Dampers

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Fusible Link (replaceable) Horizontal Mount

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

ARROW INDUSTRIAL PRODUCTS

Fusible Link (replaceable) Horizontal Mount

L O U V E R S & D A M P E R S

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

LOW LEAKAGE VOLUME CONTROL DAMPER

CFSD Series. Product Description

Installation, Operation, and Maintenance Instructions

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

PC-125x Counter-Balanced Backdraft Damper

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

AD-1250 Airflow Measuring Station

Blast Protection Damper

Blast Protection Damper

SECTION CONTROL DAMPERS

Introduction to Johnson Controls Dampers

VD-1600 Series Volume Control Dampers

Installation, Operation and Maintenance Manual

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

SD-1250 and SD-1600 Series Smoke Dampers

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

DAMPERS WE CONTROL AIR

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

ARROW UNITED INDUSTRIES

When Time is Everything... We Manufacture in Days - Not Weeks!

VOLUME CONTROL DAMPERS

AIR DUCT ACCESSORIES

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Transcription:

Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators are available. Model 3V Vertical Control Damper Ratings (See page 4 for specific limitations) Pressure: Up to 5.0 in. wg (1.2 kpa )- pressure differential Velocity: Up to 3000 (15.2 m/s) Temperature: Up to 250 F (121 C). Consult Greenheck for higher temperatures. H* Construction Standard Optional Frame Material Galvanized steel 304SS Frame Material Thickness Frame Type 16 ga. (1.5mm) x 1 in. (127mm x 25mm) hat channel 12 ga (2.7mm) Single flange, reversed flange or double flange Blade Material Galvanized steel 304SS Blade Type 3V - Linkage Axle Bearings Plated steel out of airstream, concealed in jamb Synthetic with thrush washers 304SS 304SS with thrush washers Axle Material Plated steel 304SS Paint Finishes - Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy Flange Options Single Flange Blade Operation W *W&H dimension furnished approximately 1 4 in. (6mm) undersize. Shown with optional extension pin and standoff bracket. Single Reversed Flange 1 1/2 in. (Typical) Double Flange Size Limitations W x H Minimum Size Single Section Maximum Size Multi-Section Inches 6 x 6 74 x 48 120 x 72 mm 152 x 152 1880 x 1219 3048 x 1829 1 1/4 in. maximum (typical) Features and Options: Wide range of electric and pneumatic actuators available. Factory installation available. Actuators (when supplied) are mounted on the top or bottom Low profile jambs are used on sizes less than 17 in. (432mm) high. R, C or O transitions Sleeves available 1 1/4 in. maximum (typical) Parallel Blades Opposed Blades Installation instructions available at www.greenheck.com

Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. D 4 (W) (H) 3.14 Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. 6D Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system.

Data AMCA 5.2 1000 0.05 1000 0.02 1500 0.11 1500 0.06 1500 0.05 2000 0.19 2000 0.10 2000 0.09 2500 0.29 2500 0.16 2500 0.14 3000 0.41 3000 0.23 3000 0.19 3500 0.55 3500 0.30 3500 0.27 4000 0.72 4000 0.40 4000 0.35 1000 0.04 1500 0.08 2000 0.15 2500 0.22 3000 0.32 3500 0.43 4000 0.56 1500 0.07 2000 0.12 2500 0.18 3000 0.26 3500 0.36 4000 0.47 AMCA 5.3 6D 1000 0.02 1000 0.02 1500 0.08 1500 0.04 1500 0.03 2000 0.13 2000 0.07 2000 0.06 2500 0.20 2500 0.11 2500 0.09 3000 0.29 3000 0.16 3000 0.13 3500 0.40 3500 0.21 3500 0.19 4000 0.51 4000 0.28 4000 0.25 1500 0.07 2000 0.12 2500 0.18 3000 0.26 3500 0.36 4000 0.46 1500 0.06 2000 0.10 2500 0.16 3000 0.22 3500 0.30 4000 0.39 AMCA 5.5 500 0.03 500 0.03 500 0.03 1000 0.13 1000 0.12 1000 0.12 1500 0.30 1500 0.26 1500 0.28 2000 0.53 2000 0.47 2000 0.50 2500 0.82 2500 0.75 2500 0.78 3000 1.19 3000 1.04 3000 1.12 3500 1.62 3500 1.41 3500 1.53 4000 2.10 4000 1.90 4000 2.00 500 0.03 1000 0.12 1500 0.27 2000 0.47 2500 0.75 3000 1.07 3500 1.45 4000 1.91 500 0.03 1000 0.12 1500 0.28 2000 0.49 2500 0.77 3000 1.12 3500 1.53 4000 2.01

Velocity Limitations Space Envelopes 74 60 Damper width (in.) 48 36 24 3000 2500 2000 12 0 0 12 24 36 48 Damper Height (in.) Space Envelopes D Optional Jackshaft On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the damper frame. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper is limited, each damper size should be individually evaluated. T B Damper frame Actuator Type/Model AFBUP (-S) and FSNF Series, Belimo MSxx20 Series, Honeywell; 33x- 2976 Series, Siemens FSLF, LF and TFB Series, Belimo MSxx04 & MSxx09 Series, Honeywell MS75xx Series, Honeywell 33x-4551 Series, Siemens 331-2856, Siemens Width T B D Inches (mm) Inches (mm) >6 to <10 0 12.75 6 >10 to <18 0 2 6 >18 0 0 6 >6 to <10 0 3.5 6 >10 0 0 6 >6 to <9 0 4.75 6 >9 0 0 6 >6 to <10 0 12.75 6 >10 to <18 0 7 6 >18 0 0 6 >6 to <10 0 7.5 6 >10 to <17 0 1.5 6 >17 0 0 6 <12 N/A N/A N/A >12 to <18 0 2.5 9 >18 0 0 9

Specifications Actuator This drawing depicts the worse case clearance requirements for an actuator with a jackshaft. 5 3/8 in. (136.5mm) 3 3/4 in. (95mm) 7 3/4 in. (197mm) (127mm) Mounting External - includes extension pin (standoff bracket optional) External kit - actuator and all mounting hardware Internal - blade lever 1 1/4 in. (32mm) max. Specifications Control dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Damper blades shall be 16 ga. (1.5mm) galvanized steel 3V type with three longitudinal grooves for reinforcement. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow and operation in either direction through the damper (blades that are non-symmetrical relative to their axle pivot point or utilize blade stops larger than 1 2 in. [12.7mm] are unacceptable). Linkage shall be blade-to-blade concealed in jamb (out of the airstream) to protect linkage and reduce pressure drop and noise. Damper frame shall be 16 ga. (1.5mm) galvanized steel formed into a structural hat channel shape with reinforced corners to meet 11 ga. (3mm) criteria. Bearings shall be corrosion resistant, permanently lubricated, synthetic (acetal) sleeve type rotating in extruded holes in the damper frame for maximum service. Axles shall be square and positively locked into the damper blade. Damper manufacturer's printed application and performance data including pressure, velocity and temperature limitations shall be submitted for approval showing damper suitable for pressures to wg (1.2 kpa), velocities to 3000 (15.2 m/s) and temperatures to 250 F (121ºC). Basis of design is model. Copyright 2017 Greenheck Fan Corporation Rev. 16 January 2018