MODELS F822 THRU F834

Similar documents
Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

model E Spray nozzles vk810 - vk817

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

Data Sheet Issue E

Data Sheet 11.1 Issue A

WATER SPRAY NOZZLE DATA SHEET

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

Data Sheet 11.2 Issue B

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

Worldwide Contacts.

MEDIUM VELOCITY WATER SPRAY NOZZLE

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Technical Data. UL Listing is based on the following criteria:

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

MEDIUM VELOCITY WATER SPRAY NOZZLE

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

Model RM-1 Riser Manifold Commercial and Residential General Description

TECHNICAL DATA 1-1/2 (dn40)

Q= C v P S. Flow control valve Model j-2 Halar coated

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

Wet pipe low flow foam/water manifold system

TECHNICAL DATA OBSOLETE

with the specific application. Always read and understand the installation

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Worldwide Contacts. Technical Data

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Technical Data. Sizes 2 12 Inch (DN50 DN300)

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

MODEL 200 MULTI-JET FLOW METER

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

MODEL 900 IMPELLER-TYPE FLOW METER

WORKHORSE. Assembly / Operation Instructions / Parts

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

Price Book - Section 7 Nozzles and Sprinkler Accessories

Price Book - Section 7 Nozzles and Sprinkler Accessories

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

Solutions beyond products...

Assembly / Operation Instructions / Parts

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Instructions for Installation, Operation, Care and Maintenance

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA. Table Standard Materials

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

Model F1 Model F1 Recessed Standard Response Sprinklers

Model LA 4300 Time Delay OFF Controller

Instructions for Installation, Operation Care and Maintenance

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

WORKHORSE. Assembly / Operation Instructions / Parts 25 GALLON TRAILER SPRAYER

Installation, Operation & Maintenance Manual

TECHNICAL DATA. Trimpac 249a. September 16, 2013

Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS

WORKHORSE. Assembly / Operation Instructions / Parts

Instructions for Installation, Operation, Care and Maintenance

EMERGENCY EYE/FACE WASH

TECHNICAL DATA CAUTION

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

WORKHORSE. Assembly / Operation Instructions / Parts 15 GALLON TRAILER SPRAYER

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

200 & 300 Gallon 3 Point w/5880 Nozzle ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

INSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW

Model DDX Deluge Valve 8 (200mm) Features

SECTION DUST COLLECTOR

Tank Foam Generator OPERATION AND MAINTENANCE

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Model LA 4400 Time Delay OFF Controller

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Value Super Filter Max Installation Manual

Eye/Face Washes. FF G1778 Eye/FaceFWash,FWallFMountedFAutoFlow F90 FSwing-Down FFG1778LH-L FFG1778LH-R G1778L G1778LH G1778 G1778R.

Model LA 4100 Time Delay OFF Controller

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

FOR TECHNICAL ASSISTANCE

Features 1. Differential Latch-type, lightweight, dependable

FOR TECHNICAL ASSISTANCE

MODEL NO. LG Volt Lawn & Garden Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

SAFETY MANUAL READ FIRST!

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Transcription:

MULSIFYRE@ NOZZLES MODELS F822 THRU F834 *PASSES A 4s PARTICLE 1 /(6 (27mm) ACROSS WRENCH FLATS FIGURE A MODELS F822 THRU F834 MULSIFYRE NOZZLES GENERAL DESCRIPTION The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed for use in water spray fixed systems for fire protection applications. The 3/4 inch NPT series consists of three configurations: the basic Mulsifyre Nozzle shown in Figure A, with a Blow-off Cap Assembly as illustrated in Figure B, and with a Dust Cap as shown in Figure C. Each configuration is available in six different models which provide a wide range of orifice sizes and water distribution characteristics. The Mulsifyre Nozzles are internal scroll type nozzles and they discharge a uniformly filled cone of relatively high velocity water droplets. Although the Nozzles are designed primarily for use in fire extinguishment and control, they can also be used for exposure protection. FIGURE B MODELS F822B THRU F834B MULSIFYRE NOZZLES WITH BLOW-OFF CAP ASSEMBLY The Mulsifyre Nozzles are typically used in water spray fixed systems for the protection of special hazards such as: oil filled transformers and switching equipment, flammable liquid and gas storage tanks, chemical process equipment, 0 conveyor systems, @openings in fire walls, and other equipment that is defined as hazardous due to the possibility of a rapidly spreading fire. FIGURE C MODELS F822 THRU F834 MULSIFYRE NOZZLES WITH MODEL F880 DUST CAP ASSEMBLY Printed in U.S.A. 6-87 TD675

Mulsifyre Nozzles with Blow-off Cap Assemblies are designed to retain the priming water in ultrahigh speed, primed water spray deluge systems. They are typically used in conjunction with the 2 and 2-l/2 inch Model F460 Primac Valves as well as the 4 and 6 inch Model F461 Primac-Multimatic Valves. The F880 Dust Cap Assembly shown in Figure C is used in applications where protection is required against insect infestation or the accumulation of debris within the nozzle. The Dust Cap is designed for both indoor and outdoor use. APPROVALS AND STANDARDS The Models F822 through F834 Mulsifyre Nozzles and the Model F8BO Dust Cap Assembly are listed by Underwriters Laboratories Inc. and Underwriters Laboratories of Canada, and they are approved by the Factory Mutual Research Corporation. The Models F822B through F834B Mulsifyre Nozzles with Blow-off Cap Assembly are listed by Underwriters Laboratories Inc. and Underwriters Laboratories of Canada. WARNING The Mulsifyre Nozzles described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. The design of individual water spray fixed systems can vary considerably, depending on the characteristics and nature of the hazard, the basic purpose of the spraying system, the configuration of the hazard, and wind/ draft conditions. Because of these variations as well as the wide range of available nozzle spray characteristics, the design of water spray fixed systems for fire protection must only be performed by experienced designers who thoroughly understand the limitations as well as capabilities of such systems. The design of ultrahigh speed water spray systems for fire protection applications involves a technology which is substantially different from that associated with the design of automatic sprinkler or deluge systems. The speed of water delivery from all the nozzles of such systems is highly dependent on the nozzle discharge characteristics, the design of the detection system and piping network as well as the water supply characteristics and proper priming of the system. Consequently, the design of ultrahigh speed water spray systems for fire protection applications must only be performed by experienced designers who thoroughly understand the limitations as well as capabilities of such systems. The owner is responsible for maintaining his fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted relative to any questions. TECHNICAL DATA The 3/4 inch NPT series of Mulsifyre Nozzles are rated for use at a maximum service pressure of 175 psi. The nominal discharge curves for the various models are plotted in Figure D and the water distribution design data for residual (flowing) pressures of 30 to 60 psi are illustrated in Figure E. The Design Spray Area shown in the upper-right of Figure E consists of the square of length and width S within the circular. Overall Spray Area. NOTES Refer to the Warning Section for an important notice concerning the use of the water distnbuh on design data given in Figure E. Inquiries concerning nozzle installation and usage criteria, not covered by these instructions, should be mailed to the attention of the Technical Data Department. Include sketches and technical details, as appropriate. The Model F822B through F834B Mulsifyre Nozzles with the Blow-off Cap Assembly are rated for use with a maximum prime pressure of 12 psi (27.7 feet of water head), as measured at their inlet; and, a minimum residual (flowing) pressure of 30 psi is required to assure release of the Blow-off Cap Assembly. The Blow-off Cap Assembly is rated for use at a maximum service temperature of 15OF/65C. The Model F822 through F834 Mulsifyre Nozzles with the Model F880 Dust Cap Assembly are rated for both indoor and outdoor use over a temperature range of -6OF/-51C to The Body and Scrolls of the Mulsi- fyre Nozzles are brass per ASTM B16 (C36000). The openings in the Scrolls will pass a l/8 inch particle. The Mulsifyre Nozzles are supplied with chrome plated tips when used with either a Blow-off or Dust Cap Assem- bly. The Blow-off Cap Assembly (Ref. Figure B) consists of a Cap, Retaining Wire, O-ring, and Retaining Ring. The Cap is Delrinf 500AF (21% TFE) Type I, Class A per ASTM D2133; the approximately 12 inch long Retaining Wire is stainless steel; the O-ring is silicone rubber; and the Retaining Ring is Teflon? coated titanium per ASTM 8348. NOTES The tips of the Model F822B through F834B Mulsifyre Nozzles are specially machined to accept the Blow-off Cap Assembly and, consequently, the Nozzle and Blow-off Cap are ordered as an assembly, The Model F880 Dust Cap Assembly (Ref. Figure C) has an EPDM Cap and approximately 12 inches of stainless steel wire is connected to a brass eyelet in the Cap, to prevent the Cap from becoming lost after its release from the Mulsifyre Nozzle. NOTE The Model F822 through F834 Mulsifyre Nozzles must be factory chrome plated to accept the Dust Cap Assembly and, consequently, the Nozzle and Dust Cap are ordered as an assembly. SYSTEM DESIGN PARAMETERS Main line pipe strainers are required for all systems using the 3/4 inch NPT series of Mulsifyre Nozzles since their waterways are less than 3/8 inch diameter. Individual strainers are not required since the openings in the scrolls will pass a l/8 inch particle. When using the F822B through F834B Mulsifyre Nozzles in ultrahigh speed, primed water spray deluge systems, they should be orientated with their centerlines at least 3 (i.e., slope of 1 ft./20 ft) below horizontal, in order to prevent an excessive amount of air from becoming trapped within the nozzle and the connecting piping. Trapped air pockets will increase the water discharge time. 15OF/65C; and, a minimum residual (flowing) pressure of 15 psi is required to assure release of the Dust Cap INSTALLATION Assembly. The Mulsifyre Nozzles must be in- -2- fdupont Registered Trademark

that the nozzles will perform as intended in the event of a fire. It is also recommended that outdoor installations of Mulsifyre Nozzles with Dust Caps be periodically inspected, during freezing weather conditions, for the presence of ice build-up from trapped condensate which could affect the proper release of the Dust Caps. NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authon ties and all personnel who may be affected by this action must be notified. It is recommended that water spray fixed systems for fire protection be inspected by a qualified Inspection Service. ORDERING PROCEDURE Mulsifyre Nozzles: Specify: Model (number) Mulsifyre Nozzle, PSN (specify). Model F822. PSN 49-800-l-822 Model F824.. PSN 49-800-l -824 Model F826.... PSN 49-800-l -826 Model F828... PSN 49-800-l -828 Model F832.... PSN 49-800-l-832 Model F834.... PSN 49-800-l -834 Mulsifyre Nozzles with Blow-off Cap: Soecifv: Model (number) Mulsifyre Nozzle with Blow-off Cap Assembly, PSN (specify,i. Model F8228... PSN 49-802-l -822 Model F824B.. PSN 49-802-l -824 Model F826B.. PSN 49-802-I-826 Model F828B... PSN 49-802-l -828 Model F832B. PSN 49-802-I-832 Model F834B. PSN 49-802-l-834 Mulsifyre Nozzles with Dust Cap: Specify: Model (number) Mulsifyre Nozzle with Model FBSO Dust Cap Assembly, PSN (specify). CONVERSION FACTORS Parenthetical metric conversions cited herein are approximate. 1 inch = 25.400 mm 1 foot = 0.3048 m 1 psi = 6.895 kpa = 0.0689 bar* = 0.0703 kg/cm2* 1 lb. = 0.4536 kg 1 U.S. gallon = 3.785 dm3 = 3.785 litres* *Not recognized International System units. WARRANTY Seller warrants for a period of one year from the date of shipment (warranty period) that the products furnished hereunder will be free from defects in material and workmanship. For further details on Warranty, see Price List. Model F822 PSN 49-801-l-822 Model F824,.. PSN 49-801-l-824 Model F826..... PSN 49-801-I-826 Model F828... PSN 49-801-I -828 Model F832.. PSN 49-801-l-832 Model F834... PSN 49-801-l -834 Replacement Parts: Specify: Blow-off Cap Assembly for use with Models F822B thru F834B Mulsifyre Nozzles, PSN 56-802-I - 001. Specify: Model F880 Dust Cap Assembly, PSN 56-880-I -001. NOTE The Model F880 Dust Cap Assembly can only be used as a replacement part on Model F822 thru F834 Mulsifyre Nozzles with a factory chrome plated nozzle tip. -5-

I I 2 3 m: NOZZLE 4 4 L If 5 w; 6 6 CMD&AT I ON (SO SHOWN) L DESIGN SPRAY AREA & 9 0 (GRAVITY) ti IO 10 5 II 11 k 0 12 I2 18 2 13 5 I4 I5 16 17 18 I3 14 15 16 I7 I8 17 16 I5 I4 13 I2 0123456 I I s 7, FEET IO 9 8 NOTES 1. Data applies to a maximum wind condition of 15 MPH. 7 6 5 F834 F828 F832 F824 2. Data applies to a residual (flowing) pressure range at the nozzle inlet of 30 to 60 psi. (For pressures up to 175 psi consult the Technical Data Department.) 3. The shapes of the Design Spray Profiles remain essentially unchanged over the maximum recommended axial distance and the residual (flowing) pressure range of 30 to 60 psi. 4 3 F822 2 I F826 n o 300 45 60 90 I200 135O 150 180 ( GRAVITY) ORIENTATION ANGLE 4. See Technical Data Sheet TD675T for Drawing Templates of the Design Spray Profiles. FIGURE E WATER DISTRIBUTION DESIGN DATA -4-

60 55 35 30 10 15 20 25 30 35 40 DISCHARGE IN U. S. GALLONS PER MINUTE (GPM) NOTE: Q = K<p; where 0 = flow in U.S. gallons per minute, p = pressure in pounds per square inch, and K is the nominal discharge coefficient. 3.5 2.0 40 50 60 70 80 90 100 110 120 130 140 150 160 DISCHARGE IN LITERS PER MINUTE NOTE: Q = K<p; where Q = flow in liters per minute, p = pressure in bars, and K is the nominal discharge coefficient, FIGURE D NOMINAL DISCHARGE CURVES stalled by wrenching only on the hex portion of the Mulsifyre Body. When reattaching the Blow-off Cap Assembly to an F822B through F834B Mulsifyre Nozzle, apply a slowly increasing force against the end of the Blow-off Cap and press until the Retaining Ring snaps into position. CARE AND MAINTENANCE Care must be exercised to avoid damage to the nozzles - both before and after installation. Nozzles damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Water spray fixed systems for fire protection service require regularly sched- uled care and maintenance by trained personnel. It is recommended that the Mulsifyre Nozzles be periodically inspected for broken or missing caps, loading/obstructions, or other evidence of impaired protection. The inspections should be scheduled weekly or as frequently as may be necessary and, corrective action taken to ensure -3-

MULSIFYRE NOZZLES, MODELS F822 THRU F834 @ Reg. trademark of GRINNELL CORPORATION, 3 TYCO PARK, EXETER, NH 03833 A t~cx3international LTD. COMPANY