McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

Similar documents
McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay Central Station Air Handler Medium Pressure MSL

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

Complete HVAC Capability

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

McQuay Climate Control Singer

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

FHP MANUFACTURING PARTS PRICE LIST

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

FHP MANUFACTURING PARTS PRICE LIST

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

Tube Axial Fan Page Specifications & Dimension Data Performance Data

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

DESIGN GUIDELINES FANS PAGE 1 of 7

Centrifugal Utility Fans - SFD/SFB

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

TORIN by: AIRDEX Index Page No.

FILTERED AIR SUPPLY FANS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

BAC, BAF, BAH Central Station Air Handlers

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Twin City Fan & Blower

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Installation, Start-Up and Service Instructions

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.


Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Fixed Pitch Vane Axial Fan

SECTION AXIAL HVAC FANS

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

& 12" 96" / TABD CATALOG

REPLACEMENT PARTS MANUAL

Parts List. Modular Crescent Cuber. Models KM-1340MAH, MWH, MRH/3. hoshizakiamerica.com

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

Transcription:

Replacement Parts List No. 055222700 Revision D 0/205 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 37-72 Vintage C Last Manufactured: 984 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

Table of Contents Parts List Revision History... 3 Model Number Nomenclature... 4 Serial Number Nomenclature... 5 Unit Code Index...6-8 Coil Notes... 9 Sample Contractor Coil Code Strings... 9 Fan Section Assembly Diagram... 0 Components... Variable Inlet Vanes (Airfoil Fans Only) Diagram & Assemblies... 2 Components... 3 Low Leak Dampers Diagram & Assemblies... 4 Components... 5 Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 2

Parts List Revision History Revision Date Description A 2/99 Page 3 - Added Revision History page. Page 4 - Corrected location of Bubble # and Bubble #2. Page 5 - Added Airfoil Note above Bubble #. Added "Airfoil" to Blower Wheel descriptions (Bubble # and #2). Corrected part number for 2-/6" Drive Shaft (Bubble #4). B 3/02 Page 5 - Moved up the notes at the bottom of the page. No change in contents with exception of new revision. C 5/0 Converted file to current software and corrected formatting errors. Updated Cover and Revision page with current design logo. Reorganized form into sections and updated TOC. Page 4: Added Model Number Nomenclature section. Page 5: Added Serial Number Nomenclature section. Page 6-8: Added Unit Code Index section. Page 9: Added Coil Section. Page : Changed footnote # to: "Part numbers ordered per Code Item on original G.O. Contact McQuay Parts with model and serial number information so the needed part(s) can be correctly identified." Page 2: Changed footnote # to: "Assemblies include: Rods, Shafts, Bearings, Hardware & Miscellaneous Parts. For individual linkage parts, see Variable Inlet Vane Components listing." Page 4, 5: Added Low Leak Damper section. D 0/5 Cover, Rev pg.: Updated to Daikin Applied logo format. Various: Changed "McQuay Parts" to "Daikin Applied". Page 9: Rewrote coil notes. Reorganized page contents. Updated TOC. Page 4: Rewrote footnote #. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN 55440 (763) 553-5330 Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 3

Model Number Nomenclature LSL 37 C H Unit Type First Letter = Blower Section Second Letter = Unit Type Third Letter = Coil Section LSL = Low Pressure, Single Zone, Low Pressure MSL = Medium Pressure, Single Zone, Low Pressure LML = Low Pressure, Multi Zone, Low Pressure MMM = Medium Pressure, Multi Zone, Medium Pressure LWL = Low Pressure, Water Sprayed Coil, Low Pressure MWL = Medium Pressure, Water Sprayed Coil, Low Pressure LYF = Low Pressure, Ventilating, Draw Thru LHD = Low Pressure, Heating and Ventilating, Draw Thru Air Intake into Blower Section H = Horizontal Air Intake V = Vertical Air Intake I = Inverted Number of Fans Nominal Coil Face Area (in Square Feet) Vintage Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 4

Serial Number Nomenclature 3 Z F 2345 00 Plant Identification 3 = Faribault, MN 9 = Scottsboro, AL Engineering Revision Sequence Number Year of Manufacture A = 97 R = 986 B = 972 S = 987 C = 973 T = 988 D = 974 U = 989 E = 975 V = 990 F = 976 W = 99 G = 977 X = 992 H = 978 Y = 993 J = 979 Z = 994 K= 980 5 = 995 L = 98 6 = 996 M = 982 7 = 997 N = 983 8 = 998 P = 984 9 = 999 Q = 985 Month of Manufacture A = January J = September B = February K = October C = March L = November D = April M = December E = May F = June G = July H = August Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 5

Unit Code Index Code 03= Fan Wheel and Housing A= Forward Curved Steel Wheel B= Forward Curved Aluminum Wheel C= Forward Curved Hot Dipped Galvanized Wheel D= Airfoil Wheel E= Forward Curved Steel Wheel with Mechanical Speed Control F= Airfoil Wheel with Mechanical Speed Control L= Forward Curved Wheel with Variable Inlet Vanes V= Airfoil wheel with Variable Inlet Vanes Code 04= Unit Arrangement Digit, Unit Arrangement H= Horizontal V= Vertical I= Inverted Digit 2, Cabinet (Does not apply to LSL/MSL) = Standard Fan Cabinet Digit 3, Unit Options (Does not apply to LSL/MSL) 0= Basic Unit LH Air Intake (LYF Only) 0= Basic Unit LH, Bottom, or Top Air Intake (LHD Only) 0= Horizontal Discharge LH air Intake (LML/MMM Only) = Basic Unit RH Air Intake (LYF/LHD Only) = Horizontal Discharge RH air Intake (LML/MMM Only) 2= Vertical Discharge LH air Intake (LML/MMM Only) 3= Vertical Discharge RH air Intake (LML/MMM Only) 4= Internal Face & Bypass Top LH Air Intake (LHD Only) 5= Internal Face & Bypass Top or RH; RH, Bottom or Top Air Intake (LHD Only) 6= External Face & Bypass Top or LH Duct; LH, Bottom or Top Air Intake (LHD Only) 7= External Face & Bypass Top or RH Duct; RH, Bottom or Top Air Intake (LHD Only) 8= External Face & Bypass Bottom Duct; LH Air Intake (LHD Only) 9= External Face & Bypass Bottom Duct; RH Air Intake (LHD Only) Digit 4, Section Options (Does not apply to LSL/MSL) = No Access or Auxiliary Coil Section = No Access or Auxiliary Coil Section w/ or 2 Row Coil (LHD Only) 2= Leaving Air Access Section, no Auxiliary Coil Section 3= No Access Section w/ Auxiliary Coil Section 4= Entering Air Acess Section w/ Auxiliary Coil Section 5= Leaving Air Access Section w/ Auxiliary Coil Section 8= No Access or Auxiliary Coil section w/ a 3 or 4 Row Coil Code 05= Mounting Arrangement A= Top Mounting Holes B= Bottom Mounting Holes Code 06= Fan Discharge and Motor Location = CH 4= CCBH 7= CD 2= CCH 5= CU 8= CCD 3= CBH 6= CCU Code 07= Motor Location Contact Daikin Applied if more information is required. Code 09= Unit Voltage = 5/60/ 2= 230/460/3 29= 230/60/3 2= 200/60/3 27= 460/60/3 37= 575/60/3 6= 5/230/60/ 28= 380/50/3 Code 0= Motor Base and Bearings = Rigid base, Ball Bearing Code = Motor RPM and Enclosure A= 800 RPM, Open Dripproof B= 800 RPM, Totally Enclosed Fan Cooled C= 800 RPM, Explosion Proof D= 800/900 RPM, Two Speed, One Winding E= 800 RPM, Open Dripproof High Efficiency Code 2= Motor Mounting = Factory Mounted Motor 2= With Motor, Field Mounted 3= Factory Mounted Motor 50HZ 4= With Motor, Field Mounted 50HZ Code 3= Fan/Fan Mount/Drive Selection Digit, Fan and Drive Type Selection A= Variable Speed Drive (3-0HP LSL/MSL Only) B= Standard Forward Curve Fan, Isolated Fan mount, Variable Speed Drive C= Optional Forward Curve Fan, Variable Speed Drive D= Airfoil Fan, Variable Speed Drive F= Airfoil Fan, Fixed Drive or Maxi-Drive F= Fixed Drive (5-75HP LSL/MSL Only) L= Standard Forward Curve Fan, Fixed Speed Drive M= Optional Forward Curve Fan, Fixed Speed Drive Digit 2 & 3, Drive Selection Contact Daikin Applied with model and serial number information in order to identify the needed part(s). Digit 4, Fan Discharge = Code 06 equals, or 2 2= Code 06 equals 2, or 4 3= Code 06 equals 3, or 6 4= Code 06 equals 4, or 8 Code 4= Lubrication Lines & Insulation = Standard Lube lines ", 3/4# Insulation 2= Standard Lube lines No Insulation 3= Standard Lube lines ", /2# Insulation 4= Standard Lube lines ", 3# Insulation 5= Copper Lube Lines ", 3/4# Insulation 6= Copper Lube lines No Insulation 7= Copper Lube Lines ", /2# Insulation 8= Copper Lube lines ", 3# Insulation Code 5= Not A Central Station Air Handler Code Code 08= Motor Size A=.25 HP F=.5 HP L= 0.0 HP Q= 40.0 HP B=.33 HP G= 2.0 HP M= 5.0 HP R= 50.0 HP C=.50 HP H= 3.0 HP N= 20.0 HP S= 60.0 HP D=.75 HP J= 5.0 HP O= 25.0 HP T= 75.0 HP E=.0 HP K= 7.5 HP P= 30.0 HP Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 6

Unit Code Index, Continued Code 6= Accessory Arrangement Digit, Accessory Section Code 04= H*** or I*** A= Filter Section Only B, C, D= Filter Section and or Mixing Box with Dampers E, F, G= Filter Section and or Mixing Box without Dampers Digit, Accessory Section Code 04= V*** H, K, M= Base Mounted Filter Section and or Mixing Box with Dampers J, L, N= Base Mounted Filter Section and or Mixing Box without Dampers Digit 2, Filter Section 0= No Filters = Flat Filters End Removal 2= Flat Filters Right Side or Bottom Removal 3= Flat Filters Left Side or Top Removal 4= Angular Filters 5= Heavy Duty Angular Filters Digit 3, Filter Type 0= None = Throwaway 2= Cleanable Low Velocity 3= Cleanable High Velocity 4= Throwaway, 35% Pleated Code 7= Auxiliary Coil Section S= Small Coil L= Large Coil Code 8= Auxiliary Coil Type and Rows For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYY XXXXXXXXXX= Special Coil Code 9= Auxiliary Coil Connection Location D= Drive End E= Opposite Drive End Code 20= Standard Coil Section, st Coil S= Small Coil L= Large Coil E= Extra Large Coil Code 2= Coil Types and Rows, st Coil For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYYYYYYY XXXXXXXXXXXXXXX= Special Coil Code 23= Standard Coil Section, 2nd Coil S= Small Coil L= Large Coil E= Extra Large Coil Code 24= Coil Types and Rows, 2nd Coil For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYYYYYYY XXXXXXXXXXXXXXX= Special Coil Code 25= Coil Connection Location, 2nd Coil D= Drive End E= Opposite Drive End Code 26= Standard Coil Section, 3rd Coil S= Small Coil L= Large Coil E= Extra Large Coil Code 27= Coil Types and Rows, 3rd Coil For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYYYYYYY XXXXXXXXXXXXXXX= Special Coil Code 28= Coil Connection Location, 3rd Coil D= Drive End E= Opposite Drive End Code 29= Optional Features A= Gasketed Damper Blades on Mixing Box & Bypass Dampers B= Outdoor Construction with Weatherhood C= Flex Connector on Blower Intake F= Stainless Steel Drain Pan Liner K= Insulated Mixing Box L= Items A & F M= Enclosed Belt Guard N= Insulated Filter Section P= High Static Fan Wheel Q= 6 ga. Minimum Panel Unit Construction W= Outdoor Construction less Weatherhood X= Special Code 22= Coil Connection Location, st Coil D= Drive End E= Opposite Drive End Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 7

Unit Code Index, Continued Code 30= Plug-In Door (Blower Section) Digit, Access Door Location = Top, Opposite Drive End 2= Side, Opposite Drive End X= Special Digit 2, Access Door Dimensions A= 8" x 9" B= 2" x 24" C= 8" x 24" X= Special Code 3= Plug-In Door (Coil Section) Y 6C= 8" x 24" 7C= 8" x 24" XX= Special Code 32= Miscellaneous X= Special Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 8

Coil Notes & Sample Contractor Coil Code Strings Coil Notes Note: ALL Central Station Air Handlers use "Contractor" style coils. Contractor Coils are ordered as SEPARATE LINE ITEMS on the GO/General Order (Example: 976230-07), so they DO NOT have standard nine digit Daikin Applied part numbers. When a replacement Contractor Coil is required a Contractor Coil Quote needs to be prepared. To quote a replacement Contractor Coil it is necessary to obtain model and serial number information from the unit nameplate and then contact Daikin Applied. If the unit has more than one coil it will be necessary to confirm which coil(s) are needed BEFORE quoting. Note that the sample code strings shown below are incomplete and DO NOT furnish enough information to correctly quote a Contractor Coil. GO and/or serial number information is required in order to properly quote a Contractor Coil. In some instances, coils were manufactured separately from the unit and may have a unique serial number such as 9Z2345-00. A coil with a serial number starting with a "9" was built in Scottsboro AL and may or may not have been installed in a unit before shipment. Sample Contractor Coil Code Strings Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 9

Fan Section Assembly Diagram 2 3 4 5 Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 0

Fan Section Components Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 37C 4C 50C 64C 72C N/S MOTOR N/S BELT N/S SHEAVES N/S BUSHINGS Note: Each Airfoil Fan has () CW Wheel and () CCW Wheel BLOWER WHEEL, AIRFOIL, NO. 27, CW 06654320 BLOWER WHEEL, AIRFOIL, NO. 30, CW 066543203 BLOWER WHEEL, AIRFOIL, NO. 33, CW 066543205 BLOWER WHEEL, AIRFOIL, NO. 36, CW 066543207 2 BLOWER WHEEL, AIRFOIL, NO. 27, CCW 066543202 2 BLOWER WHEEL, AIRFOIL, NO. 30, CCW 066543204 2 BLOWER WHEEL, AIRFOIL, NO. 33, CCW 066543206 2 BLOWER WHEEL, AIRFOIL, NO. 36, CCW 066543208 3 BLOWER HOUSING UNITS WITH INLET VANES 03554360 3 BLOWER HOUSING UNITS WITH INLET VANES 035543602 3 BLOWER HOUSING UNITS WITH INLET VANES 035543603 3 BLOWER HOUSING UNITS WITH INLET VANES 035543604 3 BLOWER HOUSING UNITS WITHOUT INLET VANES 0363340 3 BLOWER HOUSING UNITS WITHOUT INLET VANES 03633402 3 BLOWER HOUSING UNITS WITHOUT INLET VANES 03633403 3 BLOWER HOUSING UNITS WITHOUT INLET VANES 03633404 4 DRIVE SHAFT, 2-3/6 DIA. 53.8"L 03528790 4 DRIVE SHAFT, 2-7/6 DIA. 57.88"L 0337290 4 DRIVE SHAFT, 2-7/6 DIA. 62.00"L 03258630 4 DRIVE SHAFT, 2-/6 DIA. 67.2"L 034270500 5 PILLOW BLOCK BEARING, 2-3/6" BORE 020648606 2 5 PILLOW BLOCK BEARING, 2-7/6" BORE 020648607 2 2 5 PILLOW BLOCK BEARING, 2-/6" BORE 020648608 2 2 N/S INLET VANE ASS'Y., NO. 27, CW 2 032739300 N/S INLET VANE ASS'Y., NO. 30, CW 2 032739400 N/S INLET VANE ASS'Y., NO. 33, CW 2 032739500 N/S INLET VANE ASS'Y., NO. 36, CW 2 032739600 N/S INLET VANE ASS'Y., NO. 27, CCW 2 032738700 N/S INLET VANE ASS'Y., NO. 30, CCW 2 032738800 N/S INLET VANE ASS'Y., NO. 33, CCW 2 032738900 N/S INLET VANE ASS'Y., NO. 36, CCW 2 032739000 Part numbers ordered per Code Item on original G.O. Contact Daikin Applied with model and serial number information so the needed part(s) can be correctly identified. 2 Part of housing assembly 0355436( ). N/S= Not Shown Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page

Variable Inlet Vanes Diagram & Assemblies HORIZONTAL DISCHARGE SHOWN (Upblast Discharge slightly different in arrangement.) A VIEW A-A (One side only shown) 9 8 0 6 2 7 A Description Part Number Unit Sizes - Pieces Per Unit 37C 4C 50C 64C 72C HORIZONTAL DISCHARGE 27" FAN 03528590 30" FAN 035285902 33" FAN 035285903 36" FAN 035285904 UPBLAST DISCHARGE 27" FAN 03528600 30" FAN 035286002 33" FAN 035286003 36" FAN 035286004 Assemblies include: Rods, Shafts, Bearings, Hardware & Miscellaneous Parts. For individual linkage parts, see Variable Inlet Vane Components listing. Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 2

Variable Inlet Vanes Components Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 37C 4C 50C 64C 72C SHAFT-LEFT VANE LINKAGE TO RIGHT VANE LINKAGE 6 SHAFT WELD ASSEMBLY 27" FAN 035287800 6 SHAFT WELD ASSEMBLY 30" FAN 03373200 6 SHAFT WELD ASSEMBLY 33" FAN 035547800 6 SHAFT WELD ASSEMBLY 36" FAN 035282400 LINKAGE ROD-VANE TO SHAFT BELL ARM 7.50" DIAMETER, 27.45" LONG 27" HORIZONTAL FAN 03528804 2 7.50" DIAMETER, 29.45" LONG 27" UPBLAST FAN 03528805 2 7.50" DIAMETER, 34.38" LONG 30" FAN 03528803 2 7.50" DIAMETER, 42.50" LONG 33" FAN 0352880 2 7.50" DIAMETER, 47.38" LONG 36" FAN 03528802 2 2 8 FLANGE BEARING,.00" BORE DIAMETER 02064930 2 2 2 2 2 9 BEARING BRACKET 03528300 2 2 2 2 2 0 BELL ARM 028370000 BALL JOINT, FEMALE 0276700 2 2 2 2 2 2 BALL JOINT, MALE 02767000 2 2 2 2 2 Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 3

Low Leak Dampers Diagram & Assemblies 7 6 23 2 20 9 22 8 6 5 7 Damper Assemblies Bub. No. Description Part Number Unit Size 37C 4C 50C 64C 72C 5 Low Leak Damper Assembly 3 7/8" x 2 3/8" 0485450 5 Low Leak Damper Assembly 39 5/8" x 2 3/8" 04854500 5 Low Leak Damper Assembly 47 5/8" x 2 3/8" 04854570 Note: NO Damper Actuators, Actuator Linkage, sensors, OR controls were supplied with Central Station Air Handler units. If a field supplied item is required, contact Daikin Applied with vendor and vendor part number information to see if a suitable replacement can be obtained. Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 4

Low Leak Dampers Components Bub. No. Description Part Number Qty. for Unit Size 37C 4C 50C 64C 72C 6 Damper Blade (Less Gasket) 047793302 4 5 5 6 6 7 Damper Blade Center Support 04779240 Damper Blade Center Support 04854540 Damper Blade Center Support 04854600 5 Damper Blade Gasket Gasket ordered by the foot as required 029870900 - - - - - 6 Driven Damper Blade End Plug Assy. RH 04496208 7 Driven Damper Blade End Plug Assy. LH 04496209 8 Non Driven Damper End Plug RH 04003508 3 4 4 5 5 9 Non Driven Damper End Plug LH 04003509 3 4 4 5 5 20 Nylon Damper Blade Bushing 043730400 6 8 8 0 0 2 Nylon Damper Blade Drive Shaft Bushing 043734000 4 4 4 4 4 22 Nylon Linkage Bar Bushing 046098300 8 0 0 2 2 23 0.50" Locking Collar 0495902 2 2 2 2 2 Air Handler; LSL, MSL, MMM, etc. 37-72, Vintage C Rev. D 0/5 RPL 552227 / Page 5