An Overview of NSPS Subpart QQQ VOC Emissions from Petroleum Refinery Wastewater Systems
|
|
- Percival Ryan
- 5 years ago
- Views:
Transcription
1 An VOC Emissions from Petroleum Refinery Wastewater Systems Michelle Yakubisin Senior Engineer, ERM Copyright 2018 by ERM Worldwide Group Limited and/or its affiliates ( ERM ). All Rights Reserved. No part of this work may be reproduced or transmitted in any form or by any means, without prior written permission of ERM. 4/3/18 Page 1
2 Objectives Importance of 40 CFR Part 60 Subpart QQQ (NSPS QQQ) Overview of NSPS QQQ Applicability Definitions Control standards Recordkeeping and reporting Q&A 4/3/18 Page 2
3 Why is NSPS QQQ Important? Confusion on the basics Lack of precedent and consistency Sometimes overlooked during the MOC and project planning process More focus on BWON (so QQQ may be forgotten) Not heavily enforced, but some cases have been significant United States v. Ashland Inc Plea Agreement Required an upgrade of all refinery process sewers, junction boxes, and drains to NSPS QQQ standards Required payment of $9+ million in fines and restitution 4/3/18 Page 3
4 Applicability What is subject to NSPS QQQ? Applies to affected facilities located in refineries for which construction, reconstruction, or modification commenced after May 4, 1987: Individual drain system (IDS) Oil-water separator (OWS) Aggregate facility What is not subject to NSPS QQQ? Stormwater sewer system Ancillary equipment that is physically separate from the wastewater system and does not come into contact with or store oily wastewater Non-contact cooling water systems Italics indicates definition in or /3/18 Page 4
5 Individual Drain System (IDS) IDS means all process drains connected to the first common downstream junction box; includes all such drains and common junction box, together with their associated sewer lines and other junction boxes, down to the receiving oil-water separator 4/3/18 Page 5
6 Oil-Water Separator (OWS) OWS means wastewater treatment equipment used to separate oil from water consisting of a separation tank, which also includes the forebay and other separator basins, skimmers, weirs, grit chambers, and sludge hoppers Also includes slop oil facilities, including tanks Also includes storage vessels and auxiliary equipment located between IDS and OWS Does not include storage vessels or auxiliary equipment that does not come in contact with or store oily wastewater 4/3/18 Page 6
7 Example IDS and OWS to 4/3/18 Page 7
8 Aggregate Facility Aggregate facility means an IDS together with ancillary downstream sewer lines and OWS, down to and including the secondary OWS, as applicable 4/3/18 Page 8
9 Example Aggregate Facility 4/3/18 Page 9
10 Construction Construction means fabrication, erection, or installation of an affected facility In NSPS terms, entire affected facility needs to be added to meet construction definition 4/3/18 Page 10
11 Reconstruction Reconstruction means replacement of components of an existing facility such that: Fixed capital cost of new components exceeds 50% of fixed capital cost to construct a comparable new facility It is technologically and economically feasible to meet NSPS Standards As such, reconstruction is triggered under QQQ when there is a major change to an affected facility, regardless of whether VOC emissions increase 4/3/18 Page 11
12 Modification Modification means any physical or operational change to an existing facility which results in an increase in the emission rate To modify an affected facility under NSPS QQQ, a project must change the oily water sewer system (not change a source of wastewater discharging into the sewers) and must result in increased VOC emissions within the affected facility. Other exclusions may apply Changes excluded from modification are in 60.14(e): A change to the oily water sewer or OWS is excluded if:» Results in no increase of VOC (kg/hr) in affected facility; OR» Costs < 7% of the cost basis of the affected facility prior to the change 4/3/18 Page 12
13 Control Requirements Drains Water seal controls (seal pot, p-leg trap, or other type of trap filled with water that is capable of creating a water barrier between the sewer and atmosphere)* Junction boxes (e.g., manhole) Cover with tight seal around the edge Bolts and gaskets conservative; metal to metal is okay May have open vent pipe; pipe 90 cm (3 ft) in length and 10.2 cm Tight seal on junction box (4 in) in diameter Sewer lines Cannot be open to atmosphere Covered or enclosed; no visual gaps or cracks P-trap water seal *Can install completely closed drain system as an alternative to water seals 4/3/18 Page 13
14 Inspection Requirements Equipment Frequency* Inspection Check Drain active service Monthly Indications of low water levels or other conditions that could reduce the effectiveness of water seal Drain out of service Weekly controls Drain out of service w/ tightly sealed cap or plug Semiannually Cap or plug is in place and is properly installed Junction box Semiannually Cover is in place and has tight seal around edge Aboveground sewer line Semiannually Indications of cracks, gaps, or other problems that could result in VOC emissions *All equipment types require an initial inspection followed by inspections at the noted frequency 4/3/18 Page 14
15 Repair Requirements Equipment Drain active service Drain out of service Drain out of service w/ tightly sealed cap or plug Junction box Aboveground sewer line Repair Attempt Timing* Add water or make first effort at repair as soon as practicable, but no later than 24 hours after detection Make first effort at repair as soon as practicable, but no later than 15 calendar days after broken seal or gap is identified Make first effort at repair as soon as practicable, but no later than 15 calendar days after crack or gap is identified *Delay of repair is allowed if repair is technically impossible without a complete or partial refinery or process unit shutdown; repair must occur before end of next refinery or process unit shutdown 4/3/18 Page 15
16 OWS Requirements OWS tank, slop oil tank, storage vessel, or other auxiliary equipment must have a fixed roof vented to a control device, except no control device is required for limited small separators A floating roof is acceptable alternative standard NSPS K, Ka, and Kb are acceptable equivalent standards for storage vessels Roof doors and openings need to be gasketed and latched Inspect seals, access doors, and other openings semiannually Make first effort at repair as soon as practicable, but no later than 15 calendar days after broken seal/gasket or other problem is identified 4/3/18 Page 16
17 Closed Vent Systems and Control Devices Closed vent systems and control devices must be: Operated at all times when emissions may be vented to them Designed and operated with no detectable emissions (i.e., VOC reading < 500 ppm during initial and semiannual inspections) Vent stream must be equipped with a flow indicator Gauging and sampling devices must be gas-tight Make first effort at repair as soon as practicable, but no later than 30 calendar days after detection 4/3/18 Page 17
18 Recordkeeping Location and date of corrective actions to conform with standards Delay of repair information for components that cannot undergo repair: Expected date of repair Reason for delay Signature of person who decided repair could not be conducted without shutdown Date of successful repair or corrective action 4/3/18 Page 18
19 Recordkeeping cont. Copy of design specs for all equipment used to comply with NSPS QQQ Location of capped or plugged drains Drawings demonstrating that stormwater sewer (or other non-voc sewer) is segregated from oily water sewer Plans and drawings demonstrating that non-contact cooling water does not contact hydrocarbons or oily wastewater and is not circulated through a cooling tower Operating records and performance efficiency demonstration for closed vent systems and control devices, if used to comply with QQQ 4/3/18 Page 19
20 Reporting Notification required for: Construction, reconstruction, or modification of an affected facility Actual date of initial startup Initial certification of compliance Semiannual report should include: All drain inspections not conforming to standard Gaps, cracks, or other problems in junction box covers Repairs/corrective action(s) taken and dates of corrective actions Other information, as applicable 4/3/18 Page 20
21 Questions? Michelle Yakubisin Senior Engineer, ERM Walnut Creek, CA 4/3/18 Page 21
CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES
CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES FOR ALL FOUR OZONE NONATTAINMENT AREAS:! Delay of repair beyond the next process unit shutdown is allowed if the component is isolated from
More informationSummaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC
2011 Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC Ohio EPA, Division of Air Pollution Control 1/1/2011 Page 2
More informationGENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS
COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF AIR QUALITY GENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS GENERAL
More informationWell Pad Operations. Pennsylvania s GP-5A for Sources at Unconventional Natural Gas Well Sites
Comparison of Pennsylvania Requirements, EPA Rules, and CSSD Requirements for Methane & VOC Emission Reduction for the Oil & Gas Industry Effective August 8, 2018 Air Quality Permit Category No 38 Exemption
More informationRICE NESHAP ZZZZ (>500 hp Non-Emergency CI Engines) Altorfer Meeting June 15, 2010
RICE NESHAP ZZZZ (>500 hp Non-Emergency CI Engines) Altorfer Meeting June 15, 2010 Discussion Topics Background Important Terms Applicability Compliance Deadlines Emission/Operating Limits Performance/Compliance
More informationAIR QUALITY PERMIT. 7 Foundation Drive Savannah, Georgia (Chatham County)
AIR QUALITY PERMIT Permit No. Effective Date April 11, 2016 In accordance with the provisions of the Georgia Air Quality Act, O.C.G.A. Section 12-9-1, et seq and the Rules, Chapter 391-3-1, adopted pursuant
More informationTune-up Information. Owners and operators of all biomass-fired and oil-fired area source boilers.
Tune-up Information National Emission Standards for Hazardous Air Pollutants for Area Sources: Industrial, Commercial, and Institutional Boilers 40 CFR Part 63 Subpart JJJJJJ Who must conduct a tune-up
More informationSan Joaquin Valley Unified Air Pollution Control District Permit Services Division
San Joaquin Valley Unified Air Pollution Control District Permit Services Division Organic Liquid Storage Tanks Cleaning Requirements Approved By: Date: 2/20/08 David Warner Director of Permit
More informationTitle V. Model General Permit Template. SERIES 18 Tanks. Template # SJV-TK
Title V Model General Permit Template SERIES 18 Tanks Template # SJV-TK TK-18 18-1 Fixed roof tank Tank used at drilling and production facility prior to custody transfer Except for complying with sections
More information1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the
15A NCAC 02D.1206 HOSPITAL, MEDICAL, AND INFECTIOUS WASTE INCINERATORS (a) Applicability. This Rule applies to any hospital, medical, and infectious waste incinerator (HMIWI), except: (1) any HMIWI required
More informationWater Solutions. API Oil/Water Separators - A Total Approach. siemens.com/energy/water-solutions
Water Solutions API Oil/Water Separators - A Total Approach siemens.com/energy/water-solutions Backed by over 70 years of experience providing new, innovative and cost-effective wastewater treatment solutions,
More informationApplicable Requirements - NSPS Subpart JJJJ
Facility Name: CO Station 3 Combustion Type: 4SRB Facility HAP Status: Area Fuel Type: Natural gas RICE Owner: RICE Operator: S2C Gathering Co Acme Operating Inc. Use Type: Max. Runtime: Non-emergency
More informationRULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX
RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:
More informationFederal Engine Regulations NSPS JJJJ/NESHAP ZZZZ
Federal Engine Regulations NSPS JJJJ/NESHAP ZZZZ Presented to OIPA: May 11-12 2011 A World of Energy Solutions NSPS JJJJ Slide 2 NSPS New Source Performance Standards History Regulates criteria pollutants
More informationNYSDEC PBS REGULATIONS Heating Oil Tanks
1 NYSDEC PBS REGULATIONS Heating Oil Tanks Central Office/Region 2 Division of Environmental Remediation Bulk Storage Compliance Program NISTM 2017 New York Storage Tank Conference Saint Francis College,
More informationIndustrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary
Industrial, Commercial and Institutional Boilers at Area Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary Federal Regulation NESHAP, 40 CFR 63, Subpart JJJJJJ Proposed rule published
More informationCHATSWORTH WATER WORKS COMMISSION GREASE AND OIL CONTROL ORDINANCE
CHATSWORTH WATER WORKS COMMISSION GREASE AND OIL CONTROL ORDINANCE In an effort to curb sanitary overflows (SSOs) from grease accumulation in its sanitary sewer mains, Chatsworth Water Works Commission
More informationThe purpose of this rule is to limit VOC emissions from the transfer of organic liquids.
RULE 4624 TRANSFER OF ORGANIC LIQUID (Adopted April 11, 1991; Amended September 19, 1991; Amended May 21, 1992; Amended December 17, 1992; Amended December 20, 2007) 1.0 Purpose The purpose of this rule
More informationA high level overview of the federal NSPS and NESHAP rules as they apply to owner/operators of internal combustion engines
A high level overview of the federal NSPS and NESHAP rules as they apply to owner/operators of internal combustion engines Presented by: Brandon Guillory & Andy Goldberg AWMA October 29, 2009 1 New Source
More informationPart 70 Operating Permit Amendment
Part 70 Operating Permit Amendment Effective Date: February 18, 2016 Facility Name: Scherer Steam-Electric Generating Plant Facility Address 10986 Highway 87 Juliette, Georgia 31046, Monroe County Mailing
More informationAST REGISTRATION PIPE INSPECTION PE REQUIREMENTS. David D. Bradeson, P.E. Chemung Contracting Corporation
AST REGISTRATION PIPE INSPECTION PE REQUIREMENTS David D. Bradeson, P.E. Chemung Contracting Corporation AST REGISTRATION REQUIRED 9 VAC 25-91-20 Part II individual tank of 660 gal. or greater or aggregate
More informationAIR QUALITY PERMIT. Kennesaw State University - Marietta Campus
AIR QUALITY PERMIT Permit No. Effective Date February 11, 2016 In accordance with the provisions of the Georgia Air Quality Act, O.C.G.A. Section 12-9-1, et seq and the Rules, Chapter 391-3-1, adopted
More informationPermit Holder. Permitted Equipment
Air Quality Registration Stationary Spark Ignition Internal Combustion Engine (Less than 400 Brake Horsepower) Permit No. Project No. Description Date Testing No Plant Number: Under the Direction of the
More informationPENNSYLVANIA ABOVE GROUND STORAGE TANKS
PENNSYLVANIA ABOVE GROUND STORAGE TANKS GZA GeoEnvironmental Inc. by Jeffrey Knepper, LRS, CPG July 27, 2017 PA CODE Chapter 245. Administration of the Storage Tank & Spill Prevention Program AST Definition
More informationGeorgia Drycleaner Compliance Calendar
2011 Georgia Drycleaner Compliance Calendar Georgia Small Business Environmental Assistance Program 4244 International Parkway Suite 120 Atlanta, Georgia 30354 (404) 362-4842 or toll free at 1-877-427-6255
More informationOKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS
OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS PO BOX 52000 OKC, OK 73152-2000 www.occeweb.com Created on 10/1/2008
More informationOWS OPERATIONS & MAINTENANCE
SUPPLEMENTAL INSTRUCTIONS 1. INTRODUCTION 1.1. Containment Solutions manufactures Oil/Water Separator (OWS) tanks with internal coalescing plates. These units are available in single or double-wall model
More informationThe Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706
DRAFT Permit: APC-2004/0721-CONSTRUCTION (NSPS) Two Package Boilers The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706 ATTENTION: Andrew Kenner
More informationWA San Joaquin Valley Imo AIR POLLUTION CONTROL DISTRICT
WA San Joaquin Valley Imo AIR POLLUTION CONTROL DISTRICT NOV 2 6 20N HEALTHY AIR LIVING Ms. Carol Romero Pacific Ethanol Madera LLC 400 Capital Mall, Suite 2060 Sacramento, CA 95814 Re: Notice of Significant
More informationRICE NESHAP Implementation. Ray Lukkarinen, P.E. Stanley Consultants, Inc.
RICE NESHAP Implementation Ray Lukkarinen, P.E. Stanley Consultants, Inc. Presentation Outline RICE NESHAP Overview (Existing CI Engines) Definition Compliance deadline Engine Categories CO Emission Limits
More informationStorage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations
Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations ESAM Lunch and Learn Dartmouth, NS October 12, 2016 Part 2 of 2 Outline of Presentation 1. Purpose of the Regulations
More informationPermit Holder. Permitted Equipment
Air Quality Registration Stationary Compression Ignition Internal Combustion Engine (Less than 400 Brake Horsepower) Permit No. Project No. Description Date Testing No Plant Number: Under the Direction
More informationNew Federal Regulations for Internal Combustion Engines. Doug Parce
New Federal Regulations for Internal Combustion Engines Doug Parce Pertinent Federal Regulations National Emission Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion
More informationState of New Jersey. General Permit (GP-009A)
03/21/2013 State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP-009A) For Boiler(s) and Indirect Fired Process Heater(s) Each Greater Than or Equal to 10
More informationThis is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"
This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)" Note to Permit Writer: This condition is for existing engines (commenced
More informationThe purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.
RULE 4622 GASOLINE TRANSFER INTO MOTOR VEHICLE FUEL TANKS (Adopted May 21, 1992; Amended November 18, 1992; Amended December 17, 1992; Amended February 17, 1994; Amended June 18, 1998; Amended September
More informationThe purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.
RULE 4622 GASOLINE TRANSFER INTO MOTOR VEHICLE FUEL TANKS (Adopted May 21, 1992; Amended November 18, 1992; Amended December 17, 1992; Amended February 17, 1994; Amended June 18, 1998; Amended September
More informationIndustrial, Commercial and Institutional Boilers Maximum Achievable Control Technology ( IB-MACT) 5/28/15 Katie Cunningham
Industrial, Commercial and Institutional Boilers Maximum Achievable Control Technology ( IB-MACT) 5/28/15 Katie Cunningham Consumers Energy and Michigan Provides electric and natural gas service to 6.5
More informationMARAMA 2015 SCIENCE MEETING JULY 29-30, 2015 RICHMOND, VIRGINIA
Air Permitting of Sources at Natural gas Production, Compression and Processing Facilities MARAMA 2015 SCIENCE MEETING JULY 29-30, 2015 RICHMOND, VIRGINIA Tom Wolf, Governor John Quigley, Secretary Overview
More informationState of New Jersey. Department of Environmental Protection Air Quality Permitting. General Permit (GP-004A) For FUEL DISPENSING FACILITIES
State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP-004A) For FUEL DISPENSING FACILITIES This General Permit allows for the construction, installation,
More informationState of New Jersey. Department of Environmental Protection Air Quality Permitting
State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP-004B) for Fuel Dispensing Facility Equipped with a Phase I Vapor Recovery Control System This General
More informationRULE 326. STORAGE OF REACTIVE ORGANIC COMPOUND LIQUIDS. (Adopted 12/14/1993, revised 1/18/2001)
RULE 326. STORAGE OF REACTIVE ORGANIC COMPOUND LIQUIDS. (Adopted 12/14/1993, revised 1/18/2001) A. Applicability This rule applies to equipment used to store reactive organic compound (ROC) liquids with
More informationCenter Point Terminal Company, LLC Permit #: 2355-A AFIN: Table of Contents
Center Point Terminal Company, LLC Permit #: 2355-A AFIN: 60-01218 Table of Contents Section I: FACILITY INFORMATION... 4 Section II: INTRODUCTION... 5 Summary of Permit Activity... 5 Process Description...
More informationStreamlining Multiple Applicable Requirements
Streamlining Multiple Applicable Requirements What is Streamlining? 1. Streamlining is the process of determining one set of requirements to be incorporated into the Title V permit from among multiple
More informationES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number
ES-301-1.01 Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number ES-301-1.01 Document Owner: John Hambright 1) Activity Description: Fueling Aircraft, Vehicles, and Auxiliary
More informationCommercial Fats, Oils & Grease Stephen Sealey
Commercial Fats, Oils & Grease Stephen Sealey Wastewater Compliance Specialist City of Columbia January 7 th & 8 th, 2014 1 What is FOG? Important Definitions Fat, oils, and grease (FOG) Any liquid or
More informationFlorida Community Services Corporation of Walton County d/b/a Regional Utilities (Regional) FOG Control Policy
Florida Community Services Corporation of Walton County d/b/a Regional Utilities (Regional) FOG Control Policy 1. Introduction Fats, Oils, & Grease (FOG) are one of the primary causes of stoppages, backups,
More informationGrease Inspection Program
Grease Inspection Program Dublin San Ramon Services District (DSRSD) must comply with federal and state pretreatment regulations. The Publicly Owned Treatment Work s (POTWs) are charged with enforcing
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that
More informationA Tool for Specifying Diesel Genset Replacements Steve Stassel, Gray Stassel Engineering
A Tool for Specifying Diesel Genset Replacements Steve Stassel, Gray Stassel Engineering Alaska Rural Energy Conference, April 28, 2016 (Technical Session 6, 10:30 am) EPA Regulations RICE NESHAP on or
More informationState of New Jersey Department of Environmental Protection Air Quality Permitting
State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP-019) For This General Permit (GP-019) allows for the construction, installation, reconstruction, modification
More information40 CFR 63, Subpart CCCCCC
0 CFR 3, Subpart CCCCCC The Unmatched Solution to Meeting U.S. EPA National Emissions Standards for New National Emission Standards have gone into effect for Hazardous Air Pollutants at Gasoline-Dispensing
More informationOverview of Revisions to the Federal Underground Storage Tank (UST) Regulations. Storage Tank Advisory Committee Harrisburg, PA September 1, 2015
Overview of Revisions to the Federal Underground Storage Tank (UST) Regulations Storage Tank Advisory Committee Harrisburg, PA September 1, 2015 Why is EPA making changes to the UST regulations? The Energy
More informationRICE NESHAP Frequently Asked Questions (FAQ)
RICE NESHAP Frequently Asked Questions (FAQ) What does RICE NESHAP mean? RICE NESHAP is an acronym for Reciprocating Internal Combustion Engines National Emission Standards for Hazardous Air Pollutants.
More informationGrant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005
Grant Guidelines To States For Implementing The Provision Of The Energy Policy Act Of 2005 U.S. Environmental Protection Agency Office of Underground Storage Tanks Washington, DC www.epa.gov/oust EPA 510-R-06-001
More informationFacility Name: Chevron Products Company Doraville Terminal City: Doraville County: DeKalb AIRS #: Application #: 40411
Facility Name: Chevron Products Company Doraville Terminal City: Doraville County: DeKalb AIRS #: 04-13-089-00100 Application #: 40411 Date SIP Application Received: September 28, 2015 Date Title V Application
More informationUS oil production hits 15-year high: DEC 04, 2012
Setting a New Standard!! US oil production hits 15-year high: DEC 04, 2012 Domestic crude oil production in September hit the highest monthly output since 1998, according to the U.S. Energy Information
More informationSECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)
SECTION 02554 - FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS) 1.1 SUMMARY A. Storage tanks, fuel oil, tank accessories, piping, valves, and specialties for fuel-oil distribution inside and
More informationAIR PERMIT ABBEVILLE, HENRY COUNTY, ALABAMA DESCRIPTION OF EQUIPMENT, ARTICLE OR DEVICE
AIR PERMIT PERMITTEE: FACILITY NAME: LOCATION: PEGASUS WEST, LLC PEGASUS WEST, LLC ABBEVILLE, HENRY COUNTY, ALABAMA PERMIT NUMBER 606-S008-X001 DESCRIPTION OF EQUIPMENT, ARTICLE OR DEVICE Sawmill Green
More informationRULE 2260 REGISTRATION FOR EQUIPMENT SUBJECT TO CALIFORNIA S GREENHOUSE GAS OIL AND GAS REGULATION
RULE 2260 REGISTRATION FOR EQUIPMENT SUBJECT TO CALIFORNIA S GREENHOUSE GAS OIL AND GAS REGULATION REGISTRATION # [region]-[facility ID#]-OILGAS-[registration #]-[mod #] FACILITY NAME: LOCATION: MAILING
More informationRULE 2280 PORTABLE EQUIPMENT REGISTRATION (Adopted October 20, 1994; Amended May 16, 1996)
RULE 2280 PORTABLE EQUIPMENT REGISTRATION (Adopted October 20, 1994; Amended May 16, 1996) 1.0 Purpose The purpose of this rule is to provide an administrative mechanism, and establish standards for registration
More informationJohn Benson David Hanny Barton & Loguidice, P.C.
John Benson David Hanny Barton & Loguidice, P.C. Environmental Regulations: An Alphabet Soup AAI UIC RCRA SPCC SPDES RMP CERCLA PBS CBS CAA CWA SPILLS DEC EPA OSHA Outline Regulatory Programs Lessons
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationSYNTHETIC MINOR OPERATING PERMIT
SYNTHETIC MINOR OPERATING PERMIT PERMITEE: Sklar Exploration Company, LLC FACILITY: Oil & Gas Production Area No. 6 LOCATION: Sections 13, 14, 18, & 24, T3N, R10E, Escambia Co., AL PERMIT NUMBER DESCRIPTION
More informationRULE LIQUEFIED PETROLEUM GAS TRANSFER OR DISPENSING (Adopted 1/13/2015)
VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.33 LIQUEFIED PETROLEUM GAS TRANSFER OR DISPENSING (Adopted 1/13/2015) A. Applicability and Purpose The purpose of this rule is to reduce Reactive Organic
More information1) Activity Description: Management of Petroleum Storage Tanks and Containers
ES-301-4.09 Management of Petroleum Storage Tanks and Containers Document Identification Number ES-301-4.09 Document Owner: John Hambright 1) Activity Description: Management of Petroleum Storage Tanks
More informationST. VINCENT AND THE GRENADINES
ST. VINCENT AND THE GRENADINES MARITIME ADMINISTRATION CIRCULAR N POL 012 AMENDMENTS OF THE SUPPLEMENT (FORM A AND B) OF THE IOPP CERTIFICATE TO: SHIPOWNERS, SHIPS OPERATORS AND MANAGERS, MASTERS, RECOGNIZED
More informationARKANSAS DEPARTMENT OF ENVIRONMENTAL QUALITY STATE INDUSTRIAL PERMIT INSPECTION FORM. Permit No.: 4369-WR-1 Inspection Date: September 7,2006
ARKANSAS DEPARTMENT OF ENVIRONMENTAL QUALITY STATE INDUSTRIAL PERMIT INSPECTION FORM Page 1 of 3 AFIN: 68-00040 Log No.: N36'15'31.4" W91'32'41.1" Permit No.: 4369-WR-1 Inspection Date: September 7,2006
More informationAQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual
AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual For Single-Wall and Double-Wall Fibreglass Underground Storage Tanks This Aquator Commercial Oil Water Separator (OWS)
More informationOwner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.
Owner s Manual Supplement Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.0L V8 OWNERS MANUAL SUPPLEMENT Table of Contents Refueling Your Vehicle...1
More informationChanges to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017
Changes to Chapter 62-761, Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017 Rule Organization The rule sections are reorganized a bit with separate sections now for:
More informationVehicle and Equipment Fueling
Vehicle and Equipment Fueling SC-20 Objectives Cover Contain Educate Reduce/Minimize Description Spills and leaks that occur during vehicle and equipment fueling can contribute hydrocarbons, oil and grease,
More informationGeneral Permit (005B) for Emergency Generator(s) burning Gaseous Fuels
GP-005B State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (005B) for Emergency Generator(s) burning Gaseous Fuels This general permit allows for the construction,
More informationTABLE B: SUBMITTALS. Fiscal Services 520 Lafayette Road North, St. Paul, Minnesota
TABLE B: SUBMITTALS Table B lists most of the submittals you must provide. Table B is divided into three sections; one-time submittals or notifications, intermittent submittals or notifications and recurring
More informationSafe Operating Procedure
Safe Operating Procedure (Revised 3/14) UNDERGROUND STORAGE TANKS SUMMARY OF REGULATORY REQUIREMENTS Underground storage tanks (UST) are defined as tanks containing petroleum or other regulated substances
More informationRULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)
RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006) 1.0 Purpose The purpose of this rule is to limit emissions
More informationRULE NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016)
VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.34 NOX REDUCTIONS FROM MISCELLANEOUS SOURCES (Adopted 12/13/2016) A. Purpose and Applicability The purpose of this rule is to reduce emissions of oxides
More informationDEP7007CC Compliance Certification
Commonwealth of Kentucky Natural Resources & Environmental Protection Cabinet Department for Environmental Protection DIVISION FOR AIR QUALITY DEP7007CC Compliance Certification Division Use Only ID# Permit
More informationCity of Washington, Kansas Electric Department. Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources
Ordinance No. 743 Exhibit A City of Washington, Kansas Electric Department Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources Page 1 of 7 1. INTRODUCTION The provisions of this
More informationSAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks
SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks Approved By: Signed Seyed Sadredin Director of Permit Services
More informationArea Source NESHAPS and Air Permits
Area Source NESHAPS and Air Permits 40 CFR 63 Subpart ZZZZ 40 CFR 63 Subpart JJJJJJ Richard Nelson Senior Air Quality Specialist (704) 336-6865 Richard.Nelson@MecklenburgCountyNC.gov Combustion Area Sources
More informationInstallation and Maintenance Manual CORRUGATED RIVETED GALVANIZED STEEL WATER STORAGE TANKS
BH TANK A Division Of American Tank Co., Inc. Installation and Maintenance Manual CORRUGATED RIVETED GALVANIZED STEEL WATER STORAGE TANKS American Tank Co., Inc. P.O. Box 340 Windsor CA 95492 www.bhtank.com
More informationNEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Dry Cleaner Compliance Calendar 2015
NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM Dry Cleaner Compliance Calendar 2015 Welcome The New Jersey Small Business Environmental Assistance Program developed this guidance document to
More informationPRE-INSTALLATION GUIDE
Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.
More informationReducing Vent Gas Emissions with New Rod Sealing Solutions for Reciprocating Compressors. Jack Schwaller Hoerbiger Corporation of America
Reducing Vent Gas Emissions with New Rod Sealing Solutions for Reciprocating Compressors Jack Schwaller Hoerbiger Corporation of America The HOERBIGER Group headquartered in Zug, Switzerland, is a global
More informationRICE MACT / NSPS Update: How to Make Sense of this Difficult Issue
RICE MACT / NSPS Update: How to Make Sense of this Difficult Issue March 1, 2018 www.trcsolutions.com Overview Who is covered and by what rule? Brief overview of regulations What information you need to
More informationELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95)
RULE 69. ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95) (a) APPLICABILITY (1) Except as provided in Section (b) or otherwise specified
More informationPA RACT 2. Reasonably Available Control Technology. Presented by Suzanne Dibert
PA RACT 2 Reasonably Available Control Technology Presented by Suzanne Dibert Affected Facilities Facilities with potential emissions that exceed 100 tons per year (tpy) for NOx (nitrogen oxide) and 50
More informationCity of, Kansas Electric Department. Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources
Ordinance No. Exhibit A ----------------------------------------- City of, Kansas Electric Department Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources -------------------------------------
More informationRULE 903 MERCURY Adopted (Amended ) INDEX
RULE 903 MERCURY Adopted 6-2-75 (Amended 12-6-78) INDEX 100 GENERAL 101 PURPOSE 200 DEFINITIONS 201 CELL ROOM 202 CONDENSER STACK GASES 203 DENUDER 204 END BOX 205 END BOX VENTILATION SYSTEM 206 HYDROGEN
More informationARTICLE AIR POLLUTION CONTROL REGULATIONS AND PROCEDURES
TABLE OF CONTENTS ARTICLE 2.0000 AIR POLLUTION CONTROL REGULATIONS AND PROCEDURES Section 2.1400 Nitrogen Oxides 2.1401 Definitions... 214-01 2.1402 Applicability... 214-04 2.1403 Compliance Schedules...
More informationTypical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application
Typical Machine Tool Coolant Purification Unit Installation and Operating Manual Note: MSR provides a custom manual for every application Mohr Separations Research Model MSR-33 S Separator Customer: Background
More informationRULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008)
RULE 4306 BOILERS, STEAM GENERATORS, AND PROCESS HEATERS PHASE 3 (Adopted September 18, 2003; Amended March 17, 2005; Amended October 16, 2008) 1.0 Purpose The purpose of this rule is to limit emissions
More informationSTATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98)
RULE 69.3 STATIONARY GAS TURBINE ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted & Effective 9/27/94) (Rev. Adopted & Effective 12/16/98) (a) APPLICABILITY This rule shall apply to any stationary
More informationPERMIT APPLICATION REVIEW SUMMARY
PERMIT APPLICATION REVIEW SUMMARY New Hampshire Department of Environmental Services Air Resources Division P.O. Box 95, 29 Hazen Drive Concord, NH 03302-0095 Phone: 603-271-1370 Fax: 603-271-7053 AFS
More informationABOVEGROUND STORAGE TANK REGULATIONS -ADAM WILSON SLS LAND & ENERGY DEVELOPMENT
ABOVEGROUND STORAGE TANK REGULATIONS -ADAM WILSON SLS LAND & ENERGY DEVELOPMENT WHAT IS AN AST? VOLUME GREATER THAN 1320 GALLONS CONTENTS ARE LIQUID AT STANDARD TEMPERATURE AND PRESSURE GREATER THAN 90%
More informationTITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 100. AIR POLLUTION CONTROL
TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 100. AIR POLLUTION CONTROL SUBCHAPTER 39. EMISSION OF VOLATILE ORGANIC COMPOUNDS (VOCS) IN NONATTAINMENT AREAS AND FORMER NONATTAINMENT AREAS PART
More informationKESSEL-Grease Separator Under sink
INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL-Grease Separator Under sink Order Number 93025.00/US Product advantages Compact structure fully adjustable inlet 290 to 420 260 350 release
More informationSOUTH DAKOTA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES PREVENTION OF SIGNIFICANT DETERIORATION AIR QUALITY PRECONSTRUCTION PERMIT
Permit #: Effective Date: 28.0701 -PSD Draft SOUTH DAKOTA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES PREVENTION OF SIGNIFICANT DETERIORATION AIR QUALITY PRECONSTRUCTION PERMIT Steven M Pirner, Secretary
More informationMajor/Area Source. Speaker: Eric Swisher. 23rd Virginia Environmental Symposium April 11, Your environmental compliance is clearly our business.
Major/Area Source Boiler MACT Rule Speaker: Eric Swisher 23rd Virginia Environmental Symposium April 11, 2012 Your environmental compliance is clearly our business. Overview Ground Rules Regulatory Framework
More information