Motors Damage Curves

Similar documents
Published for electrical engineers by EPOWERENGINEERING and available at The ABC s of Overcurrent Coordination

Alternating Current Motors in Detail

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219

Motor Protection Fundamentals. Motor Protection - Agenda

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

DOCUMENTATION PACKAGE

DOCUMENTATION PACKAGE

MAIN ELECTRIC MOTOR 900 HP 4000 V 60 HZ MAKE: RELIANCE ELECTRIC

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Low Voltage Fuses For Motor Protection

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE VOLT CONNECTION(S). IF OTHER VOLTAGE CONNECTIONS ARE AVAILABLE, THE AMPERES WILL

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

Modifiable TITAN Horizontal Motors Accessories and Modifications

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

Weather Protected Type II (WPII) Totally Enclosed Fan-Cooled (TEFC) Totally Enclosed Air to Air Cooled (TEAAC)

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

MAX-VH. Vertical Hollow Shaft Motors

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1

Slip-ring motors MAR Series

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SECTION MOTOR REQUIREMENTS for HVAC

PIP ELEMT01 Guidelines for Selecting IEEE and API Standards for AC Motors 250 HP (185 kw) and Larger

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754

Severe Duty is Standard with WEG W22 motors

Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1

Single Phase Poultry Fan Motor, Standard Efficiency,TEAO, Squirrel Cage Rotor

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

Industrial Machinery PU LARGE MOTORS

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

Product Information Packet EM4313T 75HP,3550RPM,3PH,60HZ,365TS,1464M,TEFC,F

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

MODELING AND TESTING OF DIGITAL PROTECTION REALY FOR AN INDUCTION MOTOR. Sungmin Cho

FAN ENGINEERING. Motor Standards for the Chemical Process Industry

FAN ENGINEERING. Motor Standards for the Chemical Process Industry

CROMPTON GREAVES LTD.

Just Name Your Need. AMG and AMZ Synchronous Machines PRODUCT REVIEW

EXPERIMENT 19. Starting and Synchronizing Synchronous Machines PURPOSE: BRIEFING: To discover the method of starting synchronous motors.

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211

Protective Device Coordination ETAP Star

4.1. Manufacturing field F2 Preformed and field coil windings

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

Brake Motors Aluminium Frame Improved Efficiency EFF2

DATASHEET FOR INDUCTION MOTOR

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

Powerful + Efficient + Reliable

Full Voltage Starting (Number of Starts):

SECTION MOTOR CONTROL

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

ECET Industrial Motor Control. NEMA Ratings. National Electrical Manufacturers Association

Recommended Procedures

Cutting-edge technologies backed by a century of experience

SECTION ELECTRIC MOTORS

Suitability of Direct Drive Motor Technology as applied to ACC s. Bill Martin & Tom Weinandy

Series Motor Protection

NEMA & IEC Product Features and Benefits

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

DRIP-PROOF SPLASH-PROOF WOUND ROTOR HORIZONTAL AND VERTICAL INDUCTION MOTORS. Custom designed. 100% U.S. manufactured

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

MAX-E1 HIGH EFFICIENCY. Severe Duty

SUPER-MAX INDUCTION MOTOR

MTE AC Line / Load Reactors Price book

FAN ENGINEERING. Integral AC Motor Selection and Application Guide For Fans

GENERAL Proposal 1) Bid Sheet REPLACE -Section Page 12 & 13 of Section 0300 BID SHEET with the attached revised document.

BRUSHLESS EXCITERS FOR TURBINE GENERATORS

Product Information Packet ECP84400T-4 100HP,1785RPM,3PH,60HZ,405T,A40064M,TEFC

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Motor Basics AGSM 325 Motors vs Engines

Unit Substation Transformers 5 and 15 KV Class

Table 1. Lubrication Guide

Start Slide: EPG Electric Power Generation

Product Information Packet ECP84404T-4 75HP,1185RPM,3PH,60HZ,405T,A4072M,TEFC,F

Pricing Guide for Horizontal Above NEMA Motors ANSP , Rev.0 above NEMA

Product Information Packet ECP4410T-4 125HP,1785RPM,3PH,60HZ,444T,A44076M,TEFC

IP66 GSW GEAR BOX MOTOR SERIES

BMS Series. DC Brushless Torque Motors. Slotless, brushless stator design provides zerocogging torque for unsurpassed velocity control

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Features and Benefits

Product Information Packet ECP4406T-4 150HP,1785RPM,3PH,60HZ,445T,A4488M,TEFC

Product Information Packet ECP84314T-4 60HP,1780RPM,3PH,60HZ,364T,TEFC,FOOT

NORDIC-PREMIUM EFFICIENCY

UNDERSTANDING LOW VOLTAGE SQUIRREL CAGE INDUCTION MOTORS

Transcription:

Motors Damage Curves The information presented in this application guide is for review, approval, interpretation and application by a registered professional engineer only. SKM disclaims any responsibility and liability resulting from the use and interpretation of this information. Reproduction of this material is permitted provided proper acknowledgement is given to SKM Systems Analysis Inc. Purpose The purpose of this guide is to provide basic information about motor thermal limit curves and characteristic landmarks necessary for plotting on time-current curves, for the purpose of equipment overcurrent protection. IEEE Std 620 defines the presentation of thermal limit curves for squirrel-cage induction motors. No comparable standard exits for wound-rotor induction or synchronous motors. IEEE Std C37.96 covers protection methods for squirrel-cage induction, woundrotor induction and synchronous motors. It also defines the running thermal capability, thermal limit curve, accelerating thermal limit and locked rotor thermal limit similar to IEEE Std 620. Presentation of Thermal Limit Curves Machine running overload, accelerating thermal limit and locked rotor thermal limit curves may be provided as a single continuous curve or a set of discontinuous curves. Two sets of thermal limit curves are typically provided. The first set with the machine initially at ambient (cold) temperature followed by a second set with the machine initially at rated operating (hot) temperature. Full Load Amps (FLA) Rated continuous current carrying capacity of a motor at a referenced ambient temperature and allowable temperature rise, see table 1. Page(1)

Table 1 Motor Temperature Ratings Max Amb. Hot Spot Rise Rise Total Rise Insul. Insul. 40 C 5 C Class A 60 C 105 C Class A 105 C 40 C 10 C Class B 80 C 130 C Class B 130 C 40 C 10 C Class F 105 C 155 C Class F 155 C 40 C 15 C Class H 125 C 180 C Class H 180 C 40 C 10 C Class B 80 C 130 C Class F 155 C 40 C 15 C Class F 105 C 160 C Class H 180 C Accelerating Curve The accelerating curve represents the starting and running ampere characteristic curve of a motor for a given load inertia (Wk2), load torque-speed curve, and starting voltage. Typically, accelerating curves are provided at the motor rated voltage (100%) and the NEMA standard minimum rated locked rotor voltage (90%). If the application requires a lower locked rotor voltage the user must specify the new voltage and the manufacturer must provide the corresponding accelerating curve. Running Overload Curve The running overload (stator damage) curve shall represent the motor thermal capability from rated full-load current to the current at approximately the breakdown torque while running. This curve is not meant as an indication of continuous overload capability, and should never be used to schedule running overload operations. Repeated operation up to and beyond the running overload curve will reduce insulation life. Running overload curves are typically provided for medium-voltage motors. Accelerating Thermal Limit Curve The accelerating thermal limit curve shall represent the motor thermal capability from locked rotor to the current at approximately the breakdown torque while accelerating. Accelerating curves are typically provided for medium-voltage motors. If a motor is required to accelerate and run in both the forward and reverse direction, separate accelerating curves for the forward and reverse direction may be required. Safe Stall Point Page(2)

The safe stall (rotor damage) point represents the maximum time the machine can stay locked without damage at a referenced starting voltage. Safe stall points are typically provided for low-voltage motors. NEMA MG-1 requires motors 500HP and below with a rated voltage not exceeding 1kV shall be capable of withstanding locked-rotor current for not less than 12 seconds when the motor is initially at normal operating temperatures. Locked Rotor Thermal Limit Curve The locked rotor thermal limit (rotor damage) curve shall represent the maximum time the machine can stay locked without damage. The curve is constructed by drawing a line through the rated safe stall points given for a series of referenced starting voltages. Locked rotor curves are typically provided for medium-voltage motors. Example 1 Plot the characteristic landmarks for a 1500HP, 4000V, 2P, 187A, WPII induction motor. Solution The submittal package from the motor manufacturer lists the following starting and thermal limit characteristics for a machine initially at rated operating (hot) temperature. Stator Damage Points: Current (%) Time 1.55 1000.0 1.80 400.0 2.82 100.0 Rotor Damage Points at 100% Voltage: Current (%) Time Page(3)

5.2 30.0 6.0 25.0 6.6 12.0 Rotor Damage Points at 90% Voltage: Rotor Damage Points at 80% Voltage: Accelerating Times: The results are plotted in figure 1. Current (%) Time 3.9 50.0 5.2 30.0 5.6 15.0 Current (%) Time 3.0 85.0 3.9 50.0 4.2 25.0 Voltage (%) Time 100 6.0 90 8.4 80 14.0 Page(4)

Fig. 1 NEMA MV motor TCC landmarks Example 2 Plot the characteristic landmarks for a 40HP, 460V, 4P, 1.15 SF, TEFC induction motor. Solution The manufacturer s data sheet lists the following motor performance characteristics. FLA = 49.4 LRA = 275.3 Acceleration time with maximum load inertia at 100% volts = 14.0 seconds Page(5)

Hot safe stall time at 100% volts = 44.0 seconds The results are plotted in figure 2. Fig. 2 NEMA LV motor TCC landmarks Page(6)

References Other Application Guides offered by SKM Systems Analysis at www.skm.com The latest revision of: IEEE Std 242, IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) IEEE Std 620, IEEE Guide for the Presentation of Thermal Limit Curves for Squirrel Cage Induction Machines IEEE Std C37.96, IEEE Guide for AC Motor Protection NEMA MG-1, Motors and Generators Insulation Class Insulating Materials Maximum Insulating Materials Temperature Y 90 C Cotton, silk, paper, wood, cellulose, fibre without impregnation or oil-immersion A 105 C Class Y impregnated with natural resins, cellulose esters, insulating oils, etc., also laminated wood, varnished paper Hybrid A 110 C Insuldur Insulation Kraft paper with epoxy binders activated under pressure E 120 C Synthetic-resin enamels, cotton and paper Laminates with formaldehyde bonding B 130 C Mica, glass fibre, asbestos, etc., with suitable bonding substance; built-up mica, glass-fibre and asbestos laminates F 155 C The materials of Class B with more thermallyresistant bonding materials H 180 C Glass-fibre and asbestos materials, and built-up mica, with appropriate Silicone resins C >180 C Mica, ceramics, glass, quartz, and asbestos without binders or with silicone resins of superior thermal stability Hybrid H 220 C NOMEX insulation, varnish dipped and vacuum pressure impregnated (VPI) Page(7)