Uninterruptible Power Supply

Similar documents
Uninterruptible Power Supplies

NetSure. 211 Series DC Power System

Liebert PowerSure PSI UPS

Sola 3000 Guide Specifications

Industrial Power Supplies

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Uninterruptible Power System

Amperis battery regenerator

AT30 SERIES BATTERY CHARGER

FlexPoint TM. Series UPS. Technical Manual FlexPoint 1208-F / 1232-D / 1250-D Series Indoor UPS Effective: September, 2015

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

15 Watt Low-Profile Wall Plug-In, Single Output, 5-24 VDC Switching Power Supply: N.A., Universal Input, ITE, Class II, Energy Star

Uninterruptible Power System

Technical Data Sheets

Uninterruptible Power System

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Power and Cooling. Chassis Power System

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

MD60 Series 60W DINergy Power Supply

3 Uninterruptible Power Systems

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.

2 Uninterruptible Power Systems

POWER-WIN TECHNOLOGY CORP.

3 Uninterruptible Power Systems

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Powerware Vdc Extended Battery Cabinet User s Guide.

A36D CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY BATTERY CHARGER / POWER SUPPLY. Standard Features

3 Uninterruptible Power Systems

FlexPoint TM. Series Power Supplies. Technical Manual FlexPoint 1215 / 1232 / 1250 Series Indoor Power Supplies Effective: August, 2015

SCXI Power Supply/Float Charger Installation Guide

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheets

Delta All-In-One Storage solutions

GENCORE 5 FUEL CELL SYSTEM System Fundamentals

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

VERTIV XTE 401 SERIES. Ordering Guide

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Solid State Relays, 3-phase

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Uninterruptible Power Supplies

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Non-Spring Return EconoDrive Floating Actuator

Technical Data Sheets

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Three-Phase Soft Starters

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

CPS2000 Cabinet Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

3 Uninterruptible Power Systems

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

FlexPoint UPS System. Technical Manual. Residential & MDU Applications. FlexPoint FP1230, FlexPoint FP1230F Power Supply Models

Security Plus Online Uninterruptible Power Supply

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Allen-Bradley 1609-D600N

Switching Power Supplies

Phase Modular Finally the benefits of Modular ups are for all

Technical Specifications

PRODUCT SPECIFICATION File: EA- 400ET1-10 Date: Jul., 28, 2006

Application. Battery. Public Grid GS HYBRID INVERTER

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

Uninterruptible Power Supply

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

On-line, Single Phase, Double Conversion UPS

400W / 600W / 1000W / 1500W DIY Wind Turbine

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

RWS50B RWS100B RWS150B RWS300B RWS600B

Safety Standards. Model Number:

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

AccuPower AQU126B Installation Instructions

Eclipse Plus VA UPS and Surge Suppressor User s Manual

PRODUCT SPECIFICATION File: EA-600ETF-C10 Date: Mar. 29, 2010

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Technical Data Sheets

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Installation and Operations Manual

Limousin II User Manual

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

AccuPower AQU128B Installation Instructions

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Uninterruptible Power Systems. SDU DC Series

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Uninterruptible power supplies (UPS)

Technical Data Sheets

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

596 Rectifier Retrofit

Technical Data Sheets

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

Transcription:

Uninterruptible Power Supply (DUPS-1232) Main Features Up to 32W Output, under 38W for 10 minutes. User-friendly interface - Dry Contact Communication. Wide input voltage range - 90~264Vac. Wall Mount (horizontal or vertical) design for easy Installation. Applications (Backup power Supply DC UPS) Optical Network Terminal (ONT)-GPON & BPON Asynchronous Digital Subscriber Line (ADSL) WiMax, Residential Gateway (RG) and other CPE fiber equipments. Over the past couple of years, there has been a revolution in telecommunications technology. That is the Fiber Terminal equipments associated with the FTTx technology. FTTx is the access network infrastructure that enables full triple play to deliver voice, data and video for the connected home or business. FTTx changes the way we live, work and play. Moreover, FTTx not only needs backup power to prevent utility power failure, but also supports making emergency calls (Ex: 911) for help. Delta DUPS-1232 is a specified backup power system designed to meet the requirements for basic ONT, signal family unit SFU and power on FTTx applications. The power system integrated AC/DC circuit, lightning protect device and battery backup power (use of 12V/ 7Ah battery) into one compact enclosures. It provides the output of 32W (+12V/ 2.7 A DC output) with features of wide input voltage range and wide ambient environment.it is suitable for FTTx, xdsl, RG and Wimax applications.

Technical Specifications(DUPS-1232)(GES320W12V0001) Normal Mode- Input Input Frequency Normal Mode- Output Output Voltage Efficiency Backup Mode- Output Voltage, nominal 13.5 ± 5% Vdc Noise: 200 mv Peak -Peak 79% @ 120/230Vac Full Load (With Full Battery Capacity) 10 ~ 20 ± 5% Vdc Noise: 200 mv Peak-Peak Efficiency @Full Load 90 % Backup Time - 32 W load 1.8hrs - 8 W load 8.0hrs Auxiliary Power Information (Use of Alkaline Battery) Coax Jack connector. Dimension (OD: 3.8 mm / ID: 1.3mm) Battery Information Battery Type Battery Charger Voltage@25ºC Battery Shutdown Voltage 90~264Vac 47~70Hz Input Surge IEC1000-4-5 @ Level 2 12.5 ~ 20Vdc VRLA 12V/7Ah (or 7.2Ah) 13.6 ± 3% Vdc 10.5 ± 3% Vdc Unit Output Short Circuit Output Overload Output Overvoltage Shutdown @ Non-Latch 3.5A ± 10 % Shutdown @ Non-Latch >25V ± 5%Vdc @ Transfer to battery until 10.5V shutdown. LED Indicator Information AC Mode Green LED (1) Light Battery Backup Mode / Low Battery Green LED (2) Light / Flash / Battery Missing Red LED (3) Light Auxiliary Power Green LED (4) Light Interface Signal Information On Battery Open @power is being taken from the battery Open @ the battery fails self-test Battery Missing Open @ the battery is missing or open circuit. Battery Low Regulatory Approvals Safety Agency EMC Environment Operating Temperature Operating Humidity Storage Temperature Storage Humidity Altitude Physical Information Input Inlet Open @ the battery is near ~ 45% capacity. UL 60950-1, CAN / CSA-C22.2 No. 60950-1,IEC 60950-1, EN 60950-1,CB FCC Part 15 Class B, CE EN55022(CISPR 22) Class B, C-Tick (AS / NZS CISPR 22) Class B, EN 300386-1 Class B 0 ~ +10000 Feet IEC320 / C6 3-prong Audible Alarm Information Backup Mode Low Battery 1 time / 1 beep (on : 1 second) 4 beeps / 1 min (on : 0.5 second) Output Connector (Accept #16~ 26 AWG) Weight @ without battery 3.5mm removable, 7pins screw terminal connector 0.8Kg /1.8lbs 1 beep / 15 min (on : 0.5 second) Dimension(H*W*D) 179*218*78mm / 7.0*8½*3.0 inch ** Order Information Delta Part Number IEC320 /C6 Inlet Din 7pins Connector Pins Assignment DC UPS 1232 Unit AC Power Cord Options USA (NEMA 5-15P) (8 ft) UK (BS1363) (6 ft) FR/GE (CEE 7/7) (6 ft) AU (AZ/NZS3112 ) (6 ft) GES320W12V0001 3090228102 3090233300 3090232700 3090233400 * The specification selection of input power cord may vary in different countries. ** Design and specifications are subject to change without notice. www.deltaww.com 39 Section 2 Huandong Road, Shanhua Township, Tainan County 74144, Taiwan,R.O.C. http://www.deltaww.com TEL 886-6-5056565 FAX 886-6-5051919

Uninterruptible Power Supply (DUPS-1232)(Hi-Surge) Main Features Up to 32W Output, under 38W for 10 minutes. User-friendly interface - Dry Contact Communication. Wide input voltage range - 90~264Vac. Wall Mount (horizontal or vertical) design for easy Installation. Applications (Backup power Supply DC UPS) Optical Network Terminal (ONT)-GPON & BPON Asynchronous Digital Subscriber Line (ADSL) WiMax, Residential Gateway (RG) and other CPE fiber equipments. Over the past couple of years, there has been a revolution in telecommunications technology. That is the Fiber Terminal equipments associated with the FTTx technology. FTTx is the access network infrastructure that enables full triple play to deliver voice, data and video for the connected home or business. FTTx changes the way we live, work and play. Moreover, FTTx not only needs backup power to prevent utility power failure, but also supports making emergency calls (Ex: 911) for help. Delta DUPS-1232 is a specified backup power system designed to meet the requirements for basic ONT, signal family unit SFU and power on FTTx applications. The power system integrated AC/DC circuit, lightning protect device and battery backup power (use of 12V/ 7Ah battery) into one compact enclosures. It provides the output of 32W (+12V/ 2.7 A DC output) with features of wide input voltage range and wide ambient environment.it is suitable for FTTx, xdsl, RG and Wimax applications.

Technical Specifications(DUPS-1232)(GES320W12V1001)(Hi-Surge) Normal Mode- Input Input Frequency Input Surge Normal Mode- Output Output Voltage Efficiency Backup Mode- Output Voltage, nominal 13.5 ± 5% Vdc Noise: 200 mv Peak -Peak 79% @ 120/230Vac Full Load (With Full Battery Capacity) 10 ~ 20 ± 5% Vdc Noise: 200 mv Peak-Peak Efficiency @Full Load 90 % Backup Time - 32 W load 1.8hrs - 8 W load 8.0hrs Auxiliary Power Information (Use of Alkaline Battery) Coax Jack connector. Dimension (OD: 3.8 mm / ID: 1.3mm) Battery Information Battery Type Battery Charger Voltage@25ºC Battery Shutdown Voltage 90~264Vac 47~70Hz NEBS GR1089 issue 4 (6kV) 12.5 ~ 20Vdc VRLA 12V/7Ah (or 7.2Ah) 13.6 ± 3% Vdc 10.5 ± 3% Vdc Unit Output Short Circuit Output Overload Output Overvoltage Shutdown @ Non-Latch 3.5A ± 10 % Shutdown @ Non-Latch >25V ± 5%Vdc @ Transfer to battery until 10.5V shutdown. LED Indicator Information AC Mode Green LED (1) Light Battery Backup Mode / Low Battery Green LED (2) Light / Flash / Battery Missing Red LED (3) Light Auxiliary Power Green LED (4) Light Interface Signal Information On Battery Open @power is being taken from the battery Open @ the battery fails self-test Battery Missing Open @ the battery is missing or open circuit. Battery Low Regulatory Approvals Safety Agency EMC Environment Operating Temperature Operating Humidity Storage Temperature Storage Humidity Altitude Physical Information Input Inlet Open @ the battery is near ~ 45% capacity. UL 60950-1, CAN / CSA-C22.2 No. 60950-1,IEC 60950-1, EN 60950-1,CB FCC Part 15 Class B, CE EN55022(CISPR 22) Class B, C-Tick (AS / NZS CISPR 22) Class B, EN 300386-1 Class B 0 ~ +10000 Feet IEC320 / C6 3-prong Audible Alarm Information Backup Mode Low Battery 1 time / 1 beep (on : 1 second) 4 beeps / 1 min (on : 0.5 second) Output Connector (Accept #16~ 26 AWG) Weight @ without battery 3.5mm removable, 7pins screw terminal connector 0.8Kg /1.8lbs 1 beep / 15 min (on : 0.5 second) Dimension(H*W*D) 179*218*78mm / 7.0*8½*3.0 inch ** Order Information Delta Part Number IEC320 /C6 Inlet Din 7pins Connector Pins Assignment DC UPS 1232 Unit AC Power Cord Options USA (NEMA 5-15P) (8 ft) UK (BS1363) (6 ft) FR/GE (CEE 7/7) (6 ft) AU (AZ/NZS3112 ) (6 ft) GES320W12V1001 3090228102 3090233300 3090232700 3090233400 * The specification selection of input power cord may vary in different countries. ** Design and specifications are subject to change without notice. www.deltaww.com 39 Section 2 Huandong Road, Shanhua Township, Tainan County 74144, Taiwan,R.O.C. http://www.deltaww.com TEL 886-6-5056565 FAX 886-6-5051919

Uninterruptible Power Supply (DUPS-1232A) Main Features Up to 32W Output, under 38W for 10 minutes. User-friendly interface - Dry Contact Communication. Wide input voltage range - 90~264Vac. Wall Mount (horizontal or vertical) design for easy Installation. Applications (Backup power Supply DC UPS) Optical Network Terminal (ONT)-GPON & BPON Asynchronous Digital Subscriber Line (ADSL) WiMax, Residential Gateway (RG) and other CPE fiber equipments. Over the past couple of years, there has been a revolution in telecommunications technology. That is the Fiber Terminal equipments associated with the FTTx technology. FTTx is the access network infrastructure that enables full triple play to deliver voice, data and video for the connected home or business. FTTx changes the way we live, work and play. Moreover, FTTx not only needs backup power to prevent utility power failure, but also supports making emergency calls (Ex: 911) for help. Delta DUPS-1232A is a specified backup power system designed to meet the requirements for basic ONT, signal family unit SFU and power on FTTx applications. The power system integrated AC/DC circuit, lightning protect device and battery backup power (use of 12V/ 7Ah battery) into one compact enclosures. It provides the output of 32W (+12V/ 2.7 A DC output) with features of wide input voltage range and wide ambient environment.it is suitable for FTTx, xdsl, RG and Wimax applications.

Technical Specifications(DUPS-1232A)(GES320W12V3001) Normal Mode- Input Input Frequency Input Surge Normal Mode- Output Output Voltage Efficiency Backup Mode- Output 13.5 ± 5% Vdc Noise: 200 mv Peak -Peak 79% @ 120/230Vac Full Load (With Full Battery Capacity) Output Voltage 10 ~ 20 ± 5% Vdc Noise: 200 mv Peak-Peak Efficiency @Full Load 90 % Backup Time - 32 W load 1.8hrs - 8 W load 8.0hrs Auxiliary Power Information (Use of Alkaline Battery) Coax Jack connector. Dimension (OD: 3.8 mm / ID: 1.3mm) Battery Information Battery Type Battery Charger Voltage@25ºC Battery Shutdown Voltage 90~264Vac 47~70Hz NEBS GR1089 issue 4 (6kV) 12.5 ~ 20Vdc VRLA 12V/7Ah (or 7.2Ah) 13.6 ± 3% Vdc 10.5 ± 3% Vdc Unit Output Short Circuit Output Overload Output Overvoltage Shutdown @ Non-Latch 3.5A ± 10 % Shutdown @ Non-Latch >25 ± 5%V@Transfer to battery until 10.5V shutdown. LED Indicator Information AC Power Green LED (1) Light Battery Backup Mode / Low Battery Green LED (2) Light / Flash Battery Missing Red LED Green LED (3) Light (4) Light Interface Signal Information On Battery Open @power is being taken from the battery Open @ the battery fails self-test Battery Missing Open @ the battery is missing or open circuit. Battery Low Regulatory Approvals Safety Agency EMC Environment Operating Temperature Operating Humidity Storage Temperature Storage Humidity Altitude Physical Information Input Inlet Open @ the battery is near ~ 45% capacity. UL 60950-1, CAN / CSA-C22.2 No. 60950-1,IEC 60950-1, EN 60950-1,CB,NEBS Level3 FCC Part 15 Class B, CE EN55022(CISPR 22) Class B, C-Tick (AS / NZS CISPR 22) Class B, EN 300386-1 Class B 0 ~ +10000 Feet IEC320 / C6 3-prong Audible Alarm Information Backup Mode 1 time / 1 beep (on : 1 second) Output Connector (Accept #16~ 26 AWG) 3.5mm removable, 7pins screw terminal connector Low Battery 4 beeps / 1 min (on : 0.5 second) Weight@ without Battery 0.9Kg /2.01lbs 1 beep / 15 min (on : 0.5 second) Dimension(H*W*D) 190*260*80.4mm / 7½*10¼*3¼ inch IEC320 /C6 Inlet Din 7pins Connector Pins Assignment ** Order Information DC UPS 1232A Unit AC Power Cord Options USA (NEMA 5-15P) (8 ft) UK (BS1363) (6 ft) FR/GE (CEE 7/7) (6 ft) AU (AZ/NZS3112 ) (6 ft) Delta Part Number GES320W12V3001 3090228102 3090233300 3090232700 3090233400 * The specification selection of input power cord may vary in different countries. ** Design and specifications are subject to change without notice. www.deltaww.com 39 Section 2 Huandong Road, Shanhua Township, Tainan County 74144, Taiwan,R.O.C. http://www.deltaww.com TEL 886-6-5056565 FAX 886-6-5051919