1 of 5 Risk of electrical shock. Disconnect power before servicing or installing luminaire. Risk of injury or damage. Luminaire will fail if not installed properly. Follow installation instructions. Risk of injury. Wear safety glasses and gloves during installation and servicing. Allow ample time to cool before handling. IMPORTANT SAFETY INSTRUCTIONS Read all installation instructions before installing. It is important to save these instructions. Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power on, could damage the LEDs and is not covered by warranty. Connectors on modules and approved housings are keyed for specific voltage combinations; do not force or attempt to bypass connectors. Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module, warnings of installation near combustible materials and/or insulation. Turn off power at circuit breaker before attempting to install or perform maintenance on the fixtures. Be sure to connect ground wire to prevent electric shock or other potential hazards. The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local codes by a person familiar with the construction and operation of the product and the hazards involved. Do not block the trim aperture as this may cause unsafe operating conditions. WARNING: RISK OF FIRE. Non-IC fixture requires that insulation must be kept at least 3 away from all sides of the fixture. Minimum of 90 C supply conductors. Consult a qualified electrician before installation. WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a violation of N.E.C 110-3(B) and voids all warranties. CEILING CUT OUT: 1. Cut out ceiling hole according to size: -- Round: 4 1/8 (105mm) diameter -- Square: 4 1/16 x 4 1/16 (103mm x 103mm) Note: Oversized holes will not allow fixture and/or trim to fit correctly. 1 REMOVE COVER PLATE: 1. Remove (2) M3 pan head screws and junction box cover plate. 2. Remove knockout on cover plate and attach conduit or Romex cable. 2 4 1/8 [105mm] 4 1/16 [103mm] Cover Plate M3 x 5mm pan head ELECTRICAL CONNECTIONS: 3 1. Connect ground from fixture to green (GROUND) supply wire, black wire from fixture to black (HOT) supply wire and white wire from fixture to white (NEUTRAL) supply wire. Use UL listed connectors or wire nuts to make the connections (provided by others). Connect dimming wires if applicable, see page 5. 2. Replace cover plate and (2) M3 pan head screws. INSTALL HOUSING: 1. Make sure swing out lugs are in a closed position. 2. Insert driver housing through ceiling opening. 3. Rest the driver housing in the ceiling plenum. 4. Push remodel assembly into ceiling opening. 4 LED Module Ceiling opening Black Red Hot Neutral Ground 120V / 277V connection wires Driver housing Swing out lugs Junction box INSTRUCTIONS L/M-09202017 P-1
2 of 5 REMODEL ASSEMBLY INSTALLATION: 5 Use a #1 screwdriver to tighten the (3) swing out lugs into open position (Do not overtighten). Note: Ceiling thickness must be between 5/16 [8mm] and 3/4 [19mm]. MODULE INSTALLATION: 1. Check that power is off at breaker, hot plugging may damage LEDs. 2. Connect female quick connect from housing to male quick connect on module. 3. Snap module into channel and confirm module sits parallel to ceiling line and is securely fastened into housing. 6 (3) M3 x 25mm Quick connect Channel Swing out lug ADJUSTING HORIZONTAL ADJUSTMENT: 1. Loosen fastener with a #1 screwdriver to allow fixture to adjust 359º horizontally. 2. Place screwdriver in adjustment assist to rotate module to desired horizontal position. 3. Tighten fastener to lock horizontal adjustment. 7 TRIM INSTALLATION: 1. Position trim alignment label to trim location tab in the fixture. 2. Snap trim into fixture. 8 Trim location tab M3 x 6mm fastener Trim alignment label INSTRUCTIONS L/M-09202017 P-2
3 of 5 ACCESSORY HOLDER: 1. Rotate release cap by turning counter clockwise. 2. Install accessories into accessory holder and replace accessory holder s retaining clip. 3. Place accessory holder and accessory flush against optic and replace release cap. OPTIC REPLACEMENT: 1. Remove trim, then remove module from channel and disconnect quick connect. 2. Rotate release cap by turning counter clockwise. 3. Set cap and retainer ring aside and change optics. 4. Align optic pins to slots in module. Module Module Accessories Accessory holder s retaining clip Accessory holder Optic Retainer ring Optic slots Release cap Release cap REPLACEMENT: 1. Adjust vertical angle to 0º and remove module from channel and disconnect quick connect. 2. Unscrew all three swing out lugs with a #1 screwdriver. Make sure the swing lugs are in the closed position. 3. Remove the remodel assembly and the driver housing will follow. 4. Remove cover plate and slide out driver bracket. 5. Replace new driver on driver bracket and replace module quick connect. 1 2 4 Driver Driver Bracket 5 Driver Housing Module Quick Connect 3 Cover Plate M3 x 5mm pan head 8/32 nuts INSTRUCTIONS L/M-09202017 P-3
Accessories and Options 4 of 5 LED MODULE KIT Example: MXMG2L02712 SERIES WATTAGE CCT / CRI OPTIC MXMG2 (MX G2 Module) L0 (10 Watts) L1 (16 Watts) L2 (20 Watts) L3 (26 Watts) 27 (2700K / 82 CRI) 279 (2700K / 92 CRI) 30 (3000K / 82 CRI) 309 (3000K / 92 CRI) 35 (3500K / 82 CRI) 359 (3500K / 92 CRI) 41 (4100K / 82 CRI) 419 (4100K / 92 CRI) CA35 (Class A 3500K) CW30 (CrispWhite 3000K) 12 (12º Spot) 24 (24º Narrow Flood) 36 (36º Flood) 50 (50º Wide Flood) LED OPTICS Example: IP-OP4724 IP-OP4712 (12º Spot) IP-OP4724 (24º Narrow Flood) IP-OP4736 (36º Flood) IP-OP4750 (50º Wide Flood) ACCESSORY HOLDER Holds two filter media LH47 (Accessory Holder, Black) FILTER MEDIA Requires an accessory holder PFLMB-47 (Hex Louver, Black) PFL4-47 (Solite Lens) PFL2-47 (Linear Spread Lens) PFL1-47 (Prismatic Spread Lens) WET LOCATION KIT Converts downlight trims into wet location trims. SERIES LENS TYPE MXL-RD (Round Downlight) MXL-SD (Square Downlight) MXL-RP (Round Pinhole) MXL-SP (Square Pinhole) -SL (Solite) -CR (Clear Tempered) -FR (Frosted) INSTRUCTIONS L/M-09202017 P-4
Dimming Compatibility 5 of 5 0-10V DIMMING (10% Dimming, eldoled 1%, eldoled 0.1%) --120V/277V and power packs Manufacturer Part Number(s) HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V, PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V, FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV, PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277V Leviton Leviton Centura Fluorescent Control System, IllumaTech IP7 Series, DPSPE-212 Lightolier ZP600FAM120, MP1500FAM120, V2000FAMU Lithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DC Lutron DVTV, NTFTV Synergy ISD BC 120/277 INPUT 0-10V DIMMER VIOLET (+) GREY (-) LUTRON ECOSYSTEM DIMMING --120V or 277V --Dims down to 1% or 5% Product Part Number(s) EcoSystem CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM, EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum ECO SYSTEM CONTROL (BY OTHERS) ECO SYS BUS VIOLET (E1) VIOLET (E2) LUTRON HI-LUME DIMMING --120V or 277V --Dims down to 1% Product Part Number(s) NovaT NTF-10, NTF-103P, NTF-103P-277, NTF-10-277 Nova NF-10, NF-103P, NF-103P-277, NF-10-277 Vareo VF-10 Skylark SF-10P, SF-12P-277, SF-12P-277-3, SF-103P Diva DVF-103, DVF-103P-277, DVSCF-103P, DVSCF-103P-277 Ariadni AYF-103P, AYF-103P-277 Vierti VTF-6AM Maestro MAF-6AM, MAF-6AM-277, MSCF-6AM, MCSF-6AM-277 Maestro Wireless MRF2-F6AN-DV Spacer System SPSF-6A, SPSF-6A-277, SPSF-6AM, SPSF-6AM-277 Lyneo LXF-103PL, LXF-103PL-277 Radio RA 2 RRD-F6AN-DV HomeWorks QS HQRD-F6AN-DV 3-WIRE CONTROL (BY OTHERS) ORANGE ELV DIMMING --120V only --Dims down to 1% MX MODULE DIMS DOWN TO Product Part Number(s) L0 (10W) L1 (16W) L2 (20W) L3 (26W) Leviton IPI06-1LZ - 1% 1% 1% Leviton 6633-P 1% 1% 1% - Lutron DVCL-153P 1% 1% 1% 1% Lutron S600P 3% 1% 2% 2% Cooper DLC03P - 1% 1% 2% Cooper DAL06P - 1% 1% 1% 120V INPUT FROM DIMMER INSTRUCTIONS L/M-09202017 P-5