Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Similar documents
Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

MODELS F822 THRU F834

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Grinnell Grooved Fire Protection Products Grooved Fittings

Data Sheet Issue E

MEDIUM VELOCITY WATER SPRAY NOZZLE

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

FIRE SPRINKLER EQUIPMENT SUBMITTAL

Data Sheet 11.1 Issue A

model E Spray nozzles vk810 - vk817

Data Sheet 11.2 Issue B

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

MEDIUM VELOCITY WATER SPRAY NOZZLE

INSTALLATION & MAINTENANCE GUIDE

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

HR-20P Pneumatically Controlled Pressure Regulator

Model RM-1 Riser Manifold Commercial and Residential General Description

INSTALLATION, MAINTENANCE & SERVICE MANUAL

PPM EO-100 TM. Operation Manual

with the specific application. Always read and understand the installation

WATER SPRAY NOZZLE DATA SHEET

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

DAP-625S and DAP-875S

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

ProFlo FatBoy

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

Infrared Thermocouple Probe

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

A Member of the. Integrated Metering Technologies

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Do not install and/or operate this safety product unless you have read and understand the safety information contained

MODEL 900 IMPELLER-TYPE FLOW METER

Colt Series C400, C500

StormPro BA Series Sump Pump

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

A Member of the. Integrated Metering Technologies

WEB CONTROL PRODUCTS

INLINE FOAM INDUCTOR HD FIRE PROTECT PVT. LTD. TECHNICAL DATA DESCRIPTION SPECIFICATION APPLICATION SYSTEM DESIGN DETAILS

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

OPERATIONS MANUAL MODEL MT-500

MODEL 200 MULTI-JET FLOW METER

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

AMERICAN AVK COMPANY TABLE OF CONTENTS

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

SUNTURA SOLAR TRACKER

PT-516 Pumping Trap Installation and Maintenance

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Full Flow Drinking Water System Model: 3MFF100

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

G8 Portable Fuel Transfer Pump Owner s Manual

ESE Series Cast Iron Sewage Pumps

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

TECHNICAL DATA 1-1/2 (dn40)

FOR TECHNICAL ASSISTANCE

MODEL 1100 TURBINE FLOW METER

OWNERS MANUAL HF4263

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

Penguin Gentoo 600B Cordless Sprayer User s Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

Installation Guide. Marine Filter SURT023M SURT024M

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

Firstmate Installation Manual and User's Guide May, 2003

OWNERS MANUAL HF

Straight-Bore Clutch LSCC-32, 44, 54

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Reference Manual FM-200 Series

13101 / / and Installation Instructions

OPERATOR S MANUAL HD 2.3/24 P CD HD 2.3/23 P CD

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

V150 VERIS Verabar Installation and Maintenance Manual

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS AIR-COOLED AFTERCOOLER FOR COMPRESSED AIR SYSTEMS MODELS AC-140 thru AC-220 (ALL VOLTAGES)

Models P, P, P, , DANGER

A2P Single Phase Automatic Industrial Battery Charger

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Cabling for power, control, and video must be run to the installation site before the mount is installed.

AutoSparge. Lauter Tun Level Control. Operation, Assembly & Maintenance Manual

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Transcription:

Technical Services: Tel: () 31-931 / Fax: () 791-55 Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed for use in water spray fixed systems for fire protection applications where a high velocity water application may be required. There are two configurations: the basic Mulsifyre Nozzle shown in Figure 1 and the Mulsifyre Nozzle with Model F Dust Cap shown in Figure. Each configuration is available in six different models that provide a wide range of orifice sizes and water distribution characteristics. The Mulsifyre Nozzles are internal scroll type nozzles and they discharge a uniformly filled cone of relatively high velocity water droplets. Although the Mulsifyre Nozzles are designed primarily for use in fire extinguishment and control, they can also be used for exposure protection. The Mulsifyre Nozzles are typically used in water spray fixed systems for the protection of special hazards such as: oil filled transformers and switching equipment, flammable liquid and gas storage tanks, chemical process equipment, IMPORTANT Always refer to Technical Data Sheet TFP7 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the nozzle to fail to operate in a fire situation. conveyor systems, openings in fire walls, and other equipment that is defined as hazardous due to the possibility of a rapidly spreading fire. Mulsifyre Nozzles with Model F Dust Caps are used in applications where protection is required against insect infestation or accumulation of debris within the nozzle. The Dust Cap is designed for both indoor and outdoor use. It is recommended that the end user be consulted with respect to the suitability of the materials of construction for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, at a minimum, along with the corrosive nature to which the nozzles may be exposed. The Model F thru F3 Mulsifyre Nozzles are a redesignation for the Gem Model F thru F3. WARNINGS The Mulsifyre Nozzles described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The design of individual water spray fixed systems can vary considerably, depending on the characteristics and nature of the hazard, the basic purpose of the spraying system, the configuration of the hazard, and wind/draft conditions. Because of these variations as well as the wide range of available nozzle spray characteristics, the design of water spray fixed systems for fire protection must only be performed by experienced designers who thoroughly understand the limitations as well as capabilities of such systems. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Page 1 of APRIL, TFP1

Pageof TFP1 SCROLL (PASSES A 1/" PARTICLE) MODEL NUMBER NFPA (GPM psi) K-FACTOR ISO/SI (LPM bar) NOMINAL LENGTH "L" COLOR CODE 1" DIA. (5, mm) 3/" NPT BODY 1-1/1" (7 mm) ACROSS WRENCH FLATS "L" COLOR CODE PAINTED ON WRENCH FLATS F F F F F3 F3..3.7.., 33,1 3,9 37,, 5.1 73, 1-5/" ( mm) 1-5/" ( mm) 1-5/" ( mm) 1-11/1" (3 mm) 1-13/1" (7 mm) -3/" (7 mm) YELLOW RED ORANGE WHITE ALUMINUM GRAY FIGURE 1 MODEL F THRU F3 MULSIFYRE NOZZLES NOMINAL DIMENSIONS Technical Data Approvals The Model F thru F3 Mulsifyre Nozzles are UL and ULC Listed, as well as FM Approved. The Model F thru F3 Mulsifyre Nozzles with Model F Dust Caps areulandulclisted. Maximum Working Pressure 175 psi (1,1 bar). Also refer to Figure 3, Note. Discharge Coefficient RefertoFigure1. Water Distribution Refer to Figure. Optimum flow pressure is 3 to psi (,1 to,1 bar). Thread Connection 3/ inch NPT. Physical Characteristics (Basic Nozzle) Body.............. Brass Scroll.............. Brass Physical Characteristics (Nozzle with Dust Cap) Body..... Chrome Plated Brass Scroll.............. Brass Dust Cap........... EPDM Wire.......... Stainless Steel Design Criteria Nozzle Placement. Where direct impingement of water spray onto all of the protected surface is required by the Authority having Jurisdiction, the nozzles are to be spaced and directed so that their spray patterns will completely cover the plane-of-protection with the minimum required average density. With reference to Figure, use of the Design Spray Profile for the Design Spray Area will help assure that direct impingement on all surfaces will occur. The Design Spray Area shown at the top Figure - Part of on Page consists of the square of length S within the circular Overall Spray Area. The maximum recommended axial distances given in Figure are based on maintaining the specified spray patterns under a maximum wind condition of 15 MPH ( km/h). Dust Caps. The Model F Dust Caps are rated for indoor and outdoor use over a temperature range of -F to 15F (-51C to 5C). A minimum residual (flowing) pressure of 15 psi (1, bar) is required to assure release of the Dust Cap. Main Pipeline Strainers. Main pipeline strainers per NFPA 15 are required for systems utilizing Mulsifyre Nozzles since their waterways are less than 3/ inch (9,5 mm) diameter. Individual strainers are not required since the openings in the scrolls will pass a 1/ inch (3, mm) particle. FIGURE MULSIFYRE NOZZLES WITH DUST CAPS

TFP1 Page 3 of, 1,,, F 1, 1, NOZZLE, S: 1. Data applies to a maximum wind condition of 15 MPH ( km/h).. Data applies to a residual (flowing) pressure range at the nozzle inlet of 3 to psi (,1 to,1 bar). (For pressures up to 175 psi (1,1 bar) consult Tyco Fire & Building Products Technical Services.) 3. The shapes of the Design Spray Profiles remain essentially unchanged over the maximum recommended axial distance and the residual (flowing) pressure range of 3 to psi (,1 to,1 bar). DATA KEY OVERALL SPRAY PATTERN (RADIAL DISTANCE) DESIGN SPRAY PROFILE (S/) 1,,, 1,, F 3, 1 F 1, 1, 1 NOZZLE, NOZZLE, 1,, 3,,, 1, F3, 1, F3 1 1 1 NOZZLE, F 1, 1,, 3,, 1 1 1 NOZZLE,, 3,, 5, 1 1 1 1 NOZZLE, 1 1 FIGURE 3 PART 1 of WATER DISTRIBUTION DESIGN DATA

Pageof TFP1 MAXIMUM RECOMMENDED AXIAL DISTANCE TO PLANE OF PROTECTION, NOZZLE AXIAL DISTANCE DESIGN SPRAY PROFILE (GRAVITY) 1 17 1 15 1 13 1 11 1 9 7 5 3 1 (GRAVITY) F3 F F3 F F F ORIENTATION ANGLE (9 SHOWN) S/ PLANE OF PROTECTION S/ DESIGN SPRAY AREA FIGURE 3 PART of WATER DISTRIBUTION DESIGN DATA S OVERALL SPRAY AREA 3 5 9 1 135 15 1 ORIENTATION ANGLE 5,5 5,,5, 3,5 3,,5, 1,5 1,,5 S AXIS MAXIMUM RECOMMENDED AXIAL DISTANCE TO PLANE OF PROTECTION, METERS Installation Mulsifyre Nozzles must be installed in accordance with the following instructions: A leak tight 3/ inch NPT nozzle joint should be obtained with a torque of 1 to ft.lbs. (13, to, Nm). A maximum of 3 ft.lbs. (,7 Nm) of torque is to be used to install nozzles with 3/ NPT connections. Higher levels of torque may distort the nozzle inlet and cause leakage or impairment of the nozzle. Step 1. With pipe thread sealant applied to the pipe threads, hand tighten the nozzle into the nozzle fitting. Step. Tighten the nozzle into the nozzle fitting using an adjustable crescent wrench. With reference to Figure 1 the adjustable crescent wrench is to be applied to the wrench flats. REPLACEMENT DUST CAPS When replacement Dust Caps are installed, there is to be a minimum of 5 inches (15 mm) of Wire (Ref. Figure ) between where the Wire is looped around the nozzle thread relief and attached to the Dust Cap. The minimum length of 5 inches (15 mm) will help to assure that there will be an unrestricted flow from the nozzle outlet during operation. Care and Maintenance The Mulsifyre Nozzles must be maintained and serviced in accordance with the following instructions: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Mulsifyre Nozzles must never be painted, plated, coated or altered in any way after leaving the factory; otherwise, the spray performance may be impaired. Care must be exercised to avoid damage to the nozzles - before, during, and after installation. Nozzles damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Frequent visual inspections are rec-

TFP1 Page 5 of ommendedtobeinitiallyperformedfor nozzles installed in potentially corrosive atmospheres to verify the integrity of the materials of construction as they may be affected by the corrosive conditions present for a given installation. Thereafter, annual inspections per NFPA 5 are required. Water spray fixed systems for fire protection service require regularly scheduled care and maintenance by trained personnel. In addition to inspecting nozzles for proper spray performance during water flow trip tests of the system, it is recommended that nozzles be periodically inspected for broken or missing parts (including dust caps where applicable), loading/obstructions, or other evidence of impaired protection. The inspections should be scheduled weekly or as frequently as may be necessary, and corrective action must be taken to ensure that the nozzles will perform as intended in the event of a fire. For installations subject to freezing and where dust caps have been installed, a periodic inspection must be performed for evidence of ice build-up from trapped condensate which could affect the proper release of the dust cap. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 5), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that water spray fixed systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are warranted solely to the original Buyer for ten (1) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (1) years from date of shipment by TFBP. No warranty is given for products or components manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP s sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer s representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP s liability exceed an amount equal to the sales price. Theforegoingwarrantyismadeinlieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name and P/N. Contact your local distributor for availability. Mulsifyre Nozzles: Specify: Model (number) Mulsifyre Nozzle, P/N (specify). Model F............... P/N 9--1- Model F............... P/N 9--1- Model F............... P/N 9--1- Model F............... P/N 9--1- Model F3............... P/N 9--1-3 Model F3............... P/N 9--1-3 Mulsifyre Nozzles with Dust Caps: Specify: Model (number) Mulsifyre Nozzle with Model F Dust Cap, P/N (specify). Model F............... P/N 9-1-1- Model F............... P/N 9-1-1- Model F............... P/N 9-1-1- Model F............... P/N 9-1-1- Model F3............... P/N 9-1-1-3 Model F3............... P/N 9-1-1-3 Replacement Parts: Specify: Model F Dust Cap Assembly, P/N 5--1-1. The Model F Dust Cap may only be used for replacement on Mulsifyre Nozzles with chrome plated bodies. Otherwise failure for the Dust Cap to release may occur with resulting impairment of the system. Specify: Blow-Off Cap Assembly for use with discontinued Model FB thru F3B Mulsifyre Nozzles, P/N 5--1-1. The Blow-Off Cap Assembly may only be used with the previously offered Model FB thru F3B Mulsifyre Nozzles.

Pageof TFP1 TYCO FIRE & BUILDING PRODUCTS, 51 North Cannon Avenue, Lansdale, Pennsylvania 19