Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To

Similar documents
Battery, Testing, Charging Using Midtronics MCR340V Battery Analyzer or InCharge 940 (INC-940) Battery Charging Station

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

MDX-653P INSTRUCTION MANUAL. Battery Conductance and Electrical System Analyzer

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

BBT-205. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

MDX-645 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

Bulletins - SI/MI - ( ) Battery maintenance program

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To All All All All

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To. Passat Wagon 2007 BPY (2.0L) All 3C_7E C_7E051587

Mazda North American Operations Irvine, CA MULTI-MODEL - BATTERY TEST PROCEDURE REQUIREMENTS USING THE GR BULLETIN NOTE

MDX-700P HD INSTRUCTION MANUAL. Battery Conductance and Electrical System Analyzer

DESCRIPTION & OPERATION

MDX-645P INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

BATTERY & STARTER ANALYSER (BSA-12) User Manual

MIL ON - DTC'S P047F, P0477, P048A, P048B, P048C OR P0401 STORED IN ECM FAULT MEMORY

TECHNICAL SERVICE BULLETIN

Drivetrain Binding/Tires Scrubbing During Low Speed Maneuvering, ESP Light in Instrument Cluster ON or Flashing

BVA-460 Operator's Manual

MDX-640 MDX-640 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

2001 Dodge Durango ACCESSORIES & EQUIPMENT' 'Anti-Theft Systems - Dakota & Durango 2001 ACCESSORIES & EQUIPMENT

Generator: All Technical Service Bulletins Charging System - No Start/Generator Lamp Flashing Group: 27

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To 2.0L TDI (CBEA) 2.0L TDI (CJAA) 2.0L TDI (CJAA) 2.0L TDI (CJAA)

BVA-350 Operator s Manual

Service Bulletin

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To > 2004 All All All All > 2004 All All All All

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To. All All All

2/2/2018 Feed Circuit Test (Starting System) - ALLDATA

TABLE OF CONTENTS. Page 1

SB-300 Operator s Manual

Gary Mackey National Sales Manager Associated Equipment Corporation

Don't just Perform Service - Sell It!

BVA-230 Operator's Manual

2007 Dodge Nitro R/T ENGINE Starting - Service Information - Nitro. Starting - Service Information - Nitro

Previous versions of this TSB should be discarded. TSB UPDATE NOTICE: The information contained in this TSB supersedes TSB No. PG

R230 Dual Battery On-board Electrical System. 218 HO Dual Battery (ACB)

Title: M.I.L. ON DTC P3191, P3190, AND/OR P0A0F Models:


DSS-7000 INSTRUCTION MANUAL. Battery Diagnostic Service System. For testing 6- and 12-volt automotive and 12-volt and 24-volt charging systems.

ALTERNATOR REQUESTED INFORMATION. Vehicles With Dual Generator [ Engine Mount - LH ] 2007 Ford Pickup 6.0L Eng F350 Super Duty

DIGITAL BATTERY TESTER 12V

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

Battery Cut-Off Switch, Disconnecting and Removing During the Pre-Delivery Inspection (PDI) 2004, 2005

Model ATD V Battery Condition & Charging System Tester Tests 12V Auto/Truck and Non Auto Batteries and 12V charging systems.

4.0L CEC SYSTEM Jeep Cherokee DESCRIPTION OPERATION FUEL CONTROL DATA SENSORS & SWITCHES

User Manual. Solar Charge Controller 3KW

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

User s Manual. Automatic Switch-Mode Battery Charger

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Heavy-Duty Battery and Electrical System Diagnostic Tester

# : SMU - Revised DTC P0341 Camshaft Position (CMP) Sensor Performance - (Feb 20, 2002)

Disclaimer. Safety Precautions and Warnings. NexBat NB300 12V Battery Analyzer

Passenger s Side Airbag, On Board Diagnostic (OBD) Service

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

Udiag BST300 Battery Tester User Manual

BATTERY TESTER ANALYZER

STARTING SYSTEM TEST STARTING SYSTEM

VAS 6161 INSTRUCTION MANUAL. Vehicle Battery and Electrical Diagnostic Platform

00 02 Apr. 24, Service

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

777P-PT Battery Charging/Starting System Analyzer with Printer

USER, s. k SULFURIC ACID CAN CAUSE BLINDNESS OR A DANGER/POISON SHIELD EYES EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY NO SPARKS, FLAMES, SMOKING

CLEAN POWER TM CPS Series Operator s Manual

REQUIRED VEHICLE UPDATE TECHNICAL BULLETIN (RVUTB) PERFORM ON ALL APPLICABLE VEHICLES WITHIN THE LIMITED NEW VEHICLE WARRANTY

PTI900X PST-900X. Battery Tester with Printer. For 6 and 12 Volt batteries and 24 Volt charging systems OWNERS MANUAL

All. Battery! Current draw procedure introduced in VAS 5051A1B scan tool with the release of software version

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

Table of Contents. Chapter 1 Product Summary... 2

Volkswagen Phaeton 43-2

Smart Battery Charger

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

INTRODUCTION OF A HANDS-ON BATTERY AND SYSTEM ANALYZER. CONDUCTANCE PROFILING TM Where did the need come from?

1 of 8 9/11/2015 3:59 PM

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

DSS-7000 INSTRUCTION MANUAL. Midtronics Battery Diagnostic Service System

TECHNICAL BULLETIN No:

User Manual Solar Charge Controller 3KW

TECHNICIAN SAFETY INFORMATION

BASIC DIAGNOSTIC PROCEDURES

AUTO CHARGE LPC SERIES

CHARGING SYSTEM SECTION CHG CONTENTS ELECTRICAL & POWER CONTROL CHG-1 PRECAUTION... 3 WIRING DIAGRAM... 9 BASIC INSPECTION...13 PREPARATION...

THE ALT AL ERNA RN T A OR

Volkswagen Golf > VW Rabbit GTI 2006-> (A5)

LIST OF CONTENTS TESTING EQUIPMENT

2002 Ford Explorer STARTING & CHARGING SYSTEMS' 'Generators & Regulators - Explorer & Mountaineer STARTING & CHARGING SYSTEMS

Wireless Charging Device Compatibility and Testing

PRELIMINARY INSPECTION & ADJUSTMENTS

SP6. Automatic Battery Charger. Model

1998 ENGINE PERFORMANCE. General Motors Corp. - Basic Diagnostic Procedures - 5.7L

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

Models: SP3, SPSS3 Automatic Battery Charger

FUNCTION SELECTION. Check the Trouble Code SCAN-100. Preceding Work: Perform the Entering Diagnosis Procedures

EXP-1003 HD INSTRUCTION MANUAL. Expandable Electrical Diagnostic Platform

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS

# Traction Control Window Switch

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

#97-T-20A: MIL (Service Engine Soon Telltale Lamp) On and EGR DTCs P0401, P0404, P0405, P1404 and/or P1406 in PCM Memory - (Jan 6, 2003)

Transcription:

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To All 1998-2010 All All All All Condition 27 10 01 May 26, 2010 2011894 Supersedes T. B. Group 27 number 08-06 dated Sept. 30, 2008 due to addition of VAS 6161 and additional battery instruction and specifications. Battery, Testing and Charging Using Midtronics VAS6161, MCR340V Analyzer or InCharge 940 Charging Station Note: This technical bulletin covers testing and repair procedures for multiple vehicle lines, model years and engine combinations. To prevent mis-diagnosis, you must ensure that the testing/repair procedure is applicable to the vehicle you are servicing. Technical Background The VAS6161, MCR340V and In-Charge 940 (INC-940) are the only VW approved battery testers and chargers that can be used to test and charge batteries in VW vehicles. Use of non-approved battery testers and chargers is not allowed, as internal battery damage may occur. Production Solution No production change required. Service WARNING Danger of injury! Prior to handling or servicing batteries, read, understand and observe all Warnings and Safety Measures for lead-acid batteries. Note: In order to prevent damage to battery or vehicle, observe battery type descriptions and notes. Switch off all electrical consumers. Switch ignition OFF and remove ignition key. Page 1 of 21

Battery Testing/Charging Sections: 2-1 All Models 1998-2010, Except New Passat 3.6L, Eos 3.2L, Golf VR4/R32, Touareg, Phaeton and Routan 2-2 B6 Passat, Passat Wagon and CC with 3.6L 2006-2010 (Rear Battery) 2-3 Eos 3.2L 2006-2008 2-4 Golf VR4/R32 2010 2-5 Touareg 2004-2010 2-6 Phaeton 2003-2006 2-7 Routan 2009-2010 2-8 MCR340V, INC-940, Trouble Shooting Error Messages 2-1 All Models 1998-2010, Except New Passat 3.6L, Eos 3.2L, Golf VR4/R32, Touareg, Phaeton and Routan DO NOT remove battery from vehicle to test; always test battery in vehicle except for the following conditions: Battery was removed for a separate repair prior to performing battery test. Over the counter (after market) parts. When testing or charging a battery either installed or removed from vehicle select appropriate battery type: Select Standard (Lead-Acid) function for ALL NON-AGM batteries. Select AGM function for Absorbent Glass Mat (AGM) batteries with AGM on battery label. Always use actual DIN rating as shown on battery label -arrow-. Label shown is for example only. DIN or SAE specifications may vary from battery to battery. Page 2 of 21

If DIN rating is not shown: Use SAE value as printed on the battery label. If using SAE value rating: Midtronics tester menu option must be changed to achieve accurate results. A change from DIN to SAE can be made from the Other menu option on Midtronics tester. 2-2 B6 Passat, Passat Wagon and CC with 3.6L 2006-2010 (Rear Battery) Testing/Charging at Battery DO NOT remove battery from vehicle to test; always test battery in vehicle except for the following conditions: Battery was removed for a separate repair prior to performing battery test. Over the counter (after market) parts. B6 Passat Sedan, CC, 3.6L only 2006-2010: Select Lead Acid Battery for 3.6L engine (located in left side of trunk). 450 DIN. B6 Passat Wagon 3.6L only 2006-2008: Select AGM (Absorbed Glass Mat) for 3.6L engine (located in left side of trunk). 480 DIN or 520 DIN. When testing or charging battery installed in vehicle: DO NOT Test/Charge from Remote Location. Page 3 of 21

(3.6L) DO NOT use remote location (+) - arrow-. (3.6L) DO NOT use engine bracket (-) - arrow-. Always use actual DIN rating as shown on battery label: (3.6L) Test/charge battery located in left rear trunk -arrow-. Passat Sedan / Passat CC 3.6L uses a lead acid battery 450 DIN. Passat Wagon 3.6L uses an AGM battery. 480 or 520 DIN. Page 4 of 21

2-3 Eos 3.2L 2006-2008 Testing/Charging at Battery (Two 6-Volt batteries) Eos 3.2L engine is equipped with two 6-volt AGM batteries which are connected in series to achieve 12-volts. The battery system must always be treated as a 12-volt battery system. Never attempt to charge only one 6-volt battery. If battery replacement is necessary, never replace one 6-volt battery; both batteries must be replaced as a pair! Eos 3.2L AGM batteries shown are connected in series. DO NOT remove battery from vehicle to test; always test battery in vehicle except for the following conditions: Battery was removed for a separate repair prior to performing battery test. Over the counter (after market) parts. Page 5 of 21

Testing/Charging 6-Volt Batteries Out of Vehicle: If batteries have been removed from vehicle, never attempt to test/charge one 6-volt battery; as stated above. Treat batteries as a 12-volt system. Connect cable (Part No: 1Q0971226) to inner battery terminals. Connect battery tester. Cable has (+) and ( ) stamps on each terminal. Positive (+) terminal is a larger diameter than Negative ( ) terminal. DO NOT attempt to force the wrong terminal of harness onto a battery terminal if it does not fit. 1. Connect cable with positive (+) stamp to inner positive (+) terminal of 1st battery. When doing so, ensure that the other end of the cable (negative) does not make contact with ground or any object. Tighten to 6Nm. 2. Connect the negative ( ) terminal of the cable to the inner negative ( ) terminal of the 2nd battery. Tighten to 6Nm (53 in. lbs). 3. Connect Midtronics tester positive (+) clamp (red color) to outer positive (+) terminal of 2nd battery. 4. Connect Midtronics tester negative ( ) clamp (black color) to outer negative ( ) terminal of 1st battery. Page 6 of 21

When testing/charging is completed: 1. Remove Midtronics tester negative ( ) clamp (black color). 2. Remove Midtronics tester positive (+) clamp (red color). 3. Remove battery cable negative ( ) connection at 2nd battery negative ( ) terminal. 4. Remove battery cable positive (+) connection at 1st battery positive (+) terminal. Testing/charging 6-Volt Batteries in Vehicle: INC-940 1. Connect Midtronics tester positive (+) clamp (red color) to outer positive (+) terminal of battery. 2. Connect Midtronics tester negative ( ) clamp (black color) to outer negative ( ) terminal of other battery. MCR340V and VAS6161 1. Connect Midtronics tester positive (+) clamp (red color) to outer positive (+) terminal of battery. 2. Connect Midtronics tester negative ( ) clamp (black color) to outer negative ( ) terminal of other battery. Testing/Charging In or Out of Vehicle: Always verify using DIN rating as shown on battery label. Select AGM for 3.2L engine (located in the trunk, one 6-volt battery on each side of the ski-chute). 380 DIN. Page 7 of 21

Label shown is for example only. DIN or SAE specifications may vary from battery to battery. Two 6-volt batteries are connected in series to achieve 12-volts, the same current value will flow through each battery. As a result, only use a DIN value of 380A, DO NOT double or halve this value when entering data into Midtronics tester. If DIN rating is not shown: Use SAE value as printed on battery label. If using SAE value rating: Midtronics tester menu option must be changed to achieve accurate results. A change from DIN to SAE can be made from the Other menu option on Midtronics tester. When testing or charging battery installed in vehicle: DO NOT Test/Charge from Remote Location (3.2L). (3.2L) DO NOT use remote location (+) - arrow-. Page 8 of 21

(3.2L) DO NOT use engine bracket (-) - arrow-. (3.2L) Test/charge AGM battery located in trunk - one 6V battery located on each side of ski chute, as shown. Page 9 of 21

2-4 Golf VR4/R32 2008-2010 Testing/Charging at Battery DO NOT remove battery from vehicle to test; always test battery in vehicle except for the following conditions: Battery was removed for a separate repair prior to performing battery test. Over the counter (after market) parts. When testing or charging battery either installed or removed from vehicle: Select Standard (Lead-Acid) battery. Located in right trunk area under spare tire and tool kit. Always use actual DIN rating from battery label. When testing or charging battery installed in vehicle: DO NOT Test/Charge from Remote Location (3.2L). (3.2L) DO NOT use remote location (+) - arrow-. Page 10 of 21

(3.2L) DO NOT use engine bracket (-) - arrow-. Always use actual DIN rating from battery label. (3.2L) Test/charge (Lead Acid) battery located in the trunk. Page 11 of 21

2-5 Touareg 2004 2010 Testing/Charging at Battery Single System 3.0L (TDI) 3.2L, 3.6L, and 4.2L Engines Start/Accessory battery Always use actual DIN rating as shown on battery label. Select Standard (Lead-Acid) for 3.2L, 3.6L, and 4.2L engines (located under driver's seat). 450 DIN. Select Standard (Lead-Acid) for 3.0L TDI engine (located under driver's seat). 520 DIN. Dual System 5.0L (TDI) Engine Accessory battery Select Standard (Lead Acid) for 5.0L (TDI) (located under the driver seat). 450 DIN for AH battery 520 DIN for AK battery Page 12 of 21

Starter battery For 5.0L (TDI) engine (battery in trunk without rim). AGM 480 or 520 DIM. For 5.0L (TDI) engine (battery in trunk located under spare tire). Standard lead acid 450 DIN. Note: Starter battery must be checked independently of accessory battery. Starter battery cannot be tested or charged via the remote location in engine compartment. To test or charge starter battery, go directly to battery terminals. Always use actual DIN rating as shown on battery label -arrow-. Label shown is for example only. DIN or SAE specifications may vary from battery to battery. If DIN rating is not shown: Use SAE value as printed on battery label If using SAE value rating: The Midtronics tester menu option must be changed to achieve accurate results. A change from DIN to SAE can be made from the Other menu option on Midtronics tester. Page 13 of 21

Testing/Charging from Remote Location (Reduced DIN Rating Requirement) When using remote location terminals - arrows-, located in engine compartment, always reduce DIN rating on MCR340V or INC-940 testers. 3.2L, 3.6L, and 4.2L engines: 270 DIN. 3.0L, 5.0L (TDI) engine: 295 DIN. Note: For 5.0L (TDI) engine (dual battery system), starter battery cannot be tested or charged via remote location in engine compartment. To test or charge starter battery, go directly to battery terminals. Use of these reduced DIN ratings are required to compensate for the internal battery manager and/or the extended length of cable due to battery location. 2-6 Phaeton 2003-2006 Testing/Charging at Battery DO NOT remove battery from vehicle to test; always test battery in vehicle except for the following conditions: Battery was removed for a separate repair prior to performing battery test. Over the counter (after market) parts. When testing or charging battery either installed or removed from vehicle: Select Standard (Lead-Acid) for 4.2L and 6.0L engines (located in right front trunk). Select AGM (Absorbed Glass Mat) for 4.2L and 6.0L engines (located in left side trunk). Page 14 of 21

Always use actual DIN rating as shown on battery label -arrow-. Label shown is for example only. DIN or SAE specifications may vary from battery to battery. If DIN rating is not shown: Use SAE value as printed on battery label. If using SAE value rating: Midtronics tester menu option must be changed to achieve accurate results. A change from DIN to SAE can be made from the Other menu option on Midtronics tester. Dual System Starter battery Always use actual DIN rating as shown on battery label. Starter battery (Standard) located in right side trunk, as shown: 330 DIN. Page 15 of 21

On-board accessory battery Always use actual DIN rating as shown on battery label. (AGM) On-board accessory battery located in left side trunk, as shown: 480 DIN or 520 DIN. When testing or charging battery installed in vehicle: DO NOT Test/Charge from remote location DO NOT use remote location (+) or (-), - arrows-, as shown. Test/charge batteries directly, located in trunk. There is a plastic sleeve on remote location (-), -arrow-. Page 16 of 21

2-7 Routan 2009-2010 Factory battery label with CCA specification Routan original factory battery has CCA rating of 600 amps. Original factory battery showing Chrysler part number with Reserve Capacity and CCA rating of 600-AMPS. When testing original factory battery with Midtronics MCR340V or INC-940 you must use test selection DIN which is the default setting of both Midtronics testers. Spare part battery label showing Volkswagen part number, Amp hour, and DIN rating of 360A. Use a DIN rating of 360A when testing battery with Midtronics testers to obtain correct Midtronics printouts for all warranty claims. Page 17 of 21

2-8 MCR340V, INC-940, Trouble Shooting Error Messages MCR340V / INC-940 Displays "System Noise" at Beginning of Test MCR340V and INC-940 may display "System Noise" at beginning of battery test when testing directly at battery. This is an infrequent and a normal message which may be caused by: Ignition left in "ON" position. Accessories or loads turned ON, with key in "ON" position. Loads running with ignition switched "OFF" such as: cooling fan or after-run coolant pump. Aftermarket equipment (due to improper installation), such as entertainment, security, remote starters, televisions, lighting, etc.). This may be overcome by verifying: Ignition is switched "OFF". All loads (cooling fan or after-run coolant pump) are OFF prior to testing. Any aftermarket equipment is disconnected from vehicle's electrical system. Wait a few minutes, and then retest battery again. Battery Testing Results: Midtronics MCR340V Analyzer vs. INC-940 Charging Station In some cases, when testing a battery using the MCR340V tester: Test results may be Good Battery - Recharge. However, when attempting to charge the same battery with INC-940 Charger: Results may be to Replace Battery either after testing or during charging process. This is normal since both MCR340V and INC-940 use a conductance test, but the INC-940 also incorporates use of a 150A load test and sophisticated charging algorithm which monitors charging state of the battery. In this case, results of INC-940 should always be used instead of MCR340V. Page 18 of 21

Charging System Test Results at: Low Charging Voltage Using Midtronics MCR340V Analyzer If performing a charging system test with Midtronics MCR340V tester directly at battery: Test results may be Problem - Low Charging Voltage This result may be due to a faulty generator, however, DO NOT automatically assume the generator is faulty. The MCR340V is connected at the battery, low charging voltage could be due to excessive voltage drop on generatorbattery cable, poor connections, contaminated or faulty grounds in charging system. To deem the generator faulty: Verify charging voltage and current output, directly at generator, using the 5051 measurement tools functions. Test generator at the back or as close as possible to achieve accurate results. Failure to properly diagnose concern may lead to replacement of unnecessary parts, which could result in a denied warranty claim. Charging System Test Result at: Excess Ripple Detected Using Midtronics MCR340V Analyzer If performing a charging system test with Midtronics MCR340V tester directly at battery: Test results may be Problem - Excess Ripple Detected. Result may be due to periodic system noise in vehicle s electronics system or possible low battery voltage. To ensure test results are accurate: Always retest directly at battery and perform any action as directed by Midtronics tester (good, recharge or replace). Perform charging system test again at battery. Testing/Charging: INC-940 Charging Station -Automatic Mode- When using INC-940 Battery Charging Station in Automatic Mode, and testing or charging a deeply discharged battery: INC-940 may continuously display a message Are clamps connected? In order to test battery: Manually charge battery for 30 minutes and perform test again. Testing/Charging: INC-940 Charging Station -Manual Mode- When using INC-940 Battery Charging Station in Manual Mode, and testing or charging a deeply discharged battery: INC-940 may display a message Are clamps connected? twice. This is not a result of defective INC-940 test equipment, but is a safety feature of the INC-940 to ensure cables are connected to battery before power is turned ON. Page 19 of 21

INC-940 Charging Station Always Displays Check Connections INC-940 may constantly display a message to Check Connections after cables are connected to battery terminals. This is most likely due to the sensing probe making contact with the clamp. There is one sensing probe on each clamp, (+) and (-), make sure to check both! There must be no contact between the inside connection and outside jaw of clamp -arrows-. Inside connection is bent and touching outside of the clamp, -arrows-. If clamp is incorrect: Use a small flat tool and gently bend sensing probe so it does not make contact with clamp. If this does not resolve the issue: Contact Midtronics Corporation Customer Service Department at 1-800-776-1995 for assistance. Page 20 of 21

Warranty Information only. Required Parts and Tools No Special Parts or Tools required. Additional Information All part and service references provided in this Technical Bulletin are subject to change and/or removal. Always check with your Parts Dept. and Repair Manuals for the latest information. Page 21 of 21