Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-19065-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2017-11-22 to 2022-11-21 Date of issue: 2017-11-22 Holder of certificate: TUV SUD China Holding Limited 5F, Communication Building.,163 Pingyun Road, Huangpu West Ave. GUANGZHOU CITY 510656, P. R. CHINA Test location: TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch, 5F, Communication Bldg.,163 Pingyun Road, Huangpu West Ave. GUANGZHOU CITY 510656, P. R. CHINA Tests in the fields: Photovoltaic Inverters and Wind Converters, ESS-Converters The laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, to use standard test methods listed here with different issue dates or revision status updates The testing laboratory maintains a current list of all testing within the flexible scope of accreditation 1/6
Simulation: 60kVA/50-60Hz DC-Simulator: 800VDC/100ADC or 1600VDC/50ADC Measurement capabilities 1000VAC, 1000AAC@ 50Hz 10AAC@ 10kHz 1000VDC, 140ADC DIN V VDE V 0126-1- 1: 2006+A1:2012 Automatic dis device between a generator and the public low-voltage grid DIN VDE V 0126-1- 1:2013 VDE-AR-N 4105: 2011 DIN V VDE V 0124-100:2012 IEC 62116:2008 IEC 62116:2014 EN 62116:2014 Automatic dis device between a generator and the public low-voltage grid Power generation systems connected to the low-voltage distribution network Technical minimum requirements for the to and parallel operation with lowvoltage integration of generator plants - Generator units - Test requirements for generation units to be connected and operated parallel with the lowvoltage Test procedure of islanding prevention measures for utility-interconnected photovoltaic inverters Test procedure of islanding prevention measures for utility-interconnected photovoltaic inverters Test procedure of islanding prevention measures for utility-interconnected photovoltaic inverters IEC 61727:2004 Photovoltaic (PV) systems - Characteristics of the utility interface EN 61727:1995 Photovoltaic (PV) systems - Characteristics of the utility interface AS 4777.2:2005 of energy systems via inverters, part 2: Inverter requirements Period of validity: 2017-11-22 to 2022-11-21 Date of issue: 2017-11-22 2/6
AS 4777.2:2015 AS 4777.3:2005 ER G83 issue2:2012 ER G59 issue2:2011 ER G59 issue3:2013 of energy systems via inverters, part 2: Inverter requirements of energy systems via inverters, part 3: protection requirements Recommendation for the Connection of Type Tested Small-scale Embedded Generators (Up to 16A per Phase) in Parallel with Low-Voltage Distribution Systems Recommendations for the of generating plant to the distribution systems of licensed distribution network operators RD 1663:2000 Spanish: Königliches Dekret 1663/2000, Connection of photovoltaic system to the lowvoltage grid network RD 661:2007 Spanish: Königliches Dekret 661/2007, About the generation of electric energy RD 1699:2011 ÖNORM E 8001-4- 712:2009 Technical Regulation 3.2.1:2016 UTE C 15-712-1: 2010 C10/11:2012 CEI 0-21:2012 Spanish: Königliches Dekret 1699/2011, the of generation system for electric energy with small power Austria: Erection of electrical installations with rated voltages up to AC 1000 V and DC 1500 V Part 4-712: Photovoltaic power-systems Erection and safety requirements systems Denmark: Technical regulation 3.2.1 for power plants up to and including 11 kw France: LOW-VOLTAGE ELECTRICAL INSTALLATIONS: Photovoltaic installations connected to the public distribution network Belgium: Technical requirements for specific production facilities decentralised running parallel on the distribution network of active and passive users to the LV electrical Utilities Period of validity: 2017-11-22 to 2022-11-21 Date of issue: 2017-11-22 3/6
CEI 0-21:2014 + V1:2014 CEI 0-21:2016 of active and passive users to the LV electrical Utilities of active and passive users to the LV electrical Utilities CEI 0-16: 2012 of active and passive consumers to the HV and MV electrical networks of distribution Company CEI 0-16:2014 + V1:2014 EN 50438:2007 EN 50438:2013 IEEE 1547:2003 IEEE 1547.1:2005 BDEW:2008+ Supplement 1/2009 7/2010 2/2011 1/2013 FGW TR3 Rev.23 FGW TR3 Rev.24 of active and passive consumers to the HV and MV electrical networks of distribution Company Requirements for the of microgenerators in parallel with public low-voltage Requirements for the of microgenerators in parallel with public low-voltage IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Resources with Electric Power Systems Technical Guideline Generating Plants Connected to the Medium- Voltage Network Guideline for generating plants to and parallel operation with the medium-voltage network Technical Guidelines for Power Generating Units Part 3 Determination of electrical characteristics of power generating units connected to MV, HV and EHV grids Period of validity: 2017-11-22 to 2022-11-21 Date of issue: 2017-11-22 4/6
FGW TR4 Rev.6 FGW TR4 Rev.7 FGW TR4 Rev.8 FGW TR8 Rev.6 FGW TR8 Rev.7 Technical Guidelines for Power Generating Units Part 4 Demands on Modelling and Validating Simulation Models of the Electrical Characteristics of Power Generating Units and Systems Technical Guidelines for Power Generating Units Part 8 Certification of the electrical characteristics of power generating units and systems in the medium-, high- and highestvoltage grids ABNT NBR 16149: 2013 ABNT NBR 16150: 2013 Photovoltaic (PV) systems Characteristics of the utility interface Photovoltaic (PV) systems Characteristics of the utility interface Conformity test procedure MEA Guideline 2013 Regulation for an Inverter Used in connected Power Generating System of the Metropolitan Electricity Authority (MEA) PEA Guideline 2013 PEA Guideline 2016 VDE-AR-E 2510-2: 2015 FNN Hinweis:2016 E VDE-AR-N 4110: 2017 UNE 206006: 2011 The Requirements on Connection of Provincial Electricity Authority(PEA) for VSPP The Requirements on Connection of Provincial Electricity Authority(PEA) for VSPP Stationary electrical energy storage systems intended for to the low voltage grid Anschluss und Betrieb von Speichern am Niederspannungsnetz Connection and operation of storage system to low voltage network Technical requirement for and operation of customer installations to the medium voltage network Performance tests for islanding detection of multiple grid-connected photovoltaic inverters in parallel UNE 206007-1: 2013 Requirements for connecting to the power system. Part1: -connected inverters Period of validity: 2017-11-22 to 2022-11-21 Date of issue: 2017-11-22 5/6
NRS 097-2-1:2017 inter of embedded generation Part 2: Small-scale embedded generation Period of validity: 2017-11-22 to 2022-11-21 Date of issue: 2017-11-22 6/6