FBK-FRCA. Return Line Filters Low Pressure Filters In-Line up to 10 bar. Mix&Match to Get What You Need

Similar documents
FPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

Return Line Filters. Section Index

In-Line Filters. Section Index. High FPK

HMK05/25 DURAMAX Spin-Ons

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

Low Pressure Medium Pressure High Pressure Accessories Off-line Filtration

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Low Pressure Filters

Medium Pressure Filters

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

D e s c r i p t i o n

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

FPK04 Max Flow: 100 gpm (379 lpm)

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

10 Hydraulic Filters

Medium Pressure Filters

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTERS & ELEMENTS

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

10 Hydraulic Filters

Taking Hydraulic System Reliability To A Higher Level

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

HPK04 Max Flow: 120 gpm (454 lpm)

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FPK02 In-Line Cartridge Filters

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

MPF filters within this range are suitable for flow rates up to 750 l/min.

THE IMPORTANCE OF AN EFFICIENT FILTRATION

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

12AT/50AT Series Spin-On Filters

Fluid Cooling Industrial COLW Series

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

12CS/50CS Series. Coreless Spin-on Filters

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

12CS/50CS Series Coreless Medium Pressure Filters

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

D e s c r i p t i o n

Pressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters

HIGH PRESSURE FILTERS Series HF2P

LMP series

In line high pressure filters. HF HF 761 series

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

(Ecological Pressure Filter)

Off-Line Filtration OFF-LINE FILTRATION

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A

Flow rates to 500 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

MATERIALS FILTER PRESSURE VALUES

Pictorial Index Hydraulic Filters

Duplex Pressure Filters

FHA 051 Working pressure 6000 psi

FILTER ELEMENTS. Overview of Elements PN# / / FIL

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

Replacement cartridge filter

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

Filtration - Index FILTRATION

7000 Series High Pressure Filters

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

MEDIUM PRESSURE FILTERS

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Low & High Pressure ProGuard Filters

Series RFL In-Line Filter

FCL Filter Cart Flow rate up to 22 gpm (82 lpm)

MPH Maximum pressure 10 bar F l o w r a t e s t o l / m i n

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Stainless Steel Pressure Filters

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

HIGH PRESSURE FILTERS

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

Bulk Liquid Filtration

Transcription:

Return Line Filters Low Pressure Filters In-Line up to 10 bar Mix&Match to Get What You Need Donaldson's Mix&Match system provides the great performance and functional advantages of custom-engineered filters with the convenience and speedy delivery of in-stock parts. Choose your options and build a filter model that exactly suits your cleanliness requirements. Technical Data Filter Elements Operating pressure up to 1000 kpa (10 bar). Static pressure testing up to 1500 kpa (15 bar). By-pass valve setting 150 kpa (1,5 bar) or 170 kpa (1,7 bar) per ISO 3968. Operating temperature -20 +120 C. Compatibility with hydraulic fluids per ISO 2943. Flow rate and pressure drop determined per ISO 3968 with oil kinematic viscosity 30 cst at 40 C and density 0,875 kg/dm ³. Operating pressure up to 1000 kpa (10 bar). Static pressure testing up to 1500 kpa (15 bar). Collapse resistance 1000 kpa (10 bar) per ISO 2941. Wire mesh: 60 micron. Cellulose media: 36-50 micron, reinforced with wire mesh. Synteq synthetic media: 11-23 micron. Hydraulic Filters & Accessories 63

Components WIRE MESH MEDIA CELLULOSE MEDIA SYNTHETIC MEDIA /6 /3 /1 /03 XP10 60 m ß 50 m(c) 1000 ß 36 m(c) 1000 ß 23 m(c) 1000 ß 11 m(c) 1000 CARTRIDGE CODE Family RMF RMF RMF RMF RMF 60 60 P171607 60 P171606 50 P550268 40 P171604 40 P171602 80 80 P171612 70 P171611 60 P171610 50 P171609 50 P171608 108 100 P764638 118 100 P763987 160 160 P171617 150 P171616 140 P550148 120 P171614 120 P171613 200 200 P171622 190 P171621 160 P171620 140 P171619 140 P171618 380 380 P171617 340 P171616 300 P550148 280 P171614 280 P171613 400 400 P171622 360 P171621 320 P171620 300 P171619 300 P171618 220 200 P764410 150 P764411 250 230 P764409 170 P763668 CA60 CA80 CA108 CA108 CA160 CA200 CA160 CA200 CA220 CA250 RMF = Recommended Maximum Flow in liters/minute with use of standard head. BPV = Bypass Valve Setting. s Choices for Size 60/80 160/200 220/250 380/400 Part Ports Bypass Valve Setting Drilled holes for indicator Side Indicator Info Indicator to use Snout Mounting holes P563279 1 1/16 SAE 1 bar no - none 1-12 UNF 1/4-20 UNC P563287 1 1/16 SAE 1 bar no - none 1-12 UNF M6 P563280 1 1/16 SAE 1,7 bar plugged left + right P563297,P563298,P563978 or P563296 1-12 UNF 1/4-20 UNC P561141 1 1/16 SAE 1,7 bar no - none 1-12 UNF 1/4-20 UNC P765539 1 1/16 SAE 2,5 bar no - none G3/4 M8 P562261 1/2-14 NPTF no opening no - none 1-14 UNS 1/4-20 UNC P562262 7/8-14 UNF no opening no - none 1-14 UNS 1/4-20 UNC P175017 G3/4 1,7 bar plugged left + right P171954, P171958, P171966 or P173104 G3/4 M8 P173441* G3/4 1,7 bar no - none G3/4 M8 P765584 G3/4 no opening used left P162696 (installed) G3/4 M8 P764407 G1 1/4 1,5 bar plugged left P162400 or P163839 G1 1/4 M8 P761314 G1 1/4 1,5 bar plugged top P171954, P171958, P171966 or P173104 G1 1/4 M8 P762638 G1 1/4 1,5 bar plugged right P171954, P171958, P171966 or P173104 G1 1/4 M8 P176846* G1 1/4 1,5 bar no - none G1 1/4 M8 P765583 G1 1/4 no opening used left P162696 (installed) G1 1/4 M8 P760071 G1 1/4 1,5 bar drilled, not plugged top P171961, P171963 or P171950 G1 1/4 M8 P764408 G1 1/4 1,5 bar drilled, not plugged left P162696 G1 1/4 M8 P762641 G1 1/4 3 bar no - none G1 1/4 M8 P176965 G1 1/4 no opening plugged left + right - G1 1/4 M8 P173403 G1 1/4 no opening plugged left + right P171954, P171958, P171966 or P173104 G1 1/4 M8 P765639 G1 1/4 no opening drilled, not plugged left P162696 G1 1/4 M8 P764414 G1 1/4 1,5 bar drilled, not plugged left P162400 or P163839 1 1/2-16 UN M8 P764413 G1 1/4 1,5 bar plugged top P171954, P171958, P171966 or P173104 1 1/2-16 UN M8 P764412* G1 1/4 1,5 bar no - none 1 1/2-16 UN M8 P764415 G1 1/4 1,5 bar drilled, not plugged left P162696 1 1/2-16 UN M8 P764421 G1 1/4 no opening plugged right P171954, P171958, P171966 or P173104 1 1/2-16 UN M8 P761264 G1 1/2 1,7 bar drilled, not plugged front P171961, P171963 or P171950 G1 1/4 M10 P766293* G1 1/2 1,7 bar no - none G1 1/4 M10 FBK Filters aren't delivered with drilled holes for indicators or bypass valve, heads are. Unless otherwise mentioned, the usage of indicators is mandatory, because the drilled holes for indicators are not plugged. * Standard 64 Hydraulic Filters & Accessories

Standard HEAD DIMENSIONS A B C D E F G S BPV mm mm mm mm mm mm bar P173441 G3/4 95 13 41,5 M8 38 20 1,7 NA P176846 G1 1/4 132 28,5 61,5 M8 50 24 1,5 P766293 G1 1/2 138 35 70 M10 65 24 1,5 P764412 G1 1/4 132 28,5 61,5 M8 50 25 1,5 SPIN-ON DIMENSIONS X Y Z mm mm 146 96 G3/4 209 96 G3/4 183 108 M40x2 230 108 M40x2 181 128 G1 1/4 226 128 G1 1/4 181 128 G1 1/4 226 128 G1 1/4 236 136 1 1/2-16UN 306 136 1 1/2-16UN LEFT 60/80 RIGHT LEFT 160/200 RIGHT LEFT 220/250 RIGHT FRONT 380/400 Hydraulic Filters & Accessories 65

Indicator Choices Indicator Kind Reference Drawing Setting (bar) Contact Protection Class Cable Clamp Max. Values P171961 Electrical Differential A 1,4 Normally Open/Closed IP65 PG11 30 Vcc/Ac; 0,5 A res. and 0,2 A ind. P171963 Electrical Differential A 1,4 Normally Open/Closed IP65 PG11 30 Vcc/Ac; 0,5 A res. and 0,2 A ind. P162400 Electrical Differential B 1,25 Normally Open 6-30 V DC; 200 ma P163839 Electrical Differential B 1,25 Normally Closed 6-30 V DC; 200 ma P171966 Electrical Differential C 1,2 Normally Open IP65 PG7 48 V; 0,5 A res. and 0,2 A ind. P173104 Electrical Differential C 1,2 Normally Closed IP65 PG7 48 V; 0,5 A res. and 0,2 A ind. P162696 Visual Differential D 1,7 P171950 Visual Differential E 1,4 P171958 Visual Differential F 1,2 P171954 Visual Vacuum G -1/3 Installation & Service Guidelines P763996 P175055 C, D, F or G A, B, C, D, E, F or G Important 60/80 The filter head snout must be lubricated before spinning on a new filter to 160/200 prevent thread damage. Heavyweight gear lube is recommended. Oil the O-Rings before assembly. P175055 P763462 B, C, D, F or G A or E P175055 220/250 380/400 66 Hydraulic Filters & Accessories

Performance Curves Hydraulic Filters & Accessories 67

68 Hydraulic Filters & Accessories