Horizontal Fiber Optic Splice Closure (FOSC) Installation Manual

Similar documents
B1-OPCL Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) FOSC-GPJ-A024. Installation Manual

SNR-FOSC-H. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-H. Installation Manual

HSC-O1. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC)

SNR-FOSC-D. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-D. Installation Manual

SNR-FOSC-F. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-F. Installation Manual

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual

SNR-FOSC-D-T. Installation Manual SNR-FOSC-D-T. Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

FOSCHF Horizontal Fiber Optic Splice Closure

FOSC-400A4 INSTALLATION INSTRUCTION

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

Fiber optic splice closure

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

FOSC-100 B/H FOSC-100 B2/H

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

OPTICAL FIBER CLOSURE

3000SC Fiber Optic Splice Closure

3M Fiber Dome Closure FDC 10

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

19 1HU Splicing and Front Patching Shelf

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Cargo Socket Kit. Securely connect connectors and terminals. Failure to do so can result in poor connections.

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

COYOTE LCC (Low Count Closure)

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

8400 Series Fiber Distribution System

CS Fiber Optic Splice Case. Instruction

Closure End Plates and Accessories

FLOODLIGHT unit IMPORTANT WARNING! RRAC055/RRAC059. INSTALL TIME: 30 mins

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

Power Connection Kit installation instructions

B Polyethylene Tape. B Splicing Covering. Holster

Universal Splice Tray Installation Instructions

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W Trailer Hitches 1216 Hawaii Road / PO Box 186 Humboldt, KS P: F:

Section 3 FIBERLIGN Closure Series

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Fiber Connector Shelf (CCS)

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

Southwest Windpower Instruction Sheet AIR-X Circuit Replacement Kit

Read these instructions thoroughly before attempting to install this option.

TOYOTA TACOMA XM SATELLITE RADIO Preparation

insulated sectional 2180mm (h) x 2550mm (w) Opening Size: 2140mm (h) x 2500mm (w) suits single car garage

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

WRSS Wraparound Repair Sleeve Installation Instructions

Section II - Installation Procedures Part Number : Accessory Code IL1 Kit Contents. Color Applicability/Trim Level. Hardware Bag Contents

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Series 3 & 4 Stainless Steel - Accessories

Toyota Prius Interior Light Upgrade

Opticom Rack Mount Fiber Enclosures

Smittybilt XRC Rear Bumper Installation Guide Part # 76856

Heat Shrink closure Non - Pressurized & Pressurized RTSM Dome Closure RLSS RPBS Vault Closure Lead Sleeve Mechanical Closure Pillar Dp Jointing Kit

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

TOYOTA SIENNA TRAILER WIRE HARNESS Preparation

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

COYOTE Terminal Dome Closure 6.5" x 22"

INSTALLATION INSTRUCTIONS

TOYOTA SOLARA EC REARVIEW MIRROR Section I - Installation Preparation

ET-PWR-END-KIT Installation Instructions (part #JSR00)

TOYOTA HIGHLANDER TRAILER WIRE HARNESS Preparation

HD BULL NOSE FRONT BUMPER FORD SUPERDUTY F PARTS LIST:

No. Tool Vendor P/N. Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL.

RAV4 TNS310 (Traffic) Plus

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

HANDLING OF ASSEMBLY... 1 RRH END OF ASSEMBLY... 1 BASE STATION END OF ASSEMBLY... 7 POWER CODING REVISION HISTORY... 11

INSTALLATION INSTRUCTIONS

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

C A Heating Cable Gland Kit Installation Instructions

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Toyota Venza Interior Light Upgrade

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Terminator DP/FAK-5 and FAK-5L

Environmental Distribution Center (EDC-06P-NH)

PARTS LIST: ELEVATION BULL NOSE FRONT BUMPER FORD SUPERDUTY F

MNBRATKIT MidNite Brat Solar Charging Kit

4. Front and Rear Drive Shafts

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

DARMAN. ENDURA II Cloth Towel Cabinet Product Guide. Manufacturing Company, Inc Lincoln Ave., Utica, NY 13502

Banks SmartLock. THIS MANUAL IS FOR USE WITH system 55270

SCION xb 2004 SECURITY (V5) Section I Installation Preparation. Part Number:

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Previa (RHD) - MMC PZ425-R PART NUMBER INSTALLATION INSTRUCTIONS TOYOTA NAVIGATION SYSTEM. (Production date 05/03)

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Section 5: Parts Replacement

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Installation or Inspection Checklist

Transcription:

Horizontal Fiber Optic Splice Closure (FOSC) Installation Manual

1. Scope of application Installation Manual for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC). The scope of application is: aerial, underground, pipeline, handhole. The ambient temperature ranges from -40 to 65. 2. Basic structure and configuration 2.1 Dimension and capacity Outside dimension (L x W x H) Weight (excluding outside box) Number of inlet/outlet ports Diameter of fiber cable Capacity of FOSC (Dependent on Model Size) 450x216x160 (mm) 3100g-3800g 3 (pieces) on each side (total 6 pieces) Φ8 Φ23 (mm) Distribution: 12 192 (Cores) Ribbon: max. 432(Cores) 2.2 Main components No. Name of Quantity Usage Remarks components 1 Housing 1 set Protecting fiber cable splices in whole Internal diameter: 378x136 (mm) 2 Insert plate 2 pairs Fixing the housing 175x56x30(mm) 3 Fiber optic Max 8 for Fixing heat shrinkable protective splice tray (Distribution) sleeve and holding fibers (FOST) or 6 for ( ribbon) 4 Foundation 1 set Fixing reinforced core of fiber cable and fiber optic splice tray (FOST) Suitable for: Distribution: 12,24(cores) Ribbon:6 (pieces) 5 Seal fitting 1 set Sealing between FOSC cover and FOSC bottom 6 Port plug 6 pieces Sealing empty ports 7 Pressure testing valve 1 set After injecting air it is used for pressure testing and sealing testing Configuration as per requirement 1

8 Earthing deriving device 1 set Deriving metallic components of fiber cable in the FOSC for earthing connection Configuration as per requirement 2.3 Main accessories and special tools No. Name of accessories Quantity Usage Remarks 1 Heat shrinkable protective sleeve Based on Model size Protecting fiber splices Configuration as per capacity 2 Nylon tie Fixing fiber with protective coat 3 Insulation tape 1 roll Enlarging diameter of fiber cable for easy fixing 4 Seal tape 1 roll Enlarging diameter of fiber cable which fits in with seal fitting 5 Hanging hook 1 set For aerial use 6 Earthing wire 1 piece Putting through between earthing device 7 Abrasive cloth 1 piece Scratching External Jacket 8 Labeling paper 1 piece Labeling fiber 9 Special Wrench 3 pieces Fixing bolts and tightening nut of reinforced core 10 Measuring paper 1 piece To measure circle, of which its diameter is enlarged with seal tape 11 Buffer tube To be decided Hitched to fibers and fixed by customers with FOST, managing buffer 12 Desiccant 1 bag Put into FOSC before sealing for desiccating air. Configuration as per capacity Configuration as per specification Configuration as per requirement to be provided by operator 3. Necessary tools for installation 3.1 Supplementary materials (to be provided by operator) Name of materials Scotch tape Ethyl alcohol Gauze Usage Labeling, temporarily fixing Cleaning Cleaning 3.2 Special tools (to be provided by operator) 2

Name of tools Fiber cutter Fiber stripper Combo tools Usage Cutting off fibers Strip off protective coat of fiber cable Assembling FOSC 3.3 Universal tools(to be provided by operator) Name of tools Usage and specification Band tape Fiber cutter Electrical cutter Combination pliers Screwdriver Measuring fiber cable Cutting fiber cable Take off protective coat of fiber cable Cutting off reinforced core Crossing/Paralleling screwdriver Scissor Waterproof cover Metal Wrench Waterproof, dustproof Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator) Name of instruments Usage and specification Fusion Splicing Machine OTDR Provisional splicing tools Fiber splicing Splicing testing Provisional testing Notice: The above-mentioned tools and testing instruments are required for proper termination. 3

4.Installation flow chart 1. Open the closure 2. Determine length of fiber cable to be fixed and stripped inside FOSC 3. Strip off protective coats of fiber cable and fiber 4. Separate fiber cores and prepare work prior to fixing fiber cable 5. Fix reinforced core and fiber cable 6. Splice fibers 7. Install heat shrinkable protective sleeve and house fibers 8. Test & Check all connections 9. Assemble FOSC housing 10.Fix FOSC 4

5. The process of installing FOSC 5.1 Step One - Open the closure 5.1.1 Cleaning the locale and determine where to install the FOSC and then place fiber cables required. 5.1.2 Check whether the main components and accessories have been well prepared inside the package. 5.1.3 Open the closure 1. Demount the fixing bolt of insert plate with a special wrench. Put the fixing bolt into the hole of screw thread next to the fixing hole of the insert plate and push the insert plates out with the special wrench. 2 Use the special wrench to demount all the locating bolts on the housing as well as fixing bolts (it is also possible to install hanging hook depending on the installation requirement) at four corners, then proceed in opening the closure. 5.1.4 See Drawing 1 Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof. Insert plate Single fiber cable pressboard Fixing bolt Cover for seal fitting Fixing device for reinforced core Foundation Port plug A Locating bolt Port plug B Port plug C Earthing device Double fiber cable pressboard Seal fitting FOSC bottom Bolt for insert plate FOST cover FOSC cover Shaft Drawing 1 Fixing bolt Locating bolt 5

5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC 5.2.1 1. Fiber cable in 70mm length: the distance from seal fitting to fiber cable pressboard 2. Fiber cable in 2030mm length: it is used to be winded and spliced after stripping. 3. Fiber with protective coat in 430mm length: the distance from the fixing point of fiber cable to the fixing point of FOST (fiber optic splice tray). 4. Fiber in 1600mm length: after stripping off the protective coat, it is to be winded inside the FOST after splicing with other fibers 5.2.2 See Drawing 2 Important issues: 1. Reserve enough length of fiber cable to be spliced. 2. Stripping length also could be decided by customer according to installation requirement. Fiber cable 1. Fixing length of fiber cable inside FOSC 2. 2030mm length of protective coat of fiber cable to be stripped off 3. 430mm length of fiber with protective coat 4.1600mm length of protective coat of fiber to be stripped Drawing 2 5.3 Step Three Strip off fiber protective coat of fiber cable and fiber 5.3.1 Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the stripper. Please refer to Drawing 2 for stripping length. Stripping length also could bedecided according to installation requirement 5.3.2 See Drawing 3. Important issues: If it is difficult to pull all the protective coat of fiber cable at one time, stript it off section by section to avoid fiber breakage. Temp. locating mark Stripping terminal fiber cable Fiber cable Cutter Drawing 3 5.4 Step Four Separate fiber cores and prepare work prior to fixing fiber. 5.4.1 Wind 2 layers of insulation tape on protective coat of fiber core. Meanwhile, get rid of the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and fix it on 6

the fiber temporarily by adhesive tape. 5.4.2 This FOSC is provided with six inlet/outlet ports. Number of fiber cables is determined by the customers according to their actual requirements and the corresponding number of port plugs should be taken out. The max number of fiber cables to be installed is six. 5.4.3 This FOSC is suitable for the following diameters of fiber cables respectively: Port A: suitable for fiber cable with max. external diameter ф23mm Port B: suitable for fiber cable with max. external diameter ф20mm Port C: suitable for fiber cable with max. external diameter ф16mm 5.4.4 The corresponding inlet/outlet ports are to be selected according to fiber cables actually installed. When the diameter of fiber cable is smaller than that of the inlet/outlet port, then the sealing tape should be used to enlarge the external diameter of fiber cable, which could be measured by measuring paper marked by Hole A, Hole B, Hole C, coming as accessories. 5.4.5 Reserve reinforced core in 40mm length and cut off the unnecessary ones. 5.4.6 See Drawing 4 Important Issues: 1. Before the seal tape is used for enlarging the fiber cable diameter, it should be scratched and to be cleaned with abrasive cloth and ethyl alcohol. 2. Cut off reinforced core with a special cutting plier. Adhesive tape Seal tape Insulation tape 5~10 Reinforced core Drawing 4 Fiber bunchy/ribbon fiber (with protective coat) 5.5 Step Five - Fix reinforced core and fiber cable 5.5.1 Upon finishing the above steps, then demount port plugs, pressboard and fixing nut of reinforced core. Make sure to check whether the fiber cable stripped fits in with the fixing ports or not. If not, the adjustment should be done at this time. Otherwise it will installation quality. 5.5.2 Tighten fiber cable pressboard. If the diameter of fiber cable is not long enough, then enlarge it with insulation tape. 5.5.3 Tighten nut of reinforced core with the special wrench (plastic one) and then retighten it with a metal wrench (the metal wrench should be provided by operator). 5.5.4 See Drawing 5 affect 7

B olt for fixing fiber cable N ut for reinforced core Fiber cable pressboard Fiber cable S eal fitting Housing Fixing device for fiber cable Fiber Fixing device for reinforced core Drawing 5 5.6 Step Six - Splice fibers 5.6.1 Follow user manual of fusion splicing machine to splice fiber cores. Important issue: pay attention to the twist and bend of fiber. 5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers 5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve. ( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.) 5.7.2 see Drawing 6 Important issue: pay attention to the twist and bend of fiber Nylon tie Fixing slot of heat shrinkable protective sleeve (bunchy) Grommet Heat shrinkable protective sleeve Fixing slot of heat shrinkable protective sleeve (Ribbon) Left terminal fiber with protective coat Fiber FOST Right terminal fiber with protective coat Drawing 6 8

5.8 Step Eight - Check up comprehensively To ensure the technical requirements, the following instructions must be followed: 5.8.1 The fibers in the FOST are spliced and installed orderly. The curved diameter of fiber meets with the technical requirements. 5.8.2 The internal tighteners are tightened. 5.8.3 The inlet/outlet ports without fiber cables must be blocked up with the port plugs. 5.8.4 Control the amount of seal tape within a proper range. 5.8.5 Seal fitting is installed neatly and smoothly. If not, level it up with insulation tape. 5.8.6 Seal the cover of seal fitting 5.8.7 See Drawing 7 Grommet FOST cover FOST Terminal B fiber with protective coat Fiber with protective coat Fixing device for reinforced core Fiber Terminal A fiber cable Seal tape Insulation tape Port plug B Reinforced core FOST Grommet Earthing device Nylon tie Nylon tie Terminal A fiber with protective coat Fixing slot of heat shrinkable protective sleeve Heat shrinkable protective sleeve Single fiber cable pressboard Seal fitting Seal tape Terminal B fiber cable Seal fitting Port plug B Port plug C Double fiber cable pressboard Drawing 7 9

5.9 Step Nine Assemble FOSC housing 5.9.1 Put the FOSC cover on the FOSC bottom directly. 5.9.2 Insert locating bolt of FOSC and tighten it with the special wrench. 5.9.3 Put the insert plates into the slot (one pair on each side, one piece with a hole with screw thread in the middle, the other with a hole without screw thread in the middle). Tighten bolts of insert plate with the special wrench. 5.9.4 If the FOSC is for aerial application, then put the hanging hook on one side of the closure and then tighten fixing bolts on both sides. Otherwise tighten the four fixing bolts on four corners respectively. 5.9.5 See drawing 8 Important issues: cleaning the housing and pay attention to the above sequence. Locating bolt Pressure testing valve Insert plate FOSC cover Bolt of insert plate Fixing bolt (at 4 corners) Insert plate FOSC bottom Bolt for insert plate Earthing deriving device Demounting hole with female thread on insert plate Fixing bolt Cover of seal fitting Single Fiber cable pressboard Fixing device for reinforced core Foundation FOST cover FOSC cover Fixing bolt Port plug A Locating bolt Locating bolt Port plug B Port plug C Earthing device Double fiber cable pressboard Seal fitting FOSC bottom Panel Drawing 8 Locking hole with female thread on insert plate Port A Port B Port C Fixing slot for hanging hook 10

5.10 Step Ten - Fix FOSC 5.10.1 Fixing the FOSC and tighten bolts in sequence as per drawing 9. Important issues: 1. Retighten in five minutes 2. Tighten properly to avoid the closure to be out of shape. 12. Port A 2. 10. 4. 5. 7. 3. Drawing 9 8. 6. 11. 1. 9. Port A Port B Port C 11

6. Fiber Optic Splice Closures (FOSC) inspecting and testing items Inspecting item Package Appearance Sign Fiber storage device Electrical jointing device Sealing performance Re-sealing performance Pull Technical Requirements Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. There is a clear sign on the housing, such as name and model of the product, etc. The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa± 5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Bearing pull is 800N at axle orientation, there should be no breakage on the housing. Inspecting type Routine test (Before leaving Type test factory) full At least 3 sets sampled each time At least 3 sets sampled each time 12

Punching Impact Bending Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Bearing impact energy of 16N m, 3 times of impacts there should be not breakage on the housing The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±45 0 for 10 circles, there should be no breakage on the housing Torsion Bearing torsion 50N m, 10 circle at torsion angle±90 0, There should be no breakage on the housing. Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40 ~+65, 10 times of the circular Temperature circle tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is 5Kpa, immerse the swatch in clean water of normal temperature for 15 At least 3 sets sampled each time At least 3 sets sampled each time minutes, there should be no air bubbles. After sealing the FOSC according to the stipulated Voltage resistance strength operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. Isolating After sealing the FOSC according to stipulated operation resistance procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be 2 10 4 MΩ. 13