SNR-FOSC-F. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-F. Installation Manual

Similar documents
SNR-FOSC-D. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-D. Installation Manual

SNR-FOSC-D-T. Installation Manual SNR-FOSC-D-T. Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

SNR-FOSC-H. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-H. Installation Manual

HSC-O1. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC)

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) Installation Manual

B1-OPCL Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) FOSC-GPJ-A024. Installation Manual

FOSCHF Horizontal Fiber Optic Splice Closure

FOSC-400A4 INSTALLATION INSTRUCTION

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

FOSC-100 B/H FOSC-100 B2/H

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

3000SC Fiber Optic Splice Closure

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

OPTICAL FIBER CLOSURE

Fiber optic splice closure

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

CS Fiber Optic Splice Case. Instruction

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

Section 3 FIBERLIGN Closure Series

3M Fiber Dome Closure FDC 10

INSTALLATION INSTRUCTIONS

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

Closure End Plates and Accessories

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

19 1HU Splicing and Front Patching Shelf

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

B Polyethylene Tape. B Splicing Covering. Holster

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

Opti-Guard Splice Enclosure

Toyota Prius Interior Light Upgrade

COYOTE Terminal Dome Closure 6.5" x 22"

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

Heat Shrink closure Non - Pressurized & Pressurized RTSM Dome Closure RLSS RPBS Vault Closure Lead Sleeve Mechanical Closure Pillar Dp Jointing Kit

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

COYOTE LCC (Low Count Closure)

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

OAsys. Outside Plant. Metallic Joint Closure VXOK units. Features and Benefits

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

Opticom Rack Mount Fiber Enclosures

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

INSTALLATION INSTRUCTIONS

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

WRSS Wraparound Repair Sleeve Installation Instructions

INSTALLATION INSTRUCTIONS

Fiber Connector Shelf (CCS)

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

Power Connection Kit installation instructions

Terminator DP/FAK-5 and FAK-5L

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

TOYOTA AVALON INTERIOR LIGHT UPGRADE Section TOYOTA II - Installation AVALON Procedures

FLOODLIGHT unit IMPORTANT WARNING! RRAC055/RRAC059. INSTALL TIME: 30 mins

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

8400 Series Fiber Distribution System

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Universal Splice Tray Installation Instructions

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

INSTALLATION INSTRUCTIONS

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

HS6B Series Subminiature Interlock Switch

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO COMPLY MAY VOID DAVIES, CRAIG WARRANTY.

ET-PWR-END-KIT Installation Instructions (part #JSR00)

INSTALLATION INSTRUCTIONS

SCION xd INTERIOR LIGHTING UPGRADE Preparation

Please note that these instructions apply to the Toyota Towing Wire Harness. The part you re looking for is PT

Optical Fiber Closure. Fuzzy Integral Closure for Optical Cable VSOF-RN402A VISSEM. Electronics Co., Ltd.

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

DARMAN. ENDURA II Cloth Towel Cabinet Product Guide. Manufacturing Company, Inc Lincoln Ave., Utica, NY 13502

TOYOTA TACOMA XM SATELLITE RADIO Preparation

6. Rear Drive Shaft REAR DRIVE SHAFT

4. Front and Rear Drive Shafts

MNBRATKIT MidNite Brat Solar Charging Kit

Toyota Venza Interior Light Upgrade

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

Series 3 & 4 Stainless Steel - Accessories

1. General Description

Section II - Installation Procedures Part Number : Accessory Code IL1 Kit Contents. Color Applicability/Trim Level. Hardware Bag Contents

fiber optic cable Outdoor Cables

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

Transcription:

(FOSC) SNR-FOSC-F Installation Manual

1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation. The scope of application is: aerial, underground, wall-mounting, handhole-mounting and duct-mounting. The ambient temperature ranges from -40 to +65. 2. Basic structure and configuration 2.1 Dimension and capacity Outside dimension (Height x Diameter) Weight (excluding outside box) Number of inlet/out ports Diameter of fiber cable Capacity of FOSC 455mm 220mm 3350g 3800g 6 pieces Φ8mm~Φ21 mm Bunchy: 12-288 (cores), Ribbon: up to 864(cores) 2.2 Main components No. Name of components Quantity Usage Remarks 1 FOSC cover 1 piece Protecting fiber cable 2 Fiber optic splice tray (FOST) Max. 6 trays (either bunchy or ribbon splices in whole Fixing heat shrinkable protective sleeve and holding fibers 3 Fiber holding tray 1 pcs Holding fiber with protective coat 4 Base 1set Fixing internal and external structure 5 Plastic hoop 1 set Fixing between FOSC cover and base 6 Gasket ring 1 set Big gasket ring is used to seal FOSC cover and base. Small gasket ring is used to seal entry/exit tube 7 Pressure testing valve 1 set After inject air, it is used for pressure testing and 8 Earthing deriving device sealing testing 1 set Deriving metallic parts of fiber cables in FOSC for earthing connection 1 Height x Diameter 350mm x 220mm Suitable for: Bunchy: 12, 24,48 (cores) Ribbon: 6,12 (pieces) 1 piece of big gasket ring, 6 pieces of small gasket ring Configuration as per requirement Configuration as per requirement

2.3 Main accessories and special tools No. Name of accessories Quantity Usage Remarks 1 Heat shrinkable protective sleeve Protecting fiber splices Configuration as per capacity 2 Nylon tie Fixing fiber with protective coat Configuration as 3 Earthing wire 1 piece Putting through between earthing devices 4 Abrasive cloth 1 piece Scratching fiber cables 5 Labeling paper 1 piece Labeling fibers per capacity 6 Special wrench 2 pieces Installing and tightening nut of reinforced core and nut (plastic) of entry/exit tube 7 Measuring paper 1 piece To measure perimeter, of which its diameter is enlarged with seal tape 8 Seal tape 1 ring Enlarging diameter of fiber cable which fits in with gasket ring. 9 Insulation tape 1 ring Enlarging diameter of fiber cable for easy fixing 10 Metal hoop 1 set For wall mounting and pole hugging 11 Buffer tube decided by Hitched to fibers and fixed with customers FOST, managing buffer. 12 Desiccant 1bag Put into FOSC before sealing for desiccating air Configuration as per specification Configuration as per requirement 3. Necessary tools for installation 3.1 Supplementary materials (to be provided by operator) Name of materials Scotch tape Ethyl alcohol Gauze Usage Labeling, temporarily fixing Cleaning Cleaning 2

3.2 Special tools (to be provided by operator) Name of tools Fiber cutter Fiber stripper Combo tools Usage Cutting off fiber cable Strip off protective coat of fiber cable Assembling FOSC 3.3 Universal tools(to be provided by operator) Name of tools Band tape Pipe cutter Electrical cutter Combination pliers Screwdriver Usage and specification Measuring fiber cable Cutting fiber cable Take off protective coat of fiber cable Cutting off reinforced core Crossing/Paralleling screwdriver Scissor ---- Waterproof cover Metal wrench Waterproof, dustproof Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator) Name of instruments Fusion Splicing Machine OT DR Provisional splicing tools Usage and specification Fiber splicing Splicing testing Provisional testing Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves. 3

4. Installation flow chart 1. Open the closure 2. Determine length of fiber cable to be fixed and stripped inside FOSC 3. Strip off protective coats of fiber cable and fiber 4. Separate fiber cores and prepare work prior to fixing fiber cable 5. Fix fiber cable and reinforced core 6. Splice fibers 7. Install heat shrinkable protective sleeve and house fibers 8. Check up comprehensively 9. Assemble FOSC housing and fix FOSC 4

5. The process of installing FOSC. 5.1 Step One - Open the closure 5.1.1 Cleaning the locale and determine where to install the FOSC and then place fiber cables required. 5.1.2 Check whether the main components and accessories have been well prepared inside the package. 5.1.3 Open the closure 1 Demount hoop fixing bolt and pull hoop locking system out, then proceed in demounting the hoop. 2 Pull the FOSC cover upwards out, installation could begin. 5.1.4 See Drawing 1 Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof. Hoop (left) Hoop (right) Hoop connector Hoop fixing bolt FOST Fixing slot of heat shrinkable protective coat Grommet Fiber holding tray Hoop locking system Fixing shelf for FOST FOST 90 ã FOSC cover Grommet FOST cover Big gasket ring Entry/exit tube Nut (plastic) Base Fixing device for reinforced core Drawing 1 5

5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC 5.2.1 1. in 120mm length: the distance from small gasket ring to fiber cable pressboard 2. in 1740mm length: it is used to be winded and spliced after stripping. 3. Fiber with protective coat in 140mm length: the distance from the fixing point of fiber cable to the fixing point of FOST (fiber optic splice tray). 4. Fiber in 1600mm length: after stripping off the protective coat, it is to be winded inside the FOST after splicing with other fibers 5.2.2 See Drawing 2 Important issues: 1. Reserve enough length of fiber cable to be spliced. 2. Stripping length also could be decided by customers according to installation requirement 120mm fixing length of fiber cable inside FOSC 1740mm length of protective coat of fiber cable to be stripped off 140mm length of fiber with protective coat 1600mm length of protective coat of fiber to be stripped off Temp. locating mark Drawing 2 6

5.3 Step Three Strip off protective coat of fiber cable and fiber 5.3.1 Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the stripper, please refer to Drawing 2 for stripping length. Stripping length also could be decided according to installation requirement 5.3.2 See Drawing 3. Important issues: If it is difficult to pull all the protective coat of fiber cable at one time, strip it off section by section to avoid fiber breakage. Entry terminal fiber cable Stripping terminal fiber cable Temp. locating mark Cutter Drawing 3 5.4 Step Four Separate fiber cores and prepare work prior to fixing fiber cable. 5.4.1 Wind 2 layers of insulation tape on protective coat of fiber core for protection. Meanwhile, get rid of the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber cable temporarily by adhesive tape. 5.4.2 Reserve reinforced core in 50mm length and cut off the unnecessary ones. 5.4.3 See Drawing 4. Important issues:entry/exit tubes are to be selected accurately to make it easy for splicing and sealing. 7

Adhesive tape Fiber Reinforced core 50mm Drawing 4 Fiber with protective coat Adhesive tape 8

5.5 Fix reinforced core, and pyrocondense, fix and seal fiber cable. 5.5.1 This FOSC is provided with 6 entry/exit tubes, among these tubes, 2 entry/exit tubes suit for fiber cable with max. diameter ф 21mm, 4 entry/exit tubes suit for fiber cables with max. diameter ф 16mm. 5.5.2 After deciding number of fiber cable entry/exit, demount the nut, gasket and gasket ring of the corresponding entry/exit tubes according to the diameters of fiber cables actually to be installed, insert them into fiber cable in sequence, then insert fiber cables into entry/exit cable, tighten the nut in order to seal properly. 5.5.3 Do not demount the nut of entry/exit tubes which fiber cables are not installed. 5.5.4 While diameter is not big enough, enlarge the diameter with seal tape at fixing position of small gasket ring in order to improve sealing. 5.5.5 Fix fiber cable to the fixing seat, press it with the pressboard. While diameter is small, enlarge the diameter with insulation tape at the fixing position of fixing seat. 5.5.6 Demount the nut of fixing device of reinforced core with special wrench (plastic one), set reinforced core into fixing slot, tighten the nut, retighten it with metal wrench (metal wrench to be provided by operator). 5.5.7 See Drawing 5 Important issue: Fixing nut of reinforced core should be tightened. 9

Fiber Fiber with protective coat Pressure testing valve Gasket (plastic) Nut (plastic) Small gasket ring Adhesive tape Adhesive tape Big gasket ring Fixing device for reinforced core Reinforced core Bracket Base Fiber with protective coat Earthing deriving device Entry/exit tube Drawing 5 FOST Fiber Grommet Fiber holding tray Adhesive tape Fiber 5.6 Step Six - Splice fibers 5.6.1 Follow user manual of fusion splicing machine to splice fiber. Important issue: pay attention to the twist and bend of fiber 5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers. 5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve. 10

( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.) 5.7.2 See Drawing 6 Important issue: pay attention to the twist and bend of fiber. FOST Fiber (bunchy or ribbon) Heat shrinkable protective sleeve Fixing slot of heat shrinkable protective sleeve (bunchy or ribbon) Fiber(bunchy or ribbon) Nylon tie Nylon tie Fiber with protective coat Fiber with protective coat Drawing 6 5.8 Step Eight - Check up comprehensively To ensure the technical requirements, the following instructions must be followed: 5.8.1 Fibers with protective coat are fixed with nylon tie at the entrance of FOST. 5.8.2 Grommet should be pressed from inside to outside in order to properly install FOST. 5.8.3 If there are fibers with protective coat reserved, wind it into the fiber holding tray. 5.8.4 Check whether the internal tighteners and reinforced core are well tightened. 5.8.5 Check whether gasket ring is installed neatly and smoothly without any breakage. If not, level it up with seal tape. 5.8.6 See Drawing 7. Important issues: If any problems occur, they should be solved right away. 11

Grommet FOST cover Fiber holding tray FOST Fiber with protective coat Nylon tie Fiber with protective coat Fixing shelf for FOST Fixing device for reinforced core Fiber with protective coat Reinforced core Reinforced core Big gasket ring Fixing seat Base Bracket Pressboard Entry/exit tube Nut (plastic) Drawing 7 5.9 Step Nine Assemble FOSC housing and fix FOSC 5.9.1 Put desiccant into FOSC 5.9.2 Put FOSC cover on base directly. 5.9.3 Install plastic hoop between FOSC cover and the base, tighten hoop locking system, which is to be fixed by hoop fixing bolt then. 12

5.9.4 All nuts (plastic ones) of base need to be retightened once more. 5.9.5 FOSC installation 1 Aerial application: fix metal hoop and transom to the pole. Please refer to Drawing 8 2 Wall mounting application: fix the bracket on the wall with the bolt. (metal hoop is not required.) 3 Underground application: metal hoop is not required. 5.9.6 See drawing 8 Important issues: 1. Pay attention while installing plastic hoop. 2. The specification of the bolt for wall-mounting is M8. 13

6. Fiber Optic Splice Closures (FOSC) inspecting and testing items Inspecting item Package Appearance Sign Fiber storage device Electrical jointing device Sealing performance Re-sealing performance Pull Punching Technical Requirements Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. There is a clear sign on the housing, such as name and model of the product, etc. The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa ± 5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Bearing pull is 800N at axle orientation, there should be no breakage on the housing. Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Inspecting type Routine test (Before leaving Type test factory) full At least 3 sets sampled each time At least 3 sets sampled each time 14

Impact Bending Torsion Temperature circle Voltage resistance strength Isolating resistance Bearing impact energy of 16N m, 3 times of impacts there should be not breakage on the housing The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±45 0 for 10 circles, there should be no breakage on the housing Bearing torsion 50N m, 10 circle at torsion angle±90 0, There should be no breakage on the housing. Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40 ~+65, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is 5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be 2 10 4 MΩ. At least 3 sets sampled each time At least 3 sets sampled each time 15

GUARANTEE: CONTACT: Address: Building 118, Vonsovskogo Street 1, Yekaterinburg, Russia Tel: +7(343) 379-98-38 Fax: +7(343) 379-98-38 E-mail: info@nag.ru Online shop: http://shop.nag.ru 16