Method-Specific Sample Preparation for EPH Analysis

Similar documents
Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges

State of Texas UST Monitoring visit us online at The latest TNRCC 1005/1006 UST methods used by Texas.

State of Alaska UST Monitoring

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Analysis of Petroleum Fractions by ASTM D2887

The next level of True Blue Performance

Underground Storage Tanks Compliance Monitoring with Restek Analytical Reference Materials

LUFT/LUST Petroleum Standards State Methods

Determination of PAH Compounds from Aqueous Samples Using a Non-Halogenated Extraction Solvent and Atlantic C18 Disks

High-Performing Restek PAL SPME Fibers

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut

Set Your Sights on Superior Performance

Set Your Sights on Superior Performance

Application Note. Abstract. Authors. Environmental Analysis

TEKLAB, INC ANALYTICAL QC SUMMARY REPORT. CLIENT: Kelron Environmental Work Order: Project: CHMGP/ Page 1 of 6.

Emissions Characteristics of Volatile and Semi-volatile Organic Compounds and Polynuclear Aromatic Hydrocarbons (PAHs) from Hot and Warm Mix Asphalts

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

Underground Storage Tank Monitoring State Of California visit us online at

Hydrocarbon standards for GC analysis 2016

New Integrated GC Guard Columns for Built-In Protection

Introducing Restek s most inert liner The Sky Inlet Liner! Chromatography Products.

Method Development for Capillary GC Systems. Slide 1

Techniques for Improving the Reproducibility of GC Analysis

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

SSENTIALS RESTEK. GC Column Connectors. The Power of HILIC and RP Modes in One LC Column. Pure Chromatography. A Full Selection of ALSO IN THIS ISSUE:

5 PHASE GC COLUMNS DISCOVER NEW OPTIONS. Phenomenex I Web:

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

APPLICATION OF SOLID PHASE MICROEXTRACTION (SPME) IN PROFILING HYDROCARBONS IN OIL SPILL CASES

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

CONSTITUTION OF COAL TAR PITCH AND ITS EFFECT ON PROPERTIES

Agilent 9000 Intuvo GC Applications. Matthew Giardina, Ph.D. James McCurry, Ph.D. Rebecca Veeneman, Ph. D.

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

Technical Procedure for Gas Chromatography (GC-FID)

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

Replacement Parts & Accessories for ASE Systems

ZB-5ms GC Columns. Aromatic Compounds

EPA Method 625: Determination of Bases, Neutrals and Acids by Solid Phase Extraction and GC/MS Detection

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

Agilent Multimode Inlet for Gas Chromatography

New Developments in Ionic Liquid GC Stationary Phases

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Practical Steps in GC Troubleshooting

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

EPA 625: Base, Neutral, Acid Semivolatiles in Municipal and Industrial Waste Water by Solid Phase Extraction

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Bio-Aquatic Testing 2501 Mayes Rd Suite 100 Carrollton, TX (972)

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Applicant: GUANGDONG XIN YU TECHNOLOGY INDUSTRIAL Date: Mar 21, 2018 CO.,LTD. LAI MEI INDUSTRIAL ZONE, CHENGHAI DISTRICT, SHAN TOU, GUANGDONG, CHINA

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

On-Road Emission Rates of PAH and n-alkane Compounds from Heavy-Duty Diesel Vehicles

Characterization of Tiki Torch Fuels

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Table C 15. TAC Emissions Summary and Ambient Air Impact Concentrations. FCA Mack Avenue Assembly Plant Update February 2019

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

ASTM D 6730 Detailed Hydrocarbon Analysis

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

XLB. 1-MS Accent. 5-MS Accent. MACHEREY-NAGEL

Setting up SilFlow for BackFlush in your GC

CHROMATOGRAPHIC SPECIALTIES INC.

Diffusion Results for Rigid Porous Polyethylene Samplers

From Helium to Hydrogen: GC-MS Case Study on SVOCs in Water

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

R.A.M. Large Opening Vials, 12x32mm, 9mm Neck Finish

Reference Standards Petroleum & Petrochemical

Using the PSD for Backflushing on the Agilent 8890 GC System

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Operation and Applications of Differential Flow Modulation

C2, C3, C4 Monomer Analysis

GC Inlets. An Overview. Simon Jones GC Applications Engineer

Hydrocarbon Analysis using Sitelab UVF for DENR UST Program

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Shimadzu GCs. Genuine Restek Replacement Parts

Great Savings! Introducing NEW 3000 Centrifuge for QuEChERS. Restek Electronic Leak Detector. Subscribe online!

Agilent GCs. Genuine Restek Replacement Parts. More Parts & Accessories for More GC Systems. Innovative Chromatography Products

NEW? REFERENCE STANDARDS PETROLEUM & PETROCHEMICAL MATERIALS. What s. look for this circle

REFINED. Simulated Distillation Bonded PLOT Columns Permanent Gases Visit us at

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Supporting Information for. Diesel Particle Filter and Fuel Effects on Heavy-Duty Diesel Engine Emissions

QuEChERS. What s New! Great Savings! 10-pk. FREE! Buy one 10-pk. of Dual Vespel Ring Inlet Seals at 25% off & Receive a 2nd

Characterization and Source Identification of an Unknown Spilled Oil Using Fingerprinting Techniques by GC MS and GC FID

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

CrossLab. Supplies for PerkinElmer GC Systems. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Your GC Analysis More. and Robust. Mark Sinnott. May 11, Agilent Restricted

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer

SPE Manifolds and Accessories

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

CrossLab. Supplies for Thermo Scientific GC Systems. work for you non-agilent GCs. Put Agilent innovation and quality to. Agilent

Transcription:

Method-Specific Sample Preparation for EPH Analysis Resprep SPE Cartridges for Complete Extractable Petroleum Hydrocarbon Fractionation Full separation between fractions. Guaranteed low background level. Superior lot-to-lot reproducibility. www.restek.com

Resprep EPH Fractionation SPE Cartridges Method-specific performance for extractable petroleum hydrocarbon (EPH) analysis of soil and water samples. Complete separation of aliphatic and aromatic compounds into distinct fractions. Guaranteed background level under the strict reporting limits of MA and NJ EPH methods. Superior lot-to-lot reproducibility and storage stability ensured by rigorous QC testing and moisture-resistant packaging. Resprep EPH fractionation SPE cartridges from Restek are manufactured in a strictly controlled environment with the simple goal of giving you consistent results every day, every time. Turn to Resprep cartridges for easy, reproducible, and guaranteed extractable petroleum hydrocarbon analysis. Order yours today at www.restek.com/resprep Figure 1: Resprep EPH SPE cartridges offer consistent and complete separation between aliphatic and aromatic compounds from one lot to the next. A representative subset of compounds is shown here (40+ compounds were analyzed in total) to clearly illustrate the separation between fractions and the lack of breakthrough in every lot we produce. Resprep EPH Fractionation SPE Cartridge, Lot 1 Resprep EPH Fractionation SPE Cartridge, Lot 3 Hexane / Aliphatic Fraction Dichloromethane / Aromatic Fraction Hexane / Aliphatic Fraction Dichloromethane / Aromatic Fraction 0 1 2 3 4 5 6 7 8 9 1011121314 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Elution Volume (ml) 0 1 2 3 4 5 6 7 8 9 1011121314 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Elution Volume (ml) Resprep EPH Fractionation SPE Cartridge, Lot 2 C9 Chlorooctadecane Pyrene Hexane / Aliphatic Fraction Dichloromethane / Aromatic Fraction C20 C30 Trimethylbenzene Naphthalene Dibenz(a,h)anthracene o-terphenyl C40 2-Bromonaphthalene No guesswork, no worries. Detailed, step-by-step instructions and a complete certificate of analysis are included with every 15-pack of Resprep EPH cartridges. 0 1 2 3 4 5 6 7 8 9 1011121314 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Elution Volume (ml) 2 www.restek.com

Table I: Recovery data (n = 3) for Resprep EPH SPE cartridges. Again, 40+ compounds were analyzed; shown here are the compounds most critical to method requirements. Aliphatic Fraction Compound Concentration (ppm) Function Average % Recovery %RSD C9 200 Most-retained aliphatic 109.1 2.1% Chlorooctadecane 200 Surrogate 107.0 0.6% C28 4,000 Aliphatic loading capacity probe 109.2 1.0% C40 200 Least-retained aliphatic 106.8 0.6% Aromatic Fraction Compound Concentration (ppm) Function Average % Recovery %RSD Trimethylbenzene 200 Least-retained aromatic 85.3 6.7% Naphthalene 200 Breakthrough probe 86.6 6.8% 2-Methylnaphthalene 200 Breakthrough probe 86.6 6.7% 2-Fluorobiphenyl 200 Surrogate 86.4 6.7% 2-Bromonaphthalene 200 Surrogate 86.2 6.7% Phenanthrene 4,000 Aromatic loading capacity probe 86.2 6.7% o-terphenyl 200 Surrogate 86.2 6.7% Dibenzo(a,h)anthracene 200 Most-retained aromatic 82.2 7.7% Figure 2: Storage stability is enhanced by new, moisture-resistant packaging that prevents ambient moisture from reaching your SPE cartridge and helps ensure outstanding performance. Moisture Content after Storage in 80% Relative Humidity Moisture (%) 5.00 4.50 4.00 3.50 3.00 2.50 2.00 1.50 1.00 0.50 0.00 0 1 2 3 4 6 8 10 12 16 20 24 Storage Time (weeks) www.restek.com 3

Figure 3: Restek guarantees a background level in each fraction of less than half the strict reporting limits of MA and NJ EPH methods. EPH Silica Cartridge Background Extraction Aliphatic Fraction on Rxi-5ms Conc. Peaks t R (min) (µg/ml) 1. 1-Chlorooctadecane 15.679 5 Region 1 Total extracted background = 8.2 ppm Column Rxi-5ms, 30 m, 0.32 mm ID, 0.25 µm (cat.# 13424) Sample MA EPH surrogate spike mix (cat.# 31479) Conc.: 5 µg/ml Injection Inj. Vol.: 1 µl splitless (hold 1 min) Liner: Restek Premium 4.0 mm ID cyclo double taper inlet liner (cat.# 23310) Inj. Temp.: 300 C Purge Flow: 50 ml/min Oven Oven Temp.: 40 C (hold 1 min) to 300 C at 12 C/min to 330 C at 6 C/min Carrier Gas He, constant flow 1-Chlorooctadecane at 5 ppm Flow Rate.: Linear Velocity: 2 ml/min 41.0 cm/sec @ 40 C Dead Time: 1.12 min @ 40 C Detector FID @ 330 C Make-up Gas Flow Rate: 45 ml/min Make-up Gas Type: N₂ Hydrogen flow: 40 ml/min Air flow: 450 ml/min Data Rate: 50 Hz Instrument Agilent 7890B GC Notes The area of the surrogate peak was excluded from the calculated total extracted background value for Region 2. Region 2 Total extracted background = 11.5 ppm 5 7.5 10 12.5 15 17.5 20 22.5 25 Time (min) GC_EV1437 EPH Silica Cartridge Background Extraction Aromatic Fraction on Rxi-5ms Conc. Peaks t R (min) (µg/ml) 1. o-terphenyl 14.177 5 o-terphenyl at 5 ppm Region 1 Total extracted background = 14.2 ppm Region 2 Total extracted background = 13.1 ppm 5 7.5 10 12.5 15 17.5 20 22.5 25 Time (min) GC_EV1438 4 www.restek.com

Product Listing Resprep EPH Fractionation SPE Cartridge Method-specific performance for extractable petroleum hydrocarbon (EPH) analysis of soil and water samples. Complete separation of aliphatic and aromatic compounds into distinct fractions. Guaranteed background level under the strict reporting limits of MA and NJ EPH methods. Superior lot-to-lot reproducibility and storage stability ensured by rigorous QC testing and moisture-resistant packaging. Description Volume qty. cat.# Resprep EPH Fractionation SPE Cartridge 25 ml, 5 g 15-pk. 25859 No-risk, no-obligation trial. Free samples of Resprep solid phase extraction (SPE) tubes are available. Contact us or your local Restek representative to request yours: www.restek.com/contact-us Resprep 12- or 24-Port SPE Manifolds Use with any standard male luer end SPE cartridges. Inert, PTFE sample guides reduce cross-contamination and carryover. Flexible sample collection rack will accommodate a variety of receiving vessels. Quick vacuum-release valve for better system control. Individual valves allow vacuum control for each cartridge, improving reproducibility. Description qty. cat.# Complete Resprep SPE Manifold, 12-Port (Includes: glass basin with built-in vacuum regulator (1); polypropylene lid with 12 individual control valves (1); 12-position collection rack (1); PTFE sample guides (12); and kit 26077 waste container (1).) Complete Resprep SPE Manifold, 24-Port (Includes: glass basin with built-in vacuum regulator (1); polypropylene lid with 24 individual control valves (1); 24-position collection rack (1); and PTFE sample guides (24).) kit 26080 Resprep Manifold Replacement Parts Description qty. cat.# Replacement Waste Container, 12-Port ea. 24014 Replacement Vacuum Valve and Gauge Assembly ea. 24008 Glass Vacuum Chamber w/gauge & valve for Resprep manifolds, 6 or 12-Port ea. 25991 Collection Rack Collection Rack, 12-Port ea. 26079 Collection Rack, 24-Port ea. 26082 Manifold Lid Replacement Manifold Lid (sample guides not included), 12-Port ea. 26078 Replacement Manifold Lid (sample guides not included), 24-Port ea. 26081 Manifold Lid Replacement Parts Valves, 12 or 24-Port 2-pk. 26083 Valve Attachment 48-pk. 26130 Needle Attachment 48-pk. 26131 Sample Guide Needles, 12 or 24-Port 12-pk. 26084 NOTE: Replacement waste container not included in 24-port manifold kit (cat.# 26080). *Waste container (shown in tank) and top shelf for round-bottom flasks are not included in 24-port manifold kit (cat.# 26080). Resprep 12-Port SPE Manifold www.restek.com 5

Rxi-5ms Columns (fused silica) low-polarity phase; Crossbond diphenyl dimethyl polysiloxane similar phases HP-5ms SemiVolatiles, HP-5ms, HP-5msUI, DB-5, Ultra-2, CP-Sil 8 CB, ZB-5, ZB-5msi General-purpose columns for semivolatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g., Aroclor mixes), solvent impurities. Most inert column on the market. Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity. Temperature range: -60 C to 330/350 C. Equivalent to USP G27 and G36 phases. Description temp. limits qty. cat.# 30 m, 0.32 mm ID, 0.25 µm -60 to 330/350 C ea. 13424 Si 5% O CH 3 Si CH 3 95% O 2.0 ml, 9 mm Short-Cap, Screw-Thread Vials, 12 x 32 mm Fit all 2.0 ml, 12 x 32 mm, crimp-top vial-based autosamplers. 2.0 ml, 9 mm Short-Cap, Screw-Thread Vials (vial only) Ideal for Agilent 7673, 7683, 7693 & other autosamplers that process 12 x 32 mm crimp-top vials. Description Color 100-pk. 1,000-pk. Short-Cap Vial w/white Graduated Marking Spot Amber 21142 21143 2.0 ml, 9 mm Short-Cap, Screw-Vial Closures (Polypropylene, preassembled) Cap Color Septa Material Type 100-pk. 1,000-pk. Blue PTFE/Silicone Screw-Thread 24485 24486 Choose preslit caps (available for some vials) to reduce the risk of needle bending, release vacuum from high-volume injections, and improve injection reproducibility when greater than 20% of vial volume is withdrawn. 2.0 ml, 9 mm Screw-Thread Vial Convenience Kits (Vials, Caps, & Septa) Vials packaged in a clear-lid tray. Caps with septa packaged in a plastic bag. 100-pk. 1,000-pk. Description cat.# cat.# Amber Vial w/graduated Marking Spot, 9 mm, Blue Cap PTFE/Silicone Liner 26596 26597 Crimp-top and other vials also available! Find your vial at www.restek.com/vial-selector 6 www.restek.com

NJDEP EPH 10/08 Rev. 2 Aliphatics Calibration Standard (20 components) (C9) n-nonane (111-84-2) (C10) n-decane (124-18-5) (C12) n-dodecane (112-40-3) (C14) n-tetradecane (629-59-4) (C16) n-hexadecane (544-76-3) (C18) n-octadecane (593-45-3) (C20) n-eicosane (112-95-8) (C21) n-heneicosane (629-94-7) (C22) n-docosane (629-97-0) (C24) n-tetracosane (646-31-1) (C26) n-hexacosane (630-01-3) (C28) n-octacosane (630-02-4) (C30) n-triacontane (638-68-6) (C32) n-dotriacontane (544-85-4) (C34) n-tetratriacontane (14167-59-0) (C36) n-hexatriacontane (630-06-8) (C38) n-octatriacontane (7194-85-6) (C40) n-tetracontane (4181-95-7) 2-Methylnaphthalene (91-57-6) Naphthalene (91-20-3) 2,000 µg/ml each in hexane:carbon disulfide (80:20), 1 ml/ampul cat.# 30540 (ea.) NJDEP EPH 10/08 Rev. 2 Aromatics Calibration Standard (18 components) Acenaphthene (83-32-9) Acenaphthylene (208-96-8) Anthracene (120-12-7) Benz(a)anthracene (56-55-3) Benzo(a)pyrene (50-32-8) Benzo(b)fluoranthene (205-99-2) Benzo(ghi)perylene (191-24-2) Benzo(k)fluoranthene (207-08-9) Chrysene (218-01-9) Dibenz(a,h)anthracene (53-70-3) Fluoranthene (206-44-0) Fluorene (86-73-7) Indeno(1,2,3-cd)pyrene (193-39-5) 2-Methylnaphthalene (91-57-6) Naphthalene (91-20-3) Phenanthrene (85-01-8) Pyrene (129-00-0) 1,2,3-Trimethylbenzene (526-73-8) 2,000 µg/ml each in methylene chloride, 1 ml/ampul cat.# 30541 (ea.) NJDEP EPH 10/08 Rev. 2 Aliphatics Matrix Spike Mix (18 components) (C9) n-nonane (111-84-2) (C10) n-decane (124-18-5) (C12) n-dodecane (112-40-3) (C14) n-tetradecane (629-59-4) (C16) n-hexadecane (544-76-3) (C18) n-octadecane (593-45-3) (C20) n-eicosane (112-95-8) (C21) n-heneicosane (629-94-7) (C22) n-docosane (629-97-0) (C24) n-tetracosane (646-31-1) (C26) n-hexacosane (630-01-3) (C28) n-octacosane (630-02-4) (C30) n-triacontane (638-68-6) (C32) n-dotriacontane (544-85-4) (C34) n-tetratriacontane (14167-59-0) (C36) n-hexatriacontane (630-06-8) (C38) n-octatriacontane (7194-85-6) (C40) n-tetracontane (4181-95-7) 200 µg/ml each in pentane, 5 ml/ampul cat.# 30542 (ea.) NJDEP EPH 10/08 Rev. 2 Aromatics Matrix Spike Mix (18 components) Acenaphthene (83-32-9) Acenaphthylene (208-96-8) Anthracene (120-12-7) Benz(a)anthracene (56-55-3) Benzo(a)pyrene (50-32-8) Benzo(b)fluoranthene (205-99-2) Benzo(ghi)perylene (191-24-2) Benzo(k)fluoranthene (207-08-9) Chrysene (218-01-9) Dibenz(a,h)anthracene (53-70-3) Fluoranthene (206-44-0) Fluorene (86-73-7) Indeno(1,2,3-cd)pyrene (193-39-5) 2-Methylnaphthalene (91-57-6) Naphthalene (91-20-3) Phenanthrene (85-01-8) Pyrene (129-00-0) 1,2,3-Trimethylbenzene (526-73-8) 200 µg/ml each in acetone:toluene (50:50), 5 ml/ampul cat.# 30543 (ea.) NJDEP EPH 10/08 Rev. 2 Aromatics Fractionation Check Mix (16 components) Acenaphthene (83-32-9) Acenaphthylene (208-96-8) Anthracene (120-12-7) Benz(a)anthracene (56-55-3) Benzo(a)pyrene (50-32-8) Benzo(b)fluoranthene (205-99-2) Benzo(ghi)perylene (191-24-2) Benzo(k)fluoranthene (207-08-9) MA EPH Aromatic Hydrocarbon Standard (17 components) Acenaphthene (83-32-9) Acenaphthylene (208-96-8) Anthracene (120-12-7) Benz(a)anthracene (56-55-3) Benzo(a)pyrene (50-32-8) Benzo(b)fluoranthene (205-99-2) Benzo(k)fluoranthene (207-08-9) Benzo(ghi)perylene (191-24-2) Chrysene (218-01-9) Dibenz(a,h)anthracene (53-70-3) Fluoranthene (206-44-0) Fluorene (86-73-7) Indeno(1,2,3-cd)pyrene (193-39-5) 2-Methylnaphthalene (91-57-6) Naphthalene (91-20-3) Phenanthrene (85-01-8) Pyrene (129-00-0) 1,000 µg/ml each in methylene chloride, 1 ml/ampul cat.# 31458 (ea.) MA EPH Aliphatic Hydrocarbon Standard (14 components) (C9) n-nonane (111-84-2) (C10) n-decane (124-18-5) (C12) n-dodecane (112-40-3) (C14) n-tetradecane (629-59-4) (C16) n-hexadecane (544-76-3) (C18) n-octadecane (593-45-3) (C19) n-nonadecane (629-92-5) Chrysene (218-01-9) Dibenz(a,h)anthracene (53-70-3) Fluoranthene (206-44-0) Fluorene (86-73-7) Indeno(1,2,3-cd)pyrene (193-39-5) Phenanthrene (85-01-8) Pyrene (129-00-0) 1,2,3-Trimethylbenzene (526-73-8) 400 µg/ml each in hexane:toluene (50:50), 5 ml/ampul cat.# 30545 (ea.) MA EPH Surrogate Spike Mix (2 components) 1-Chlorooctadecane (3386-33-2) o-terphenyl (84-15-1) 4,000 µg/ml each in acetone, 1 ml/ampul cat.# 31479 (ea.) (C20) n-eicosane (112-95-8) (C22) n-docosane (629-97-0) (C24) n-tetracosane (646-31-1) (C26) n-hexacosane (630-01-3) (C28) n-octacosane (630-02-4) (C30) n-triacontane (638-68-6) (C36) n-hexatriacontane (630-06-8) 1,000 µg/ml each in hexane, 1 ml/ampul cat.# 31459 (ea.) NJDEP EPH 10/08 Rev. 2 Aliphatics Fractionation Check Mix (18 components) (C9) n-nonane (111-84-2) (C10) n-decane (124-18-5) (C12) n-dodecane (112-40-3) (C14) n-tetradecane (629-59-4) (C16) n-hexadecane (544-76-3) (C18) n-octadecane (593-45-3) (C20) n-eicosane (112-95-8) (C21) n-heneicosane (629-94-7) (C22) n-docosane (629-97-0) (C24) n-tetracosane (646-31-1) (C26) n-hexacosane (630-01-3) (C28) n-octacosane (630-02-4) (C30) n-triacontane (638-68-6) (C32) n-dotriacontane (544-85-4) (C34) n-tetratriacontane (14167-59-0) (C36) n-hexatriacontane (630-06-8) (C38) n-octatriacontane (7194-85-6) (C40) n-tetracontane (4181-95-7) 400 µg/ml each in hexane, 5 ml/ampul cat.# 30544 (ea.) Learn more about Restek reference standards at www.restek.com/standards www.restek.com 7

Solid Phase Extraction Cartridges Proven Quality Superior Cleanliness Method-Specific Performance Available with the following sorbents: Silica: Multipurpose EPH Silica: Petroleum Florisil Adsorbent: Pesticides CarboPrep Adsorbent: Dirty Samples FREE samples available! Contact us or your local Restek representative. Learn more at www.restek.com/resprep Questions about this or any other Restek product? Contact us or your local Restek representative (www.restek.com/contact-us). Restek patents and trademarks are the property of Restek Corporation. (See www.restek.com/patents-trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. 2016 Restek Corporation. All rights reserved. Printed in the U.S.A. www.restek.com Lit. Cat.# EVSS2574-UNV