By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Similar documents
Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968

Pressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

SPIN-ON FILTER - LOW PRESSURE LINE

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

AIR FILTERS AND FILLER BREATHERS FA3 / FB1 / FB2 / FT series ACCESSORIES HYDRAULIC SYMBOL

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

In line high pressure filters. HF 725 series

D e s c r i p t i o n

In line high pressure filters. HF 735 series

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

THE IMPORTANCE OF AN EFFICIENT FILTRATION

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

D e s c r i p t i o n

Maxiflow Series Spin-on Filters Max. 360 I/min - 10 bar

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

In line high pressure filters. HF HF 761 series

Block mounting filter, for lateral flange-mounting

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Block mounting filter, for vertical flange-mounting

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

Line filter with filter element according to DIN 24550

Low Pressure Filters

HIGH PRESSURE FILTERS

FBK-FRCA. Return Line Filters Low Pressure Filters In-Line up to 10 bar. Mix&Match to Get What You Need

Fluid Cooling Industrial COLW Series

Filtration - Index FILTRATION

Oil Solutions. Phone Fax Low Pressure Filter Pi 150

Block mounting filter, for lateral flange-mounting

Tank top return-line filter Pi 5000

Suction Filter Pi 200

Low Pressure Filter/Suction Filter Pi 270

Duplex Pressure Filters

FPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need

Suction return line filter Pi 550

High Pressure Filter Pi 410

Medium Pressure Filter Pi 340

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

High Pressure Filter Pi 4000

Low / Medium Pressure Duplex Filter Inline mounting. Type : 40/160-LD/LDN. Filters. Accumulators. Hydraulic Symbol. Technical Data

Block mounting filter, lateral flange-mounting possible

Inline filter with filter element according to DIN 24550

THE IMPORTANCE OF AN EFFICIENT FILTRATION

MPF filters within this range are suitable for flow rates up to 750 l/min.

Low Pressure Filter Pi 1500

Replacement cartridge filter

Inline filter with filter element according to DIN 24550

High Pressure Filter Pi 420

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

Inline filter with filter element according to DIN Type 350LEN0040 to 1000; 350LE0130, 0150

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters

Stainless Steel Pressure Filters

Off-line Oil Filter Module Pi 8400

High-pressure inline filter, flangeable

High Pressure Filter Pi 4230

HIGH PRESSURE FILTERS

Duplex Filter Pi 3700

Duplex Filter Pi Features. Nominal pressure 200/250 bar (2850/3560 psi), nominal size up to 450

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

In-Line Filters. Section Index. High FPK

Low Pressure Filter Pi 2000

Low Pressure Filter Pi 1500

Block mounting filter, for sandwich plate mounting

12CS/50CS Series. Coreless Spin-on Filters

High Pressure Filter Pi 422

AGS/MPN Series. Medium Pressure Filters. Global Filtration Technology

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Low Pressure Filter Pi 200

Duplex Filter Pi Features. Nominal pressure 25/63 bar (360/900 psi), nominal size up to 450

Suction Filters S8-455 SE56-560

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Series RFL In-Line Filter

SPIN-ON FILTERS & ELEMENTS

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

Low Pressure Filter Pi 200

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

Inline filter with filter element according to DIN 24550

Transcription:

HYDRAULIC FILTRATION Spin-on, tank top return filters Technical Information Pressure: Max working 12 bar (175 psi) (acc. to NFPA T 3.10.17) Burst 20 bar (290 psi) (acc. to NFPA T 3.10.17) Connection Ports: 3/4 1 1/2 BSP Housing Materials: Head: Bowl: Seal: aluminium alloy steel Buna-N By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane Filter Media: Microglass fiber 4,5-7 - 12-27 µm (c) (acc. to ISO 16889) Element Cellulose 10-25 µm (c) (acc. to ISO 16889) Wire mesh 60-125 µm Differential collapse pressure: 4 bar (58 psi) (acc. to ISO 2941) Filtrec elements are tested also according to ISO 2942, ISO 23181 and ISO 3968 Working temperature: -25 C +120 C (-13 F +248 F) Common Fluid compatibility (acc. to ISO 2943): Full with HH-HL-HM-HV (acc. to ISO 6743/4). For use with other fluid applications please contact Filtrec Customer Service (info@filtrec.it). w w w. f i l t r e c. c o m

Ordering information MEDIA 000 no element G03 microglass fiber ß 4,5 µm (C) >1000 G06 microglass fiber ß 7 µm (C) >1000 G10 microglass fiber ß 12 µm (C) >1000 G25 microglass fiber ß 27 µm (C) >1000 C10 cellulose ß 10 µm (C) >2 C25 cellulose ß 25 µm (C) >2 T60 wire mesh 60 µm T125 wire mesh 125 µm NOMINAL SIZE Filter assembly FA-2 21 MEDIA C10 BM SEALS B CONNECTION B7 INDICATOR R13 Filter element A2 21 C10 BM SEALS B NBR CONNECTION B4 3/4 BSP (size 10-11) B7 1 1/2 BSP (size 20-21) INDICATOR 00 no indicator R6 visual pressure gauge 1,3 bar / 18,9 psi R7 pressure/vacuum gauge -1 5 bar / -14,5 72,5 psi R9 pressure gauge 0 4 bar / 0 58 psi R13 pressure switch SPDT 1,3 bar / 18,9 psi Preferential option 2

Overall dimensions L1 Ø F TANK MOUNTING PATTERN B1 D2 Ø M L R element removal D1 H2 indicator port H4 A H1 L A1 H3 A Nominal size CODE A B1 D1 D2 Ø F H1 H2 H3 H4 L L1 Ø M R WEIGHT ELEMENT H1 A1 FA-2-10 148 200 1,3 Kg A-2-10 148 3/4 BSP 99 96 40 45 7 15 25 90 50 M6 20 3/4 BSP FA-2-11 213 265 1,6 Kg A-2-11 213 FA-2-20 182 255 2,1 Kg A-2-20 182 1 1/2 BSP 141 128 65 70 9 20 36 122 70 M8 40 1 1/4 BSP FA-2-21 228 300 2,3 Kg A-2-21 228 3

Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 0,5 bar (8 psi). PRESSURE DROP THROUGH THE FILTER HOUSING Housing FA-2-10/11/20/21 The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT The Pressure Drop through the filter element is related both to the internal diameter of the filter element and to the filter media; this value is affected by the oil viscosity in a roughly proportional way: e.g. when the Dp value from the curve is 0,2 bar and a 46 cst oil is used, the corresponding value is 0,31 (=0,2 x 46/30) bar. Element A-2-10 Element A-2-10 Element A-2-11 Element A-2-11 Element A-2-20 Element A-2-20 4

Pressure drop diagrams Element A-2-21 Element A-2-21 Flow rate (gpm) Flow rate (gpm) p (bar) p (psi) p (bar) p (psi) PRESSURE DROP THROUGH THE BY-PASS VALVE The by-pass valve is a safety device to prevent element collapse in case of differential pressure peaks due to flow peaks, cold start conditions or when the clogged element is not replaced in a timely manner. By-pass FA-2-10/11/20/21 Flow rate (gpm) 4 60 FA2-1X FA2-2X 3 40 p (bar) 2 30 p (psi) 1 10 0 The above diagrams have been obtained at the FILTREC laboratory, according to the ISO 3968 specification, with mineral oil having 30 cst viscosity and 0,86 Kg/dm3 density. In case of discrepancy, please check contamination level, viscosity and features of the oil in use and the sampling points of the differential pressure. 5

Clogging indicator The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by the filter element. The filter element must be replaced when the indicator shows an alarm and before the Dp reaches the by-pass value setting. N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator alarm must be considered at normal working temperature only. The clogging indicator registers the pressure upstream the filter element: with the VISUAL indicator a value higher than 1,3 bar indicates the need of element replacement. with the ELECTRIC indicator an electrical switch is activated when the set value 1,3 bar is reached. VISUAL PRESSURE GAUGE SYMBOL CODE R6 SETTING 1,3 bar (18,9 psi) PRESSURE/ VACUUM GAUGE 30 Ø 40 1/8 BSP SYMBOL CODE R7 SCALE 0 1,4 bar (0 20 psi) green sector 1,4 5 bar (20 72,5 psi) red sector 12 Housing in black ABS material N.B. Multipurpose product: this gauge can also be used as vacuum gauge on suction filters. PRESSURE GAUGE SYMBOL CODE R9 SCALE 0 1 bar (0 14,5 psi) green sector 1 1,5 bar (14,5 22 psi) yellow sector 1,5 4 bar (22 58 psi) red sector Housing in black ABS material PRESSURE SWITCH SYMBOL 3 N.O. 1= COM. 2 N.C. 85 44 10 3 CODE R13 SETTING 1,3 bar (18,9 psi) SPDT CONTACTS 22,4 PRESSURE SWITCH 1,3 bar (18,9 psi) 25 1/8 BSP DC: 30 V 4 A inductive, 3 A resistive AC: 250 V 3 A inductive, 2 A resistive Protection: IP65, connector DIN43650 SPDT contacts N.B. it can be used as N.O. contacts or N.C. contacts switch only, simply connecting 1 and 3 or 1 and 2 only, respectively. Preferential option 6

User Tips FILTER CARTRIDGE with by-pass BOWL TIGHTENING TORQUE FA-2-xx 3/4 turn FILTER HEAD INDICATOR TIGHTENING TORQUE R4/R6/R7/R9/R13 30 Nm IDENTIFICATION LABEL FIXING HOLES IN FIXING HOLES INDICATOR OUT Installation Make sure that the filter flange is well secured on the tank lid through the fixing holes and that the hose is properly connected to the IN port; verify that the OUT port is clear (in this port an extension tube can be screwed, so that the outlet is below the oil level). After mounting verify that no tension is present on the filter. Make sure that enough space is available for cartridge (filter element) replacement and that the clogging indicator is in a easily viewable position. If an electrical indicator is used, make sure that it is properly wired. Never run the system without the cartridge fitted. We recommend the stocking of a spare FILTREC cartridge for timely replacement when required. Maintenance Before unscrewing the cartridge, ensure that the system is switched off and there is no residual pressure in the filter. Unscrew the cartridge by turning it anticlockwise. Verify the correct part number of the FILTREC replacement cartridge, particularly concerning the micron rating. Ensure that the mounting face is clean, lubricate the gasket on the replacement cartridge prior to assembly. Spin on new cartridge until it reaches the mounting face and tighten for ¾ turn. Operation Make sure that the filter works within the conditions of pressure, temperature and fluid compatibility given in the first page of this data sheet. The cartridge (filter element) must be replaced as soon as the clogging indicator signals at working temperature (in cold start conditions, oil temperature lower than 30 C, a false alarm can be given due to oil viscosity). If no clogging indicator is mounted, make sure that the cartridge is replaced according to instructions on the ca or to the system manufacturer s recommendations. PED Compliance FA-2 filters conform to PED 97/23/CE norm, article 3 section 3, and so they can be used with fluids of group 2 ( liquids with steam pressure < 0,5 bar at the maximum allowable temperature, article 3, section 1.1(b) sub-section II). WARNING Make sure that Personal Protective Equipment (PPE) is worn during installation and maintenance operation. Disposal of filter elements The used filter elements and the filter parts dirty of oil are classified as Dangerous waste material : they must be disposed according to the local laws by authorized Companies. 7

CT06-rev.02-04/17 w w w. f i l t r e c. c o m Technical information may change without notice