Installation, Operation, and Maintenance Instructions

Similar documents
Installation, Operation and Maintenance Manual

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Instructions

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

Part # Installation,Operation and Maintenance Instructions

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

VCD-23. Flange Options. Size Limitations

Installation, Operation and Maintenance Manual

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

VCD-23. Low Leakage CONTROL DAMPER

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

READ AND SAVE THESE INSTRUCTIONS

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Model VCD-20 3V CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

AMD-33 Air Measuring Station with VCD-33 Control Damper

Installation, Operation and Maintenance Manual

Supplemental Information Control Damper Panel & Jackshaft Arrangements Volume Control Damper Models: AC1, AC2, 515, 516, 525, 526, AC18, AC19

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

VCD-23 Low Leakage CONTROL DAMPER

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.


INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Model VCD-43 Extruded Airfoil Blade Control Damper

HYDRAULIC SPREADER. Max. Pressure: 10,000 PSI (700 BAR) Unit Weight: HS2000 = 4.8 LBS. (2.17 Kg) HS3000 = 22 LBS. (9.98 Kg)

Utility Distribution System

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Smoke Dampers. Installation Instructions

Model FSD-331 Combination Fire Smoke Dampers

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

HVAC Control & Balancing Dampers

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

Model FSD-212. Combination FIRE SMOKE DAMPERS

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

OPERATIONS MANUAL LEVER CHAIN HOIST

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

General Installation Instructions for Valves and Gates

HVAC Control & Balancing Dampers

Fire, Smoke, and Combination Fire Smoke Dampers

HCD-230 Industrial Control Damper

Introduction to Johnson Controls Dampers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

PC-125x Counter-Balanced Backdraft Damper

Laboratory Exhaust Systems

MODEL 8636 / 8636-LN / 8636-BAC SUREFLOW ROOM PRESSURE CONTROLLER

General Safety Information. Document KSFB and KSFD DANGER CAUTION WARNING! DBC DB3. Horizontal

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Installation, Operation and Maintenance Manual

Series HCD Airfoil Control Damper

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

RolsplicerTM. Maintenance Manual And Illustrated Parts List

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

Tube Axial Inline Fans

for Untempered - Make-Up Air Units

Portable Two-Stage Under Axle Jack Max. Capacity: First Stage: 27.5 Tons Second Stage: 11 Tons. Safety Precautions

Installation, Operation & Maintenance

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Hydraulic Hand Pallet Trucks

Installation, Operation and Maintenance Manual. RR & RC Flap Gates

Installation, Operation, and Maintenance Manual

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

MY-TE. OPERATION and MAINTENANCE. Winch and Hoist. Provided by: Model AC 36B OF MAX AC VOLT AC

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

MOTORIZED VOLUME DAMPER

Transcription:

Document Number 463384 VCD, FBH & FBV MODELS Vertical and Horizontal Mount Installation, Operation, and Maintenance Instructions This manual is the property of the owner, and is required for future maintenance. Please leave it with the owner when the job is complete. RECEIVING AND HANDLING Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Dampers must be kept dry and clean. Indoor storage and protection from dirt, dust and the weather is highly recommended. Do not store at temperatures in excess of 100 F (37ºC). SAFETY WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. Due to continuing research, Greenheck reserves the right to change specifications without notice.

Pre-Installation Guidelines The basic intent of a proper installation is to secure the volume control damper into the opening in such a manner as to prevent distortion and disruption of damper operation. The following items will aid in completing the damper installation in a timely and effective manner. 1) Check the schedules for proper damper locations within the building. Visually inspect the damper for damage. 2) Lift or handle damper using sleeve or frame. Do not lift damper using blades, linkage, actuators, or jackshafting. When handling multiple sections assemblies, use sufficient support to evenly lift at each section mullion (see drawing). Do not drag, step on, apply excessive bending, twisting, or racking. Spreader Bar 3) Do not install screws in damper frame that will interfere with unexposed blade Attachments linkage and prevent damper blades from opening and/or closing. 4) Damper must be installed into duct or opening square and free of twist or other misalignment. Damper must not be squeezed or stretched into duct or opening. Multi section dampers Out of square, racked, twisted or misaligned installations can cause excessive leakage and/or torque requirements to exceed damper/actuator design. 5) Damper and actuator must be kept clean, dry and protected from dirt, dust and other foreign materials prior to and after installation. Examples of such foreign materials include but are not limited to: a) Mortar dust b) Drywall dust c) Firesafing materials d) Wall texture e) Paint overspray 6) Damper should be sufficiently covered as to prevent overspray if wall texturing or spray painting will be performed within 5 feet (1.50m) of the damper. Excessive dirt or foreign material deposits on damper can cause excessive leakage and/or torque requirements to exceed damper/actuator design. 7) ACCESS: Suitable access (actuators maintenance, etc.) must be provided for damper inspection and servicing. Where it is not possible to achieve sufficient size access, it will be necessary to install a removable section of duct. Electrical Guidelines Electrical and/or pneumatic connections to damper actuators should be made in accordance with wiring and piping diagrams developed in compliance with applicable codes, ordinances and regulations. SAFETY CAUTION! Verify power requirements before wiring actuator. Greenheck is not responsible for any damage to, or failure of the unit caused by incorrect field wiring. SAFETY DANGER! Electrical input may be needed for this equipment. This work should be performed by a qualified electrician. 2

Installation - Failure to follow instructions will void all warranties 1. Duct opening or opening square should measure 1/4 inch (6mm) larger than damper dimension and should be straight and level. A B C E D F AF = BE AB = CD Do not twist or bow. Mount damper plumb in the opening. 2. If more than two sections wide, unit ships as a multiple section assembly and a single section together. The single section is joined to the side of the multiple section where the jackshaft extends past the frame 4 inches (see Figure 1 & 2). 3. A damper assembly is not restricted to a maximum number of sections, but must not exceed the section sizes and overall sizes shown at the right. 4. The damper sections must be attached together with #10 x 3 4in.(19mm) max. sheet metal screws, 1/4 in. (6mm) diameter nuts and bolts, tack or spot welds, or 3 16 in. (4mm) diameter steel pop rivets. Attachments must be spaced a maximum of 6 in. (152mm) on centers and a maximum of 2 in. (50mm) from corners. Attachments must be made on front face and back face (air entering and air exiting side) of damper sections. 5. Two section high dampers require reinforcement using a 14 gauge (2mm), 5 in. (127mm) wide mullion or two individually sleeved units stacked vertically. When using two individually sleeved units, the sleeve acts as the mullion, therefore no mullion is required (Mullions are not provided by Greenheck). Damper Model VCD-15, VCD-18 VCD-20, VCD-23 VCD-33, VCD-34, VCD- 40, VCD-42, VCD-43 VCD-20V, VCD-23V VCD-33V, VCD-42V, VCD-43V FBH-43 FBV-43 Maximum Single Section Size W x H in. (mm) 48 x 60 (1219 x 1524) 48 x 74 (1219 x 1880) 60 x 74 74 x 48 (1879 x 1219) 74 x 60 (1879 x 1524) Face: 60 x 74 Bypass: 60 x 74 Face: 60 x 74 Bypass: 60 x 74 Maximum Overall Size for Multi- Section Dampers 84 in. W x 60 in. H (2133mm x 1524mm) Unlimited Unlimited NA NA Face: 96 x 74 (2438 x 1880) Face: 96 x 74 (2438 x 1880) Bypass: 96 x 74 (2438 x 1880) 3

Installation (continued) 6.000 O.C. MAX. Figure 1 Figure 2 6. When the height of a Face & Bypass vertical style (FBV) is greater than 84 in. (2134mm), the damper sections are shipped separate and field assembly is required. Before fastening damper sections together, the non-actuated damper section will need to be flipped upside down so that the linkage is on the same side as the actuated damper. After damper sections are fastened together, attach interconnecting angle as shown in Figure 3. (Interconnecting angle is shipped with actuated damper section.) Figure 3

Installation (continued) 7. If no holes are present in frame, drill 1/4 inch (6mm) diameter holes at 6 inch (52mm) centers and fasten frames together with 1/4 inch (6mm) #20 (.03mm) bolts and nuts (see Figure 1 & 2). 8. Use shims between damper frame and duct opening or opening space to prevent distortion of frame by fasteners holding it in place. Brace at every horizontal mullion and vertically brace at every 8 feet (2.4m) of damper width for strength. Dampers in high velocity (2000 fpm [610m per second]) may require more bracing. Note: Greenheck dampers are specifically designed and engineered for structural integrity based on model and conditions. Attachment, framing, mating flanges, and anchoring of damper assemblies into openings, ductwork, or walls is the responsibility of the installer. Design calculations for these retaining and supporting members should be determined by field engineers for that particular installation. 9. If damper actuator is to be mounted out of the airstream, the extension pin should extend approximately 6 inches (152mm) beyond the frame. On jackshafted units, the jackshaft should extend through the jackshaft bearing assembly and approximately, 6 inches (152mm) beyond the frame. 10. Individual damper sections, as well as entire multiple section assemblies must be completely square and free from racking, twisting, or bending. Measure diagonally from upper corners to opposite lower corners of each section. 11. Damper blades, axles, and linkage must operate without binding. Before system operation, cycle dampers after installation to assure proper operation. On multiple section assemblies, all sections should open and close simultaneously. Note: When you have a vertical damper installation, blades must be horizontal. When blades need to be vertical, you need a vertical blade damper (example: VCD-23V). These dampers are built so they don't crush the jamb seal. Damper Maintenance Greenheck's dampers are designed to be trouble free and hassle free under normal operation. Dampers are to be installed square and straight so as to prevent binding during operation. The following annual damper maintenance suggestions will help to insure proper damper operation and increase the life expectancy of the damper. Foreign Matter Moving Parts Closure Operation Over the course of time, dirt and grime may collect on damper surfaces. The damper surfaces should be cleaned to prevent hindrance to airflow. Make sure that parts such as linkage, bearings, blades, etc. that are intended to move freely, can do so. Lubricating these components can prevent possible rusting and unnecessary friction increase. Use only a moli-spray oil or similar graphite based oil as regular lubricating oil will attract dirt. Bearings. Synthetic, oil impregnated, and ball bearings (without grease fittings) do not require lubrication. Ball bearings with grease fittings require only minimal grease. Remove foreign materials that may be interfering with blade closure or effective sealing of the blades with each other or with the frame. While operating the damper through its full cycle, check to see that the blades open and close properly. If there is a problem, check for loose linkage, especially at the actuator. Tighten the linkage where required.

Damper Trouble Shooting The following is a cause and correction list for common concerns with the dampers. Symptom Possible Cause Corrective Action Damper does not fully open and/or fully close Actuator runs hot or makes a humming noise Frame is 'racked' causing blades to bind on jamb seals Actuator linkage loose Defective motor Screws in damper linkage Actuator linkage hitting wall or floor Contaminants on damper Actuator type is MP-3754 or MP-3756 (stall type actuator) Actuator prohibited from reaching end of stroke Adjust frame such that it is square and plumb Close damper, disconnect power, adjust and tighten linkage Replace Locate screws and remove Damper installed too far into wall. Move out to line designated on damper label Clean with a non oil-based solvent (see Damper Maintenance) None required since this normal for stall type actuators Disconnect linkage from jackshaft, open damper, power actuator to end of spring, tighten linkage. Verify amp draw. Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Phone: (715) 359-6171 Fax: (715) 355-2399 E-mail: gfcinfo@greenheck.com Website: www.greenheck.com 463384 VCD Series Rev. 9, October 2012 Copyright 2012 Greenheck Fan Corporation 6