Compliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT.

Similar documents
TEST REPORT. according to COMMISSION DIRECTIVE 2009/19/EC. Equipment : In Vehicle Computer. Model No. : VBOX-3200-XXXXX

Page 2 of 23 UNT150420C11

SGS TEST REPORT. Page: 1 of 8 Date: April 15,2010. itech Company LLC Christy Street, Fremont CA USA

THERMAL SHOCK TEST REPORT

65W. * Fully. and Fixed. *Meet. *Brand

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

Background. Voltage Transient Emission Setup Requirement. Transient Immunity Setup up Requirement Performance Criteria ISO :2004.

SGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA

Environmental Test Report

UL TEST REPORT AND PROCEDURE

TEST EQUIPMENT USED. Part , ANSI C63.4, RSS 210

Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

SAFETY COMPLIANCE TESTING FOR FMVSS 124 ACCELERATOR CONTROL SYSTEMS

USB3.0 For Active Optical Cable SPECIFICATIONS

USB3.0 for Active Optical Cable

USB3.0 For Active Optical Cable SPECIFICATIONS

SINGLE VOLTAGE EXTERNAL POWER SUPPLY TEST REPORT

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

NATIONAL TECHNICAL SYSTEMS

600 Amp Surge Arrester

REPORT NUMBER: 111SB-MGA SAFETY COMPLIANCE TESTING FOR FMVSS NO. 111SB SCHOOL BUS REARVIEW MIRRORS

EMC TEST REPORT. For The. 3-Phase Power Supply. Model: TPS300024

VIBRATION TEST REPORT

SHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24

SAFETY COMPLIANCE TESTING FOR FMVSS 124 ACCELERATOR CONTROL SYSTEMS

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

DESIGN VERIFICATION TEST REPORT HLE/TSM HLE G-DV/TSM G-DV

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

MEASUREMENT AND TEST REPORT

EMC TEST REPORT For MUST POWER LIMITED. PC1600 Mppt Solar Charge Controller. Model No.: PC F, PC F

TEST REPORT CONCERNING THE COMPLIANCE OF A VOTING MACHINE FOR USE AT ELECTIONS IN IRELAND, BRAND NEDAP, MODEL P.R.U

NATIONAL TECHNICAL SYSTEMS

TEST REPORT. The following merchandise was submitted and identified by the vendor as:

CONTINUOUS IMMERSION AND DUST TEST REPORT

Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger March 16, 2016 (Q022516U1R2) Testing Location

Test Plans & Test Results

Test report. About the effect of Lambda System Cleaning Products. No

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9

Certificate of Calibration

An Overview of Automotive EMC Standards & Emerging Requirements

REPORT NUMBER: 111-MGA SAFETY COMPLIANCE TESTING FOR FMVSS NO. 111 SCHOOL BUS REARVIEW MIRRORS

Digital Insulation Resistance Testers. you can depend on

1201 North Catalina Ave. #818 Redondo Beach, CA (310) FAX (866) Classification of Air Cleanliness

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

Packaging (1) Package

REPORT NUMBER: 111SB-MGA SAFETY COMPLIANCE TESTING FOR FMVSS NO. 111SB SCHOOL BUS REARVIEW MIRRORS

MTC Series. Marine Temperature Calibrator

Load (2) Single or Dual

LISTING REPORT/INSPECTION PROCEDURE

CHANGE NOTICE. 5. Code Ident. 2B945 2B Effectivity All Units

REPORT NUMBER: 111-MGA SAFETY COMPLIANCE TESTING FOR FMVSS NO. 111 SCHOOL BUS REARVIEW MIRRORS

C10325 v1.1. Thanks for your purchasing the intelligent and powerful charger.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

RUZ- _/_ Protection (3) Isolation Option (4)

File No:XSG-NiMHSPEC-R01 1 / 19

CRASH TEST REPORT FOR PERIMETER BARRIERS AND GATES TESTED TO SD-STD-02.01, REVISION A, MARCH Anti-Ram Bollards

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ZF GLOBAL ELECTRONICS- VALIDATION LABORATORY Carl-Spaeter-Str. 8 Koblenz, Germany 56070

Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD

1. INTRODUCTION AND SYSTEM DESCRIPTION SPECIFICATIONS... 5

SAFETY AND COMPLIANCE TESTING FOR SURESTOP

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

Z155, ST3000 Autopilot Service Manual

ELECTRONIC LOAD CATALOG

The FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.

COMPLIANCE TESTING FOR FMVSS 207 SEATING SYSTEMS

SmartSensor 105 & Advance NEMA Salt Fog

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

REPORT NUMBER: 111SB-MGA SAFETY COMPLIANCE TESTING FOR FMVSS NO. 111SB SCHOOL BUS REARVIEW MIRRORS

X11CA-IM MASTER MODULE

PIP REEE003 Guidelines for General Purpose Non-Lubricated Flexible Couplings

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

LIST OF EFFECTIVE PAGES Insert latest changed pages ; dispose of superseded pages in accordance with applicable regulations. NOTE : On a changed page,

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

CHIP FUSE; RECTANGULAR TYPE FCC10,16,20,32, FHC10,16,20,32. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Standard Calibration Certificate

SAMTEC POWER CHARACTERIZATION

YOUR PARTNER FOR IMPULSE EMC EMC PARTNER PRODUCT RANGES. Immunity Lightning Component Emission Automation

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

REPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO.

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Product Name: LCD TV. Inspection location: Inspection date: Your reference number: XXXX. P/O number: Supplier: XXXX. Order quantity: 1744

SAMTEC POWER CHARACTERIZATION

SPECIFICATION FOR APPROVAL

JUNE 11, 2010 TEST REPORT # S2SD CABLE ASSEMBLY QUALIFICATION TESTING PART: T2SD L D-NDS MATING PART: S2M L-D-LC SAMTEC, INC.

CRASH TEST REPORT FOR PERIMETER BARRIERS AND GATES TESTED TO SD-STD-02.01, REVISION A, MARCH Anti-Ram Bollards

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

6125FF Fast-acting subminiature fuses

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

ZE motor-protective relay Overload monitoring of EEx e motors

Transcription:

Compliance Certification Services Inc. MIL STD 461E/ F TEST REPORT For 20.1 Multimedia LCD Monitor Model Number: WMRM920-PIP Trade Name: itech Issued to itech Company LLC 41758 Christy Street, Fremont CA 94538 USA Issued by Compliance Certification Services Inc. No. 11, Wugong 6 th Rd., Wugu Industrial Park Taipei Hsien 248, Taiwan http ://www.ccsemc.com.tw service@tw.ccsemc.com Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page: 35 Rev. 00

Compliance Certification Services Inc. TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION 3 2. EUT DESCRIPTION 4 3. TEST METHODOLOGY 5 4. INSTRUMENT AND CALIBRATION 5 4.1 MEASURING INSTRUMENT CALIBRATION 5 4.2 MEASUREMENT EQUIPMENT USED 5 5. FACILITIES AND ACCREDITATIONS 6 5.1 FACILITIES 6 6. SETUP OF EQUIPMENT UNDER TEST 7 6.1 SETUP CONFIGURATION OF EUT 7 6.2 SUPPORT EQUIPMENT 7 6.3 TEST SETUP 7 7. MIL STD 461E/F REQUIREMENTS 8 7.1 CS101, CONDUCTED SUSCEPTIBILITY, POWER LEADS, 30 HZ TO 150 KHZ 8 8. APPENDIX I PHOTOGRAPHS OF TEST SETUP 35 Page 2 Rev. 00

{{C Compliance Certification Services Inc. \ \ J Report No: 90626003-MIL(CS 101) Dale ot'lssue: August 12. 2009 1. TEST RESULT CERTIFICATION Applicant: itech Company LLC 41758 Christy Street,Fremont CA 94538 USA Equipment Under Test: Trade Name: Model Number: 20.1 Multimedia LCD Monitor itech WMRM920-PIP Date of Test: July 6. 2009 APPLICABLE STANDARDS STANDARD MIL STD 461E/F Applicable Standard TEST RESULT No non-compliance noted Test Result MIL STD 461 E/F CSIOI: Conducted susceptibility, power leads, 30 Hz to 150 khz. No non-compliance noted Deviation from Applicable Standard N/A The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in MIL STD'461 E/F. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Approved by: Reviewed by: James Lee Section Manager Compliance Certification Services Inc. \7HAfX V^v Bruce Chen Senior Engineer Compliance Certification Services Inc. Page 3 Rev. 00

Compliance Certification Services Inc. 2. EUT DESCRIPTION Product Trade Name Model Number Model Discrepancy EUT Power Rating 20.1 Multimedia LCD Monitor itech WMRM920-PIP MB: itech/r2a Panel LCD: 20.1 AUO / M201UN02-V6 Power Board: Wearnes/ WDS080121 RS232 Port: Link PC /Touch Remark: for more details, please refer to the User's manual of the EUT. Page 4 Rev. 00

Compliance Certification Services Inc. 3. TEST METHODOLOGY All tests were performed in accordance with the procedure documented in MIL STD 461F. 4. INSTRUMENT AND CALIBRATION 4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer s recommendations for utilizing calibration equipment, which is traceable to recognized national standards. 4.2 MEASUREMENT EQUIPMENT USED Equipment Used for Emissions Measurement CS101 (844 Chamber ) Name of Equipment Manufacturer Model Serial Number Calibration Due Continuous Wave Simulator EM-TEST CWS 500E V0606101158 10/01/2010 Software ICD 3.53 Page 5 Rev. 00

Compliance Certification Services Inc. 5. FACILITIES AND ACCREDITATIONS 5.1 FACILITIES All measurement facilities used to collect the measurement data are located at No.199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C. Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029 G No.11, Wugong 6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan Tel: 886-2-2299-9720 / Fax: 886-2-2299-9721 G No.81-1, Lane 210, Bade 2nd Rd., Luchu Hsiang, Taoyuan Hsien 338, Taiwan Tel: 886-3-324-0332 / Fax: 886-3-324-5235 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. Page 6 Rev. 00

Compliance Certification Services Inc. 6. SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP CONFIGURATION OF EUT See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. 6.2 SUPPORT EQUIPMENT No. Device Ty pe Brand Model Series No. FCC ID Data Cable Power Cord 1 Notebook PC DELL PP19L GH645 A03 E2KWM3945ABG N/A N/A Remarks: 1. All the above equipment/cables were placed in worse case positions to maximize emission signals during emission test. 2. Grounding was established in accordance with the manufacturer s requirements and conditions for the intended use. 6.3 TEST SETUP The equipment under test was configured in normal operation continuously. EUT tends to maximize its emission characteristics in a typical application for immunity test. The EUT was active during the immunity test measurements. Page 7 Rev. 00

ccs Compliance Certification Services Inc. 7. MIL STD 461E/F REQUIREMENTS 7.1 CS101, conducted susceptibility, power leads, 30 Hz to 150 khz LIMIT The EUT shall not exhibit any malfunction, degradation of performance, or deviation from specified indications, beyond the tolerances indicated in the individual equipment or subsystem specification, when subjected to a test signal with voltage levels as specified in Figure CS101-1. The requirement is also met when the power source is adjusted to dissipate the power level shown in Figure CS101-2 in a 0.5 ohm load and the EUT is not susceptible. 1k 10k Frequency (Hz) FIGURE CS101-1. CS101 voltage limit for all applications. Page 8 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ FIGURE CS101-2. CS101 power limit for all applications. Page 9 Rev. 00

Compliance Certification Services Inc. CLASSIFICATION OF FUNCTIONAL STATUS All classifications are for the total device/system functional status. Class A: all functions of a device/system perform as designed during and after exposure to disturbance. Class B: all functions of a device/system perform as designed during exposure. However, one or more of them can go beyond specified tolerance. All functions return automatically to within normal limits after exposure is removed. Class C: one or more functions of a device/system do not perform as designed during exposure but return automatically to normal operation after exposure is removed. Class D: one or more functions of a device/system do not perform as designed during exposure and do not return to normal operation until exposure is removed and the device/system is reset by simple operator/use action. Class E: one or more functions of a device/system do not perform as designed during and after exposure and cannot be returned to proper operation without repairing or replacing the device/system. NOTE: The word function in this context refers only to the function performed by the electronic system. Page 10 Rev. 00

ccs Compliance Certification Services Inc. TEST CONFIGURATION FIGURE CS101-4. Signal injection, DC or single phase AC FIGURE CS101-5. Signal injection, 3-phase ungrounded. Page 11 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ FIGURE CS101-6. Signal injection, 3-phase wye. TEST PROCEDURE The magnetic emission of EUT representative of its type shall be tested by the method(s) according to MIL STD 461E/F. Page 12 Rev. 00

Compliance Certification Services Inc. TEST RESULTS No non-compliance noted Te s t Dat a Te s t EUT Power Test Te s t Sequence (Vac) Curve(#) Result Remark L1 110 1 A Normal function L2 110 1 A Normal function L3 110 1 A Normal function Page 13 Rev. 00

ccs Compliance Certification Services Inc. LI to L2 test data: Test center CCS TEST REPORT Report No. : 90626003 Standard MILSTD-461E/FCS101 Test object 20.1 Multimedia LCD Monitor WMRM920-PIP Customer itech Company LLC Test engineer Eric Recorded July 6, 2009 3:57:54 pm, with ICD 3.50.11 Test equipment 1.) EM TEST AG, CWS 500E, RE9E0E9Q9A Result file C:\EMTEST\ICD350\RESULT\11.prj Description Class : A Result Test passed Testfile Name Path curve 1 136dbuv ac 5%.nrm c:\emtest\icd350\standard\automotive\internat 9589\mil-std-461f\complate\cs101\curve 1 136dbuv ac 5%.nrm Modification date 2009/7/2 nwne 11:48:52 Climatic condition Temperature 23 Humidity 54 Pressure 1020 Test Values no. title F1 [khz] L1 F2 [khz] L2 F-step [khz] td[s] tp[s] Modulation [dbuv] [dbuv] 1. Curve #1 0.030 5.000 5.0 % 3.0 s 0.0 s CW 2. 5.000 150.000 106.5 5.0 % 3.0 s 0.0 s CW Page 14 Rev. 00

ccs Compliance Certification Services Inc. Diagrams Test summary no. Calibration file Tp. count Ev. count passed 1. Trafo2-1 Curve #1 0_03-150_0 khz, 5_0 %.CAL Coupling device: 1 176/177 1 no Model Sno Note Frequency range Coupling port description Trafo2-1 60VAC, 50ADC max 0.010.. 250.000 khz DC-Port Diagrams Page 15 Rev. 00

Compliance Certification Services Inc. Table of events : 1 no. Events Frequency Level Comment [khz] [dbuv] 1 Stop 150.000 106.5 Table of Test points : 176 no. Frequency Level [dbuv] [khz] 1 0.030 2 0.032 3 0.034 4 0.036 5 0.038 6 0.040 7 0.042 8 0.044 9 0.046 10 0.048 11 0.050 12 0.052 13 0.055 14 0.058 15 0.061 16 0.064 17 0.067 18 0.070 19 0.074 20 0.078 21 0.082 22 0.086 23 0.090 24 0.094 25 0.099 26 0.104 27 0.109 28 0.114 29 0.120 30 0.126 Page 16 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 31 0.132 32 0.139 33 0.146 34 0.153 35 0.161 36 0.169 37 0.177 38 0.186 39 0.195 40 0.205 41 0.215 42 0.226 43 0.237 44 0.249 45 0.261 46 0.274 47 0.288 48 0.302 49 0.317 50 0.333 51 0.350 52 0.368 53 0.386 54 0.405 55 0.425 56 0.446 57 0.468 58 0.491 59 0.516 60 0.542 61 0.569 62 0.597 63 0.627 64 0.658 65 0.691 66 0.726 67 0.762 68 0.800 Page 17 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 69 0.840 70 0.882 71 0.926 72 0.972 73 1.021 74 1.072 75 1.126 76 1.182 77 1.241 78 1.303 79 1.368 80 1.436 81 1.508 82 1.583 83 1.662 84 1.745 85 1.832 86 1.924 87 2.020 88 2.121 89 2.227 90 2.338 91 2.455 92 2.578 93 2.707 94 2.842 95 2.984 96 3.133 97 3.290 98 3.454 99 3.627 100 3.808 101 3.998 102 4.198 103 4.408 104 4.628 105 4.859 107 5.000 Page 18 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 108 5.250 135.6 109 5.512 135.1 110 5.788 134.7 111 6.077 134.3 112 6.381 133.9 113 6.700 133.5 114 7.035 133.0 115 7.387 132.6 116 7.756 132.2 117 8.144 131.8 118 8.551 131.3 119 8.979 130.9 120 9.428 130.5 121 9.899 130.1 122 10.394 129.6 123 10.914 129.2 124 11.460 128.8 125 12.033 128.4 126 12.635 127.9 127 13.267 127.5 128 13.930 127.1 129 14.626 126.7 130 15.357 126.3 131 16.125 125.8 132 16.931 125.4 133 17.778 125.0 134 18.667 124.6 135 19.600 124.2 136 20.580 123.7 137 21.609 123.3 138 22.689 122.9 139 23.823 122.4 140 25.014 122.0 141 26.265 121.6 142 27.578 121.2 143 28.957 120.8 144 30.405 120.3 145 31.925 119.9 Page 19 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 146 33.521 119.5 147 35.197 119.1 148 36.957 118.7 149 38.805 118.2 150 40.745 117.8 151 42.782 117.4 152 44.921 116.9 153 47.167 116.5 154 49.525 116.1 155 52.001 115.7 156 54.601 115.3 157 57.331 114.8 158 60.198 114.4 159 63.208 114.0 160 66.368 113.6 161 69.686 113.1 162 73.170 112.7 163 76.828 112.3 164 80.669 111.9 165 84.702 111.4 166 88.937 111.0 167 93.384 110.6 168 98.053 110.2 169 102.956 109.8 170 108.104 109.3 171 113.509 108.9 172 119.184 108.5 173 125.143 108.1 174 131.400 107.6 175 137.970 107.2 176 144.868 106.8 177 150.000 106.5 Page 20 Rev. 00

ccs Compliance Certification Services Inc. L2to L3 test data: Test center CCS TEST REPORT Report No. : 90626003 Standard Test object MILSTD-461E/FCS101 20.1 Multimedia LCD Monitor WMRM920-PIP Customer Test engineer itech Company LLC Eric Recorded July 6, 2009 4:28:45 pm, with ICD 3.50.11 Test equipment Result file Description Result 1.) EM TEST AG, CWS 500E, RE9E0E9Q9A C:\EMTEST\ICD350\RESULT\11.prj Class : A Test passed Testfile Name Path curve 1 136dbuv ac 5%.nrm c:\emtest\icd350\standard\automotive\internat 9589\mil-std-461f\complate\cs101\curve 1 136dbuv ac 5%.nrm Modification date 2009/7/2 nwne 11:48:52 Climatic condition Temperature 23 Humidity 54 Pressure 1020 Te st Values no. title F1 [khz] L1 F2 [khz] L2 F-step [khz] td[s] tp[s] Modulation [dbuv] [dbuv] 1. Curve #1 0.030 5.000 5.0 % 3.0 s 0.0 s CW 2. 5.000 150.000 106.5 5.0 % 3.0 s 0.0 s CW Page 21 Rev. 00

ccs Compliance Certification Services Inc. Diagrams Test summary no. Calibration file Tp. count Ev. count passed 1. Trafo2-1 Curve #1 0_03-150_0 khz, 5_0 %.CAL Coupling device: 1 176/177 1 no Model Sno Note Frequency range Coupling port description Trafo2-1 60VAC, 50ADC max 0.010.. 250.000 khz DC-Port Diagrams Page 22 Rev. 00

Compliance Certification Services Inc. Table of events : 1 no. Events Frequency Level Comment [khz] [dbuv] 1 Stop 150.000 106.5 Table of Test points : 176 no. Frequency Level [dbuv] [khz] 1 0.030 2 0.032 3 0.034 4 0.036 5 0.038 6 0.040 7 0.042 8 0.044 9 0.046 10 0.048 11 0.050 12 0.052 13 0.055 14 0.058 15 0.061 16 0.064 17 0.067 18 0.070 19 0.074 20 0.078 21 0.082 22 0.086 23 0.090 24 0.094 25 0.099 26 0.104 27 0.109 28 0.114 29 0.120 30 0.126 Page 23 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 31 0.132 32 0.139 33 0.146 34 0.153 35 0.161 36 0.169 37 0.177 38 0.186 39 0.195 40 0.205 41 0.215 42 0.226 43 0.237 44 0.249 45 0.261 46 0.274 47 0.288 48 0.302 49 0.317 50 0.333 51 0.350 52 0.368 53 0.386 54 0.405 55 0.425 56 0.446 57 0.468 58 0.491 59 0.516 60 0.542 61 0.569 62 0.597 63 0.627 64 0.658 65 0.691 66 0.726 67 0.762 68 0.800 Page 24 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 69 0.840 70 0.882 71 0.926 72 0.972 73 1.021 74 1.072 75 1.126 76 1.182 77 1.241 78 1.303 79 1.368 80 1.436 81 1.508 82 1.583 83 1.662 84 1.745 85 1.832 86 1.924 87 2.020 88 2.121 89 2.227 90 2.338 91 2.455 92 2.578 93 2.707 94 2.842 95 2.984 96 3.133 97 3.290 98 3.454 99 3.627 100 3.808 101 3.998 102 4.198 103 4.408 104 4.628 105 4.859 107 5.000 Page 25 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 108 5.250 135.6 109 5.512 135.1 110 5.788 134.7 111 6.077 134.3 112 6.381 133.9 113 6.700 133.5 114 7.035 133.0 115 7.387 132.6 116 7.756 132.2 117 8.144 131.8 118 8.551 131.3 119 8.979 130.9 120 9.428 130.5 121 9.899 130.1 122 10.394 129.6 123 10.914 129.2 124 11.460 128.8 125 12.033 128.4 126 12.635 127.9 127 13.267 127.5 128 13.930 127.1 129 14.626 126.7 130 15.357 126.3 131 16.125 125.8 132 16.931 125.4 133 17.778 125.0 134 18.667 124.6 135 19.600 124.2 136 20.580 123.7 137 21.609 123.3 138 22.689 122.9 139 23.823 122.4 140 25.014 122.0 141 26.265 121.6 142 27.578 121.2 143 28.957 120.8 144 30.405 120.3 145 31.925 119.9 Page 26 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 146 33.521 119.5 147 35.197 119.1 148 36.957 118.7 149 38.805 118.2 150 40.745 117.8 151 42.782 117.4 152 44.921 116.9 153 47.167 116.5 154 49.525 116.1 155 52.001 115.7 156 54.601 115.3 157 57.331 114.8 158 60.198 114.4 159 63.208 114.0 160 66.368 113.6 161 69.686 113.1 162 73.170 112.7 163 76.828 112.3 164 80.669 111.9 165 84.702 111.4 166 88.937 111.0 167 93.384 110.6 168 98.053 110.2 169 102.956 109.8 170 108.104 109.3 171 113.509 108.9 172 119.184 108.5 173 125.143 108.1 174 131.400 107.6 175 137.970 107.2 176 144.868 106.8 177 150.000 106.5 Page 27 Rev. 00

ccs Compliance Certification Services Inc. L3to L2 test data: Test center CCS TEST REPORT Report No. : 90626003 Standard Test object MILSTD-461E/FCS101 20.1 Multimedia LCD Monitor WMRM920-PIP Customer Test engineer itech Company LLC Eric Recorded July 6, 2009 5:38:46 pm, with ICD 3.50.11 Test equipment Result file Description Result 1.) EM TEST AG, CWS 500E, RE9E0E9Q9A C:\EMTEST\ICD350\RESULT\11.prj Class : A Test passed Testfile Name Path curve 1 136dbuv ac 5%.nrm c:\emtest\icd350\standard\automotive\internat 9589\mil-std-461f\complate\cs101\curve 1 136dbuv ac 5%.nrm Modification date 2009/7/2 nwne 11:48:52 Climatic condition Temperature 23 Humidity 54 Pressure 1020 Test Values no. title F1 [khz] L1 F2 [khz] L2 F-step [khz] td[s] tp[s] Modulation [dbuv] [dbuv] 1. Curve #1 0.030 5.000 5.0 % 3.0 s 0.0 s CW 2. 5.000 150.000 106.5 5.0 % 3.0 s 0.0 s CW Page 28 Rev. 00

ccs Compliance Certification Services Inc. Diagrams Test summary no. Calibration file Tp. count Ev. count passed 1. Trafo2-1 Curve #1 0_03-150_0 khz, 5_0 %.CAL Coupling device: 1 176/177 1 no Model Sno Note Frequency range Coupling port description Trafo2-1 60VAC, 50ADC max 0.010.. 250.000 khz DC-Port Diagrams Page 29 Rev. 00

Compliance Certification Services Inc. Table of events : 1 no. Events Frequency Level Comment [khz] [dbuv] 1 Stop 150.000 106.5 Table of Test points : 176 no. Frequency Level [dbuv] [khz] 1 0.030 2 0.032 3 0.034 4 0.036 5 0.038 6 0.040 7 0.042 8 0.044 9 0.046 10 0.048 11 0.050 12 0.052 13 0.055 14 0.058 15 0.061 16 0.064 17 0.067 18 0.070 19 0.074 20 0.078 21 0.082 22 0.086 23 0.090 24 0.094 25 0.099 26 0.104 27 0.109 28 0.114 29 0.120 30 0.126 Page 30 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 31 0.132 32 0.139 33 0.146 34 0.153 35 0.161 36 0.169 37 0.177 38 0.186 39 0.195 40 0.205 41 0.215 42 0.226 43 0.237 44 0.249 45 0.261 46 0.274 47 0.288 48 0.302 49 0.317 50 0.333 51 0.350 52 0.368 53 0.386 54 0.405 55 0.425 56 0.446 57 0.468 58 0.491 59 0.516 60 0.542 61 0.569 62 0.597 63 0.627 64 0.658 65 0.691 66 0.726 67 0.762 68 0.800 Page 31 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 69 0.840 70 0.882 71 0.926 72 0.972 73 1.021 74 1.072 75 1.126 76 1.182 77 1.241 78 1.303 79 1.368 80 1.436 81 1.508 82 1.583 83 1.662 84 1.745 85 1.832 86 1.924 87 2.020 88 2.121 89 2.227 90 2.338 91 2.455 92 2.578 93 2.707 94 2.842 95 2.984 96 3.133 97 3.290 98 3.454 99 3.627 100 3.808 101 3.998 102 4.198 103 4.408 104 4.628 105 4.859 107 5.000 Page 32 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 108 5.250 135.6 109 5.512 135.1 110 5.788 134.7 111 6.077 134.3 112 6.381 133.9 113 6.700 133.5 114 7.035 133.0 115 7.387 132.6 116 7.756 132.2 117 8.144 131.8 118 8.551 131.3 119 8.979 130.9 120 9.428 130.5 121 9.899 130.1 122 10.394 129.6 123 10.914 129.2 124 11.460 128.8 125 12.033 128.4 126 12.635 127.9 127 13.267 127.5 128 13.930 127.1 129 14.626 126.7 130 15.357 126.3 131 16.125 125.8 132 16.931 125.4 133 17.778 125.0 134 18.667 124.6 135 19.600 124.2 136 20.580 123.7 137 21.609 123.3 138 22.689 122.9 139 23.823 122.4 140 25.014 122.0 141 26.265 121.6 142 27.578 121.2 143 28.957 120.8 144 30.405 120.3 145 31.925 119.9 Page 33 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 146 33.521 119.5 147 35.197 119.1 148 36.957 118.7 149 38.805 118.2 150 40.745 117.8 151 42.782 117.4 152 44.921 116.9 153 47.167 116.5 154 49.525 116.1 155 52.001 115.7 156 54.601 115.3 157 57.331 114.8 158 60.198 114.4 159 63.208 114.0 160 66.368 113.6 161 69.686 113.1 162 73.170 112.7 163 76.828 112.3 164 80.669 111.9 165 84.702 111.4 166 88.937 111.0 167 93.384 110.6 168 98.053 110.2 169 102.956 109.8 170 108.104 109.3 171 113.509 108.9 172 119.184 108.5 173 125.143 108.1 174 131.400 107.6 175 137.970 107.2 176 144.868 106.8 177 150.000 106.5 Page 34 Rev. 00

ffc I Compliance Certification Services Inc. \\^*\ 8. APPENDIX I PHOTOGRAPHS OF TEST SETUP CS101, Conducted susceptibility, power leads, 30 Hz to 150 khz Page 35 Rev. 00