Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual

Similar documents
SNR-FOSC-F. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-F. Installation Manual

SNR-FOSC-D. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-D. Installation Manual

HSC-O1. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC)

SNR-FOSC-D-T. Installation Manual SNR-FOSC-D-T. Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

SNR-FOSC-H. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-H. Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) Installation Manual

B1-OPCL Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) FOSC-GPJ-A024. Installation Manual

FOSCHF Horizontal Fiber Optic Splice Closure

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

FOSC-400A4 INSTALLATION INSTRUCTION

FOSC-100 B/H FOSC-100 B2/H

3000SC Fiber Optic Splice Closure

Fiber optic splice closure

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

OPTICAL FIBER CLOSURE

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

3M Fiber Dome Closure FDC 10

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

19 1HU Splicing and Front Patching Shelf

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

Section 3 FIBERLIGN Closure Series

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

CS Fiber Optic Splice Case. Instruction

Opti-Guard Splice Enclosure

Optical Fiber Closure. Fuzzy Integral Closure for Optical Cable VSOF-RN402A VISSEM. Electronics Co., Ltd.

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

Section II - Installation Procedures Part Number : Accessory Code IL1 Kit Contents. Color Applicability/Trim Level. Hardware Bag Contents

TOYOTA AVALON INTERIOR LIGHT UPGRADE Section TOYOTA II - Installation AVALON Procedures

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

Closure End Plates and Accessories

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

8400 Series Fiber Distribution System

Heat Shrink closure Non - Pressurized & Pressurized RTSM Dome Closure RLSS RPBS Vault Closure Lead Sleeve Mechanical Closure Pillar Dp Jointing Kit

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

Section 1 COYOTE Closure Series

Fiber Connector Shelf (CCS)

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

INSTALLATION INSTRUCTIONS

COYOTE Terminal Dome Closure 6.5" x 22"

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

Section 1 COYOTE Closure Series

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

B Polyethylene Tape. B Splicing Covering. Holster

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

Toyota Prius Interior Light Upgrade

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Conflicts. Toyota Avalon Interior Light Upgrade. Part Number Accesory Code: IL2. Color Applicability/Trim Level.

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

INSTALLATION INSTRUCTIONS

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

Series 3 & 4 Stainless Steel - Accessories

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

OAsys. Outside Plant. Metallic Joint Closure VXOK units. Features and Benefits

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

HS6B Series Subminiature Interlock Switch

Fiber Splice Panel Rack Mount User Manual

INSTALLATION INSTRUCTIONS

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Power Connection Kit installation instructions

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

INSTALLATION INSTRUCTIONS

Section 1 COYOTE Closure Series

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

FLOODLIGHT unit IMPORTANT WARNING! RRAC055/RRAC059. INSTALL TIME: 30 mins

Opticom Rack Mount Fiber Enclosures

CVO - with ipod Amp & Speaker Upgrade Install Instructions for Batwing Fairing

TOYOTA SOLARA EC REARVIEW MIRROR Section I - Installation Preparation

TOYOTA TACOMA XM SATELLITE RADIO Preparation

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

RAV4 TNS310 (Traffic) Plus

Environmental Distribution Center (EDC-06P-NH)

COYOTE LCC (Low Count Closure)

Terminator DP/FAK-5 and FAK-5L

for spiral staircases

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Universal Splice Tray Installation Instructions

C Power Connection Kit

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

Cargo Socket Kit. Securely connect connectors and terminals. Failure to do so can result in poor connections.

WRSS Wraparound Repair Sleeve Installation Instructions

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

TOYOTA SIENNA TRAILER WIRE HARNESS Preparation

Fizzle Intercooler Kit Installation Instructions

INSTALLATION INSTRUCTIONS

ET-PWR-END-KIT Installation Instructions (part #JSR00)

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Transcription:

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE Installation Manual

1. Scope of application This Installation Manual suits for one of the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation. It is can install various kind of PLC splitter and SC adaptor; it is especially for FTTH project. The scope of application is: aerial, underground, wall-mounting, handhole-mounting and duct-mounting. The ambient temperature ranges from -40 to +65. 2. Basic structure and configuration 2.1 Dimension and capacity Outside dimension (Height x Diameter) Weight (excluding outside box) Number of inlet/out ports Diameter of fiber cable Capacity of FOSC 500mm 228mm 3250g 4150g 1 large port + 4small port Φ7mm~Φ40 mm or 2*3mm drop cable Bunchy: 12-192 (cores), Ribbon: up to 288(cores) 2.2 Main components No. Name of components Quantity Usage Remarks 1 FOSC cover 1 piece Max. 12 trays 2 Fiber optic splice tray (bunchy) (FOST) Max.4trays ( ribbon) 3 Fiber holding tray 1 pcs 4 Base 1set 5 Plastic hoop 1 set 6 7 Gasket ring for 1 set Housing Protecting fiber cable Height x Diameter splices in whole 400mm x 220mm Fixing heat shrinkable Suitable for: protective sleeve and Bunchy: 12, 24 (cores) holding fibers Ribbon: 6(pieces) Holding fiber with Fixing internal and external structure Fixing between FOSC cover and base Big gasket ring is used to seal FOSC cover and base. Single ports Ф21mm,Ф 30mm seal rings or duplex Seal rings for cable ports Ф 21mm can be inlet/outlet ports 7pcs installed in the big cable inlet/outlet port.ф21mm,ф 12.5mm seal rings can be installed in the small cable 1

8 Plastic gasket 1 set 9 Pressure testing valve 1 set 10 Earthing device deriving 1 set 2.3 Main accessories and special tools inlet/outlet port. Protect elastic seal rings from white ant and corruption After inject air, it is used for pressure testing and sealing testing Deriving metallic parts of fiber cables in FOSC for earthing connection Configuration as per requirement Configuration as per requirement No. Name of accessories Quantity Usage Remarks 1 Heat protective sleeve shrinkable Protecting fiber splices 2 Nylon tie Fixing fiber with 3 Earthing wire 1 piece Putting through between earthing devices 4 Abrasive cloth 1 piece Scratching fiber cables 5 Labeling paper 1 piece Labeling fibers 6 Special wrench 3 pieces 7 Measuring paper 1 piece 8 Seal tape 1 ring 9 Insulation tape 1 ring 10 Metal hoop 1 set 11 Buffer tube 12 Desiccant 1bag decided by customers Installing and tightening nut of reinforced core and nut (plastic) of entry/exit tube To measure premetre, of which the diameter of fiber cable is enlarged with seal tape Enlarging diameter of fiber cable which fits in with gasket ring. Enlarging diameter of fiber cable for easy fixing For wall mounting and pole hugging Hitched to fibers and fixed with FOST, managing buffer. Put into FOSC before sealing for desiccating air 3. Necessary tools for installation 3.1 Supplementary materials (to be provided by operator) Name of materials Usage Configuration per capacity Configuration per capacity Configuration per specification Configuration per requirement as as as as 2

Scotch tape Ethyl alcohol Gauze Labeling, temporarily fixing Cleaning Cleaning 3.2 Special tools (to be provided by operator) Name of tools Fiber cutter Fiber stripper Combo tools Usage Cutting off fiber cable Strip off of fiber cable Assembling FOSC 3.3 Universal tools (to be provided by operator) Name of tools Band tape Pipe cutter Electrical cutter Combination pliers Screwdriver Usage and specification Measuring fiber cable Cutting fiber cable Take off of fiber cable Cutting off reinforced core Crossing/Paralleling screwdriver Scissor ---- Waterproof cover Metal wrench Waterproof, dustproof Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator) Name of instruments Fusion Splicing Machine OT DR Provisional splicing tools Usage and specification Fiber splicing Splicing testing Provisional testing Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves. 3

4. Installation flow chart 1. Open the closure 2. Determine length of fiber cable to be fixed and stripped inside FOSC 3. Strip off s of fiber cable and fiber 4. Separate fiber cores and prepare work prior to fixing fiber cable 5. Fix fiber cable and reinforced core 6. Fixing the adapter, pigtail, drop cable and Splice fibers 7. Install heat shrinkable protective sleeve and house fibers 8. Check up comprehensively 9. Assemble FOSC housing and fix FOSC 4

5. The process of installing FOSC. Step one - Open the closure Cleaning the locale and determine where to install the FOSC and then place fiber cables required. Check whether the main components and accessories have been well prepared inside the package. Open the closure See Drawing 1 1 Demount hoop fixing bolt and pull hoop locking system out, then proceed in demounting the hoop. 2 Pull the FOSC cover upwards out, installation could begin. Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof. Hoop(left) Hoop(right) Hoop connector Hoop fixing bolt Grommet Hoop locking system Splitter tray Fixing slot of PLC splitter Fiber holding tray Adapter plate FOSC cover 90 ã FOST Fiber Optic Splice Closure Grommet Label Base FOST cover Big gasket ring Entry/exit tube Nut(plastic) Drawing 1 5

5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC 5.2.1 1. Fiber cable in 120mm length: the distance from small gasket ring to fiber cable Pressboard 2. Fiber cable in 1750mm length: it is used to be winded and spliced after stripping. 3. in 150mm length: the distance from the fixing point of fiber cable to the fixing point of FOST (fiber optic splice tray). 4. Fiber in 1600mm length: after stripping off the, it is to be winded inside the FOST after splicing with other fibers 5.2.2 See Drawing 2 Important issues: 1. Reserve enough length of fiber cable to be spliced. 2. Stripping length also could be decided by customers according to Installation requirement 120mmfixing length of fiber cable inside FOSC 1750mmlength of of fiber cable to be stripped off 150mmlength of fiber with (from cable fixing point to FOST fixing point) Fiber cable 1600mmlength of of fiber to be stripped off (Fusion with other fibers and be winded after being striped off ) Temp. locating mark Drawing 2-1 105mmfixing length of fiber cable inside FOSC 150mmlength of fiber with (from cable fixing point to FOST fixing point) 100mmlength of fiber with Fiber cable 1600mmlength of of fiber to be stripped off (Fusion with other fibers and be winded after being striped off) Temp. locating mark 1850mmlength of of fiber to be stripped off (straight through after being winded) Drawing 2-2 Temp. locating mark 5.3 Step three Strip off of fiber cable and fiber 5.3.1 Strip off of fiber cable from the temp. Locating mark with the cutter and the stripper, please refer to Drawing 2 for stripping length. Stripping length also could be decided according to installation requirement 5.3.2 See Drawing 3. Important issues: If it is difficult to pull all the of fiber cable at one time, strip it off section by section to avoid fiber breakage. 6

S t r i E n t r y t e r m T e m p. l o c D r a w C u t t e Step Four Separate fiber cores and prepares work prior to fixing fiber cable. 5.4.1 Wind 2 layers of insulation tape on of fiber core for protection. Meanwhile, get rid of the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber cable temporarily by adhesive tape. There can be two methods of stripping off as follows: 1) For branching drop cable in small inlet/outlet ports, after deciding number of drop cable entry/exit, demount the nut, gasket and seal ring of the corresponding entry/exit tubes according to the diameters of drop cables actually to be installed, insert them into drop cable in sequence, enlarge the diameter with seal tape to make it same as drop cable adaptor, and insert it into porous seal ring; then insert seal ring into entry/exit cable, tighten the nut in order to seal properly. 2) Some fibers uncut are for straight-through after being fixed and winded, fibers cut off are for branching after fusion splicing with fibers of other branching fiber cable. When some fibers uncut are for straight-through, the mass inlet/outlet port should be chosen. 5.4.2 Reserve reinforced core in 70mm length and cut off the unnecessary ones. 5.4.3 See Drawing 4-A. 4-B. Important issues:entry/exit tubes are to be selected accurately to make it easy for splicing and sealing. Seal tape Drop cable adaptor Seal ring Seal tape Drop cable Drop cable Drop cable Drawing 4-A 7

Adhesive tape Adhesive tape Fiber Reinforced core Fiber 70mm Fiber cable Fiber cable 8 5.5 Fix reinforced core, drop cable and pyrocondense, fix and seal fiber cable. 5.5.1 For branching fiber cable in small inlet/outlet ports, after deciding number of fiber Reinforced core cable entry/exit, demount the nut, gasket and gasket ring of the corresponding entry/exit tubes according to the diameters of fiber cables actually to be installed, insert them into fiber cable in sequence, then insert fiber cables into entry/exit cable, tighten the nut in order to seal properly. 5.5.2 For branching fiber cable in big inlet/outlet ports: I demount the big nut, take out gasket and seal ring; II bend cable with sleeves to U shape and insert it into gasket and nut ;III cut duplex port seal ring obliquely from its outside, lead in straight-through fiber; IV While diameter is not big enough, enlarge the diameter with seal tape to make it same as seal ring, and fix it on duplex port seal fitting; V put the seal ring, gasket and cable together into inlet/outlet port, tighten the nut to ensure good sealing, at the same Fiber cable Fiber Drawing 4-B

time,twist straight-through fiber on the holding tray. VI while one cable is through the big inlet/outlet port, only tightening the nut is ok. 5.5.3 Fix fiber cable to the fixing seat, press it with the pressboard. While diameter is small, enlarges the diameter with insulation tape at the fixing position of fixing seat. 5.5.4 Demount the nut of fixing device of reinforced core with special wrench (plastic one), set reinforced core into fixing slot, tighten the nut, retighten it with metal wrench (metal wrench to be provided by operator). Important issue: Fixing nut of reinforced core should be tightened. See Drawing 5 Adhesive tape Fiber Fiber Big gasket ring Pressure testing valve Small gasket ring Gasket(plastic) Nut(plastic) Drop cable Bracket Big gasket ring Gasket(plastic) Nut(plastic) Earthing deriving device Entry/exit tube Fiber cable Drawing 5 Adhesive tape Fixing device for reinforced core Reinforced core Fiber FOST Fiber holding tray Adapter plate 5.6 Step six - Splice fibers 5.6.1 Follow user manual of fusion splicing machine to splice fiber. Important issue: pay attention to the twist and bend of fiber 9

5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers. 5.7.1 When having completed splicing the fibers, the first fiber ring should be housed On the farthest side of FOST, the remaining fiber should be winded, forming a ring With diameter not less than 60mm. then put it into FOST (Fiber Optic Splice Tray) Together with heat shrinkable protective sleeve. (Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.) 5.7.2 This closure suitable for 1*16 PLC splitter, it can be fix in the tray slot, also can stick in the tray by special glue. It can be installed on left side of s the splitter tray. 5.7.3 See Drawing 6-A,6-B Important issue: pay attention to the twist and bend of fiber. FOST Fiber (bunchy or ribbon) Heat shrinkable protective sleeve Fixing slot of heat shrinkable protective sleeve(bunchy or ribbon) Fiber(bunchy or ribbon) Nylon tie Nylon tie Drawing 6-A 10

Fixed optical splitter tray Fiber (bunchy or ribbon) PLC splitter Nylon tie Nylon tie Drawing 6-B 5.8 Step Eight - Check up comprehensively To ensure the technical requirements, the following instructions must be followed: 5.8.1 Fibers with are fixed with nylon tie at the entrance of FOST. 5.8.2 Grommet should be pressed from inside to outside in order to properly install FOST. 5.8.3 If there are fibers with reserved, wind it into the fiber holding tray. 5.8.4 Put Weld pigtail adapter plugged into the fixed module and use nylon ties put drop cables fixed. 5.8.5 Check whether the internal tighteners and reinforced core are well tightened. 5.8.6 Check whether gasket ring is installed neatly and smoothly without any breakage. If not, level it up with seal tape. 5.8.7 See Drawing 7. Important issues: If any problems occur, they should be solved right away. 11

Grommet FOST cover FOST Fiber holding tray Pigtail Adapter Adapter plate Fixing shelf for FOST Fixing device for reinforced core Reinforced core Fixing seat Base Big gasket ring Bracket Pressboard Entry/exit tube Nut(plastic) Drop cable Fiber cable Fiber cable Drawing 7 5.9 Step Nine Assemble FOSC housing and fix FOSC 5.9.1 Put desiccant into FOSC 5.9.2 Put FOSC cover on base directly. 5.9.3 Install plastic hoop between FOSC cover and the base, tighten hoop locking system, 12

Which is to be fixed by hoop fixing bolt then? 5.9.4 All nuts (plastic ones) of base need to be retightened once more. 5.9.5 FOSC installation 1 Aerial application: Fix metal hoop and transom to the pole. Please refer to Drawing 8 2 Wall mounting application: Fix the bracket on the wall with the bolt. (Metal hoop is not required.) 3 Underground application: Metal hoop is not required. 5.9.6 See drawing 8 Important issues: 1. Pay attention while installing plastic hoop. 2. The specification of the bolt for wall-mounting is M8. FOSC cover Hanging hook Hoop(metal) Fiber Optic Splice Closure Hoop fixing bolt Lable Hoop locking system Hoop(left) Transom(metal) Bracket Hoop(right) Nut(plastic) Base Nut(plastic) Drop cable Drawing 8 13

6. Fiber Optic Splice Closures (FOSC) inspecting and testing items Inspecting item Package Appearance Sign Fiber storage device Electrical jointing device Sealing performance Re-sealing performance Pull Punching Technical Requirements Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. There is a clear sign on the housing, such as name and model of the product, etc. The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. Inside FOSC: metallic components of fiber cables have the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, and then observed for 24 hours, there should be no change of air pressure. After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, and then observed for 24 hours, there should be no change of air pressure. Bearing pull is 800N at axle orientation, there should be no breakage on the housing. Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Inspecting type Routine test (Before leaving Type test factory) full At least 3 sets sampled each time At least 3 sets sampled each time 14

Impact Bending Torsion Temperature circle Voltage resistance strength Isolating resistance Bearing impact energy of 16N m, 3 times of impacts there should be not breakage on the housing The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±45 0 for 10 circles, there should be no breakage on the housing Bearing torsion 50N m, 10 circle at torsion angle±90 0, There should be no breakage on the housing. Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40 ~+65, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is 5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be 2 10 4 MΩ. At least 3 sets sampled each time At least 3 sets sampled each time 15