Supercal 539. Compact thermal energy meter

Similar documents
Superstatic 749. Fluidic Oscillation Compact Heat Meter

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Fluidic Oscillation Compact Heat Meter

Supercal 539 Universal compact heat meter

Compact Static Heat Meter of High-Tech Composite

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 440. Static Heat- and Cooling Meter. Application

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Measuring capsule heat meter G54 / G55

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters

Electronic Heat Meters

WZMC-402 Ultrasonic Apartment Energy Meters

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

RAY COMPACT ENERGY METER MECHANICAL

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

CORONA E ELECTRONIC METER MULTI-JET

Heat Meter Integrator

M-bus impeller type heat and heat/refrigeration meters

Horizontal Distribution Units - HDU Multi-port

tprime TM Series 280T

Electronic Water Meters in measuring cell design

ULTRASONIC HEAT METER

Electronic Water Meters

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Electronic Water Meters

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

ULTRASONIC METER FOR HEATING AND COOLING SKU-03

zelsius Installation and operating manual All that counts. EnergyMetering

TOPAS PMW-basic. Customer benefits. Product features

F 90 Heat Meter Warmly recommended to cool-headed economisers

WESAN WPV E ELECTRONIC METER WOLTMAN

aquaconcept Product features Customer benefits

zelsius Installation and operating manual All that counts EnergyMetering

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Residential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing

MULTICAL 6M2. Data sheet

REQUIRED TOOLS 3 mm screw driver Wrench Crosstip screwdriver

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Radio. Manual Electronic Heat Cost Allocator

Heating Cost Allocation Valve with local acquisition of the flow temperature

Heat / Chill Meter PolluCom M Installation and Operating Instructions. PolluCom M. Installation and Operating Instructions. M H 1210 INT, Page 1

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

Heating and Cooling Catalog

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

Design and application

Heating / Cooling Meter PolluCom E Installation and Operation Instructions

CORONA ER ELECTRONIC METER MULTI-JET

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

SonoSensor 30 Ultrasonic flow sensor

Datasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Sontex Energy Meter. Technical Databook. Belimo Asia Pacific

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features

TOPAS PMW-basic Hot water meter

COUNTIS E22 Three-phase energy meter Direct - 80 A

Level Measurement Point level measurement - RF Capacitance switches

7E x0. Nominal current 5 A (32 A Maximum) 1-phase 230 V AC 17.5 mm wide

Temperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

a q u a c o n c e p t Applications Features Benefits

OPERATING INSTRUCTIONS

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Residential Water Meters

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

3 Specification Magneta Smedegaard

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Electromagnetic Flow Monitor magphant

Magnetic-inductive flow meter for hazardous areas

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

ELSTER KENT Non-Metalic Products. Meters, Meterboxes & Accessories made from Engineering Plastics

microclima/sensostar 2/2+ MSH

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

SHARKY FS 473 ULTRASONIC FLOW SENSOR

4 Specification Magneta Smedegaard twin pumps

Stand alone 4/3, 4/2 solenoid operated directional valve

Differential pressure gauge Model , copper alloy Model , stainless steel version

5" SUBMERSIBLE PUMPS. by Franklin Electric

Smart Pressure Transmitter

Temperature sensor type T.3., Construction type 3, plug-in sensor for protection tube with lateral cable outlet (Pt100/Pt1000, NTC)

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Digital Flow Switch (Sensor Part) Operation Manual

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Transcription:

Supercal 539 Compact thermal energy meter Application Electronic, battery-powered compact thermal energy meter intended to record heat consumption in autonomous heating systems or combined heating/cooling systems. The Supercal 539 compact thermal energy meter is used to measure heat energy or combined heating/cooling energy. The main area of application is a central heating or heating/cooling system that distributes heat or heat/cool to individual consumer and are billed based on the energy measured by the meter. With its two additional and optional pulse inputs (for the connection of water meters for example) the integration of a low cost system becomes a reality Areas of applications: Urban heating stations The heating of one or several buildings in an urban Offices and administration buildings Malls Houses Low-energy The compact thermal energy meter Supercal 539 meets the requirement s of European Standard EN 1434 (Class 3) Sontex SA 2605 Sonceboz Switzerland Tel +41 32 488 30 00 Fax +41 32 488 30 01 Email sontex@sontex.ch www.sontex.ch 1

Functions Variants Recording heat or heat/cool consumption by means of measuring the flow and temperature difference. Connecting two additional pulse inputs to the optical interface, M-Bus or radio system. Displaying consumption data: - Displaying 15 monthly energy and volume values - Displaying 15 monthly cooling energy - Displaying 15 monthly values of additional pulse input 1 - Displaying 15 monthly values of additional pulse input 2 - Displaying operating data - Self-monitoring with error display Supercal 539 Plus Optical interface and two pulse inputs Optical interface, one pulse output for energy and two additional pulse inputs Optical interface, M-Bus and two additional pulse inputs Optical interface, bi-directional radio with two additional pulse inputs Supercal 539 heating cooling: combined heating cooling meters Optical interface Optical interface, two pulse outputs for heating and cooling energy Optical interface and M-Bus Optical interface and bi-directional radio Supercal 539 heating and cooling Plus Optical interface, two pulse outputs for heat and for cool energy and one additional pulse input. Optical interface. M-Bus and one additional pulse input. Optical interface, bi-directional radio with one additional pulse input. Special version Main feature Energy unit: MWh, GJ Mounting in supply flow Easy to operate and read. Non-volatile EEPROM memory. 15 monthly energy values for heat energy, volume, cooling energy and for the additional pulse inputs 1 and 2. The Supercal 539 is suitable for all communication environments: - Optical interface, M-bus (as per EN 1434) and Radio. - Optional additional pulse inputs for low cost system integration. - Many years of reliable operation thanks to new contact flow sensor. - New energy-saving technology of the permanently connected Pt10 000Ω measuring unit. - The sensor mounting point is integrated into the flow sensor. - The Supercal 539 includes the functions necessary for self-monitoring, as well as for monitoring operating station. - Can be installed in supply or return flow Sontex SA 2605 Sonceboz Switzerland Tel +41 32 488 30 00 Fax +41 32 488 30 01 Email sontex@sontex.ch www.sontex.ch 2

Design Flow sensor Integrator Temperature sensor The compact heat meter consists of a single jet flow sensor with magnet, a detection circuit for the magnet, an integrator and a temperature pair. The inlet fitting includes a filter to hold any larger impurities. The flow sensor complies with state-of-the-art technology. Thanks to the high quality standard, many years of operating reliability are guaranteed. The flow sensor operates in the dry, and the impeller wheel is equipped with a special hard metal bearing. As only the impeller wheel works in the wet area, problems that might be caused by impurities in the water are largely excluded. The sensor mounting point is integrated into the flow sensor. The integrator is equipped with a 7-digit LCD display and can be rotated through 360. In standard metering operations the battery l ife of up to 6 years can be guaranteed. The temperature sensor pair Pt10 000Ω is permanently connected to the measuring unit. The return flow sensor is built into the sensor mounting position in the flow sensor as standard. The supply flow sensor can be mounted directly or by means of sensor pockets Sontex SA 2605 Sonceboz Switzerland Tel +41 32 488 30 00 Fax +41 32 488 30 01 Email sontex@sontex.ch www.sontex.ch 3

Display The LCD display on the Supercal 539 has a large, clear design making it easier to read Monthly value index Flow temperature Impeller wheel in operation Return temperature Communication Service level 3 m /h GJ kwh MWh LCD display Units energie volume cooling energie additional meter 1 additional meter 2 service kwh m3 40 60 80 8888 previous months 1 01-kWh 01-m3 41 61 81 h rruning hours previous months 2 02-kWh 1-1 02-m3 1-1 1-1 42 1-1 62 1-1 82 1-1 C low temperature previous months 3 03-kWh 03-m3 43 63 83 C high temperature previous months 4 04-kWh 04-m3 44 64 84 C different temperature previous months 5 05-kWh 05-m3 45 65 85 m3/h actual flow previous months 6 06-kWh 06-m3 46 66 86 kw actual power previous months.. 1234 fabrication number previous months 15 15-kWh 15-m3 55 75 95 Adr M-Bus adresse - Error messages Error code Description Remedial action Err 1 Water meter faulty Return to manufacturer Err 2 Temperature sensor faulty Return to manufacturer Err 3 Electronics faulty Return to manufacturer Sontex SA 2605 Sonceboz Switzerland Tel +41 32 488 30 00 Fax +41 32 488 30 01 Email sontex@sontex.ch www.sontex.ch 4

Technics Measuring principle Energy calculation The medium flowing through the system drives the impeller wheel and the rotational speed is scanned electronically using a magnet. The temperature difference in the supply and return flows is measured with a pair of platinum temperature sensors (Pt 10'000). The flow sensor records the flow and the pair of temperature sensors records every two minutes the supply and return flow temperatures. Using a microprocessor, the integrator calculates the temperature difference and then calculates the thermal energy, respectively the heating/cooling energy, consumed using the average flow and the heat coefficient. Cooling energy consumption The cooling energy is memorized in a separate register. The cooling energy is cumulated when the two following conditions are met: ( t) Temperature difference -0.5K Supply temperature 18 C The temperature threshold value is parameterized at the factory at 18 C. The threshold value can be changed 1 C-levels. The cooling energy is updated every minute and has the same unit. When the supply temperature is lower than the return temperature, the signal will indicate the ( ) negative symbol. Non-volatile memory Monthly values Pulse Inputs The device parameters, as well as the cumulative values for energy and volume, operating hours and error type are stored in a non-volatile memory (EEPROM), and this information is not lost in the event of a power failure (e.g. changing batteries). Once a day and in the event of battery failure, the cumulative values are updated in the EEPROM. On the first of the month the 15 monthly energy values for heat energy, volume, cool energy and for the additional pulse inputs 1 and 2 are stored in the integrator depending on the variant. The Supercal 539 Plus offers in option the possibility of up to two additional pulse inputs for low cost system integration. Communication options The additional pulse inputs and outputs are equipped with a 1.5 m long cable. A splash proof distribution box (minimum IP54) is foreseen for the connection of the pulse inputs, outputs and of the M-Bus. The additional parameterization, other than the ex factory settings, of the Supercal 539 can be carried out with the free sofware Prog539 available from Sontex or its agents. Sontex SA 2605 Sonceboz Switzerland Tel +41 32 488 30 00 Fax +41 32 488 30 01 Email sontex@sontex.ch www.sontex.ch 5

Technical data Flow metering Nominal flow qp 0.6 m 3 /h 1.0 m 3 /h 1.5 m 3 /h 1.5 m 3 /h 2.5 m 3 /h Maximum flow qs 1.2 m 3 /h 2.0 m 3 /h 3.0 m 3 /h 3.0 m 3 /h 5.0 m 3 /h Minimum flow qi Horizontal mounting 12 I/h 10 l/h 15 l/h 15 l/h 25 l/h Vertical mounting 24 I/h 20 l/h 30 l/h 30 l/h 50 l/h Starting point < 3 l/h < 3 l/h < 5 l/h < 5 l/h < 8 l/h Nominal pressure 16 bar 16 bar 16 bar 16 bar 16 bar Pressure loss at qp p 0.23 bar 0.23 bar 0.23 bar 0.23 bar 0.23 bar Pressure lost curves Pressure loss (bar) Flow (m 3 /h) Metrological class EN 1434 Class 3 Mounting Nominal width DN 15 mm 15 mm 15 mm 20 mm 20 mm Connecting thread G ¾ B G ¾ B G ¾ B G 1 B G 1 B Mounting length 110 mm 110 mm 110 mm 130 mm 130 mm Long-term operating temp. 90 C Short-term operating temp. 110 C Temperature measurement Temperature sensors Pt10 000Ω Integrator sensor 0-110 C Temperature difference range t 3-75K Minimum starting value 0.5K Power supply Pulse outputs Lithium battery, 3.6 V Open collector 1 Hz 500 ms Pulse inputs Power Supply 3.6V DC R pull UP 1 MΩ Pulse values 1, 2.5, 5, 10, 25, 50, 100, 250 Thermal energy meter Environmental class A Battery protection class III Housing protection class IP54 as per DIN VDE 0470, Part 1 Permissible temperatures: Transport and storage -10-60 C (dry) Operation 5-55 C ** Data memory non-volatile Display LCD, 7-digit Weight 0.8 kg ** The average annual permissible temperature with the radio option is 40 C Sontex SA 2605 Sonceboz Switzerland Tel +41 32 488 30 00 Fax +41 32 488 30 01 Email sontex@sontex.ch www.sontex.ch 6

Installation instructions Local regulations regarding the use of thermal energy meters must be observed. The pipework must be flushed through before installing the meter. Both temperature sensors and all screw pipe joints must be fitted with seals. It is recommended to fit the thermal energy meter between two shut-off valves. The information given on the identification plate must be observed. It is essential to pay attention to the isolation instructions in order to avoid the accumulation of condensation in the integrator or a any capillary effect on the temperature sensor cable. Operating instructions Basically, the battery must be replaced in the event of re-certification or repair. Dimension diagram and installation recommendations Masszeichnung, dimesion in mm Einbau in T-Stück mit Tauchhülse Installation with t-fitting and protection pockets Isolationsvorschrift, Isolation instruction 76 mm 83 mm L D 59 mm 45 10 2.0 SW 17 3/8" 8.0 16.0 46.5 45 mm 76 mm L qp 0.6 1.0 1.5 1.5 2.5 L 110 110 110 130 130 D G¾" G¾" G¾" G1" G1" 5 Ø T-Stück 3/4" x 3/8" x 3/4" Technical Support For technical support contact your local Sontex agent or Sontex SA directly. Hotline Sontex: sontex@sontex.ch +41 32 488 30 04 Conformity according to R&TTE 1999/5/CE The detailed certificate of conformity can be found on our homepage www.sontex.ch Technical modifications subject to change without notice Data Sheet Supercal 539 EN 09-06-2010 Sontex SA 2007 Sontex SA 2605 Sonceboz Switzerland Tel +41 32 488 30 00 Fax +41 32 488 30 01 Email sontex@sontex.ch www.sontex.ch 7