JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

Similar documents
COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

COYOTE Terminal Dome Closure 6.5" x 22"

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE LCC (Low Count Closure)

COYOTE STP (Service Termination Point)

COYOTE STP (Service Termination Point)

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Section 1 COYOTE Closure Series

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

Section 1 COYOTE Closure Series

Section 1 COYOTE Closure Series

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

INSTALLATION INSTRUCTIONS

Closure End Plates and Accessories

Section 3 FIBERLIGN Closure Series

CS Fiber Optic Splice Case. Instruction

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

INSTALLATION INSTRUCTIONS

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Environmental Distribution Center (EDC-06P-NH)

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

Section 1 COYOTE Closure Series

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

8400 Series Fiber Distribution System

FOSC-400A4 INSTALLATION INSTRUCTION

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

3000SC Fiber Optic Splice Closure

3M Fiber Dome Closure FDC 10

Fiber Splice Panel Rack Mount User Manual

Fiber optic splice closure

Opti-Guard Splice Enclosure

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

OPTICAL FIBER CLOSURE

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

SPORTSTER SADDLEBAG KIT. i i02212

FOSC-100 B/H FOSC-100 B2/H

FARM MODEL INSTALLATION INSTRUCTIONS

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

INSTALLATION INSTRUCTIONS

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

#GL18006-L2 Honda Gold Wing 1800 & F6B models - All Years Lower Cowl LED Driving Lights INSTALLATION INSTRUCTIONS

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Section 10 ARMADILLO Stainless Series

YOURx-Aerial Terminal Installation Manual

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

SUT-250-S (These instructions are used for SUT-250-SCLC also)

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

SUT-450-I ASSEMBLY REQUIREMENTS

Stowe Cargo Management System

Universal Splice Tray Installation Instructions

INSTALLATION INSTRUCTIONS

SAE STANDARD BOLT ASSEMBLY NUMBER 60020_IR4 INSTALLATION AND OPERATIONS MANUAL

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

FIBER CONNECTOR SAFETY WARNINGS

Installation Guide. Stowe Cargo Management System. Table of Contents

Fiber Connector Shelf (CCS)

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

INSTALLATION MANUAL. Thunderstone Manufacturing LLC 3400 West O Street Lincoln, NE (Fax)

INSTALLATION INSTRUCTIONS

3M Closure System 2-Type Cover (505)

WOC & WOC Top & Back Installation Instructions

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

WAVETRAX USER MANUAL

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

LPE C5 Battery Relocation Kit

INSTALLATION & OWNER S MANUAL

INSTALLATION INSTRUCTIONS

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

Section 7 - Troubleshooting Guide

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

WRSS Wraparound Repair Sleeve Installation Instructions

INSTALLATION INSTRUCTIONS

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

LEXUS RC 350/RC-F ILLUMINATED DOOR SILLS Preparation

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

PONTIAC FIREBIRD

w w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

INSTALLATION INSTRUCTIONS

Assembly Manual. 1/10th World GT car

Instructions for Use - Opt-X 1000i Enclosure

Transcription:

JANUARY 2015 COYOTE Dome Closure 6-1/2" x 17" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product before application. 1 2 3 6 4 5 7 8 9 10 NOMENCLATURE 1. Dome cover (1) 2. Organizer with 4-Port End Plate Assembly 3. Transport Tubing Kit (1) (In Dome Kits for Unitube/Ribbon Applications) 4. Dome Gasket (1) 5. Dome Collar (1) 6. Silicone Lubricant (4 five gram packets) 7. Cable Grommet (2) 8. Hose Clamp (4) 9. Strength Member Bracket (2) 10. Disposable Glove (1) TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools Catalog Number 8006944 8006945 6.5" x 17" COYOTE Dome Closure Kits Description COYOTE 6.5" x 17" Dome Closure for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer Tube Organizer Assembly with 4-Port End Plate Assembly, (1) Dome, (1) Collar Assembly, (1) Gasket, (1) Small Parts Bag COYOTE 6.5" x 17" Dome Closure for Unitube/Ribbon Applications. Includes: (2) Grommets, (1) Transition Tray Organizer Assembly with 4-Port End Plate Assembly, (1) Dome, (1) Collar Assembly, (1) Gasket, (1) Transition Tubing Kit, (2) Transport Tubing Kits, (1) Small Parts Bag Accessory Kits COYEPFIX1 COYOTE Dome End Plate Fixture Mounting Brackets 8003831 Aerial Mounting Bracket (Dome Mount) - Strand Applications 8004035 Aerial Adjustable Offset Mounting Bracket (Dome Mount) - Strand Applications 8003833 Aerial Mounting Bracket (Dome Mount) - ADSS Applications 8004036 Aerial Adjustable Offset Mounting Bracket (Dome Mount) - ADSS Applications 8003702 Pole/Wall Mounting Bracket 8003835 Universal Mounting Bracket Kit for Hand Hole Applications 8003707 Swing Arm for Hand Hole Applications 8004003 Manhole Support 1

Splice Tray/Closure Capacities for 6.5" x 17" COYOTE Dome Closures Splice Tray Catalog # Low Profile LITE-GRIP (24 ct) Splice Type Trays per Closure Closure Splice Capacity 80809958 Single Fusion 6 144 LITE-GRIP (40 ct) 80808945 Single Fusion 3 120 LITE-GRIP (144 ct) LGSTR144 Mass Fusion/ Ribbon 3 432 COYOTE Grommet Chart For use in COYOTE GLC, Aerial, LCC, Dome, In-Line RUNT, Taut & Terminal Closures PLP Catalog Number Cable Range Inches (mm) Description Splitting Location 8003691.42 -.60 (11-15 mm) 1-entry grommet 8003692.60 -.85 (15-22 mm) 1-entry grommet 8003693.85-1.0 (22-25 mm) 1-entry grommet 8003694 1.0-1.25 (25-32 mm) 1-entry grommet 8003663.42 -.60 (11-15 mm) 2-entry grommet 8003664.30 -.43 (8-11mm) 4-entry grommet 8004065.250 -.312 (6.4-7.9 mm) 4-entry grommet 8003990.50 -.60 (12.7-15.2 mm).125 -.25 (3.2-6.4 mm) and flat drop 4-entry grommet 8003665.125 -.25 (3-6 mm) 6-entry grommet 8003676.42 -.60 (11-15 mm).125 -.25 (3-6 mm) 7-entry grommet 8003677.125 -.25 (3-6 mm) 8-entry grommet NOTE: Grommet Kit contains (1) Grommet, (1) Cable Measure Tape, (2) Silicone Lubricant Packs, (1) Set of Plugs & (1) Glove 2 2015 Preformed Line Products Company. All rights reserved.

End Plate Preparation Step #4 Reassemble organizer assembly to end plate with mounting clip and 1/4" hex bolt and nut. Step #1 Remove support bar mounting clip from organizer assembly. Mounting Clip 1/4" Hex Bolt Hex Nut Cable Preparation Step #2 Remove end plate from organizer assembly. Step #5 Measure cable to determine diameter and hole location to use in grommet. Step #3 Remove the end plate caps from the selected ports and break out the tabs. Step #6a If using cut cable, insert cable through grommet. If your application requires express/balloon/ring cut cables, see Step 7 for grommet slitting procedure. Cable Diameter Range Install plug in unused port 3

Step #6b Installing Figure 8 Style Cables and Cables with Tracer Wires - Remove tracer wire or ground wire from the portion of the cable that will be positioned in the grommet and insert cable into grommet. Step #8 Prepare loose tube/buffer tube or unitube/ ribbon cable(s) for cut applications. Cable with Tracer Wire NOT CORRECT Min. of 77" (2.0 m) Not Correct Installation NOT CORRECT Figure 8 Style Cable Correct Installation Minimum Sheath Opening for Cut Cable Applications Min. of 77" 2.0 m PLP Tip: Leave about 8" (203 mm) of strength member to trim later. Not Correct Installation Step #7 Correct Installation Grommet Slitting If slitting is required, lay grommet on a stable flat surface. Position utility knife with the cutting edge against the top surface and cut through grommet. Consult grommet chart on page 2 for slitting locations of all grommets. Step #9a Prepare loose tube/buffer tube or unitube/ ribbon cable(s) for mid sheath applications (Express/Balloon/Ring Cut). 77" (2.0 m) Buffer (Loose) Tube Cable OFFICE/C.O. Buffer Tube (After Cut) A X Ribbon Cable PLP Tip: Use a pen to sketch slitting lines on top surface of grommet prior to cutting. 77" (2.0 m) OFFICE/C.O. NOT CORRECT Slit Slit Not Correct Slitting Angle Slit Slit Correct Slitting Angle Ribbon (After Cut) NOTE: When expressing ribbons in the transition tray of the closure at this measurement, the maximum number of ribbons that can be expressed is 24 ribbons (288 fibers). For Applications Where Fiber is Dedicated to the Splice Point Sheath Opening Min. of 77" (2.0 m) Fiber/Buffer Tube Cut Location A (see image above) X A PLP Tip: Leave about 8" (203 mm) of strength member to trim later. 4

Step #9b B X Prepare loose tube/buffer tube or unitube/ ribbon cable(s) for mid sheath applications (Express/Balloon/Ring Cut). Buffer Tube (After Cut) 154" (3.9 m) Buffer (Loose) Tube Cable OFFICE/C.O. Cable Sheath Opening for Applications Where Fiber is Expressed through the Buffer Tube Step #9c Prepare loose tube/buffer tube cable(s) for expressed fiber (buffer tube window cut). C X 112" (2.8 m) Buffer Tube Opening Location for Window Cut OFFICE/C.O. Buffer Tube (After Cut) X C B X Ribbon (After Cut) 154" (3.9 m) Ribbon Cable OFFICE/C.O. Buffer Tube Opening Location for Window Cut For Applications Where Fiber is Expressed through the Buffer Tube Sheath Opening 112" (2.8 m) Buffer Tube Opening Location C (see image above) PLP Tip: Leave about 8" (203 mm) of strength member to trim later. Ribbon (After Cut) NOTE: When expressing ribbons in the transition tray of the closure at this measurement, the maximum number of ribbons that can be expressed is 12 ribbons (144 fibers). For Applications Where Fiber is NOT Dedicated to the Splice Point Sheath Opening Max. of 154" (3.9 m) Fiber/Buffer Tube Cut Location B (see image above) Step #10 Prepare Central/Buffer Tube(s) for Unitube/ Ribbon Cable Applications. Cable in Bottom Entry Ports 4.5" (11.3 cm) PLP Tip: Leave about 8" (203 mm) of strength member to trim later. Cable in Top Entry Ports 1.5" (3.8 cm) 5

Step #11 If the cable contains Kevlar, braid roughly 3" (7.2 cm) of the Kevlar. Step #15 Position strength member under cap of strength member bracket. Strength Member 3" (7.2 cm) Step #12 Align sheath opening with end of slot of the strength member bracket as shown. Step #16 If the cable contains Kevlar, wrap the braided Kevlar around the stud of the cap as shown. Cable Sheath Opening Braided Kevlar Step #13 Trim strength member(s) flush with end of the strength member bracket(s). Strength Member Bracket Step #17 Tighten nut of cap to secure strength member and braid under the cap. Step #14 Install cap on strength member bracket. Cap 6 Kevlar is a registered trademark of DuPont.

Step #18 Secure cable to strength member bracket with hose clamp. Step #21 Secure shielded cable to strength member bracket with hose clamp. NOTE: Visually inspect to confirm buffer tubes are not pinched or distorted as cable is secured to bracket with hose clamp. Attaching Shielded Cable to Strength Member Bracket Step #22 Lubricate the outer surface of the grommet. Step #19 For shielded cable applications, PLP recommends using a 3M 4460-D/FO Fiber Optic Shield Connector (PN: 80803989). Install shield connector on cable and insert stud of shield connector through slot of strength member bracket. Lubricate sealing surface of grommet with silicone lubricant provided. NOTE: Visually inspect to confirm buffer tubes are not pinched or distorted as shield connector is secured to bracket. Follow standard company practices when applying shield connector to cable. Step #23 Position grommets in end plate slots. Do not align grommet slit with end plate seam. Step #20 Secure shield connector to strength member bracket with nut and secure cable strength member under cap of the strength member bracket. NOTE: Visually inspect to confirm buffer tubes are not pinched or distorted as shield connector is secured to bracket. 7

Step #24 Position slot of strength member bracket leg over stud and pull back cable. Step #26 Install cable caps and secure with hex bolts. Step #25 Install strength member bracket on stud. Install lock washer and nut against the bracket, but do not tighten fully, so the bracket can slide as the grommet is inserted. NOTE: Tighten bolts by hand evenly until cable cap is fully seated (DO NOT USE POWER TOOLS TO TIGHTEN BOLTS). When using a can wrench or nut driver, the installed torque is 35 to 40 in-lbs. NOTE: TIGHTEN ALL UNUSED CABLE CAPS. IMPORTANT: TIGHTEN DOWN THE STRENGTH MEMBER BRACKET AFTER THE CAPS ARE TIGHTENED. Step #27 Complete end plate assembly. Lock Washer & Nut 8

Buffer Tube Applications Unitube Applications Step #28 Route and store buffer tubes in storage brackets. Step #30 Route and secure central tube of unitube cables to transition tray. Tie Wraps Step #31 Use transition tubes to route fibers or ribbons from upper cable ports. Transition Tube Step #29 Route buffer tube(s) to splice tray(s) and secure. Step #32 Route feeder fibers or ribbons within transition tray. 9

Step #33 Route express fibers or ribbons under clips. Splice Tray Management Organizer Clip Step #37 Route incoming fibers in splice tray. Splices 1-12 21-32 Step #34 Insert fibers or ribbons to be routed to splice tray(s) into transport tube(s) and secure tubes to transition tray. Splices 13-20 33-40 Step #35 Install cover on transition tray. Cover Step #38 Route outgoing fibers in splice tray. Splices 1-12 21-32 Step #36 Route transport tube(s) to splice tray(s) and secure. Splices 13-20 33-40 10

Step #39 Splice incoming fibers to outgoing pigtail fibers per your accepted company practices. Step #43 Work the gasket into the groove. Step #40 Secure splice tray(s) with hold down strap. Before After Step #44 Re-tighten all cable cap bolts (step #26) to assure that the cable caps are fully seated. When using a can wrench or nut driver, the installed torque is 35 to 40 in-lbs. Step #45 Position the dome over end plate. Dome & Collar Installation Step #41 Lubricate all surfaces around gasket with silicone lubricant to assure easy assembly and closure re-entry. Lubricate all inner surfaces of the gasket. Step #46 Position the collar flat on the work surface in front of the closure as shown below. Lubricate all outer surfaces of the gasket. Step #42 Slide end plate gasket onto end plate and press into groove. Make sure gasket is seated in groove of end plate 11

Step #47 While holding the collar in place, compress a portion of the end plate into the dome and insert them in the groove of the collar near the latch, as shown below. Step #49 Check to make sure the lip of the dome is captured within the collar half Front Side Lip of dome is captured within collar. Back Side Lip of dome is captured within collar. Step #48 While holding the collar in place, push against the end of the dome and slightly lift and push the other half of the dome up and over the lip of the collar with your fingers to fully install the dome in the collar half. Step #50 Install the other collar half onto the closure. Step #51 Secure the collar with the latch and pin. 12

Flash Test Procedure Step #54 Spray all sealing surfaces of the dome end-plate with soapy water to determine if there are any leaks. Step #52 Remove cap from air valve of end plate. Step #53 Pressurize closure up to a max of 10 psi. Step #55 Release the pressure in the closure using the bump on the top of the air valve cap. 13

Common End Plate Leaks During Flash Testing 17.85" (453 mm) Leak occurring at the corner of the cable port due to the cap of the cable port not being fully tightened. 8.57" (218 mm) 10.04" (256 mm) Leak occurring at the corner of the cable port To resolve, remove collar, remove End Plate/ Organizer Assembly from the Dome, and tighten bolts on end cap where leak occurred. Reassemble and flash test to confirm that the leak has stopped. 8.57" (218 mm) 22.60" (574 mm) Leak occurring at the cable entry of the grommet due to the cable not being within the stated cable diameter range of the grommet Leak occurring at the cable entry of the grommet To resolve, remove collar and remove End Plate/Organizer Assembly from the Dome. Remove end cap where leak occurred, remove grommet, remeasure cable with measure tape provided and select proper grommet. Reassemble the components and flash test the closure to confirm that the leak has stopped. 14

Step #56a Aerial Mounting Options For 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Assemble each bug nut or ADSS clamp to each top aerial offset bracket as shown below. Step #56c For 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). For Taller Spacing. Align the top aerial offset bracket with the bottom aerial offset bracket in either Position 1 or Position 2 as shown below. Secure the top aerial offset bracket to the bottom aerial offset bracket with the bolts and keps nuts provided. Strand Clamp Position 1 Strand Clamp Shown ADSS Clamp Position 2 Strand Clamp Shown Step #57 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Insert hose clamp through slots in each of the bottom aerial offset brackets. Step #56b For 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). For Shorter Spacing. Align the top aerial offset bracket with the bottom aerial offset bracket in either Position 1 or Position 2 as shown below. Secure the top aerial offset bracket to the bottom aerial offset bracket with the bolts and keps nuts provided. Step #58 Slots 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Tighten each hose clamp around the dome. Position 1 ADSS Clamp Shown Position 2 ADSS Clamp Shown 15

Step #59 Strand Aerial Offset Bracket shown secured on a 6.5" Dome 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Bracket installed on dome closure. Step #62 COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Position the brackets in the banding channels of the dome. Tighten the banding until the brackets are secure. Step #60 Hand Hole Mounting Option COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Secure the Universal Mounting Bracket to the inner wall of the hand hole using 2 screws. Step #63 COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Slide the hanger brackets into the proper slots of the Universal Mounting Bracket and snap the hinged lid into place to secure the hanger brackets. Step #61 COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Insert banding (plastic or metal) through the slots of the hanger brackets. 16

Pole/Wall Mounting Option Step #65 The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Step #64 The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Position the bolts through the stud mount plate as shown, and install lock nuts on bolts until there is a 1/8" (3 mm) gap between the nut and the stud mount plate. Slide the bolts of stud mount plate into the slots of the pole/wall mount bracket as shown and tighten the lock nuts until the plates are secure. Stud Mount Plate Stud Mount Plate Pole/Wall Mount Bracket Secure Lock Nuts 1/8" (3mm) 17

Step #65 The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Step #66 The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Attach the dome pole/wall mount bracket to a pole or wall with either 5/8" through bolts, 1/4" lag screws, or banding straps. 1/4" Lag Screw Hole Attach the COYOTE Dome closure to the pole/ wall mount bracket by inserting the studs of the dome closure end plate through the stud holes of the stud mount plate and securing with the lock nuts provided. Banding Slots 1/4" Lag Screw Hole 5/8" Through Bolt Holes Secure Lock Nuts SP2980-8 18

19

SAFETY CONSIDERATIONS This application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual. FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN PERSONAL INJURY OR DEATH. Do not modify this product under any circumstances. This product is intended for use by trained technicians only. This product should not be used by anyone who is not familiar with, and not trained to use it. When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. For proper performance and personal safety, be sure to select the proper size PREFORMED product before application. PREFORMED products are precision devices. To insure proper performance, they should be stored in cartons under cover and handled carefully. P.O. Box 91129, Cleveland, Ohio 44101 440.461.5200 www.preformed.com e-mail: inquiries@preformed.com SP2980-8 20