Basic Characteristics Data

Similar documents
Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

1 Terminal Block A-22

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

1. DBS series. Applications Manual

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Applications Manual. Table of contents. 1. DBS series. 2. CBS series. 3. CDS series. 4. Application Circuits. 6. DPA and DPF series. 7.

Basic Characteristics Data

Basic Characteristics Data

ZWD100PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual

Applications Manual of DPG serises

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

LS200 Series Instruction Manual

DC9~ typ max 40max 80max. 71 typ max. 120max 120max. 120max. 120max. 60max. 48max. 20max

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

PFE700SA Series Instruction Manual

Switching Power Supply

DRB-1 Series Instruction Manual

DRL-1 Series Instruction Manual

HWS 15A-150A Series. Instruction Manual

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

PFE1000FA Series. Instruction Manual

TDK-Lambda ZWS240BP/A SPECIFICATIONS

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

PAF SERIES. Features. Model naming method PAF 500 F / Conformity to RoHS Directive. Applications. Product Line up. DC/DC Module 400W-700W PAF

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H

PAF500F24 SERIES Instruction Manual

PAF F280 SERIES Instruction Manual

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

CCG Series Instruction Manual

Instruction Manual. TDK-Lambda. PFE300SA 500SA Series INSTRUCTION MANUAL

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

MODEL LEP100F-24 LEP100F-36 LEP100F-48 DC OUTPUT +24V 4.2(Peak 7)A +36V 2.8(Peak 4.7)A +48V 2.1(Peak 3.5)A

(typ.) (Range) ±18 330# 89 MPW MPW

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

TDK Lambda TEP INSTRUCTION MANUAL

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

Five Improvements by Power Supply Modules. Switching power supply and power modules. External Dimensions / Pin assignment, SPM Series

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

CN100A110 SERIES Instruction Manual

TDK-Lambda ZWS300BAF/A

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

PAF F48 SERIES Instruction Manual

EVS RP6020. Instruction Manual

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

RP Instruction Manual

Power Supply Technical Information

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters

NXE1 Series Isolated 1W Single Output SM DC-DC Converters

Dual output. Fig. 2.1 Current foldback characteristics

HWS Series Instruction Manual

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

DH50 SERIES. DATASHEET Rev. A

2W, Low Cost DIP, Dual Output DC/DC Converters

MODEL MMC8A-1 MMC8A-2 MMC8A-3 V1 +5V 1.2A +5V 1.1A +5V 1.2A DC OUTPUT V2 +12V 0.1A +15V 0.1A +12V 0.1A V3-12V 0.1A -15V 0.1A -5V 0.

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ZWD100PAF. Conformity to RoHS Directive

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

TECHNICAL DATA Troubleshooting Tips for DC to DC Converter

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

C B. Operating up to 5000m altitude 5 year product warranty Models

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

(typ.) (Range) Load

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

CN-A110 SERIES Instruction Manual

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

POWER-WIN TECHNOLOGY CORP.

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

AC/DC Converter MBP250-2A13D13M

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Basic Characteristics Data

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

QHW050F1, QHW075F1, and QHW100F1 Power Modules: dc-dc Converters; 36 to 75 Vdc Input, 3.3 Vdc Output; 33 W to 66 W

Basic Characteristics Data

Transcription:

Basic Characteristics Data Basic Characteristics Data Model GHA3F GHA5F Circuit method Switching frequency [khz] boost chopper 6-22 LLC resonant converters 9-1 boost chopper 6-22 LLC resonant converters 9-1 Input current *1 [A] Inrush current protection Material PCB/Pattern Single sided Double sided Series/Parallel operation availability Series operation Parallel operation 3.3 Thermistor FR-4 Yes Yes No 5.4 Thermistor Aluminum/FR-4 Yes Yes Yes *2 GHA3F-SNF boost chopper 6-22 3.3 Thermistor FR-4 Yes Yes Yes No LLC resonant converters 9-1 GHA5F-SNF boost chopper 6-22 5.4 Thermistor Aluminum/FR-4 Yes Yes Yes *2 LLC resonant converters 9-1 *1 The value of input current is at ACIN 12V and rated load. *2 Parallel operation is available with P option. Refer to 5.1on the instruction manual. GHA-1

1 Function 1.1 Input voltage range 1.2 Inrush current limiting 1.3 Overcurrent protection 1.4 Overvoltage protection 1.5 Thermal protection 1.6 Output voltage adjustment range 1.7 Output ripple and ripple noise 1. Isolation GHA-13 2 Series Operation and Parallel Operation GHA-13 2.1 Series Operation 2.2 Parallel Operation GHA-13 GHA-13 3 Assembling and Installation GHA-13 3.1 Heat dissipation (derating) 3.2 Installation method 3.3 Mounting screw 3.4 Expectancy life and warranty 3.5 Extermal capcitor on the output side GHA-14 GHA-15 GHA-16 GHA-16 GHA-16 4 Ground GHA-16 5 Option and Others GHA-17 5.1 Outline of options 5.2 Medical Isolation Grade 5.3 Others GHA-17 GHA-19 GHA-19 GHA-11

1 Function 1.1 Input voltage range The range is from AC9V to AC264V or DC13V to DC37V (please see SPECIFICATIONS for details). In cases that conform with safety standard, input voltage range is AC1-AC24V (5/6Hz). (a) Recommended Capacity : 6.3A, slow -blow L DCIN FUSE N Fig.1.1 Connection method If input value doesn t fall within above range, a unit may not operate in accordance with specifications and/or start hunting or fail. If you need to apply a square waveform input voltage, which is commonly used in UPS and inverters, please contact us. When the input voltage changes suddenly, the output voltage accuracy might exceed the specification. Please contact us. 1.2 Inrush current limiting An inrush current limiting circuit is built-in. If you need to use a switch on the input side, please select one that can withstand an input inrush current. Thermistor is used in the inrush current limiting circuit. When you turn the power ON/OFF repeatedly within a short period of time, please have enough intervals so that a power supply cools down before being turned on. Surge current in the filter unit does not include. (.2ms or less). Remarks : Please avoid applying a voltage exceeding the rated voltage to an output terminal. Doing so may cause a power supply to malfunction or fail. If you cannot avoid doing so, for example, if you need to operate a motor, etc., please install an external diode on the output terminal to protect the unit. 1.5 Thermal protection Over Temperature Protection (OTP) is built in. If this function is in operation, turn off power, eliminate all possible causes of overheating, and drop the temperature to nomal level. Output voltage recovers after applying input voltage. The recovery time varies depending on input voltage and load condition. 1Over rated temperature 2Poor ventilation 3 Over peak load based on 4. for Peak loading Remarks : Please comply with recommended mounting method in section 3.1. 1.6 Output voltage adjustment range To increase an output voltage, turn a built-in potentiometeris clockwise. To decrease the output voltage, turn it counterclockwise 1.7 Output ripple and ripple noise Output ripple noise may be influenced by measurement environment, measuring method Fig.1.2 is recommended. +Vout C1 C2 + Load 1.3 Overcurrent protection -Vout 15mm An overcurrent protection circuit is built-in and activated at 15% of the rated current. A unit automatically recovers when a fault condition is removed. Please do not use a unit in short circuit and/or under an overcurrent condition. Intermittent Operation Mode Intermittent operation for overcurrent protection is included in a part of series. When the overcurrent protection circuit is activated and the output voltage drops to a certain extent, the output becomes intermittent so that the average current will also decrease. 1.4 Overvoltage protection Osiloscope/ Ripple noise meter Bw:2MHz C1 : Film capacitor.1μf C2 : Aluminum electrolytic capacitor 22μF Differential probe Fig.1.2 Measuring method of Ripple and Ripple Noise Remarks : When GND cable of probe with flux of magnetic force from power supply are crossing, ripple and ripple noise might not measure correctly. Please note the measuring environment. An overvoltage protection circuit is built-in. If the overvoltage protection circuit is activated, shut down the input voltage, wait more than 3 minutes and turn on the AC input again to recover the output voltage. Recovery time varies depending on such factors as input voltage value at the time of the operation. Bad example Good example Fig.1.3 Example of measuring output ripple and ripple noise

1. Isolation For a receiving inspection, such as Hi-Pot test, gradually increase (decrease) the voltage for the start (shut down). Avoid using Hi- Pot tester with the timer because it may generate voltage a few times higher than the applied voltage, at ON/OFF of a timer. When you test a unit for isolation between the input and output, input and the terminal FG or between the output and the terminal FG, short-circuit between the output and the terminals RCG, PGG and AUXG. 2 Series Operation and Parallel Operation Please evaluate carefuly and test for any possible failure modes. Hot-swap or Hot-plug is not available. 3 Assembling and Installation Features of the cooling method GHA5F Cooling method Conduction cooling, forced air and convection cooling are available. The combination of the cooling method makes mechanical design flexible. 2.1 Series Operation Series operation is available by connecting the outputs of two or more power supplies with the same output voltage, as shown below. Output current in series connection should be lower than the lowest rated current in each unit. FAN : chassis : Heat dissipation Remarks : Please be sure to have enough cooling in case one of the power supply stops due to activation of the protection circuitry. Power + Supply - Power + Supply - Load Power + Supply - Power + Supply - Load Load 6)conduction cooling + forced air (Variable speed FAN) Combination Seal case FAN Fig.2.1 Examples of connecting in series operation 1)convection 2)conduction cooling 3)forced air 2.2 Parallel Operation Parallel operation Parallel operation is possible with option -P. Parallel operation is not available for the standard unit, please refer to the listed options. Redundancy operation Redundancy operation is available by wiring as shown below. Combination 4)convection + conduction cooling Combination 5)conduction cooling + forced air Power Supply Power Supply + - + - I1 I2 I3 Load Fig.2.2 Example of redundancy operation Even a slight difference in output voltage can affect the balance between the values of I1 and I2. Please make sure that the value of I3 does not exceed the rated current of a power supply. I3 [ the rated current value Fig.3.1 Cooling method Combination In order to determine if the power supply operates according to our specifications, the maximum operating temperature and temperature measuring points are shown in table 3.1., for reference. GHA3F Cooling method Both Forced air and convection cooling are available. (Fig 3.1 1),3),6)cooling method). Remarks: For proper operation of the power supply, please note the following: 1Heat dissipation (derating):section 3.1 reference -The temperature rise and heat dissipation of the converter must be GHA-13

GHA MADE IN JAPAN AC-DC Power Supplies Medical Type considered. -Conditions varies with environment and input voltage. -Mounting surface will be very hot during the operation,so please be careful not to touch the surface. 2Insulation distance: Please refer to Section 3.2 -AC voltage exist on the primary side therefore. -In order to prevent electric shock, or to meet the leakage current requirements of the safety standard, you need to ensure the proper insolation distance. 3Consideration at the Combination with Conduction cooling + Forced air cooling -GHA5F series can achieve the efficient heat dissipation by combining Conduction cooling and Forced air cooling. However, if the cooling fan stops due to the fan failure or other reason, Over Temperature Protection may not be activated due to the conduction cooling, and then the components temperature which are cooled by forced air (1, 2, 3 and 4 shown in table 3.1) would become high. Please ensure fail safe function of your product, and consult us for more details. 3.1 Heat dissipation (derating) Given the potential for variation between one application and another, the real test is to measure the critical components temperature rise when the power supply installed in the end-application. For reliable and safe operation, please make sure the maximum component temperatures rise given in table 3.1 is not exceeded. Please refer to Fig.3.4-3.9 for derating information based on different cooling methods. Operating at the maximum temperature rating results in 3-Years life expectancy. The actual life expectancy can be extended by reducing the ambient temperature. Please refer to section 3.4 f information. Test Measuring points Be aware of the conductive parts during the measurements. Please contact us f detail. 1 2 3 4 5 6 7 Remarks: There is a possibility that it is not possible to cool enough when the power supply is used by the sealing up space as showing in Fig.3.3. GHA5F (*) 1 6 4 2 Chassis Fig.3.3 Installation example Power supply (A) - (F) mounting -2-1 1 2 3 4 5 6 7 Ambient temperature [C] Fig.3.4 Forced air cooling derating curve (Reference value) Power [W] 55 5 45 4 35 *Maximum power with Forced air (Fig.3.5) 2. 2.5 3. 3.5 4. Wind velocity [m/s] Fig.3.5 The maximum output power by wind speed conditions 1 Point (a)upper substrate (b)lower substrate Fig.3.2 Temperature measurement points locations Table 3.1 Maximum operating temperature Parts name Symbol No. Maximum temperature[c] 5F 3F Remarks 1 Line Filter L11 115 115 2 Varistor SK11 76 76 3 Input Capacitor C16 9 9 4 Output Capacitor C56 7 7 5 Rectifier SS11 12 12 case temperature 6 Transformer T11 11 11 7 Output Choke L51 115 115 Aluminum base plate - * - *Operating ambient temperature derating of Conduction cooling (Fig.3.7) GHA-14 75 (C),(D),(E) mounting 5 (A) mounting (B) mounting (Pomax:15W) 25 (F) mounting -2-1 1 2 3 4 5 6 7 Ambient temperature [C] Fig.3.6 Convection cooling derating curve (Reference value)

1 (Pomax:36W) 75 (A) - (F) mounting 5 25-2 -1 1 2 3 4 5 6 7 Aluminum base plate temperature [C] Fig.3.7 Conduction cooling derating curve (Reference value) GHA3F (A) - (F) mounting (Pomax:3W) 1 6 4 Mounting method (A) (B) (C) CN11 CN11 CN11 Standard Position (D) (E) (F) CN11 CN11 CN11 Fig.3.11 Mounting method 3.2 Installation method During use, keep the distance between & d2 for to insulate between lead of component and metal chassis, use the spacer of 5mm between d2. If it is less than & d2, insert the insulation sheet between power supply and metal chassis. 2-2 -1 1 2 3 4 5 6 7 Ambient temperature [C] Fig.3. Forced air cooling derating curve (Reference value) GHA5F Component side 5mm min 1 75 (B),(C) mounting (D),(E) mounting 5 (Pomax:1W) 25 (A) mounting -2-1 1 2 3 4 5 6 7 Ambient temperature [C] Fig.3.9 Convection cooling derating curve (Reference value) GHA3F =4mm min Fig.3.12 Installation method Input voltage derating curve Derating curve depending on input voltage is Fig.3.1. For maximum power in each cooling method, please apply. 1 9 Component side 5mm min d2=5mmmin 7 6 9 115 Input Voltage [V] =4mm min Fig.3.1 Input voltage derating curve Fig.3.13 Installation method GHA-15

3.3 Mounting screw The mounting screw should be M3. The hatched area shows the allowance of metal parts for mounting. GHA3F, GHA5F CN11 Fig.3.14 Allowance of metal for mounting Unit [mm] If metallic fittings are used on the component side of the board, ensure there is no contact with surface mounted components. This product uses SMD technology. Please avoid the PCB installation method which includes the twisting stress or the bending stress. 3.4 Expectancy life and warranty Expectancy Life. Cooling Table 3.2 Life Expectancy (GHA5F-O) Mounting Average ambient temperature (year) Expectancy Life Io[75% 75%<Io[1% Ta = 35C or less 1years 6years A, C, D Ta = 4C 7years 4years B Ta = 45C 1years 7years Convection Ta = 3C or less 1years 7years E Ta = 35C 7years 5years F Ta = 3C 1years 7years Ta = 4C or less Over 1years Over 1years Forced air A,B,C,D,E,F Ta = 5C Over 1years Over 1years Cooling Table 3.3 Life Expectancy (GHA3F-O) Mounting Average ambient temperature (year) Expectancy Life Io[75% 75%<Io[1% A Ta = 3C Over 1years Over 1years B, C Ta = 45C Over 1years 7years Convection D Ta = 45C Over 1years Over 1years E Ta = 4C or less Over 1years 7years Ta = 45C Over 1years 6years Forced air A,B,C,D,E,F Ta = 4C or less Over 1years Over 1years Ta = 5C Over 1years Over 1years Remarks: Estimated life expectancy can be calculated by point temperature 3,4 shown in section 3.1. Please contact us for details. Warranty Cooling Mounting Table 3.4 Warranty (GHA5F-O) Average ambient temperature (year) Warranty Io[75% 75%<Io[1% Ta = 35C or less 5years 5years A, C, D Ta = 4C 5years 3years B Ta = 45C 5years 5years Convection Ta = 3C or less 5years 5years E Ta = 35C 5years 4years F Ta = 3C 5years 5years Ta = 4C or less 5years 4years Forced air A,B,C,D,E,F Ta = 5C 5years 3years Cooling Mounting Table 3.5 Warranty (GHA3F-O) Average ambient temperature (year) Warranty Io[75% 75%<Io[1% A Ta = 3C 5years 5years B, C Ta = 45C 5years 5years Convection D Ta = 45C 5years 5years E Ta = 4C or less 5years 5years Ta = 45C 5years 4years Forced air A,B,C,D,E,F Ta = 4C or less 5years 4years Ta = 5C 5years 3years *Warranty with conduction cooling is three years at the highest point of the temperature measurement. 3.5 Extermal capcitor on the output side When the load currnet changes rapidly, for output stability improvement, we recommend that you connect the capacitor to the output terminal. Tabel 3.6 External capacity on the output recommended capacity [μf] Output Voltage [V] Recommended capacity [μf] GHA3F-12 GHA5F-12 1.[Vo[13.2 2,2 to 22, GHA5F-15 13.5[Vo[16.5 2,2 to 1, GHA3F-24 GHA5F-24 21.6[Vo[26.4 3,3 to, GHA5F-3 27.[Vo[31.5 3,3 to, GHA3F-4 43.2[Vo<51. to 1, GHA5F-4 51.[Vo[52. to 12 GHA5F-56 52.[Vo[56. to 12 Remarks: When load current changes rapidly, some specifications may not meet the spec. Please mount power supply after enough evaluation and comply with recommended amount of capacitor. If you exceed the rated amount of capacitor, output for power supply may be stopped or power supply may be unsteable. 4 Ground GHA-16 In the case of the power installation, please be sure to connect two Input FG and mounting hole FG with safety ground of the chassis.

5 Option and Others 5.1 Outline of option J1 Option J1 units, the Input connector is VH connectors (Mfr. J.S.T.). J3 The input connector is VH connectors (Mfr. J.S.T.) and the connector is oriented horizonatally. Please contact us for details about appearance. Table 5.1 External capacitor on the recommended capacity of AUX2 recommended capacity [mf] Output Voltage GHA3/5F 5V (AUX2) 33 ~ 56 Please note that the ripple voltage of the main output may increase when the output current of AUX 2 is.1a or lower. Alarm -Table 5.2, see Fig 5.2 the internal structure circuit explaining the operation of the PG alarm. Table 5.2 Description of the alarm Alarm output condition Alarm output Or lowering of the rated output Open collector method voltage, output PG, PGG from Good : Low(-.5V 1mA max) PG terminal when you stop. *Output is unstable state when the overcurrent condition Bad : High or Open(4V.5mA max) Tr : 4V 1mA max.1mf 1kW PG CN11 AC(N) Tr AC(L) FG PGG Fig.5.2 Internal circuit of PG R3, SNF Fig.5.1 Example of option -J3 The following features are included. Dedicated harness. Please refer to the optional parts. AUX1 (12V±1% * R3 : 1.A, SNF :.5A) -This power supply is equipped with an axuiliary low power 12V * output AUX1 which is available from CN51. -AUX has been isolated from other circuit (input, output, FG, RC, PG). -Do not exceed the current rating, it may causes malfunction or failure of the internal circuitry. * GHA3F-SNF: 1V±1% AUX2 (5V1A) -Output AUX2 will be generated from CN51. AUX2 (5V±5% 1.A) can be used to power up remote control or other circuits. AUX has been isolated from other circuit (input, output, FG, RC, PG). -Do not exceed the current rating, it may causes malfunction or failure of the internal circuitry. -When the load currnet changes rapidly, for output stability improvement, we recommend that you connect the capacitor to the output terminal. Remote ON/OFF -You can operate the remote ON/OFF function by sending signals to CN51. Please see Table 5.3 for specifications and Fig.5.3 for connecting examples. -Remote ON/OFF circuits (RC and RCG) are isolated from input, output FG, AUX and PG. -Please note the followings when using the remote ON/OFF function. 1-R3 turns on by drawing current to RC, SNF turns off by drawing current to RC. 2The current flown to RC is a 5mA typ (maximum 3mA). 3If the output voltage is turned off through the remote ON/OFF circuit, 12V * AUX stops. 4If the output voltage is turned off through the remote ON/OFF circuit, PG signals turn to "High". 5If voltage or current of a value not listed in Table 5.3 is applied between RC and RCG, the output voltage may not be generated normally. 6Please wire carefully. If you wire wrongly, the internal components of a unit may be damaged. * GHA3F-SNF : 1V GHA-17

1 2 AC-DC Power Supplies Medical Type Table 5.3 Specifications of remote ON/OFF Fig.5.2 RC circuit example R3 SNF SW close SW open Output on (3mA min) (.1mA max) SW Logic SW open SW close Output off (.1mA max) (3mA min) H-SN-34 Optional harness or H-SN-35 (a) 5V 7 44W 3 4 AUX2 RC R1 V1 SW RCG AUX2G CN51 (Example V1 : 5V R1 : 27W) (b) 5V Fig.5.3 RC circuit example 7 44W 3 AUX2 RC 4 RCG SW AUX2G CN51 * If the output of an external power supply is within the range of 4.5-12.5V, you do not need a current limiting resistor R1. If the output exceeds 12.5V, however, please connect the current limiting resistor R1. To calculate a current limiting resistance value, please use the following equation. SNF R1[W]= V1-(1.1+RiX.5).5 Ri=44[W] Chassis and a cooling fan are added. Oil and chemical environment may cause of power supply s malfunction or failure. Please avoid operation and storage in such environments. Derating It should be satisfied that derating curve depending on input voltage in Fig.3.1 and derating curve on ambient temperature in Fig.5.5. As the verification method, temperature of measurement point A should be rated temperature or less in Table 5.4. 1 6 4 2-2 1 1 2 3 4 Ambient temperature [C] 5 6 7 Fig.5.5 Ambient temperature derating curve (Reference) When output current more than rated, output may shut down after 5 seconds. Recycle the input after 3 minutes to reset the protection. Maintenance of FAN FAN life time expectancy (R(t)=9%) in Fig.5.6 is depended on measurement point temperature in Fig.5.7, which exhaust air temperature from FAN at input terminal side. If load wires are generating heat, intake air temperature may become high. It may influence to FAN exhaust temperature. It is a notice that optical wires have to be selected for the avoidance. When FAN stop or air volume decrease happen, power supply s output will be shut down. Expected lifetime [H] 1,, 1, 1, 2 3 4 5 6 7 FAN exhaust temperature [C] Fig.5.6 Expected life time of FAN Measurement point Air flow 2mm Input Output Fig.5.7 Measurement of FAN exhaust temperature FAN Power supply (Top view) 7 Point A Fig.5.4 Measurement point A Mounting screw Screw length into power supply should be shorter than 6mm due to keep safety isolation clearance from inside components in Fig.5.. Please fix power supply surely by screws in consideration of the weight. Table 5.4 Rated temperature of measurement point A Ambient temperature Measurment 5C 7C Point A 65C or less 7C or less Chassis of customer system Chassis of power supply Screw M4 6mm max GHA-1 Fig.5. Mounting screw

A cooling FAN is built-in. Please keep 3mm clearance Air flow both input and output side to make enough air ventilation. Do not block off cooling FAN s air flow for stable operation. 3mm Input 3mm Output Air flow 3mm Input FAN 3mm Output Air flow 3mm Input Output 3mm 5.2 Medical Isolation Grade GHA series fit 2MOPP 2MOPP primary secondary 1MOPP (A) (B) (C) Fig.5.9 Clearance of input and output side When power supply is used where dust exist, it may cause of FAN failure. It is recommended to install a air filter to the system air ventilation duct. T3 M3 threaded mounting hole is available as an option ( T3). : Tap Case (a) T3 (Threaded mounting hole) (b) Standard (Through hole) Fig.5.1 Screw mounting image P Parallel operation is available (Recommended two). Output wattage setting is 9% per power supply of MAX OUTPUT WATTAGE. Remarks: -The difference of output voltage between power supply for parallel operation should be less.1v. -During parallel operation, higher voltage power supply become the master in system. Depend on voltage difference between master and slave, the master power supply may recover the system s required wattage up to 9% of MAX OUTPUT WATT- AGE. The master unit should be evaluated for heat dissipation, life expectancy and warranty period according to section 3.1-3.4. -Parallel operation, due to the fluctuation of load, the output voltage may be varied. There is a possibility that beat noise occurs due to the difference of the oscillation frequency. Please use after enough evaluation. -Forced air cooling is required. -Input voltage ought be AC115V. 5.3 Others Safety GND Fig.5.11 Medical Isolation Grade High voltage exist in the power supply for a few minutes after input voltage is stopped. Please pay attention to this during the maintence. Notes for mounting 1All Mounting holes should be tight and secured. 2Power supply should be mounted parallel to the mounting surface. 3Avoid applying mechanical stress or shock to the power supply. When power supply is energized or immidately after power supply stops working, power supply is still very hot, so please handle it with care. GHA-19