S&C Manual PME Pad-Mounted Gear

Similar documents
DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV

SPECIFICATION BULLETIN

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV

S&C Recloser Bypass Disconnects

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Cleaning Flooded Gear

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Specifications. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv)

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

A. The ratings for the integrated pad-mounted gear shall be as designated below:

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Installation. S&C Manual PME Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) Table of Contents

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

WARNING. TYPE PSI/II PAD-MOUNT SWITCHGEAR with Non-Loadbreak Fuse Mountings 15kV 25kV INSTRUCTIONS. Qualified Persons. For Installation and Operation

S&C Loadbuster Disconnects

DEADFRONT VACUUM INTERRUPTER PAD-MOUNTED SWITCHGEAR 15kV 25kV

Underground Distribution Switchgear

15 kv and 25 kv Thru-Bushings

SWITCHGEAR DIVISION PRODUCT PROFILES

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

25 kv Apparatus Bushings

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Specifications. S&C Source-Transfer PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) With Micro-AT Control. Conditions of Sale

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Outdoor Padmount Switching Products

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Type MOST oil switch

Underground Distribution Switchgear

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

C1000 Series Automatic Cap Bank

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

SWITCHGEAR DIVISION PRODUCT PROFILES

15-kV Safefront 200 Amp Primary Transformer Station Pad-Mounted Outdoor

Medium Voltage Metal-Enclosed Switches

15-kV Safefront 200 Amp Source Isolated Cable Switching Station Pad-Mounted Non-Fusible

Underground Distribution Switchgear

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

100 / 110 DRYWELL FUSE SPECIFICATION

25-kV Safefront Mini-Switch Phase Isolated Pad-Mounted Switchgear 125 Amp (Max) Clip-Mounted Current-Limiting Fuses

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

S&C Switch Operators Types AS-1A and AS-10

INSTRUCTIONS Ç CAUTION. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) For Installation TABLE OF CONTENTS

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Medium Voltage Metal-Enclosed Switches

Horizontal Circuit Switchers

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Typical Specification

AUTOMATIC-TRANSFER PAD-MOUNTED SWITCHGEAR LIVE-FRONT - TYPE ATPSI/II DEAD-FRONT - TYPE ATPSE 15kV 25kV

15-kV Safefront 600 Amp Primary Transformer Station Pad-Mounted Outdoor

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

Copper Vertical Break Switch kv A.

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Aluminum Vertical Break Switch kv A.

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

Cleaning Flooded Gear

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

7. SERVICES OVER 600 VOLTS

Submersible Vacuum Fault Interrupters

Copper Double Break Switch

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Horizontal Circuit Switchers

Product Specifications for Aluminum Vertical Break Switches

Padmount Solid Dielectric Switchgear Catalog

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

INSTRUCTION MANUAL #103

Transcription:

S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv

S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation, in-air switching, and quick, convenient, fuse handling to elbow-connected gear. Switch and fuse components are protected and isolated within an inner air-insulated, grounded, steelenclosed component compartment that provides excellent resistance to entry of foliage, wildlife, and contaminants, and reduces exposure of the public and operating personnel to energized live parts. Switch terminals are equipped with 600-ampere bushings and fuse terminals are equipped with 00-ampere bushing wells that have interfaces designed in accordance with IEEE Standard 86 to accept all standard elbows and accessories. Bushings and bushing wells are mounted a minimum of 5 inches above the base of the gear... all elbows may be readily operated at a convenient angle from a standing position. The termination compartments are accessible through doors equipped with the S&C Penta-Latch Mechanism the automatic door-latching system. Three-phase in-air switching of source circuits is accomplished with externally operable S&C Mini- Rupter Switches. Large viewing windows in switchtermination compartments allow visual verification of switch-blade position there s no need to move the 600-ampere elbows to establish working clearances. Fuse access is provided by the S&C TransFuser Mounting. This mounting incorporates a unique fusehandling mechanism that allows easy movement of fuses to the open, de-energized position for ready access. These mountings accommodate a choice of S&C Type SME-0 and SME-Z Power Fuses, S&C Fault Fiter Electronic Power Fuses, or a variety of current-limiting fuses. Completely Encased Medium-Voltage Components No exposed energized components in either switch or fuse termination compartments Inner grounded steel compartment encases the Mini-Rupter Switches, fuses, and interconnecting bus Moisture and contamination control... there are no direct air paths into the component compartments Resilient gasketing seals roof to compartment bulkheads and enclosure walls Insulating no-drip undercoating checks roof condensation Dense closed-cell gaskets seal TransFuser Mountings to compartment bulkhead Foliage and wildlife control Galvanized steel floor prevents entry from bottom of component compartment Side-view cross section of Model PME-9.

Switch Compartments A B C D E F G A B C D E F G Wide-view, unbreakable, mar-resistant windows let you verify switch position and check for visible break. 600-Ampere Cypoxy bushings have interfaces in accordance with IEEE Standard 86. Corrosion-resistant non-ferrous door hinges and hinge pins. Penta-Latch Mechanism provides vandal-resistant, automatic, three-point door latching. Uncommonly rugged and fully coordinated with padlocking provisions. Ground rod extends full width of each switch compartment doors may be closed with grounding clamps in place. Segregated compartments steel barriers isolate side-by-side cable compartments. Deep, spacious termination compartments accommodate a wide range of elbows and accessories with the doors closed. Mini-Rupter Switches S&C Mini-Rupter Switches, rated 600 ampere continuous, provide controlled circuit interruption by deionizing action within the unique arc compressors there is no external arc or flame. The switches handle all your three-pole loop splitting load dropping requirements up through 600 amperes at. kv and 5 kv. And the.-kv Mini-Rupter features a 5,000 ampere short-circuit rating, in addition to having a 5,000 ampere three-time duty-cycle fault-closing rating. 5-kV Mini-Rupters are rated,500 amperes and carry a,500 ampere three-time duty-cycle fault-closing rating.

Fuse Compartments A B C D E F G H A B C Viewing windows allow easy checking of blown-fuse indicators. S&C s Ultradur finishing system withstands more than,000 hours of salt-spray testing compared to industry-standard,500 hours. Generous spacing of bushing wells and parking stands accommodates a full spectrum of elbows, portable feed-thrus, and accessories. D E F G Three-piece roof design features hinged sections over cable compartments, allows cables to be pulled up through the roof opening, makes installation quicker and easier. 00-Ampere Cypoxy bushing wells have interfaces in accordance with IEEE Standard 86. Fuse-storage feature accommodates spare fuse assemblies. Ground rings are readily accessible in up-front location. Enclosure doors may be closed with grounding clamps in place. H Up-front access to fuses takes the hassle out of fuse changeout. With an almost eortless pull, TransFuser unlatches and pivots to its open position, making the de-energized and isolated fuse accessible for easy replacement. Fuses Type SME-0 Power Fuses, featuring the S&C SMU-0 Fuse Unit, and Type SME-Z Power Fuses, featuring the S&C SM- Refill Unit are widely applied on utility systems. They oer a broad selection of ampere ratings and time-current characteristics (TCCs), permitting close fusing of loads for full-faultspectrum protection and optimum coordination. Fault Fiter Electronic Power Fuses, with their unprecedented variety of unique TCCs, provide superior protection and precise coordination in a wide range of applications. Fault Fiter Electronic Power Fuse Mountings also accommodate a variety of non-s&c-manufactured single-barrel current limiting fuses.

TransFuser Mountings The unique TransFuser fuse-handling system takes the work out of fuse replacement. Operators are not directly exposed to energized live parts. Moving the loadbreak elbow to a feedthru or stando insulator on the parking stand, interrupts any fuse load. This allows the mechanical interlock to be raised, unlocking the TransFuser Mounting. An almost eortless pull unlatches the TransFuser Mounting. The superbly balanced mounting virtually self-pivots to its open position and latches in place. It s a swift, controlled action that guards against exposure to energized live parts. 5 In the open position, the deenergized and isolated fuse is accessible to the operator for replacement. Panel seals out contaminants from entering medium-voltage area while fuses are being changed. 5

Hinged Roof The three-piece roof design features hinged sections over the cable compartments. The hinged roof allows cables to be pulled up through the roof opening, rather than the door openings, making installation easier and quicker. A mechanical interlock prevents full engagement of the Penta-Latch Mechanism unless the hinged roof section is closed and latched. Hinged roof detail. Overall view of gear with hinged roof. Exceptional Durability -Gauge Steel Construction The enclosure is fabricated from rugged -gauge steel sheet. All structural joints are welded there are no externally bolted panels to invite removal. S&C s Ultradur Finish Protecting the steel is S&C s Ultradur Finishing System an extremely tough, uniform finish that is, through baking, ceramic-like in performance and appearance. It resists underfilm propagation of corrosion, guards against the widest variety of atmospheric contaminants, resists moisture damage, and withstands exposure to ultraviolet rays without chalking. 6

Penta-Latch Mechanism Provides vandal-resistant, automatic, three-point door latching. Uncommonly rugged and fully coordinated with padlocking provisions. Two-Step Controlled Opening of Doors Precision recessing and spring loading of pentahead actuator discourage tampering Protective hood shields padlock shackle from vandals Unlock padlock and remove it from door-locking tab. Double Security for Extra Vandal Resistance A single motion of a pentahead wrench unlatches the Penta- Latch Mechanism for opening and simultaneously recharges it in preparation for closing. Closing the door releases the charged Penta- Latch Mechanism, automatically latching the door at three points and securing the pentahead actuator. Only after the door is latched and the pentahead actuator is secured in this manner can the padlock be installed completing the full two-step security system. 7

Circuit Configurations Seven models of S&C Manual PME Pad-Mounted Gear provide you with a choice of circuit configurations for switching and protection of your underground distribution system. PME- PME-5 PME-6 PME-9 PME-0 PME- PME- Ratings Voltage, kv Current, Amperes Short-Circuit Nom. Max BIL 7.5 Fuse Type Fuse Mini-Rupter Switch Current, Amperes Max None Cont. Load Dropping One-Second Short-Time Withstand, RMS, Sym. Peak Withstand, Peak MVA 5 000 65 000 60. 7.0 SME-0 00 000 6 00 50 95 600 600 7.0 SME-Z 00 500 500 0 7.0 Fault Fiter 00 000 6 00 50 None 500 500 50 5 7l 5 SME-0 00 600 600 500 500 50 SME-Z 00 500 500 50 Fault Fiter 00 500 500 50 l 9 kv when furnished with Fault Fiter Electronic Power Fuses. When furnished with current-limiting fuses having a rated maximum interrupting current of at least 5,000 amperes, RMS, symmetrical, and limiting the instantaneous peak let-through current to less than 6,000 amperes, this gear has the following short-circuit ratings: 5,000 amperes, RMS, symmetrical, one-second short-time withstand current; 65,000 amperes, peak, peak withstand current; 60 MVA, three-phase symmetrical, at rated nominal voltage. Applicable to solidly grounded-neutral systems only, with fuses connected by single-conductor, concentric-neutral-type cable to a transformer(s). For all other applications this gear has the following short-circuit ratings: 9,00 amperes, RMS, symmetrical, one-second short-time withstand current; 5,000 amperes, peak, peak withstand current; 05 MVA, three-phase symmetrical, at rated nominal voltage. The Rural Utilities Service has accepted all S&C Manual PME Pad-Mounted Gear. UL-listed.-kV models are optionally available. Printed in U.S.A. Descriptive Bulletin 665-0 November 9, 009 Oices Worldwide f www.sandc.com