HYDRAULIC GROUPS 1.1KW 1~ / 6.1CC. Article Code: 1GH008

Similar documents
Starting up hydraulic systems

PUMP SCPD 56/26 DIN BY-PASS

MANUAL FOR T HE INST ALLAT ION AND MAINT ENANCE OF MECHANICAL RET RACT ABLE BOLLARDS

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

OTTO HYDRAULICS GmbH & Co KG SYSTEME UND KOMPONENTEN FÜR ÖLHYDRAULISCHE ANTRIEBE UND STEUERUNGEN SIEMENSSTRASSE 12/ FRIEDRICHSHAFEN

ABSOLUTE EQUIPMENT PTY LTD

ABSOLUTE EQUIPMENT PTY LTD

1200W INVERTER GENERATOR

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

CIRCLE SEAL CONTROLS

Instruction Manual. Maximum Operating Pressure 510 bar

6 Litre Oil-Less Air Compressor

Operating Instructions

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Hydraulic Immediate Need Power Pack

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump

RESOL SBS 1000 * * Connection Operation

Operating Instructions & Parts Manual

Low Profile J Series Power Unit with Vane Pump

Angle seat valve with diaphragm actuator VZXA-...-M

Hydraulic power unit CE8L Technical data

Operating Instructions & Parts Manual

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Installation instruction

CIRCLE SEAL CONTROLS

Automatic concealed bollards 275 H600 and 275 H800 with pit

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Clamping and drive module

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Steps 3 through 9 in this procedure describe making and using a cooling system bleed tool.

Water pump Owner's Manual

1100W PORTABLE GENERATOR

Typical Installation Schematic

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

HL - MHL SPA SOCIETÀ ITALIANA TRASMISSIONI INDUSTRIALI. INSTALLATION, OPERATION and MAINTENANCE MANUAL

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

User Manual Rittal PMC UPS 6kVA

GD series Submersible Grinder Pump

IBT Series Square Drive Torque Wrenches

TRACTION BATTERY CHARGER SERVICE MANUAL

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

Angle seat valve with piston actuator VZXA-...-K

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Arm - TX series 40 family

HGV VARIABLE HYDRAULIC GENERATOR SYSTEMS

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

SUBMERSIBLE DIRTY WATER PUMP

Pulsar EXtreme CLA 1500C

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

NILFISK BA 500 Service Manual

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

USE AND INSTALLATION HANDBOOK

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

PNEUMATIC PUMP Series


Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Operating Instructions for Elevator Buffers type LP

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

AG-HA-2500N GASOLINE GENERATOR

Vane pumps, direct controlled Type PV7...A

1600 PSI ELECTRIC PRESSURE WASHER

Instruction for RBP250-3 and RBP300-3

PONTIAC Late Model (with 11 Bolt Water Pump)

KLW4000D Multi-Port Power Pack

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

MODVAR Low voltage reactive power compensation modules Installation manual

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

INSTALLATION & MAINTENANCE MODEL mm

Two Stage Rotary Vane Vacuum Pumps Operation and Maintenance Manual

SUBMERSIBLE PUMP HSE RANGE

Off-line filter units BNF. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2019

Routine Compressor Maintenance

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Mounting and Operating Instructions EB 5868/5869 EN

INSTRUCTIONS & MAINTENANCE SHEET PORTABLE BATTERY HYDRAULIC POWERPACK HAB1101

Air / Hydraulic Under Axle Jack

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

LCU DX Efficient cooling with no loss of space

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Trailer Brake System Bleeding Procedure:

SAGINAW P-SERIES PUMP INSTALLATION

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

F 167/94 07/ GM-

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

INSTRUCTIONS & MAINTENANCE SHEET PORTABLE BATTERY HYDRAULIC POWERPACK HAB1102


Transcription:

TECHNICAL MANUAL FOR HYDRAULIC GROUPS 1.1KW 1~ / 6.1CC WITH NEGATIVE SECURITY Article Code: 1GH008 THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT. THIS HYDRAULIC GROUP IS NOT DELIVERED READY FOR USE. THE GROUP COVER PLUG MUST BE REPLACED BY INLET FILTER (SEE INSTALLATION) ELECTRIC SHOCK HAZARD! Do not remove cover of electric box when power is on PRESSURIZATION HAZARD! Bleed circuit before intervention REPLACE COVER PLUG BY INLET FILTER NEVER TEST WHILE EMPTY! Equipment deterioration hazard Pictures are not contractual NT-1GH008(V1-EN) V1 06/2007

URBACO S.A. CONTENT 1. PRESENTATION OF THE HYDRAULIC GROUP... 3 1.1 General features... 3 1.2 Operation... 3 1.3 Conditions of use... 3 2. SPECIFICATIONS... 4 2.1 General Specifications... 8 2.2 Hydraulic Specifications... 8 2.3 Electrical Specifications... 8 2.4 Specifications of hydraulic oil... 10 3. OPERATION WITH A RETRACTABLE BOLLARD... 11 3.1 Basic Model... 11 3.2 Model with hand-operated pump (to set bollard upward again)... 14 4. COMMISSIONING... 18 4.1 Set-up... 18 4.2 Electrical connections... 18 4.3 Filling up with hydraulic oil... 18 4.4 Bleeding... 19 4.5 Check-list... 19 4.6 Operation of manual emergency device (bollard down)... 19 4.7 Operation of manual raise (bollard up)... 19 5. MAINTENANCE... 20 5.1 Inspection... 20 5.1.1 Interval between inspections... 20 5.1.2 Hydraulic oil... 20 5.1.3 Temperature... 20 5.1.4 External leaks... 20 5.2 - Maintenance... 21 5.2.1 Replacement of hydraulic oil... 21 5.2.2 Repairs... 21 5.2.3 Troubleshooting... 22-2 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc 1.1. General Features: 1. PRESENTATION OF HYDRAULIC GROUP Hydraulic groups are intended to supply pressurised oil to URBACO automatic retractable bollards with hydraulic cylinders. This group is so conceived that servicing and maintenance interventions are easy. From top to bottom, it consists of: 1 1-phased 230V electrical motor. 2 The flange which includes the hydraulic pump, the solenoid valve, the pressure inlet, the pressure regulator and the hand lever for manual descent. 3 The oil tank with tank filler neck and drain. The supply inlet is fitted with a hydraulic socket (not shown on drawing) to disconnect the oil flexible tube without any risk to let air inside circuit or spill oil (any manipulation on circuit should only be done with pressure off). 1.2. Operation: An electrical motor drives a pump. Oil is sucked inside tank and spills out under pressure by supply inlet. A solenoid valve will shunt fluid. Pressure is regulated and oil will be routed to tank as soon as pressure exceeds maximum pressure allowed. The transparent plastic tank makes it easy to check properly oil level and quality. This version with «negative security» is fitted with a hand lever for manual descent which enables operator to lower or descend the bollard when there is a power outage. A manual pump (available as an option) mounted on the group makes it possible to raise bollard back upward without power being supplied. 1.3. Conditions of use: This group is so constructed that it can ensure lengthy periods in duty or a rather intensive operation mode. Limits can be set with oil temperature (depending on ambient temperature). When temperatures are below 0 C/32 F, oil is less f luid and operation times may be longer (the bollard will be slower to retract). The appropriate adapted heating resistor will minimize this phenomenon. Oil temperature must be between 0 C and 70 C (32 F and 158 F) for optimised functioning. Extreme operation conditions may cause the system to overheat and resultantly, the pump will deteriorate and hydraulic fluids evaporate. High temperatures may cause severe burns. Length of operation duty must be defined depending on power called upon, conditions of use as well as environment, so that the temperature of oil inside system will not exceed 70 C / 158 F. - 3 -

URBACO S.A. 2. SPECIFICATIONS 11 12 1 7 9 2 3 8 10 5 6 4 Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 4 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc N Designation Specifications 1 Single-phased electrical motor with capacitors 1.1kW - 220V 1 Phase 1450 rev/min - B14 2 Connection box Connection terminal box 3 Adapter block TP3 B 4 Tank Plastic, 4 litres / 1,06 gallons 5 Filling cap with filter 6 Drain plug 7 Solenoid valve NF 2/2 24VAC 8 Manual control valve with hand lever 9 Pressure regulator 10 Pressure bleed shutter 11 Supply inlet (shown without coupler) 12 Fixings 2M10, 82mm between the axles - 5 -

URBACO S.A. Hydraulic group showing manual rise pump option: 11 12 1 13 2 7 3 9 8 10 5 13 4 6 Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 6 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc N Designation Specifications 1 Single-phased electrical motor with capacitors 1.1kW - 220V 1 Phase 1450 rev/min - B14 2 Connection box Connection terminal box 3 Adapter block TP3 B 4 Tank Plastic, 4 litres / 1,06 gallons 5 Filling cap with filter 6 Drain plug 7 Solenoid valve NF 2/2 24VAC 8 Manual control valve with hand lever 9 Pressure regulator 10 Pressure bleed shutter 11 Supply inlet (shown without coupler) 12 Fixings 2M10, 82mm between the axles 13 Manual rise pump, option - 7 -

URBACO S.A. 2.1. General specifications: Designation: Electro-hydraulic group. Consisting of: gear pump driven by external electric motor. Plastic tank. Fixings: 2 holes on the unit flange for size M10 bolts. Weight (empty): 20 kg (value given without hydraulic fluid or drivers). Weight filled up: 24 kg To be set up vertically, tank at the bottom. Ventilation filter: integrated with filling cap. Protection index: IP44 Dimensions (L x w x H): 291 x 240 x 543 mm 2.2. Hydraulic specifications: Maximum pressure tolerated: 60 bars Flow: Q= 8.85 l/min. Hydraulic fluid BioHydran TMP46 according to international specifications VDM24568 ISO15380 (see 3.6). Hydraulic fluid temperature span: 0 C min / +80 C max. Optimal viscosity span: 10 to 380mm²/s Oil tank volume: V F = 4 litres (do not exceed maximum level) Volume of oil usable: V E = 3 litres (do not exceed minimal level either) Pressure relief: Adjustable from 0 to 60 bars Adjustable by turning bolt one way or the other to increase or decrease pressure. 2.3. Electrical specifications: Consists of: 1-phase motor with ignition capacitor. Cooling with ambient air. Nominal tension: 220/240V 1-phase Frequency (Hz) Tension U(V) Intensity In (A) Power (kw) Revolution Speed n(rev/min) 50 230 8 1,1 1450 Capacitor: 36µF / 450V Additional capacitor: 50µF / 450V (depending on model) Connection Type: Terminal plate in motor connection rack Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 8 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc Connection terminal plate of motor: Solenoid Valve: - Voltage 24VAC (by rectifier) - Operatability: non-stop - 9 -

URBACO S.A. 2.4. Specifications of oil used: High quality synthetic biodegradable hydraulic fluid TOTAL BIOHYDRAN TMP46. In compliance with VDMA24568 and ISO15380 (HEES) international specifications. Compatibility with elastomer elements used in hydraulic circuits STANDARD SPECS METHOD UNITS BIOHYDRAN TMP46 Aspect - Visual Liquid limpid Voluminal mass at 15 C ISO 3675 kg/m3 920 Viscosity at 40 C ISO 3104 mm²/s 46 Viscosity at 100 C ISO 3104 mm²/s 9,5 Viscosity index ISO 2909-183 Cleveland open-cup flash point ISO 2592 C // F +2 85 // +545 Pour point ISO 3016 C // F -39 // -38.2 Biodegradability Test Ratio after 21 days CEC L-33-A-93 % >90 FZG A/8, 3/90 DIN 51354 Fail stage 11 Utilisation temperature range C // F -20 to +90 // -4 to +194 Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 10 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc 3.1. Basic Model: 3. OPERATION WITH A RETRACTABLE BOLLARD - 11 -

URBACO S.A. Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 12 -

Technical Manual for Hydraulic Groups 1.1kW 60 bars. - 13 -

URBACO S.A. 3.2. Model with hand pump (to set bollard upward again): Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 14 -

Technical Manual for Hydraulic Groups 1.1kW 60 bars. - 15 -

URBACO S.A. Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 16 -

Technical Manual for Hydraulic Groups 1.1kW 60 bars. - 17 -

URBACO S.A. 4. COMMSSIONING 4.1. Mounting: KEEP YOUR ENVIRONMENT CLEAN! Fix hydraulic group on its support with 2 x M10 screws. It is imperative that the appropriate hydraulic tubes be used, fitted out with quick-connect couplings. Note: URBACO s flexible hydraulic tubes are delivered filled up and bled, ready for use. Place them so that they will not be exposed to any strain. 4.2. Electrical connections: MOTOR: All electrical connecting tasks should be performed by qualified personnel only. Starting up the hydraulic centre is forbidden as long as the whole machinery set is not certified in compliance with standards. Only proceed with maintenance or controls on motor if power is off. Connect motor according to indications given in 2.3 To guarantee IP44 protection index, the motor cable must run through gland. Protection by differential circuit-breaker 16A curve D and fuse 10A am (for 1 group). CAUTION! DO NOT PROCEED WITH ANY TEST WHEN TANK IS EMPTY (WITHOUT OIL) ONLY TURN 1-PHASE MOTOR ON IF CIRCUIT IS OFF PRESSURE. SOLENOID VALVE: Supply power to the solenoid valve. Connection is done via connector with dual cable provided. Carefully check that tension type is suitable. A rectifier is also built in solenoid valve for alternate tension functioning (See 2.3). 4.3. Filling up with hydraulic oil: FILL UP THE HYDRAULIC GROUP CLEANLY AND CAREFULLY. Only use hydraulic fluid with specifications identical to 2.4. Fill up generator using thin strainer all the way to the maximum level gauge mark. Note: Hydraulic groups supplied by URBACO are filled up with oil in our factory. Checking up level on receipt should suffice. During transportation, a water- /air-tight cap replaces air filter cap to prevent spilling. This transport cap must be removed and replaced by cap supplied. - 18 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc 4.4. Bleeding: Note: This is done in our factory for new equipment. See 5.2.1 if bleeding must be done. 4.5. Checklist: Check there is no external leak on any component and on couplers. During control, pay attention to any suspicious noise. Do not exceed maximum authorised volume of oil usable (see 2.2) 4.6. Operation of manual emergency device (bollard down): This hydraulic group comprises a solenoid valve (NF=normally closed) which makes it possible to maintain the bollard upward in case of a power cut. A descent hand lever makes it possible in this case to lower the bollard manually. To do this, pull on lever until the bollard reaches its retracted position 4.7. Operation of manual raise (bollard up): As an option, a manual raise pump is integrated to the group to make it possible to raise the bollard with power being supplied. To do so, actuate lever for a minute or so, to raise bollard.. - 19 -

URBACO S.A. 5. MAINTENANCE Before proceeding with any intervention of maintenance, servicing or repair on any component of the hydraulic group, it is of paramount importance to check that the whole system is turned off. The life span of the hydraulic group depends on maintenance operations. The specifications of the oil to be used as well as its cleanness are essential elements which will have a leading part in the working performances of the hydraulic group and operational qualities of the system. It is therefore strongly advised to use products recommended by URBACO. Components, be they hydraulic, electrical, mechanical or of any other kind, have been rigorously selected and tested to provide and guarantee maximum quality. 5.1. Inspection : 5.1.1 Interval between inspections: We advise to proceed with an inspection: At commissioning 1 week after commissioning 4 weeks after commissioning Once every three months afterwards. 5.1.2 Hydraulic oil: Check aspect so as detect presence of air bubbles or water in the circuit (foam on surface) which would be highly detrimental to the components of the group. Check oil level in tank level, add more if necessary. CAUTION! Only add hydraulic oil of the same brand. Do not mix brands or types. In case of premature modifications (darker colour, smell, milky texture, etc.) proceed with replacement of oil as indicated in 5.2.1. If air bubbles are noticed in hydraulic fluid, bleed the whole system as indicated in 5.2.1. 5.1.3 Temperature: Temperature of hydraulic fluid must not exceed +80 C. If temperature is abnormally high, it may be due to: Extensive use Motor supply too high or too low A leak inside or outside generator or hydraulic circuit. 5.1.4 External leaks: Check all elements and all couplers. - 20 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc 5.2. Maintenance: CLEAN WORK IS GOOD WORK HELP PROTECT OUR ENVIRONMENT AND BE CAREFUL DURING MAINTENANCE 5.2.1 Replacement of hydraulic oil: Hydraulic fluid must b replace at least every 2 years. Depending on the environment (dusty or humid) in which the hydraulic group is set up as well as conditions of use, oil will be controlled and replaced on a more regular basis. As soon as oil in tank looks darker, dirty, and foamy or if water seems to cover oil surface, it must be replaced with no further delay. The pump may be deteriorated. Respect prescriptions as well as legislation in terms of polluted fluids. Bleeding the group: All bollards must be down (circuit off pressure and system off power) Completely drain oil from tank by removing cap N 6 (bottom part of tank) Rinse tank so as to eliminate all deposits and check pump visually. Replace drain cap N 6 (replace seal if necessary) If a connector must be replaced, use adequate product applied at threading level. Fill up tank with oil as recommended. Bleeding the hydraulic circuit: This must be done if oil in tank appears very filthy or deteriorated. To be done by qualified personnel only. 7 Remove bollard cover and lift bollard head out. 8 Open drain valve on the cylinder or on a connection located higher 9 Start pump until oil spills out clean and free of air bubbles. 10 Make sure the oil level in tank remains sufficient. 11 Turn motor off and close valve or connection. 12 Check oil level and if necessary, add some more (circuit off pressure, bollards down). 13 Carefully clean oil overflows if necessary Raise bollard and proceed with tests for good working order. Never try to stop an oil leak by unduly tightening connectors. It is rather recommended to change them if they are defective or worn. 5.2.2 Repairs: Prior to any intervention on installation, make sure than power is off according to security rules, that all motive parts are disabled, and that installation if off pressure. In case some components need to be replaced, only resort to original parts. - 21 -

URBACO S.A. 5.2.3 Trouble-shooter: The motor runs but the bollard won t rise: The motor is not rotating in the right way; check cabling of connection plate. The solenoid valve is not driven: check if power is properly supplied, or if solenoid is not damaged. A hydraulic flexible is undone: put it back on Pressure relief is not properly adjusted: adjust with manometer. Hydraulic circuit is leaking: repair leak. The bollard rises but very slowly: Pressure relief is quasi maximum: proceed and adjust with manometer. The bollard won t go down: The solenoid is not driven: check if power is properly supplied, or if solenoid is not damaged Power is off: actuate descent hand lever (in negative security situation) A foreign body prevents the bollard from going down; clean the bollard components. The descent command is without effect: control automated parts. Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 22 -

Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 23 -

URBACO S.A. Type: 1GH008 First released: 2007 URBACO S.A. - Z.A. du Couquiou 84320 ENTRAIGUES - FRANCE International Sales: +33 490 480 800 - Fax: +33 490 480 088 E-mail: urbaco@urbaco.fr // www.urbaco.fr Technical Manual for Hydraulic Groups 1.1kW 1~ / 6.1cc - 24 -