AC/DC Converter MBP250-2A13D13M

Similar documents
DC/DC Converter URA(B)_LD-15WR2 & URA(B)_LD-20WR2 Series

FEATURES. Input Voltage (VDC) 3.3

DC/DC Converter URB1D_LMD-10WR3 Series

EMC Filter FC-CxxD Series

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series

DC/DC Converter URF48_QB-200W(F/H)R3 Series

DC/DC Converter URF48_QB-75W(F/H)R3 Series

D R C- 4 0 s e r i e s

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

S24SP series 40W Single Output DC/DC Converter

Industrial Power Supplies

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

GB60S 60W Single Output General Purpose Series

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

(typ.) (Range) Load

Series AM1P-Z 1 Watt DC-DC Converter

C B. Operating up to 5000m altitude 5 year product warranty Models

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Series AM2F-Z 2 Watt DC-DC Converter

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Features. Description. Table of Contents

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models

PG02S Series 2W DC/DC CONVERTER, SIP-Package

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

LS200 Series Instruction Manual

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

Series AM5T-Z 5 Watt DC-DC Converter

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

RCD15W Series PART NUMBER STRUCTURE

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Switching Power Supplies

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

POWER-WIN TECHNOLOGY CORP.

2W, Low Cost DIP, Dual Output DC/DC Converters

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

DIN Rail Power Supplies

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

UL Certified RP30-FW

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

N2POWER XLM240 AC-DC SERIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWER SUPPLY

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DRB-1 Series Instruction Manual

Series AM1G-NZ 1 Watt DC-DC Converter

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

Series AM2D-RZ 2 Watt DC-DC Converter

LW SERIES 5W WIDE INPUT RANGE

Switching Power Supplies

POWER-WIN TECHNOLOGY CORP.


LPF-25 series. 25W Constant Voltage + Constant Current LED Driver

N2POWER XLM500 AC-DC SERIES HIGH-EFFICIENCY ITE & MEDICAL SWITCHING POWER SUPPLY

S24SP15004 series 60W Single Output DC/DC Converter

Load (2) Single or Dual

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Series AM2D-Z 2 Watt DC-DC Converter

MD60 Series 60W DINergy Power Supply

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

EMERGENCY VEHICLE BATTERY MANAGER PS2024

TDK-Lambda ZWS240BP/A SPECIFICATIONS

ZWD100PAF Series Instruction Manual

RP40- _FR/ Package (4) CTRL Logic (3)

Series AM2S-Z 2 Watt DC-DC Converter

Specification of Battery Charger

ZWD225PAF Series Instruction Manual

IS 15885(Part 2/Sec13) R ( for 24V only)

DEWS SERIES 25W-30W WIDE INPUT RANGE

(typ.) (Range) ±18 330# 89 MPW MPW

DH50 SERIES. DATASHEET Rev. A

Transcription:

250W, 165-264VAC Input, Dual output AC/DC battery charging module power supply FEATURES Low stand-by power consumption, Maximum instantaneous power up to 350W With charging function, the 12V output Lead-acid battery can be charged, when system connected with battery, it can be used as uninterrupted power supply With charge and discharge management, battery status display, battery activation, external communications and control functions Output over-current, over-voltage protection, battery reverse polarity protection 2.5KVAC high isolation voltage RoHS Industrial grade operating temperature: -40 to +70 Chassis mounting is AC/DC battery charge power converter offered by Mornsun. It features wide input voltage range, taking both DC and AC input voltage, output over-current, over-voltage protection, strong ability in adapting power grid. This product has power working status display and Intelligent charging function, it can used to charge the 12V lead-acid battery, when AC is power-off, the battery can supply power to the load; it has battery activations and over discharge protection function, the activation maintenance of battery can be done manual or automatic through external signals. Designed specifically for distribution automation terminal (DTU / FTU). It is widely used in the power industry switch substations, power substation, RMU, Intelligent Package Substation, Intelligent Switch Controller and other industries which need uninterrupted power supply. Selection Guide Part No. Output Power Nominal Output Voltage and Current (Vo/Io) (VB/IB) Maximum Output Power Efficiency (220VAC, %) 81W 13.5V/4.5A 13.5V/1.5A 350W 83(Po=81W) Input Specifications Item Operating Conditions Min. Typ. Max. Unit Input Voltage Range AC input 165 220 264 VAC DC input 200 310 370 VDC Input frequency 40 50 60 Hz Input current 220VAC, Typical load -- -- 2.0 Inrush current 220VAC -- -- 60 A Hot Plug Unavailable Output Specifications Item Operating Conditions Min. Typ. Max. Unit Output Current Input voltage range, charge current (lb=1.5a) -- 6 13 (30S) 26 (1S) A Output Voltage Accuracy Input voltage range -- ±2 -- Output voltage accuracy Charge current accuracy -- ±10 -- Line Regulation Full load, do not connect the battery -- ±0.5 -- % Load Regulation 10%-100% load, do not connect the battery -- ±1 -- Ripple & Noise* 20MHz bandwidth (peak-to-peak value) -- -- 200 mv Battery charge current 1.35 1.5 1.65 A Battery discharge cut-off point Typical load 10.25 10.5 10.75 Battery activation finished point Typical load 11 11.25 11.5 V Battery under voltage alarm point Typical load 11 11.25 11.5 Battery discharge cut-off delay time Typical load -- 40 60 Remote control contact time Remote control activating function on/off -- 0.5 1 Remote control battery exit 3 4 5 s 2017.11.24-A/0 Page 1 of 7

Stand-by Power Consumption Input voltage range, Po=20W -- -- 40 VA Short Circuit Protection Input voltage range, disconnect the battery Hiccup, Continuous, self-recovery Over-current Protection 26 -- -- A Over-voltage Protection Input voltage range, do not connect the battery -- 18 -- V Battery Reverse Polarity Protection 1. When there is no AC input and battery reverse connection, press the battery start button, power supply will not have output, and the indicator doesn't light. 2. When battery is reverse connected, turn on the AC input, the under-voltage will light up. power supply have no output, but will not be damaged (No battery reverse connection, when there is AC input) Hold-up Time Input voltage range, Po=10W 500 -- -- ms Note: *Ripple and noise are measured by contact measuring method method, please see AC-DC Converter Application Notes for specific operation General Specifications Item Operating Conditions Min. Typ. Max. Unit Isolation Voltage Impulse Voltage Isolation Resistance Input-output 2500 -- -- Input-Case Test time: 1min 2500 -- -- output-case 2500 -- -- Input-output Apply 5kV impulse test voltage between input and output. Add 1.2/50us impact waveform, 5000 -- -- Input-Case including three positive impulse and three negative impulse whose time interval is no less 5000 -- -- output-case than 5 seconds. And there should not have disruptive discharge during the test. 5000 -- -- Input-output Room temperature 50 -- -- Input-Case Room temperature 50 -- -- output-case Room temperature 50 -- -- Operating Temperature* -40 -- +70 Storage Temperature -40 -- +105 Shell Operation temperature* -- -- +80 Storage Humidity -- -- 95 %RH MTBF MIL-HDBK-217F@25 >100,000 h Note: *When the ambient temperature exceeds 50, it should be taken the cooling method of force air cooling or post cooling to ensure that the module shield temperature is not more than 80. VAC V MΩ Physical Specifications Casing Material Package Dimensions Weight Cooling method Metal 168.00*111.20*42.50 mm 1.15Kg (Typ.) Free air convection EMC Specifications EMS ESD IEC/EN61000-4-2 Contact ±8KV Perf. Criteria B RS IEC/EN61000-4-3 3V/m perf. Criteria A EFT IEC/EN61000-4-4 Power port ±4KV perf. Criteria B IEC/EN61000-4-4 Signal port ±2KV perf. Criteria B Surge IEC/EN61000-4-5 Power port line to line ±2KV/line to ground ±4KV perf. Criteria B CS IEC/EN61000-4-6 10Vr.m.s perf. Criteria A PFM IEC/EN61000-4-8 100A/m perf. Criteria A Voltage dips, short interruptions and voltage variations immunity IEC/EN61000-4-11 0%,70% perf. Criteria B 2017.11.24-A/0 Page 2 of 7

Principle block diagram Fig1. Internal principle diagram Fig2. Internal isolation diagram Panel description 1.Charging and operation indicator light 4.Battery under-voltage indicator light 7.Manual activation quit button 2.Battery discharge indicator light 5.Battery fault indicator light 8.Manual battery input button 3.Battery activation indicator light 6.Manual activation start button 9.Manual battery quit button 10. 2017.11.24-A/0 Page 3 of 7

Wiring Description 1. Definition No. name Definition No. name 1 ACL AC input L phase 9 VH 2 PE Protective grounding 10 HK 3 ACN AC input N phase 11 HG 4 NC 5 VC 6 POK 7 HOK 8 VL No electrical connection Power supply for alarm unit (+5v to +24V DC) Input loss alarm signal output terminal Battery Activated state signal output terminal Battery under-voltage alarm signal output terminal 12 BG 13 RL 14 VG Definition Power supply fault alarm signal output terminal Remote activation start contact terminal Remote activation quit contact terminal Remote battery quit contact terminal Power supply for active discharge resistor (+) Remote public contact terminal 15 Vo- Load output (-) 16 Vo- Load output (-) No. name Definition 17 Vo+ Load output (+) 18 Vo+ Load output (+) 19 B+ Battery input (+) 20 B+ Battery input (+) 21 B- Battery input (-) 22 B- Battery input (-) 2.Wiring diagram FUSE Wiring Description: K1 K2 K3 are the contact points for the user s CPU and other control, R is the battery activated discharge resistance, load is the user's normal load, the battery is12v battery pack. capacity is 300V/15A. The specific use please refer to the Using Manual instructions 2017.11.24-A/0 Page 4 of 7

Manual Instruction 1. Power supply status indicator Charge, lights Green, Battery Charge indication, It lights when the battery is charging and off when the battery is discharging or activated. Discharge, lights Red, Battery Discharge indication, It lights when the battery is discharging or activated. It goes off when the battery is charging or complete discharging. Activate, lights Red, It lights when the battery is activated. If not, it goes off. Under Voltage, lights Red, It lights when the battery or the output converter under-voltage output. If not, it goes off. Fault, lights Red, In the fail case of over-voltage output, over-current, short circuit, It lights after the output is cut-off. If not, it goes off. 2. Button functions and use Activation Start, Press-button, Battery activation manually start. Activation Stop, Press-button, Battery activation manually quit. Battery Start, Press-button, Battery manually put into. Battery Stop, Press-button, Battery manually quit. Activated button, press the activated start-button then the converter will get into the battery activated state, and the discharged and activated indication lights on, and the battery discharge to the load and the discharged resistance. It is able to quit battery activated state when press the activated stop-button. If not, the converter will automatically finish battery activation Battery button, Press the battery start-button when project debugging or firstly connect the battery but no output, then the battery is used to supply power to the load. Now the discharge indication lights. It is able to manually press the battery stop-button 5 seconds to cut off the battery, or the battery will be automatically cut off after the battery discharge into the under-voltage breakpoint. Hold the battery start-button can urgently force the battery to output for the load when the battery voltage is lower than the under-voltage breakpoint. Note: The function of battery touch-button does not work when AC power. The time of forcing output should not be too long, so as not to damage the battery. 3. Use of Power The power supply can work when input is AC the alternating current. The power input current to load is powered by power supply, meanwhile charge battery in constant current and voltage. After the battery is charged, power supply to floating charge state automatically, this moment, the power supply float voltage and current to normal self discharge of battery. When AC power down, the battery can also supply power, 0 switch time. When the battery discharge to under voltage alarm, output battery under voltage signal point, at the same time under voltage indicator lamp light. When the battery discharge is lower than the under-voltage protection, the power shut off load output automatically. If need to shut off battery output in advance, can press the Manual battery quit button of the battery for manual operation in 5 seconds or remote control the relay controlled by the CPU to make the battery remote pin BG and VG in short circuit (not less than 5 seconds), then the battery shut off in advance. 4. Activation of Battery When the battery is in floating charge state for a long time, the battery should to be activated to avoid battery plate passivation. It can use the relay controlled by the CPU to make the power activation pin HK and VG in short circuit (not less than 0.5 seconds), then the power into activation state, the battery discharge and supply power to the load. When the battery discharged to the battery activation, the power automatic starting work to supply the load and charge the battery. When need to withdraw from activation halfway, can press the Manual activation quit button to withdraw from activation, or use the relay controlled by the CPU to make the power pin HG and VG in short circuit (not less than 0.5 seconds), then withdraw from activation in advance. Note: The activation function does not work when the power supply is not connected to the battery or the battery voltage is lower than the battery activation. 5. Application of activated discharge terminal RL Refer to the wiring diagram. The terminal is designed to accelerate the discharge of the battery when the battery is activated, please select the discharge resistance according to different battery capacity. When the power supply works normal, the resistance does not work, When the power source is in the activated state, the resistance is connected to the battery discharge. Choice of discharge current (recommended): Discharge current (A) = 0.1 * battery capacity (AH) - regular load current (A). If the discharge current value is negative, then the discharge resistance can not be added. When the discharge resistance is hot, should be properly cooled down and away from the power module. 6. Application of alarm terminal The alarm output terminal is the electronic node (see the internal diagram), and the +5V to +24V DC voltage is required to be input at the VC terminal. When an alarm occurs, the alarm node is on or off. Alarm node load capacity is 0-15mA, and the voltage derating is 2017.11.24-A/0 Page 5 of 7

0.1-3V. This alarm node is not suitable for the load of a large power, The alarm node must be isolated from the power input, output, housing, and protection (see Figure 2), and the insulation strength is 2500VAC voltage, insulation resistance is 50MΩ. Alarm status is as follows: Alarm terminal The alarm Normal ( or non-active) Alarm (or activation) VC Positive input alarm -- -- POK Input loss alarm on off HOK Activated state off on VL Battery under voltage alarm off on VH Fault alarm(over-voltage) off on 7. Use of Battery The power supply can be equipped with 6-30AH lead acid battery or colloidal maintenance-free battery, The battery is connected to the battery terminal(b+ B-) of the power supply. When the load current is less than 10A, the load is connected to the output terminal of the power supply. When the instantaneous load current exceeds 10A, the load can be directly connected to the battery, at this time, the power supply of discharge protection function is failure. Charge current selection of the power supply: Generally, The charge current of the battery is selected according to the battery capacity of 10% or parameters provided by battery manufacturers. The following table is for reference: battery capacity (AH) 15-20 charging current (A) 1.5 8. Battery anti-reverse connect protection (No battery reverse connection, when there is AC input.) 1 When there is no AC input and battery reverse connection, press the battery start button, power supply will not have output, and the indicator doesn't light. 2 When battery is reverse connected, turn on the AC input, the under-voltage will light up. In the above two cases, power supply have no output, but will not be damaged. After correct the battery's connection polarity, the power supply will work normally. Dimensions and Recommended Layout 2017.11.24-A/0 Page 6 of 7

Attention Matters in Application (1)Output please use wire that cross area is more than 2.5mm², input terminal should add 10A/250VAC Fuse. (2)Please correct connection according to the wiring diagram, do not connect wrongly, battery output terminal is strictly prohibited to connect reversely, AC input terminal is strictly prohibited connected with other terminals wrong, otherwise will cause permanent damage to power. (3)The installation method is installed on the vertical direction with terminal down, and identification right. (4)Connecting terminal capacity is 15A, the output and the battery terminal is applied to two terminals, otherwise it is easy to burn the connecting terminal. (5)Alarm terminal is prohibited from overload and short-circuit, otherwise it will burn down the electronic alarm contact. (6)To further reduce the output ripple noise, the user can parallel connection with one 220-470uF/63V electrolytic capacitor and 1uF multilayer Ceramic Capacitor. (7)The output of this product is not allowed to work in parallel. (8)The PE terminal of this product should be reliably connected to the earth, in order to improve the capability of anti-interference. (9)Casing will distribute heat when the power is during operating, in order to ensure the power dissipation is good, please keep a certain gap around the power supply to ensure the air flow smoothly, the temperature sensitive device as far as possible from the power. Note: 1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing bag number: 58220034; 2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all parameters in the datasheet; 3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75% with nominal input voltage and rated output load; 4. All index testing methods in this datasheet are based on our Company s corporate standards; 5. We can provide product customization service, please contact our technicians directly for specific information; 6. Products are related to laws and regulations: see "Features" and "EMC"; 7. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by qualified units. Mornsun Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: info@mornsun.cn 2017.11.24-A/0 Page 7 of 7