Directional Control Valves

Similar documents
Directional Control Valves. General Description. Operation. Features

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Application. Features. Operation

Directional Control Valves. General Description. Operation. Features

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves. Features. Application. Operation

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. Application. Features. Operation.

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Directional Control Valves. Application. Features. Operation

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. Features. Application. Operation

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

Direct Operated Proportional DC Valves

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Directional Controls

Directional Controls

Directional Control Valves. General Description. Features. Specifications

Pilot-Operated Directional Control Valves Series D3 - D11

Directional Control Valve Series D1VW

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Controls

Bankable Control Valves

High Pressure, Subplate Mounted Directional Control Valves

Directional Control Valve

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Directional Control Valve Series 4D01 (DENISON)

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Chapter 2: Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Manapak Sandwich Valves. General Description

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Monobloc and Sectional Directional Control Valves

Pilot Operated Directional Valves

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

EManually Operated Directional Valves

Pressure Control Valves Series R. General Description. Specifications. Flow Data

Directional Controls

Proportional Pressure Reducing Valve Series D1FV

Directional Control Valve Series D3W Soft Shift

Directional Control Valves

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves

Directional Control Valves

Directional control valves NG6...NG32 D03...D10 6

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

D05 Directional Control Valves

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

EMechanically Operated Directional Valves

Cartridge Valves Technical Information Directional Valves DCV 03

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

3/2 and 4/2 directional seat valves with solenoid actuation

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

MDT. Monoblock directional control valves MDT - Directional control valve

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Directional Controls

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Directional Controls

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

EManually Operated Directional Valves

Mounting and Assembly of Sandwich Bodies

3/2 and 4/2 directional seat valves with solenoid actuation

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Accessories Series PSB. Specifications

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

Proportional pressure reducing valve of 3-way design

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

D03 FluiDyne Valves. ENGINEERING DATA

Monoblock directional control valves DL - Directional control valve

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

Monobloc and Sectional Directional Control Valves

NG06. General Size NG6 NG10 Design

Monobloc and Sectional Directional Control Valves

Transcription:

echnical Information General Description he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03/ CEO 3 mounting patterns. Features Mechanically tunable soft shift roportional spools, 21 standard spool styles available Repairable override DC surge suppression Nine electrical connection options C & DC lights available (CS approval for solenoids and lights) Internally ground Easy access mounting bolts Waterproof (NEM 4 rated) Explosion proof CS approved and U.L. recognized available No tools required for coil removal C rectified coils Response ime* Nominal response time (milliseconds) at 345 ar (5000 SI) is 32 L/M (8.5 GM). Solenoid ype ull-in Drop-Out C 13 20 DC 8 Watt 61 22 or 10 Watt DC 30 Watt 51 21 * For soft shift, see ordering code X-number. Specifications Mounting attern NF D03, CEO 3; NG 6 Mounting DIN 24340-6 Interface ISO 4401--03-4- CEO R35H 4.2-4-03, NF D03 Maximum,, ressure 345 ar (5000 SI) Standard CS 276 ar (4000 SI) ank: 103 ar (1500 SI) Standard 207 ar (3000 SI) Optional with H, FH, G, LG CS 103 ar (1500 SI) 2502-1.p65, dd 17 arker Hannifin Corporation Elyria, Ohio, US

Ordering Information Standard Valves D Directional Control Valve 1V asic Valve ctuator# Spool Style Seal Solenoid Voltage 2MD NF D03 CEO 3 DIN NG6 W HW Description Solenoid, Wet in, Screw-in Reversed Wiring # Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D1VHW***. N V E * Description Nitrile Fluorocarbon ER * Contact HVD for availability. D G J K L N Q R U Y Z Description 24/50 VC 120 VDC 198 VDC 24 VDC 12 VDC 6 VDC 220/50 VC 100/60 VC 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC Symbol Symbol 001 014 002 015 003 016 004 020* 005 021 006 022 007 026* 008*, 030** 009** 2502-1.p65, dd 010 081 011 082 * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spool have open crossover. See Universal Spool Chart for other spool options. Description Symbol * 2 position, spring offset to C 3 position, spring centered D 2 position, detent, to and to E F 2 position, spring centered and to 2 position, spring offset to and centered H* 2 position, spring offset to K M 2 position, spring centered and to 2 position, spring offset to and centered * 020, 026 and 030 spools only. 020 and 030 spools only. 18 b b b b b arker Hannifin Corporation Elyria, Ohio, US a a a a a

Ordering Information Standard Valves Solenoid Connection Coil Options ube Options Options Electrical Options Shift Response and Indication pprovals Valve Design Variations Series NOE: Not required when ordering. Description C Conduit ox D Metric lug (M12X1), DESIN E Explosion roof G lug-in H* Single Spade J** Deutsch (D06-25) L Dual Screw Lug M** Metri-ack (150) DIN with lug S Double Spade W* DIN w/o lug * Not available with lights. ** See valve variations for others. DC only. 2502-1.p65, dd Omit D E F** Description High Watt Explosion roof, EEXD EX Explosion roof, EEXME EX Low Watt C CS Hazardous Location L*** 8 Watt O Explosion roof, MSH U Explosion roof, UL/CS X* No Coils * See solenoid voltage code to specify proper tube. ** C only. *** DC/C Rectified only. pplicable to conduit box and plug-in style only. Omit H M G Omit R W Description Low ressure, C only High ressure, C only Low ressure, DC-WI only High ressure, DC-WI only Omit J Description Standard Extended with oot None Repairable Waterproof rotection 19 Description Omit Standard Response S2* Soft Shift, 0.020" Orifice S3* Soft Shift, 0.030" Orifice S4* Soft Shift, 0.040" Orifice S5* Soft Shift, 0.050" Orifice S6* Soft Shift, 0.060" Orifice SN* Soft Shift, No Orifice I7 Monitor Switch Direct Op. End Stroke I8 Monitor Switch Direct Op. Start Stroke * Not available with 8 watt. Description No Options Diode Surge Suppressor Rectified Coil Description Omit Standard Valve 4* C.S.. pproved K UL Recognition * Not available with high pressure tube. Description 5 Signal Lights 6 Manaplug - rad Harrison Mini 7 Manaplug - rad Harrison (12x1) Micro 56 Manaplug (Mini) with Lights 7 Manaplug (Micro) with Lights (D1 only) 1 Manaplug (Mini) Single Sol. 5-pin 1 Manaplug (Micro) Single Sol. 5-pin 1C Manaplug (Mini) Single Sol. 5-pin, with Lights 1D Manaplug (Micro) Single Sol. 5-pin, with Lights 4D wist & Lock (Old 5426) 4E ush (Old x5450) Valve Weight: Single Solenoid Double Solenoid Standard olt Kit: Metric olt Kit: 1.36 kg (3.0 lbs.) 1.6 kg (3.5 lbs.) K209 KM209 arker Hannifin Corporation Elyria, Ohio, US

Catalog HY14-2502/US echnical Information Solenoid Ratings Insulation System Class F llowable Deviation -10% to +15% for DC and C rectified coils from rated voltage -5% to +5% for C Coils rmature Wet pin type CS File Number LR60407 Environmental DC Solenoids are rated at NEM 4 (I67) Capability or better when properly wired and installed. Contact HVD for C coil applications. Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the NEC M.S.H.. (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: 1999+ mds. 1 & 2, EN50018: 2000 CS Hazardous Location Class II, Groups E, F & G * llowable Voltage Deviation +/- 10% Note that C coils are single frequency only. Voltage In Rush mps In Rush mps Holding mps Watts Resistance Voltage ower mperage D1VW V @ 3MM D1VW D1VW D1VW 24/50 VC, High Watt 7.00 mps 168 V 2.65 mps 28 W 1.67 ohm(s) D L 120 VDC N/ N/ 0.09 mps 10 W 1584.00 ohm(s) N/ N/ 0.26 mps 30 W 528.00 ohm(s) E 24/60 VC, High Watt 6.00 mps 144 V 1.85 mps 20 W 1.67 ohm(s) 24/50 VC, High Watt 7.00 mps 168 V 2.65 mps 28 W 1.67 ohm(s) G L 198 VDC N/ N/ 0.05 mps 10 W 3920.40 ohm(s) N/ N/ 0.15 mps 30 W 1306.80 ohm(s) J L 24 VDC N/ N/ 0.44 mps 10 W 51.89 ohm(s) N/ N/ 1.32 mps 30 W 17.27 ohm(s) K L 12 VDC N/ N/ 0.88 mps 10 W 12.97 ohm(s) N/ N/ 2.64 mps 30 W 4.32 ohm(s) L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohm(s) N/ N/ 5.00 mps 30 W 1.20 ohm(s) M L 9 VDC N/ N/ 1.11 mps 10 W 8.12 ohm(s) N/ N/ 3.35 mps 30 W 2.67 ohm(s) 110/50 VC 0.38 mps 19 W 135.00 ohm(s) R 24/60 VC, High Watt 8.00 mps 192 V 2.70 mps 27 W 1.40 ohm(s) F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohm(s) S ***Specials*** SEE ELOW 240/60 VC, High Watt 0.77 mps 185 V 0.26 mps 25 W 134.50 ohm(s) 220/50 VC, High Watt 0.82 mps 180 V 0.31 mps 27 W 134.50 ohm(s) F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W 145.00 ohm(s) F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W 145.00 ohm(s) U L 98 VDC N/ N/ 0.10 mps 10 W 960.00 ohm(s) X L 16 VDC N/ N/ 0.63 mps 10 W 25.60 ohm(s) Y 120/60 VC, High Watt 1.55 mps 186 V 0.49 mps 25 W 33.70 ohm(s) 110/50 VC, High Watt 1.65 mps 182 V 0.58 mps 27 W 33.70 ohm(s) F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W 36.50 ohm(s) F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W 36.50 ohm(s) L* 120/60 VC, 10 Watt 0.63 mps 83 V 0.18 mps 10 W 75.00 ohm(s) L* 110/50 VC, 10 Watt 0.73 mps 79 V 0.20 mps 10 W 75.00 ohm(s) *H 120/60 VC, High ressure 1.40 mps 168 V 0.50 mps 26 W 36.50 ohm(s) *H 110/50 VC, High ressure 1.48 mps 163 V 0.60 mps 28 W 36.50 ohm(s) Z L 250 VDC N/ N/ 0.04 mps 10 W 6875.00 ohm(s) N/ N/ 0.13 mps 30 W 1889.64 ohm(s) Specials S Other voltages/frequencies may be available Contact HVD for more information Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohm(s) 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohm(s) N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohm(s) Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W 33.50 ohm(s) 110/50 VC 1.47 mps 162 V 0.57 mps 27 W 34.70 ohm(s) Q 100/60 VC 1.90 mps 192 V 0.70 mps 27 W 38.60 ohm(s) K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohm(s) J 24 VDC N/ N/ 1.38 mps 33 W 17.33 ohm(s) D 120 VDC N/ N/ 0.28 mps 33 W 420.92 ohm(s) Z 250 VDC N/ N/ 0.13 mps 33 W 1952.66 ohm(s) 2502-1.p65, dd 20 arker Hannifin Corporation Elyria, Ohio, US

lug-in ox, Double DC Solenoid 44.9 (1.77) 87.8 (3.46) 143.7 (5.66) 54.3 Min. Coil (2.14) 1/2 NF hd. oth Ends 49.6 (1.95) (2.60) 93.2 (3.67) 244.4 (9.62) lug-in ox, Single DC Solenoid 44.9 (1.77) 87.8 (3.46) 1/2 NF hd. oth Ends 49.6 (1.95) 54.3 (2.14) Min. Coil 188.5 (7.42) (2.60) 93.2 (3.67) 2502-1.p65, dd 21 arker Hannifin Corporation Elyria, Ohio, US

Hirschmann, Double DC Solenoid 12.0 (0.47) Min. Connector 72.6 (2.86) 115.4 (4.54) 142.1 (5.59) 54.3 (2.14) Min. Coil 25.3 (1.00) 23.0 (0.91) 66.3 (2.61) 77.6 (3.06) 244.4 (9.62) Hirschmann, Single DC Solenoid 23.0 (0.91) 25.3 (1.00) 54.3 (2.14) Min. Coil 100.8 (3.97) 72.6 (2.86) 12.0 (0.47) Min. Conn. 77.6 (3.06) 66.3 (2.61) 168.3 (6.63) 2502-1.p65, dd 22 arker Hannifin Corporation Elyria, Ohio, US

Conduit ox, Double C Solenoid 36.8 (1.45) 79.9 (3.15) 126.8 (5.00) 42.75 (1.68) Min. Coil ½ NF hread oth Ends 49.5 (1.95) 3.0 (0.19) See Note (2.60) 94.6 (3.72) 210.7 (8.30) Note: 22.0 mm (.87 ) from bottom of bolt hole counterbore to bottom of valve. Conduit ox, Single C Solenoid 42.75 (1.68) Min. Coil 84.0 (3.31) 36.8 (1.45) ½ NF hread oth Ends 49.5 (1.95) 3.0 (0.19) (2.60) 94.6 (3.72) 163.7 (6.44) 2502-1.p65, dd 23 arker Hannifin Corporation Elyria, Ohio, US

Conduit ox, Double C Solenoid with Variation 6 (Manaplug) & Variation (Extended ) 36.8 (1.45) 95.7 (3.77) 126.8 (4.99) 42.8 (1.69) Min. Coil Connector NF 3.5.29 25.4 (1.00) Hex 49.5 (1.95) 3.0 (0.19) Extended (2.60) 94.6 (3.72) 61.2 (2.41) Minimum Coil 225.0 (8.86) Conduit ox, Double DC & C Rectified Solenoids with Variation 6 (Manaplug) & Variation (Extended ) Extended 36.8 (1.45) 142.1 (5.59) 95.7 (3.77) 79.9 (3.15) 54.3 (2.14) Min. Coil Connector per NF 3.5.29 25.4 (1.00) Hex (2.60) 49.5 (1.95) 3.0 (0.19) 94.6 (3.72) 72.7 (2.86) Min. Coil 255.4 (10.01) 2502-1.p65, dd 24 arker Hannifin Corporation Elyria, Ohio, US

Conduit ox, Double C Solenoid with Variation R (Repairable ) 36.8 (1.45) 79.9 (3.15) 138.1 (5.44) 54.8 (2.16) Min. Coil ½ NF hread oth Ends 3.0 (0.19) 49.5 (1.95) 94.6 (3.72) (2.60) 233.3 (9.19) Conduit ox, Double DC Solenoid with Variation R (Repairable ) 44.9 (1.77) 87.8 (3.46) 155.0 (6.10) 66.3 (2.61) Min. Coil 1/2 NF hd. oth Ends 49.6 (1.95) 93.2 (3.67) (2.60) 267.0 (10.51) 2502-1.p65, dd 25 arker Hannifin Corporation Elyria, Ohio, US

DESIN, Double DC Solenoid 48.0 (1.89) 90.7 (3.57) 142.1 (5.59) 54.3 (2.14) Min. Coil 70.3 (2.77) 50.8 (2.00) 242.4 (9.54) DESIN, Single DC Solenoid 90.7 (3.57) 142.1 (5.59) 543 (2.14) Min. Coil 70.3 (2.77) 50.8 (2.00) 167.3 (6.59) 2502-1.p65, dd 26 arker Hannifin Corporation Elyria, Ohio, US

Explosion roof U.L. & C.S.., Double Solenoid 60.4 (2.38) 163.7 (6.44) 18 Inch Lead Wires Standard 1/2" N 94.4 (3.72) 130.8 (5.15) 304.4 (11.98) Explosion roof M.S.H.., Double Solenoid 73.0 (2.87) 15.1 7.5 (0.30) 3/4-20 UNF hd. 60.4 (2.38) 163.7 (6.44) 3/4-20 UNF hd. 38.0 (1.50) 113.0 (4.45) 130.8 (5.15) 304.4 (6.44) Explosion roof EX, Double Solenoid 73.0 (2.87) 1 7.5 (0.30) 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) M20 x 1.5-6H hd. 100.9 (3.97) 42.8 (1.69) 131.7 (5.19) 100.6 (3.96) 7.5 (0.30) 73.5 (2.89) 141.0 (5.55) 324.7 (12.78) 2502-1.p65, dd 27 arker Hannifin Corporation Elyria, Ohio, US

Conduit ox, Single DC Solenoid with Variation I7 (Monitor Switch) & Variation (Extended ) 72.7 (2.86) Min.Coil 115.1 (4.53) 12.0 (0.47) Min. Conn. 49.5 (1.95) 3.0 (0.12) Extended 274.9 (10.82) 81.9 (3.22) 70.6 (2.78) 94.6 (3.72) Monitor Switch (valve variation I7) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring +18-42 volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. Regulator lock Diagram Inductor (Extended, or Energized osition) in 1 (Input 24VDC) in 2 (Output Normally Open) in 3 (Output Normally Closed) in 4 (Ground erminal) For repetitive switch power-up conditions, please consult factory. 2502-1.p65, dd 28 arker Hannifin Corporation Elyria, Ohio, US

ccessories Conduit ox (connection option G & C) Interface 152.4 cm (6.0 inch) lead wires, 18 awg. Waterproof lug-in Conduit ox NEM 4 rated hoenix connector Lights, Manaplug available Signal Lights (valve variation 5) Interface LED Manaplug (valve variations 6, 56, 630) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Solenoid (Negative) Wire #3 (Red/lack) Ground Wire #1 (Green) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Solenoid (ositive) Wire #2 (Red/White) Hirschmann lug with Lights ISO 4400/DIN 43650 Form in #2 (Negative) in #3 (Ground) in #1 (ositive) " Solenoid (ositive) Wire #1 (Red/White) " Solenoid (Negative) Wire #5 (Red/lack) " Solenoid (Negative) Wire #2 (Red) " Solenoid (ositive) Wire #4 (Red/Yellow) Ground Wire #3 (Green) 5-in Manaplug (Mini) with Lights Single and Double Solenoid Valves ("" and "" Solenoids Reversed for #8 and #9 Spools) Face View of lug Micro Connector valve variations 7, 7 Solenoid (Negative) Wire /3 (lue) Solenoid (ositive) Wire /4 (lack) DESIN Connector M12 pin assignment Standard 1 = Not used DESIN design in 1 and 2 connected Ground Wire /1 (rown) 2 = Not used "" Solenoid (Negative) Wire /1 (rown) "" Solenoid (ositive) Wire /2 (White) 3 = 0V "" Solenoid (ositive) Wire /4 (lack) Ground Wire /5 (Gray) "" Solenoid (Negative) Wire /3 (lue) 4 = Signal (24 V) 5 = Earth Ground 2502-1.p65, dd 29 arker Hannifin Corporation Elyria, Ohio, US

ccessories Series D1V Mounting olt Kits olt Kits for use with D1V & Manapaks (D1V*-82 & 70/75 Design, Solenoid Operated & D1V*-60 Design, Non-Solenoid Operated) Number of Manapaks at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Manapaks/Cartpaks @40mm (1.58") thickness 0 1 2 3 4 K209 1.25 in. K243 2.88 in. K225 4.38 in. K244 6.00 in. K245 7.50 in. KM209 30 mm KM243 70 mm KM225 110 mm KM244 150 mm KM245 190 mm K246 3.00 in. K247 4.62 in. K248 6.12 in. K249 7.75 in. KM209 75 mm KM247 115 mm KM248 155 mm KM249 195 mm K250 4.75 in. K251 6.38 in. K252 7.88 in. KM250 120 mm KM251 160 mm KM252 200 mm K253 6.50 in. K254 8.12 in. KM253 165 mm KM254 205 mm K103 8.25 in. KM103 210 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). olt Kits for use with D1V with Explosion roof Coils & Manapaks (D1V*-82 & 70/75 Design) Number of Manapaks at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Manapaks/Cartpaks @40mm (1.58") thickness 0 1 2 3 4 K50 2.00 in. K211 3.63 in. K101 5.12 in. K102 6.75 in. K103 8.25 in. KM51 50 mm KM101 130 mm KM102 170 mm KM103 210 mm K51 3.75 in. K212 5.37 in. K105 6.87 in. K106 7.75 in. KM209 95 mm KM105 175 mm KM106 195 mm K52 5.50 in. K213 7.13 in. K108 8.62 in. KM52 140 mm KM108 220 mm K53 7.25 in. K214 8.87 in. KM53 185 mm K54 9.00 in. KM54 230 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). Sandwich Valve Dimensional Data ll D03 Manapak valves (starting with 31 Series) including CM2, COM2, FM2, RDM2 and RM2 measure 40mm (1.58 ) thickness. For additional technical information about Manapak valves, refer to the Manapak Sandwich Valve Section of this Catalog. 2502-1.p65, dd 38 arker Hannifin Corporation Elyria, Ohio, US

Installation Information Series D1V Fluid Recommendations remium quality hydraulic oil with a viscosity range between 150-250 SSU (32-54 cst) at 38 C (100 F) is recommended. he absolute operation viscosity range is from 80-1000 SSU (16-220 cst). Oil should have maximum anti-wear properties and rust and oxidation treatments. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate ester or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions, and petroleum oil may be used with NIRILE seals. emperature Recommendation Recommended oil temperature: -7 to +71 C (-20 to +160 F) Filtration For maximum valve and system component life, the system should be protected at a contamination level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 or better, ISO 16/13). ank Line Surges If several valves are piped with a common tank line, flow surges in the line may cause unexpected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are expected in an application. Recommended Mounting osition Valve ype Detent (Solenoid) Spring Centered Spring Offset Recommended Mounting osition Horizontal Unrestricted Unrestricted Silting Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Single ass Operation Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local arker representative for details. Flow ath Data D1V Operator Locating pin Operator *Note: On valves with 008 or 009 spool, and/or operators reverse sides. Flow paths remain the same as viewed from top of valve. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. he center condition exists on detent and spring offset valves only during spool crossover. o shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. he minimum duration of the signal is approximately 0.1 seconds for DC voltages. his position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in styles, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Electrical Failure Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence. orque Specifications orque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: #10-24 thread (M5-0.8) torque 5.6 Nm (50 in-lbs). 2502-1.p65, dd 39 arker Hannifin Corporation Elyria, Ohio, US