Very high efficiency up to 93% Adjustable output voltage

Similar documents
Typical efficiency up to 93 % Up to 4 kw power (max. 16 kw) Liquid or convection cooling. CAN bus serial interface. Adjustable output voltage

Liquid or convection cooled models available CAN bus serial interface

Series AM1P-Z 1 Watt DC-DC Converter

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

Series AM2D-Z 2 Watt DC-DC Converter

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

RP40- _FR/ Package (4) CTRL Logic (3)

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

GB60S 60W Single Output General Purpose Series

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Distributed power architectures Telecommunications equipment LAN/WAN applications Data processing Industrial applications

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Package (3) CTRL Logic (2)

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

C B. Operating up to 5000m altitude 5 year product warranty Models

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Series AM2S-Z 2 Watt DC-DC Converter

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Load (2) Single or Dual

Features. Description. Table of Contents

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

(typ.) (Range) Load

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

S24SP series 40W Single Output DC/DC Converter

Series AM2D-Z 2 Watt DC-DC Converter

WATT MBH SERIES DC/DC CONVERTERS

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

RCD15W Series PART NUMBER STRUCTURE

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

S24SP15004 series 60W Single Output DC/DC Converter

Series AM2F-Z 2 Watt DC-DC Converter

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

North America Asia-Pacific Europe, Middle East

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

Description. Operational Features. Mechanical Features. Safety & EMC. Control Features. Protection Features

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series

IND065BLV Hornet: Non-Isolated DC-DC Voltage Regulator Modules

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

OSR03-24 S 05 A Series Name Input Output Output Assembly Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Volant NEA/NEF010 Series

Industrial Power Supplies

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

(typ.) (Range) ±18 330# 89 MPW MPW

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

PG02S Series 2W DC/DC CONVERTER, SIP-Package

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

Series AM2D-RZ 2 Watt DC-DC Converter

Packaging (1) Package

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Isolated and rugged 24 Vdc power for battery powered electronic control systems on rail equipment

FEATURES. Input Voltage (VDC) 3.3

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

NES50-48 : High efficient DC/DC converters

DCMCW60 SERIES FEATURES

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

UL Certified RP30-FW

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

R-78AA-0.5 INNOLINE. Features. 0.5 AMP SMD Single Output. Derating-Graph (Ambient Temperature) DC/DC-Converter

Series AM1G-NZ 1 Watt DC-DC Converter

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

FW250R1 and FW300R1 Power Modules: dc-dc Converters: 36 Vdc to 75 Vdc Input, 28 Vdc Output; 250 W to 300 W

STRIDER ESSENTIAL SERIES ST50F-ESB ST40F-ESB Power for everything you need

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A

Transcription:

The Bel Power Solutions 700DNC40-24-xG is a 4 kw DC/DC converter that creates DC voltages in hybrid and electric vehicles necessary to power low voltage accessories. Liquid or convection cooled DC/DC converter operates at input voltages from 400 to 850 VDC and power range up to 4000 W / 3300 W (liquid / convection cooled models). Very high efficiency up to 93% Adjustable output voltage Input voltage range: 400-850 VDC Up to 4 kw power Over temperature, output overvoltage and overcurrent protection, input and output reverse polarity protection Full galvanic isolation between input and output Liquid or convection cooled models available CAN bus serial interface Protection degree IP65 and IP67 E-MARK E12*10R00-10R05*13669 North America +1.866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East

MODEL 700DNC40-24-8G 700DNC40-24-CG 700DNC40-CON-KIT-8G 700DNC40-CON-KIT-9G DESCRIPTION Liquid Cooled Model Convection Cooled Model Mating connectors kit signal connector housing and pins, HV connector assembled with 3 m cable Mating connectors kit - housing and pins Input Voltage 400 700 850 VDC Input Current 11 ADC Efficiency @ Vin = 700 VDC, Vo = 28 V, Io = 120 A 92 % Input Line Interruption Converter shutdown 390 VDC Input Capacitance 30 μf Inrush Current External pre-charging circuit required Output Voltage Vo to be trimmed via CAN BUS, 10 bit resolution 22 28 32 VDC Output Current Output Power @ 28 VDC Line Regulation Vinmin - Vinmax, @ 60 A, Tamb = 45 C - 0.2 + 0.2 VDC Output Voltage Set Point @ 60 A, Tcoolant = 25 C 27.9 28 28.1 VDC Thermal Drift -0.1 +0.1 %/ C Periodic and Random Deviation Transient Response @ 28 VDC / Nominal load (Differential Mode 20 MHz) CAN high / low (Differential Mode 20 MHz) Load step 1: 10 to 50 % and back Load step 2: 50 to 100 % and back Voltage over/under shoot: Response time within 1 % of VoSET: 143 120 4000 3300 460 * 300 * -1400 +1400 1000 Turn-on Overshoot Vonom, <100 ms 5 % Redundant Parallel Operation Up to 4 converters operating in parallel 16 kw Remote Sense Cable Drop (V) @ Maximum Load 0.5 V Turn-On Delay Rise time (Cext = 0 μf) Power-on-delay (From applying DC input voltage to Vo = 90 %) Power-on-time from PS_WAKE UP (From PS_WAKE UP ON to Vo = 90% of nom) Turn-Off Timing PS_WAKEUP delay; (monotonic Vo fall) 0 100 ms Capacitive Load @ 28 VDC 0 7200 μf * With external capacitors 47uF (Electrolytic cap) & 1uF (X7R Ceramic cap) connected to measuring point. 200 1 3 ADC W mvp-p mv μs ms s s

Output Over-Current Protection Constant current Output Over-Voltage Protection Latch type, max. OV duration 1 ms 32 34 V Output Under-Voltage Protection Max. UV duration 1 s, than hiccup 18 20 V Over-Temperature Protection Input and Output Reverse Polarity Protection Converter shutdown Protective elements connected in series 146 123 80 50 C Input Fuse Protection DC Input: internal primary fuse, safety approved 20 A Input Low Line Protection Turn ON threshold Turn OFF threshold Input Overvoltage Protection Recovery: Vin re-cycling or PS_WAKEUP 855 870 V 390 370 400 380 410 390 A VDC PARAMETER DESCRIPTION / CONDITION CAN BUS SAE J1939 250 kbit/s or 500 kbit/s available Remote sense signals Sense positive (+24 V SENSE) Sense negative (-24 V SENSE) 0.5 V compensation Address bits Internally pulled up to LOGIC HIGH (3.3V 100kohm) Adr. 0 Adr. 1 PS_WAKEUP Logic input signal LV BAT VOLTAGE HVIL function HVIL pin shorted internally Part of HV connector CAN speed selection Logic Low 250kBit/s CAN_SPEED Internally pulled up to LOGIC HIGH (3.3V 100kohm) Logic High 500kBit/s PARAMETER DESCRIPTION / CONDITION CRITERION Safety certification Report number: E12*10R00-10R05*13669 E-MARK Basic: 3000 VDC Input-to-Protective Earth Insulation Basic: 3000 VDC Input-to-Output Radiated Emission UN ECE R10 4th Edition ESA level Electrostatic Discharge IEC 61000-4-2 Performance Criterion B Radiated Electromagnetic Field IEC 61000-4-3 (10 V/m), Performance Criterion B SAE J1113/21(100V/m) Class B Electrical Fast Transient IEC 61000-4-4, Level 2 (+/-2 kv, 2.5 khz) Performance Criterion B ISO 7637-2; ISO 7637-3, ISO 16750-2 RF Conducted Immunity Level 3 (10 V, 0.15 80 MHz, AM 80%, 1kHz) Performance Criterion A RF Disturbances Immunity SAE J1113-41 Class A ISO11452-4 (1-400 MHz, 60 ma) Class B Altitude Operating Temperature Operating: 62 kpa absolute pressure 3600 m Non-Operating:18.6 kpa absolute pressure 12200 T_coolant with no derating -40 +70 : T_amb @ full load, no power derating -40 +85 C : T_amb with no power derating -40 +45 Storage Temperature -40 +95 C Humidity Shock Vibration SAE J1455 SAE J1455 SAE J1455, MIL-STD-202G

PARAMETER DESCRIPTION / CONDITION MANUFACTURER MPN Input Connector (IN) High voltage connecter with HVIL function TYCO 2141272-1; KEY A Output Connector (OUT) Male dual terminal thread M8 CAN BUS and Signal Interface (CTRL) Panel mounted TYCO 776276-1 PARAMETER Maximum Inlet Coolant Temperature Coolant Medium/Mixture Min. Coolant Flow Max. coolant pressure Max. pressure drop DESCRIPTION / CONDITION +70 C 50/50 Propylene or Ethylene Glycol/Water 0.0208l/s (0.33GPM) 20psi 1psi Signal Connector Pin Description Signal Connector Output Connector Input Connector PIN SIGNAL DESCRIPTION 1 PS_WAKEUP 2 ADR0 3 ADR1 4 CAN_SPEED 5 CAN_H 6 CAN_L 7 +SENSE 8 -SENSE PARAMETER LIQUID COOLED MODEL CONVECTION COOLED MODEL Dimensions (W x H x D) 270 x 113.3 x 343 mm 350 x 187.7 x 343 mm Weight 11 kg 22 kg Enclosure IP65 and IP67

Mechanical Drawings - Liquid Cooled Model TYCO P/N 776276-1 GORE VENT TYCO P/N 2141272-1 343 ±2 103.3 ±2. 270 ±2 234 ±0.5 10 30 18 ±0.5 M8x16mm DPT. MAX. TORQUE 20Nm O 33 50 ±0.5 4x ELASTOMER DAMPERS 2x MALE STUD CONNECTOR THREAD 1-14UNS WITH O-RING O 9 4x 262 ±0.5

Mechanical Drawings - Convection Cooled Model 343 ±2 187.7 ±2 350 ±2.. O 8.5 4x 160 ±1 330 ±1 NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.