RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

Similar documents
TVS/R FAN COIL UNITS HI-RISE, VERTICAL

FS Fan-Coil Units Hi-Rise, Vertical

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

Submittal 6 [152] 6 [152] 8 [203]

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

Submittal. Front View Side View

FN Fan-Coil Units High-Performance, Horizontal

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

FH Fan-Coil Units Low-Profile, Horizontal

RAH Engineering Guide

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

FCVC Series VERTICAL FAN COILS

RBV Engineering Guide

Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View.

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Vertical Hi-Rise Fan Coil Unit (Model FS)

SDL Single-Duct, Low-Height, VAV Terminals

Vertical Stack Fan Coils 300-1,200 CFM

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

TSS Single-Duct VAV Terminals

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Hi-Performance Series Fan Coil Technical Catalog

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Horizontal Series Fan Coil Technical Catalog

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

Complete HVAC Capability

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

HOW TO SPECIFY SDV UNITS

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Horizontal Fan Coils 200-1,200 CFM

FAN POWERED TERMINAL UNITS

BUILD YOUR REPUTATION ON OURS. Horizontal Series FAN COIL TECHNICAL CATALOG

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

SECTION AIR TERMINAL UNITS

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

CHP

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

catalog SDL Single-Duct, Low-Height, VAV Terminals

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

ELITE SERIES R-410A Ready - Multi-Position

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

SINGLE PACKAGE HEAT PUMPS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES


TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

FDCLP2 Constant Volume Series Flow, Low Profile

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Direct Gas-Fired Heating

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Typical Applications. Horizontal Installation

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

R-22, 13 SEER 60 Hertz

August PRODUCT DESIGN GUIDE Inteli-line Vertical Stack Fan Coil with Slide-Out Chassis

Climas y Proyectos Leyco, S.A. de C.V.

D M S 760 C01 A A 1 1

DESCRIPTION FEATURES

catalog SDL Single-Duct, Low-Height, VAV Terminals

FAN POWERED TERMINAL UNITS

MQL TABLE OF CONTENTS

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

Dual Duct Variable Air Volume Terminal (Model TDS)

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Modular Variable Speed Air Handlers

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

BHH Product Specifications

ELITE Series R-410A - Upflow / Horizontal

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

Factory Option Codes L M E S P R D V F F H E

FORM NO. HSC-543 AIR HANDLERS

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

SINGLE DUCT TERMINAL UNITS

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

IAQ. ROUND DUCT RETROFIT Model ARR

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Transcription:

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com

RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model RAV Concealed Dimensional Data Dimensions Unit Size Single / Double Supply A B C D E 03 & 04 18 [457] 16½ [419] 16 [406] 8 [203] 6 [152] 06 & 08 20 [508] 18½ [470] 18 [457] 12 [305] 6 [152] 10 & 12 24 [610] 22½ [572] 22 [559] 14 [356] 8 [203] Notes: 1. All dimensions are inches [mm] and are +/- ¼ [6mm]. Metric values are soft conversions. 2. Tile ring is installed on front of unit as shown, and may be moved to left or right side of unit in field. Tile ring omitted on units with ADA control-mounting location. 3. Wiring from electrical-entry point to control enclosure is furnished and installed by others in field 4. Risers available from 3/4 [19mm] to 3 [76 mm] diameter with 1/2 [13 mm] thick insulation, and 3/4 [19mm] to 2-1/2 [64 mm] diameter with 3/4 [19 mm] thick insulation 5. Riser length is 120 [3078 mm] max, 100 [2540 mm] min 6. Back riser location shown. See arrangement drawings for available unit configurations. 7. Factory-mounted risers shown. Risers may also ship in advance of the unit. See ship-inadvance riser drawings for details. 02 Note: All data and dimensions are subject to change without notice. Contact your Superior Rex representative for current submittal drawings. Drawings are not to scale and are not for installation purposes.

RAV Series: RAISING THE STANDARD IN FLEXIBILITY AND PERFORMANCE Owners AHRI Standard 440-certification ensures exacting performance. The RAV fan coil unit s 3-speed, direct-drive motor allows optimized cabinet airflow and sound performance. Enhanced sound levels are achieved through an electronic fan speed controller (SCR) which allows further motor speed fine tuning. RAV fan coil units are constructed of galvanized steel, surpassing the ASTM 125-hour, salt-spray test for corrosion and rust. Decorator front panels, supply grilles, and exposed- cabinet model RAVE feature durable, powder-coat paint that resists fading, scratches and fingerprints. Models RAVM/RAVL tandem units ship complete with risers enclosed in a wall plenum with one layer of 5/8 gypsum for sound attenuation. Units may be ordered with two layers of gypsum and fire-blocking material for a one-hour fire rating per UL 1479. (CFM) Unit Size RAV Fan Coil Airflow Nominal 03 350 04 450 06 600 08 800 10 1000 12 1200 Actual performance may vary based on model, options and operating conditions. Ask your Superior Rex representative for complete performance information. SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Concerned about Indoor Air Quality? Sloped drain pans are standard on RAV fan coils. The coils are easily removed for cleaning. As an option, field removable drain pans may be supplied. Optional stainless-steel drain pans and coil casings are available. IAQ lining options include foil-faced or elastomeric, closed-cell-foam insulation. Designers The RAV unit s impressive list of standard features provides unparalleled design flexibility. Riser slot knockouts are included on the left, right and back panels. Supply air opening knockouts are included on all sides, as well as the top of the unit. Outside air can be introduced with manual or motorized dampers. Coil options allow for three or four-row chilled water and one or tworow hot water coils in the reheat position. A total of five rows of coil are accommodated. Factory-Mounted Control Packages A wide variety of control options and thermostats are offered. Factory-mounting and wiring of DDC controls by others is also available. Silent Relays Silent, solid state relays are available for fan and electric heat control in sound-sensitive environments. Contractors RAV fan coil units provide maximum performance while reducing installed cost to the contractor. Motor wiring is brought to a control compartment on the inside of the unit, reducing electrical hook-up time. Internal stainless steel-braided hoses allow easy field configuration of riser connections without the need for thermal cutting and joining of piping. Risers may ship in advance of the unit to facilitate installation and fire-safing of floor penetrations in limited space. Additionally, fan coil units are protected from construction debris during installation and pressure testing of the risers. Factory-Furnished Valve Packages Valve packages provided by the factory ensure proper fit, operation and performance. Electric Heat A variety of kw and voltage configurations are available. Options include door-interlock disconnects, low-voltage controls, and silent solidstate relays. All control and electric heat configurations include single point-power connection and are cetl-listed as an assembly. 03

SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Coils and Piping All units are available in 2-pipe or 4-pipe configurations. The heating coil is standard in the reheat position. Access for cleaning on both the entering and leaving-air sides is available. Coils are removable from the front of the unit for service. Fan Deck For ease of service, the fan/motor assembly is easily removed by unscrewing two locknuts located at the front of the assembly. Slide rails support the fan during removal and installation, and the electrical harness is equipped with a quick-connect plug. Risers Risers, coils and piping packages are pressure-tested and ship installed on the unit as a complete package. Risers may also ship in advance of the unit. This option greatly simplifies installation, while keeping the units free of construction debris during pressure testing of the risers. Filters Filter options include 1 throwaway (standard), pleated MERV 8, or synthetic media. Filters are easily replaceable from the return air section when the front panel is removed. Drain Pan The sloped, insulated drain pan is available in stainless steel construction. Standard drain pans are externally insulated, single-wall, galvanized steel. As an option, the RAV drain pan can be equipped for easy removal from the front of the unit for inspection and cleaning. For optimum moisture resistance and cleanability, the unit may be lined with foilfaced fiberglass insulation (shown above) or elastomeric, closed-cell-foam insulation. Control Enclosure The hinged access door allows entry to a spacious electrical compartment. The compartment houses all electric heat and control components. Terminal strips are furnished for simple power wiring and control wiring connections. 04

SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Stainless Steel Braided Hoses Standard on all 1/2 2-pipe and 4-pipe systems, stainless steel braided hose kits allow for flexibility and thermal expansion within the unit cabinet. The hose-to-coil and hose-to-riser connections are made via a threaded swivel adapter, simplifying coil removal. For more information, see the RAV Hose Kit sales guide at www.superiorrex.com. Field Configurations Supply air opening knockouts are included on all sides, and the top, of the RAV unit. Riser-slot knockouts are included on both sides, as well as the back panels. If requested, the unit ships from the factory with knockouts removed for the selected arrangement of supply air and riser location. Powder-Coated Painted Surface Exposed cabinet model RAVE, as well as the front-return, textured, decorator panel, feature a powder-coat finish that resists scuffing, scratching, fading, and fingerprints. 05

SO TOUGH, WE GUARANTEE IT! www.superiorrex.com RAV Series: FAN COIL UNIT FEATURES Standard Features: Construction AHRI Standard 440-certified and labeled Galvanized-steel construction ½ thick fiberglass insulation Integral filter rack with 1 throwaway filter Riser-slot knockouts Supply-air knockouts Decorator Front Panel Stamped louver return-air grille Durable, powder-coat paint Quarter-turn, cam-lock fasteners Supply Air Single outlet Front, side or top outlets Electrical Heat ETL-Listed as an assembly for safety compliance Integral electric heat assembly with removable elements for easy service Automatic reset primary and back-up secondary thermal limits Single point power connection Optional Features: Construction Master/drone arrangements Foil-faced fiberglass insulation Elastomeric, closed-cell-foam insulation 1 pleated filter (MERV 8) Synthetic media Manual or motorized outside-air damper Blower shield Coils Cooling: 3 or 4-row chilled water Heating: 1 or 2-row hot water - reheat position 5 total rows of cooling and heating coils maximum ½ O.D. seamless copper tubes 0.016 tube wall thickness High-efficiency, aluminum fin surface for optimizing heat transfer, pressure drop and carryover Easily removable for service Manual air vents Drain Pans Single wall, galvanized steel, externally insulated - fire retardant and anti-microbial Positively sloped to drain connection 7/8 O.D. drain connection P-trap is factory installed Fan Assemblies Forward-curved, DWDI, centrifugal type blowers 115-volt, single-phase, three-tap PSC motors Quick disconnect motor connections Easily removable fan/motor for service Electrical cetl-listed for safety compliance Electrical enclosure with access door for field-wiring terminations Terminal block for field connections Decorator Front Panel Recessing frame Full-faced aluminum grille Supply Air Double deflection discharge grille(s) Double outlets Sight and sound baffles for double outlet units Opposed blade damper Coils Automatic air vents Stainless steel coil casings Drain Pans Stainless steel construction with external insulation Removable for cleaning Fan Assemblies 208-230 & 277 volt, single-phase, three-tap PSC motors 115, 208-230 & 277 volt, ECM 3 speed motors 06

RAV Series: FAN COIL UNIT FEATURES Electrical SCR fan speed controller Fan relay packages Silent, solid state fan relays Toggle disconnect switch Condensate overflow switch (drain pan) Main fusing Unit and remote mounted three speed fan switches SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Electric Heat Manual-reset, secondary thermal limit Silent relay/contactors Door interlocking disconnect switches Main fusing Piping Packages Factory assembled and installed ½, 2-way and 3-way, normally closed, two-position electric motorized valves Stainless steel braided hoses (threaded swivel connections) for thermal expansion, including isolation ball valves with memory stop Fixed and adjustable-flow control devices P/T ports and Y-strainers Modulating control valves High-pressure, close-off actuators (50 PSIG max) Thermostats Analog, digital display, or programmable Unit mounted and wall mounted 2-pipe and 4-pipe control sequences Automatic and manual changeover Integral, three-speed, fan switches ADA mounting location on front panel or unit sides Risers Type-M or Type-L copper with swaged connections ¾ to 3 diameters ½ and ¾ closed-cell insulation Type-M copper condensate riser Riser extensions Riser cover Ship in advance risers 07

Superior Rex 605 Shiloh Road Plano Texas 75074 (ofc): 972.212.4800 (fax): 972.212.4884 SO TOUGH, WE GUARANTEE IT! www.superiorrex.com