INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

Similar documents
SITRANS F M flow sensors 711/A and 711/911E

VERSAFLOW MAG 4000 Quick Start

DIN /DIN Aseptic Screwed Union for ISO 1127 Schedule Pipe

SITRANS F M. Flow sensor MAG 1100 F 3/59

DIN /DIN Aseptic Unions for BS 4825/ISO 2037/ASME BPE 2002

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

SITRANS F flowmeters SITRANS F C

DIN /DIN Aseptic Flange Union for DIN 11866/11850 Tube

SITRANS F Coriolis Flowmeters SITRANS FCS400 sensor Quick Start

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Flow Measurement SITRANS F M

Food & beverage. Oil & gas. Water & waste water

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

SITRANS F C. Flow sensor MC2 4/193. Overview

Flow Measurement SITRANS F C

DIN Hygienic Union & Fittings

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

OPTIFLUX 2000 Quick Start

Magnetic Inductive Flow

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

OPTIFLUX 6000 Technical Datasheet

CAUTION The sensor must always be completely filled with process media in order to measure accurately.

Flow Measurement SITRANS F M

Electromagnetic flowmeters

Electromagnetic flowmeters for water and seewage

Installation Operation Maintenance

PNEUMATICALLY ACTUATED 2-WAY

SMS Swedish Standard Union

Compact System NRGS 11-2 NRGS Original Installation Instructions English

SITRANS P measuring instruments for pressure

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

WATERFLUX 3070 Quick Start

Hygienic self-priming GEA Tuchenhagen -VARIFLOW centrifugal pump Series TPS

ELECTROMAGNETIC FLOW METER INSTALLATION MANUAL OF INSERTION SENSORS

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

OPTISWITCH 6500 C Technical Datasheet

DIN EN General

ORIFICE PLATE flow meters

IDF / ISS Hygienic Union BS 4825 Part 4

Magnetic-inductive flow meter for hazardous areas

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

DATA SHEET 1 : 1 CABLE TRAY WITH LOCK. Type No. A 1 A1 1 A2 A3 B 2 B1 2 C D E F

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

485 - NC NO/DA DN

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Liquid filters _ 302. Deaerators. Product Bulletin

TIDALFLUX 2300 F Quick Start

FK DN PVC-U Butterfly valve

VDCI mixproof valve technical description

Flow Measurement SITRANS F C

Dura Water Wafer Butterfly Valve

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Insertion magnetic inductive flowmeter

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level Sensor with G1/2" Thread Hygienic

Proline Promag 10H, 50H, 53H, 55H

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

Level Sensor with M12 Thread Hygienic

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions. 1 Contents 1 Contents 1

Electro-Magnetic Flowmeters Sensors MagMaster MFE

OPERATION AND MAINTENANCE INSTRUCTIONS

Rosemount 485 Annubar Pak-Lok Assembly

2/2-Way and T Valve Bodies in Stainless Steel

Magnetic Inductive Flowmeter EP / UMF2 (B)

ISTEC MAGNETIC METERS

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

Siemens Industrial SITRANS F US SONOFLO. Ultrasonic flowmeter Type SONOKIT hot-tap mounted. Manual, amendment *085R9429*

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

2/2-Way and T Valve Bodies in Stainless Steel

Operating instructions Binary level sensor LMT /00 06/2011

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

Electromagnetic Flowmeters SITRANS F M MAG 1100 sensor

Field IT Electro-Magnetic Flowmeters Sensors

Thermowell For sanitary applications Model TW61, for orbital welding

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

SM4000. Electromagnetic Flowmeter with AC Magnetic Field Excitation Model: SE21_/SE41F. D184B121U02 Rev. 01. Operating Instruction

SITRANS T measuring instruments for temperature

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

Magnetic-Inductive Flow Meter FMI

OPTISWITCH 6500 C Technical Datasheet

Octave Water Meter Installation Manual

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

FK DN PVC-U. Butterfly valve

Hygienic Butterfly Valve VZFA Product range overview

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Industrial Turbo Meters, Sizes 2" through 6"

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Magnetic-Inductive Flow Meter FMQ

Installation, Operation, and Maintenance Manual GENERAL VALVE GENERAL VALVE TRUSEAL / IOM-GEN-TRUSEAL. Installation, Operation, and Maintenance Manual

Transcription:

s INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100 ENGLISH 083R9057 Introduction Siemens Flow Instruments SITRANS F M MAGFLO electromagnetic flowmeters consist of a sensor and a signal converter. These instructions only describe the sensor installation. For further information on the signal converter installation, please refer to the SITRANS F M MAGFLO handbook. 083R9057 Sensor MAG 1100 FOOD MAG 1100 FOOD/6000 and MAG 1100 FOOD/5000, compact and separate DN L A A 1 B B 1 D D i D i Weight 1 ) (Al 2 O 3 ) (PFA) [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg] 10 64 156 309 181 334 64 10 10 2.2 15 64 156 309 181 334 64 15 16 2.2 25 79 164 317 196 349 77.5 25 26 2.7 40 94 176 329 218 371 91 40 38 3.4 50 104 184 337 235 388 119 50 50 4.2 65 131 194 347 254 407 130 65 66 5.5 80 156 200 353 266 419 155 80 81 7.0 100 186 213 366 292 445 183 100 100 10.0 1 ) With signal converter MAG 5000 or MAG 6000 installed weight is increased by approx. 0.8 kg. The MAG 1100 FOOD sensor can also be used with the MAG 2500 or MAG 3000 signal converter. Built-in length DN A L 1 ) [mm] [mm] 10 99 146 15 99 146 25 113 161 40 126 176 50 154 186 65 165 223 80 200 258 100 225 288 1 ) The total built-in length "L" is independent of the adapter type selected. Order no.: FDK:521H0139 SFIDK.PI.026.A3.02

Installation, general Reading and operating the flowmeter is possible under almost any installation conditions because the display can be oriented in relation to the sensor. To ensure optimum flow measurement attention should be paid to the following: The sensor must always be completely full with liquid. Therefore avoid: Installation at the highest point in the pipe system Installation in vertical pipes with free outlet For partially filled pipes or pipes with downward flow and free outlet the flowmeter should be located in a U-tube. Installation in vertical pipes Recommended flow direction: upwards. This minimizes the effect on the measurement of any gas/air bubbles in the liquid. 2 SFIDK.PI.026.A3.02

Installation, general (continued) Installation in horizontal pipes The sensor must be mounted as shown in the upper figure. Do not mount the sensor as shown in the lower figure. This will position the electrodes at the top where there is possibility for air bubbles and at the bottom where there is possibility for mud, sludge, sand etc. If using empty pipe detection, the sensor can be tilted 45, as shown in the upper figure. Measuring abrasive liquids and liquids containing particles Recommended installation is in a vertical/ inclined pipe to minimize the wear and deposits in the sensor. Inlet and outlet conditions To achieve accurate flow measurement it is essential to have straight lengths of inlet and outlet pipes and a certain distance between pumps and valves. It is also important to centre the flowmeter in relation to pipe flanges and gaskets. Potential equalization The sensor must be installed between two adapters. Potential equalization with the liquid occurs automatically via these adapters and through the adjacent pipe. SFIDK.PI.026.A3.02 3

Installation The MAG 1100 FOOD sensor has an integrated clamp connection and is designed for installation between two adapters, which are supplied separately. The adapters are available for a variety of standards according to: ISO, DIN, SS, SMS, BS and DS, for direct welding into dairy pipes or with clamp- or threaded fittings. At assembly the gasket is placed in the adapter. The adapter is then fastened with a clamp ring. The clamp ring must be located, closed and tightened in order to ensure complete metallic contact between sensor and adapter facing. To obtain optimum accuracy and hygienic conditions it is important that the sensor and the pipes are correctly aligned around their centerline, fittings must be perpendicular to the pipeline and upstream pipelines must be straight without curves. Warning Turning the sensor around the adapter centre line after the clamp rings have been fastened will damage the liner. The sensor may therefore only be turned when the clamp rings have either been removed or completely loosened. Installation, welding type adapter The two adapters are welded directly into the dairy pipes. It is important to ensure a perpendicular welding to the pipeline in order to omit misalignment between sensor and adapter facing. Installation to be as follows: 1. Cut a piece of the pipeline equal to the built-in length L stated for the actual sensor dimension. 2. Assemble the sensor and the adapters with the clamp rings - leave the gaskets off. 3. Mount the sensor and tag-weld the adapters to the pipe. 4. Remove clamp rings and dismount the sensor. 5. The adapters are firmly welded to the pipe. 6. Re-install the sensor with gaskets and clamp rings. 4 SFIDK.PI.026.A3.02

Installation, clamp type adapter Sensor, gaskets and adapters are assembled to one unit and then installed in the pipeline prepared with a suitable fitting. Standard gaskets for the actual clamp connection must be used. The clamp rings must be located, closed and tightened. Installation, thread type adapter Sensor, gaskets and adapters are assembled to one unit and then installed in the pipeline prepared with a suitable fitting. Standard gaskets for the actual thread connection must be used. Tightening must be performed with a suitable union spanner. SFIDK.PI.026.A3.02 5

Self-draining For applications where self-draining is required, the sensor must be mounted with a minimum incline of 15 to the horizontal plane. Installation of the cover or signal converter on the terminal box 1. Mount the cover or the signal converter on the terminal box. 2. It is important that the screws are firmly tightened (4 Nm). Use a large screwdriver fitting into the screw slot. Installation, cable Tighten the cable glands and the cable entries to obtain optimum sealing. The cable entry gasket must obtain firm contact with the cable. 6 SFIDK.PI.026.A3.02