Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Similar documents
Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

Application Note. Authors. Abstract. Energy & Chemicals

Neueste LC Entwicklungen

Determination of Sudan Dyes I IV in Curry Paste

Technical Overview. Introduction

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC

Agilent G5632 Valve Kit Instructions

Application Note. Abstract. Authors. Environmental Analysis

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Agilent 1290 Infinity Autosampler

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

Boosting Trace Detection Performance with the Vanquish Diode Array Detector and High-Sensitivity LightPipe Flow Cell

Agilent 1290 Infinity II Ultra Low Dispersion Kit

HyperShear TM HPLC Mixers

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

HIGH PRESSURE SWITCHING VALVES

HyperShear TM HPLC Mixers

HyperShear TM HPLC and UHPLC Mixers

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Stability Axial Compression Technology Application Ordering Information

S 1125 HPLC Pump System

C196-E081C. Ultra High Performance Liquid Chromatograph Nexera X2. Specifications

Using the PSD for Backflushing on the Agilent 8890 GC System

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

VERITY Purification Systems Build the perfect system to fit your research

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS

HPLC SYSTEM S 500 SERIES

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Agilent Valve Kit G4231A/B and G4232A/B/C

NEW HPLC - SYSTEM LINE

HyperShear TM HPLC and UHPLC Mixers

Analysis of Petroleum Fractions by ASTM D2887

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

HPLC System S 600 Series

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment

Dual-Needle Infinity II Upgrade Kit

Agilent InfinityLab LC Series Multi-wash Upgrade Kit

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Agilent Online-SPE Direct Inject Kit G4744A

Supplementary Material

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

System Manual. Agilent 1260 Infinity Capillary LC System

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Phase Distribution of Ethanol, and Water in Ethyl Esters at K and K

Technical Procedure for Gas Chromatography (GC-FID)

Agilent 1100 Series Capillary LC System. System Manual

Agilent Multimode Inlet for Gas Chromatography

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Agilent 7693A Automated Liquid Sampler

Liquid Chromatography

Quality-by-Design in Method Development. Mijo Stanic General Manager and Technical Director

The Vanquish Platform: Improved Throughput and Resolution of Xanthones in Mangosteen Pericarp

Application. Gas Chromatography June 1995

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

Agilent 1260 Infinity Bio-inert High Performance Autosampler

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

ACQUITY UPLC I-Class System with 2D Technology

Application Note. Author. Introduction. Energy and Fuels

The Only No Compromise

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Agilent G4236A 2D-LC Valve Installation Guide

InertSustainSwift. Achieving separations faster than ever before

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS

Agilent 1200 Series Valves

Beverage Grade Carbon Dioxide

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems

1260 Infinity II Multicolumn Thermostat

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

ACQUITY UPLC I-Class System Specifications

S-PRO 3200 GC System for Sulfur Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Agilent 7693A Automated Liquid Sampler

Pipetted Liquid Sampling. Automated sample preparation platform for online LC-MS/MS bioanalysis

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent

Transcription:

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 129 Infinity II HDR-DAD Impurity Analyzer Solution Application ote Small Molecule Pharmaceuticals Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany Abstract The Agilent 129 Infi nity II High Dynamic Range Diode Array Detection (HDR-DAD) Impurity Analyzer Solution combines the signals from two diode array detectors with different path length Max-Light cartridge cells to increase the linear dynamic UV-range. This solution can be used to detect and quantify main and trace compounds in a single run without exceeding the linear UV-range. Using one DAD with a 1-mm fl ow cell, typically two injections with different injection volumes are needed to determine low-dose, high-dose, and trace compounds. This Application ote demonstrates that one injection is adequate to reliably quantify low-dose, high-dose, and trace compounds of a fi xed-dose combination drug using the Agilent 129 Infi nity II HDR-DAD Impurity Analyzer Solution.

Introduction Fixed-dose combination drugs are used in the medication of various disease patterns. The composition percentage of the active ingredients can vary depending on the desired physiological effect. If high-dose and low-dose ingredients are combined, the analysis using conventional HPLC and UHPLC diode array detectors may need at least two injections. This ensures that all compounds are quantified within the linear range of the detector with reliable integration and quantification of trace compounds. This Application ote shows that with the Agilent 129 Infinity II HDR DAD Impurity Analyzer Solution, high-dose and low-dose compounds, as well as their impurities can be determined in a single run with high sensitivity without exceeding the linear UV-range. Experimental Equipment The deployed Agilent 129 Infinity II LC system consisted of the following modules: Agilent 129 Infinity II High-Speed Pump (G712A) Solvents and samples Solvent A Water +.1 TFA Solvent B Acetonitrile +.9 % TFA Sample A fixed-dose combination drug with the following ingredients was used: and chlorphenamine at a ratio of 1:8, vitamin C, caffeine, and a small amount of unknown impurities (Figure 1). HO Cl H O Chlorphenamine CH 3 CH 3 CH3 H 3 C HO HO HO Fi gure 1. Ingredients of the fixed-dose combination drug: vitamin C, paracetamol, caffeine, and chlorphenamine. CH 3 O H O CH 3 OH O All solvents used were LC grade. Fresh ultrapure water was obtained from a Milli-Q Integral system equipped with a.22-μm membrane point-of-use cartridge (Millipak). The fixed-dose combination drug was bought in a local pharmacy. Sample preparation 1. Two capsules of a cold medication were opened and dissolved in 2 ml of distilled water. 2. Extract with an ultrasonic bath for 5 minutes. 3. Filter with an Agilent Premium Syringe Filter ylon,.45 μm, 15 mm (p/n 519 591) 4. Clear liquid was filled and stored in 1.5-mL LC vials containing: 25 ng/μl chlorphenamine 2, ng/μl paracetamol 2,5 ng/μl caffeine 15, ng/μl vitamin C Agilent 129 Infinity II Multisampler (G7167B) Agilent 129 Infinity II Multicolumn Thermostat (G7116B) Agilent 129 Infinity II Diode Array Detector (2x G7117B) with 3.7-mm, 1-mm and 6-mm Max-Light cartridge cells Column Agilent ZORBAX Eclipse Plus C18, 4.6 1 mm, 5 µm (p/n 959996-92) Software Agilent OpenLAB CDS ChemStation Edition for LC and LC/MS Systems, version C.1.7 [27] Table 1. Chromatographic conditions. Parameter Value Mobile phase A) Water +.1 % TFA B) Acetonitrile +.9 % TFA Flow rate 1 ml/min Gradient minutes 5 %B.5 minutes 5 %B 6.1 minutes 4 %B 6.5 minutes 95 %B Stop time 8 minutes Post time 5 minutes Injection volume 1 and 5 μl for 1-mm flow cell 5 µl for HDR DAD solution Column temperature 4 C Wavelength 254/2 nm, reference 38/8 nm Peak width >.25 minutes (.5-seconds response time) (1 Hz) 2

5. Dilution 1:2 with water containing: 12.5 ng/μl chlorphenamine Detector 1, with a 6-mm path length flow cell for the detection of low concentrations 1, ng/μl paracetamol 125 ng/μl caffeine 75 ng/μl vitamin C 6. This solution was injected. Principle of the Agilent 129 Infinity II HDR-DAD Impurity Analyzer Solution The Agilent 129 Infinity II HDR-DAD Impurity Analyzer Solution provides more than three times wider linear dynamic UV-range (typically 6.7 AU at 265 nm) compared to one 129 Infinity II DAD with a 1-mm Max-Light cartridge cell (greater than 2. AU at 265 nm). By combining the signals from two diode array detectors with different path length Max-Light cartridge cells, the HDR detection solution detects and quantifies components with significantly different concentrations in a single run. Two 129 Infinity II DADs are clustered (Figure 2). One 129 Infinity II DAD is equipped with a 6-mm path length cell to analyze lower concentrated compounds, and the second 129 Infinity II DAD is equipped with a 3.7-mm path length cell to analyze highly concentrated compounds. The 6-mm cell must be the first in the flow path followed by the 3.7-mm cell. The output signal is a combined signal, normalized to a 1-mm path length. The high dynamic range (HDR) tool is configured during instrument configuration. Both detectors are clustered, and the delay volume of the capillary connecting both detectors is entered. In the user interface, both detectors appear as one detector (Figure 3). Detector 2, with a 3.7-mm path length flow cell for the detection of high concentrations F igure 2. Clustered Agilent 129 Infinity II DADs. F igure 3. Activating the HDR tool in the Agilent ChemStation software. 3

Results and Discussion To evaluate the performance differences between the 129 Infinity II DAD and the 129 Infinity II HDR-DAD Impurity Analyzer Solution, the following experiments were performed: Analysis of a fixed-dose combination drug on a 129 Infinity II LC system with DAD and a 1-mm Max-Light cartridge cell using two injections of 1 and 5-μL volumes to determine high-dose and low-dose drugs and further trace compounds. Analysis of a fixed-dose combination drug on a 129 Infinity II LC system with the 129 Infinity II HDR-DAD Impurity Analyzer Solution using one 5-μL injection of to determine low-dose and high-dose drugs and further trace compounds within the typical linear UV range of 6.7 AU. For the first experiment, the 129 Infinity II DAD with the 1 mm Max-Light cartridge cell was used. Two injections were necessary to determine all compounds and trace impurities within the linear UV range (Figures 4 and 5). 1, 8 6 4 2 3,5 3, 2,5 2, 1,5 1, 5 A B A 1-µL injection determines the first three peaks. 1 2 3 4 5 Impurity 1 Impurity 2 A 5-µL injection determines chlorphenamine and further impurities. The first two peaks are out of linear range. 1 2 3 4 5 Chlorphenamine Fi gure 4. Chromatograms of the drug using two injections with different injection volumes using the Agilent 129 Infinity II DAD with 1-mm Max-Light cartridge cell., paracetamol, and caffeine were determined by injecting 1 μl. The maximum peak height was approximately 1,, which is within the linear UV range of the 129 Infinity II DAD. The other compounds were determined by injecting 5 μl. and paracetamol were now at a maximum peak height of 3, and 3,5, and, therefore, out of the linear UV range. Figure 5 shows, enlarged, the 1-µL (red) and 5-μL (blue) injections using the 129 Infinity II DAD. It was possible to reliably identify and determine chlorphenamine and further trace compounds with the 5-μL injection only. For chlorphenamine, the peak height for the 1-μL injection was as low as 3.8, whereas for the 5-μL injection, approximately 19 were achieved. 2 15 1 1-µL injection with 3.8 peak height for chlorphenamine 5-µL injection with 19.1 peak height for chlorphenamine Chlorphenamine 1.2 1.8.6.4.2 Chlorphenamine 4.4 4.5 4.6 4.7 4.8 4.9 5 5.1 5 3.5 4. 4.5 5. 5.5 6. Fig ure 5. Enlargement of the 1-µL (red) and 5-µL (blue) injections for the Agilent 129 Infinity II DAD with a 1-mm Max-Light cartridge cell. 4

This procedure ensured easier integration and, subsequently, more reliable quantification. Impurities 3 and 4 could only be analyzed by injecting 5 μl, and Impurities 1 and 2 elute earlier in the chromatogram. In a second experiment, 5 μl of the fixed-dose combination drug was injected using the 129 Infinity II HDR-DAD Impurity Analyzer Solution. Figure 6 shows an overlay of the 5-μL injection of the 129 Infinity II DAD signal (red) and the 129 Infinity II HDR DAD signal (blue). Using the 129 Infinity II HDR DAD signal, all peaks were within the linear range, and could be precisely quantified, while the signals of vitamin C and paracetamol were saturated using the 1 mm Max-Light cartridge cell. The 129 Infinity II HDR DAD signal approaches 4,35, which is within the linear UV range for the 129 Infinity II HDR DAD of approximately 6,7. Consequently, vitamin C, paracetamol, and caffeine could be quantified without problems by saturated signals. Figure 7 shows an enlargement of the 5-μL injection for the conventional and the 129 Infinity II HDR DAD signal. As expected, the 129 Infinity II HDR DAD signal allowed the evaluation of chlorphenamine and Impurities 1 to 4 simultaneously with the determination of the high-dose compounds. The limit of detection (LOD) with signal-to-noise (S/) = 3 of the compounds was evaluated for the 129 Infinity II DAD and the 129 Infinity II HDR DAD solution (Table 2). The LODs for the 129 Infinity II HDR DAD signal were approximately 3 to 5 % lower than the 129 Infinity II DAD signal. 4, 3, 2, 1, Impurity 1 Impurity 2 1 2 3 4 5 Chrlophenamine Figu re 6. Overlay of 5-μL injection of the Agilent 129 Infinity II DAD signal (red) signal and the Agilent 129 Infinity II HDR DAD signal (blue). 3 25 2 15 1 5 Impurity 1 Impurity 2 1 2 3 4 5 Figur e 7. Enlargement of 5-μL injection of the Agilent 129 Infinity II DAD signal (red) and the Agilent 129 Infinity II HDR DAD signal (blue). Table 2. Sensitivity. Agilent 129 Infinity II DAD LOD (pg on column) Chrlophenamine Agilent 129 Infinity II HDR DAD LOD (pg on column) Improvement in % 44.8 26.6 4 51.5 26.4 49 67.5 47.2 3 Chlorphenamine 118.5 84.4 29 5

Conclusion With the Agilent 129 Infinity II HDR DAD Impurity Analyzer Solution, determination of low-dose and high-dose drugs and additional impurities present in a fixed-dose combination drug was possible in one run. The complete determination of all compounds using the 129 Infinity II DAD with a 1-mm Max-Light cartridge cell required two injections with different injection volumes to avoid saturated signals for the high-dose drugs. In addition, lower detection limits were achieved with the 129 Infinity II HDR DAD Impurity Analyzer Solution compared to the Agilent 129 Infinity II DAD. The LOD for chlorphenamine was 3 % lower using the 129 Infinity II HDR DAD Impurity Analyzer Solution. 6

7

www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 215 Published in the USA, May 1, 215 5991-5743E