Industrial, Commercial and Institutional Boilers Maximum Achievable Control Technology ( IB-MACT) 5/28/15 Katie Cunningham

Similar documents
Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

Part 70 Operating Permit Amendment

Major/Area Source. Speaker: Eric Swisher. 23rd Virginia Environmental Symposium April 11, Your environmental compliance is clearly our business.

Tune-up Information. Owners and operators of all biomass-fired and oil-fired area source boilers.

RICE NESHAP RECORD KEEPING Stationary Engines

DEP7007CC Compliance Certification

6/1/2011. NSPS and MACT Standards for Combustion Sources at Utility Authorities What happens when a permit has both federal and state regulations?

Area Source NESHAPS and Air Permits

State of New Jersey. Department of Environmental Protection Air Quality Permitting. General Permit (GP-017A) For

SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT

AIR QUALITY PERMIT. Kennesaw State University - Marietta Campus

Draft Air Individual Permit Part 70 Reissuance

TABLE B: SUBMITTALS. Fiscal Services 520 Lafayette Road North, St. Paul, Minnesota

State of New Jersey Department of Environmental Protection Division of Air Quality. General Operating Permit (GOP-007) Boiler or Heater

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

Graphic. Air Compliance Issues and Solutions. Sunita Dhar, PhD Senior Scientist First Environment 91 Fulton Street, Boonton

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

PART 70 OPERATING PERMIT FACT SHEET U.S. ARMY GARRISON AT FORT DETRICK 201 BEASLEY DRIVE, FREDERICK, MD PART 70 PERMIT NO.

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

Streamlining Multiple Applicable Requirements

MARAMA 2015 SCIENCE MEETING JULY 29-30, 2015 RICHMOND, VIRGINIA

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).

US oil production hits 15-year high: DEC 04, 2012

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015

NARRATIVE. Dika Kuoh Alaa-Eldin A. Afifi DATE: December 14, 2015

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

SECTION.1400 NITROGEN OXIDES

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706

9/17/2013 OVERVIEW WHAT RICE UNITS ARE IMPACTED? WHAT IS A RICE UNIT? EXAMPLES OF RICE UNITS WHY IS THE EPA REGULATING RICE?

Electrical Power Generator Use and Procurement Guidance

AIR QUALITY PERMIT. 7 Foundation Drive Savannah, Georgia (Chatham County)

RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008)

RICE NESHAP Requirements for Stationary Engines at Area Sources of Hazardous Air Pollutants 1

Annual Combustion Adjustments

Fuel Oil Conversions. Association of Energy Engineers (AEE) September 20, 2011

Permit Holder. Permitted Equipment

WORKSHOP REPORT. No, the RICE NESHAP applies only to stationary engines as defined in 40 CFR

RICE NESHAP Frequently Asked Questions (FAQ)

New Federal Regulations for Internal Combustion Engines. Doug Parce

Draft Air Individual Permit Part 70 Reissuance

RULE NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016)

Applicable Requirements - NSPS Subpart JJJJ

AIR PERMITTING REQUIREMENTS FOR ON-SITE STATIONARY POWER GENERATING ENGINES

A high level overview of the federal NSPS and NESHAP rules as they apply to owner/operators of internal combustion engines

ARTICLE AIR POLLUTION CONTROL REGULATIONS AND PROCEDURES

RICE MACT / NSPS Update: How to Make Sense of this Difficult Issue

2017Compliance Table with methods.xlsx

AIR EMISSION PERMIT NO IS ISSUED TO NORTHERN STATES POWER COMPANY

Reproduction of Permit Terms and Conditions

General Permit (005B) for Emergency Generator(s) burning Gaseous Fuels

Regulatory and Permitting Requirements of Stationary Generators In Delaware

Facility Name: Packaging Corporation of America City: Clyattville County: Lowndes County AIRS #: Application #: 22133

For NOx RACT 25+ MMBTU

VALMET IBMACT & Utility MATS. Boiler Tune-ups

PERMIT TO INSTALL. Table of Contents

RULE 412 STATIONARY INTERNAL COMBUSTION ENGINES LOCATED AT MAJOR STATIONARY SOURCES OF NO X Adopted INDEX

Registration, Recordkeeping, and Reporting Requirements

State of New Jersey. General Permit (GP-009A)

COMMONWEALTH of VIRGINIA

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

An Overview of NSPS Subpart QQQ VOC Emissions from Petroleum Refinery Wastewater Systems

Federal Engine Regulations NSPS JJJJ/NESHAP ZZZZ

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS

This rule shall apply to any stationary source which is a major source of regulated air pollutants or of hazardous air pollutants.

Toyota Motor North America, Inc. Grant of Petition for Temporary Exemption from an Electrical Safety Requirement of FMVSS No. 305

~ SWCAA. ~awfxm~ Paul T. Mairose Chief Engineer

PA RACT 2. Reasonably Available Control Technology. Presented by Suzanne Dibert

Permit Holder. Permitted Equipment

REGISTRATION OF SPECIFIED EQUIPMENT (Adopted 5/21/97; Rev. Effective 11/15/00) (1) This rule applies to the following emission units:

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95)

Facility Name: BASF Corporation Attapulgus Operations City: Attapulgus County: Decatur AIRS #: Application #: 22788

APPENDIX F PERFORMANCE COMPENSATION AND GUARANTEES

New Source Performance Standards for Stationary Spark Ignited Internal Combustion Engines

OR Hillsboro SD 1J 3083 NE 49th Pl Hillsboro OR Division 22 Assurances Form. Due February 15, 2019

North Carolina Department of Environment and Natural Resources Division of Air Quality

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. May 1, 2015 PERMIT TO INSTALL 4-13B. ISSUED TO Zoetis LLC

(2) ANNUAL HEAT INPUT means the actual amount of heat released by fuels burned in a unit during a calendar year.

RICE NESHAP ZZZZ (>500 hp Non-Emergency CI Engines) Altorfer Meeting June 15, 2010

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

August CFR Part 63 Subpart ZZZZ review

Creating A Greener Energy Future For the Commonwealth. Massachusetts RPS Solar Carve-Out: Overview & Program Basics.

Prepared for: BP-Husky Refining LLC 4001 Cedar Point Road Oregon, Ohio Prepared by:

COMMONWEALTH OF PENNSYLVANIA Department of Environmental Protection June 10, / Fax: 814/

South District. Reciprocating Internal Combustion Engines EPA S RICE NESHAP and NSPS. Carter B. Endsley, P.E. Air Resource Permitting

SCHEDULE 6 RESIDENTIAL SERVICE ON-SITE GENERATION

Internal Combustion Engines Air Updates 2010

Federal Railroad Administration, DOT CFR section Description Guideline PART 179

Umatilla Electric Cooperative Net Metering Rules

SCAQMD Rule 1470 Impact on Diesel Generator Installations

STATEMENT OF BASIS Boise Cascade Wood Products, LLC Thorsby Engineered Wood Products Thorsby, Chilton County, Alabama Facility/Permit No.

FINAL UNDERGROUND STORAGE TANK RULE CHANGES. Heather Peters UST Compliance and Technology Unit

PERMIT TO INSTALL. Table of Contents

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Case Study. Modernising gas fired power plant boiler damper drives and damper bearings

ESF on Fire Protection Proposed ESF on Fire Protection Engine attachment points applicable to Piston Engines EASA

Michigan Renewable Energy Case Study

How to Comply with EPA Regulations for Stationary Reciprocating Internal Combustion Engines ( RICE ) Roy Crystal, EPA Region 1 (New England)

PERMIT APPLICATION REVIEW SUMMARY

Ì229556GÎ CHAMBER ACTION Senate. House...

Transcription:

Industrial, Commercial and Institutional Boilers Maximum Achievable Control Technology ( IB-MACT) 5/28/15 Katie Cunningham

Consumers Energy and Michigan Provides electric and natural gas service to 6.5 million of Michigan s 10 million residents throughout the Lower Peninsula 2.9 million customer accounts Fifth-largest combination utility in U.S. 2012 marked 125 years of service to Michigan 1

Major Investments in Michigan 2 Consumers Energy is one of the largest investors in Michigan s economy

Consumers Energy Electric Generation Hydro, Wind, Gas, Coal 5 Coal fired Sites JH Campbell DE Karn JC Weadock JR Whiting BC Cobb 1 Gas Site Zeeland Generation Station Gas Services Transmission and Storage 12 Compressor Stations, Storage Fields Distribution

Consumers Energy IB MACT Sources 5 oil fired units 37 gas units 1 Limited Use by Permit 3 Units that we will be requesting extension for as they will be permanently shutdown by July 2016 - One gas/oil fired 23mmBtu/hr o - One oil fired - 0.6 mmbtu/hr o - One gas fired 32mmBtu/hr No Units with Emission Limits

Overview of Reporting Requirements Major Sources New Units Initial applicability notification within 15 days of start-up Notice of Compliance Status (NOCS) within 180 days of start-up No NOCS due if only reporting tune-up compliance Semi-annual compliance reports Compliance reports starting semi-annually, at least 180 days past compliance date, on January 31 or July 31. Existing Units Initial applicability in May 2013 NOCs by January 31, 2016 Semi-annual compliance reports starting July 31, 2016 For tune-up/ea units only, report by January 31, the year after the tuneup (every 1, 2 or 5 years)

IB MACT If have emission limits, NOCS Must include: (63.7545) Facility ID, Unit ID and subcategory, controls used for IB MACT compliance, fuels burned Summary of all performance tests, fuels analysis and calculations demonstrating compliance with limit Max CO levels during performance test if no CO CEMS Identify compliance method testing, CEMS, or fuels analysis or emissions averaging, energy conservation

IB MACT If have emission limits, NOCS Must include: (63.7545) cont Signed certification that you have met all emission limits/wp Standards Deviations description, duration, and corrective action The following statements, signed by a responsible official: This facility complies with the required initial tune-up according to. This unit has had an energy assessment performed according to. No secondary materials that are solid wastes were combusted in any affected unit (except for gas units)

IB MACT No NOCs for new sources with only tune-up requirement submit compliance report on Jan 31 following tune-up. If no emission limits, NOCS Must include: (63.7545) Facility ID, Unit ID and subcategory, controls used for IB MACT compliance, fuels burned The following statements, signed by a responsible official: This facility complies with the required initial tune-up according to. This unit has had an energy assessment performed according to. No secondary materials that are solid wastes were combusted in any affected unit (except for gas units) Reconsideration Proposal has different language for the tune-up statement

Other Notification If you switch fuels or make physical change to boiler that affects the subcategory, provide notice to Administrator w/in 30 days Date of change, date of notice Current applicable subcategory The date upon which the change occurred

Compliance Reports (63.7550) Submit reports in CEDRI Due semi-annual if you have emission limits January 31 and July 31 Can request from Administrator to move dates to ROP semiannual reporting (March, Sept) No emission limits, only tune-up Due Jan 31 following most recent tune-up (at frequency of 1,2, or 5 years) Reports must contain read paragraph c! If subject to tune-up: Company/facility info Process unit info Date report and of reporting period (ie January December 2016)

Compliance Reports (63.7550) Reports must contain (cont ) The total operating time during the reporting period Reconsideration requires this only for limited use units Date of most recent tune-up, including delayed burner inspection Delay of burner inspection allowed by Paragraph 63.7540(a)(10)(i): As applicable, inspect the burner, and clean or replace any components of the burner as necessary (you may delay the burner inspection until the next scheduled unit shutdown). Units that produce electricity for sale may delay the burner inspection until the first outage, not to exceed 36 months from the previous inspection. At units where entry into a piece of process equipment or into a storage vessel is required to complete the tune-up inspections, inspections are required only during planned entries into the storage vessel or process equipment; Signed statement by responsible official

Compliance Reports (63.7550) Other Submissions 60 days after test event Submit results of performance test in CEDRI with ERT upload Submit results of CEMS performance evaluation test in CEDRI

Electronic Reporting CDX EPA s Central Data Exchange Facilities may already be set up in CDX for GHG Reporting or other NSPS reporting Password expires every 90 days CEDRI Compliance and Emissions Data Reporting Interface Set up company, facilities and roles If approver already set up in CDX for a facility, ensure that you pick the same Company and Facility code with setting up the CEDRI account. Role sponsorship for delegated certifier can take some time to do (a week or two), get this done early, or Get prior written authorization from RO to be a delegated certifier and register as such Save answers to your security questions somewhere MDEQ Submit hard copies of everything to District

Other Tid-bits / Recommendations Inventory of all applicable equipment Date of install Date of Tune-up Date of EA When NOCs is due When Compliance Report due If many plants/many units, create a report form for the NOCs and Compliance Report for uniformity Set up the tune-ups in Maintenance System at required frequencies, attach a tune-up checklist and report form Indirect fire boiler with glycol/water mix, exempt if used for comfort/space heating under Process Heater Definition

Other Tid-bits / Recommendations Have you checked limited use? Saves on tune-up frequency and energy assessment. Get PTI application in asap Need an extension? Allowed for in 63.6 if meet criteria. Contact MDEQ Records, 63.7555 (d)(3), Limited Use: Monthly fuel use is acceptable per Jim Eddinger of EPA (courtesy of DTE) Reconsideration Proposal: Clarifies recordkeeping for start-up/shutdown in 63.7555 (i) and (j), adds them under (d) 11 and 12.

Reporting Example www.epa.gov/cdx Questions?