CBS 212/CBS 212A CURRENT BOOST SYSTEM

Similar documents
INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

DGC-2020 DIGITAL GENSET CONTROLLER

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

MX431 Generator Automatic Voltage Regulator Operation Manual

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

PD-Series Ground Fault Circuit Protection

INSTRUCTION MANUAL FOR

PDR circuit breaker - Ground fault Datasheet

DGC-2020 DIGITAL GENSET CONTROLLER

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

MODEL 422 Submersible Pump Controller

DIGITAL GENSET CONTROLLER

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Transfer switch GTEC open or delayed transition

KD LV Motor Protection Relay

PM300E Voltage Regulator Instruction Manual

Instruction Manual. Installation Operation Maintenance. KCR 760 Voltage Regulator

EA07. Generator Automatic Voltage Regulator Operation Manual

PB-Series. GFCI/ELCI & Panel Seal

TECHNICAL DATA SHEET AIRCRAFT GROUND POWER UNIT MODEL NO. B809D-1

AUTO CHARGE AMPS DELUXE AUTOMATIC BATTERY CHARGER. Section 1: Single Battery Systems

IVT-1260 & IVT Generator Auxiliary Excitation Booster Operation Manual. (Patent Pending)

Transfer switch OTEC open or delayed transition

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

General Purpose Buck - Boost Wiring Diagrams... 86

Technical Information

Table of Contents. For latest version, visit:

CONTENTS 1. 1 Power Units Overview Applications Models Power Units... 3

60 Series Engine Controls

Diesel generator set C17D5T series

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Solid-State Relays. Solid-State Relays. Features. Description. Overview

RVS-DX Digital Reduced Voltage Motor Starter

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

Solid-State Relays. Solid-State Relays. Features. Description. Overview

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

Operators Type /24 DC and 120V-60Hz AC

AP/UP, AP/MIL Series Magnetic Circuit Protectors

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCTS: POWER SUPPLY

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

B CW POWER RELAY

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

POWR-GARD Relay Testing Equipment PGT-0400 Series Ground-Fault Relay Test Unit PGT Ground-Fault Relay Test Unit

GTEC Transfer switch open transition

OTEC Transfer switch open transition

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

RVS-DN Digital Reduced Voltage Motor Starter

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Description 1/8-7.5HP

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

C E R T I F I C A T E O F C O M P L I A N C E

XR500B Universal Voltage Regulator

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

GTEC Transfer switch Open transition

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

COMMERCIAL HANDBOOK 2013 EDITION MATANUSKA ELECTRIC ASSOCIATION, INC. PALMER, ALASKA

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

The Power of Reliability INSTRUCTION MANUAL

SURE TRIP RETRO KITS

XQ2000 SOUND ATTENUATED POWER MODULE

INVERTER FOR DC CRANE CABIN AIR CONDITIONING UNIT 3KW VERSION

Renewable Energy Product & Parts Catalog

INSTRUCTION MANUAL CAUTION

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

MCD 200 Series Soft Starters

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Specifications. Minimum Build Up Volts 3.5vac. Voltage Regulator

RP-4000 Reserve Power Control

FROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding

MDR POWER RELAYS MERCURY DISPLACEMENT TUBE DESIGN FEATURES

VAC Electrical Requirements. VDC Electrical Requirements

GP/GPA GROUND FAULT PROTECTION

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER

Diesel Generator Set S3.8 Series Engine

20 kw DIESEL GENERATOR

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

BATTERY CHARGERS.

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Moulded case circuit breakers

Transcription:

CURRENT BOOST SYSTEM APPLICATION AND FEATURES this page APPLICATION: The CBS 212 and CBS 212A Current Boost Systems are solid-state excitation support devices designed to supply 20 Amps for 10 seconds to the field. These units, combined with their respective current transformers and SSR voltage regulator, provide excitation support to the generator field during generator short circuit conditions and overloads, such as motor starting. Two styles are available; the CBS 212 features a reduced footprint and the CBS 212A has a low profile. The varying package design allows for meeting specific customer requirements. DESCRIPTION AND SPECIFICATIONS page 2 ORDERING page 3 DEVICE FEATURES: Instantaneous response to short circuits. Up to 20 A field boost power for 10 seconds. Activated when generator voltage drops too low to maintain field current. For 50 or 60 Hertz brushless generators. Covers a wide range of generator applications. Adjustable forcing voltage limit. Available from stock. EXTERNAL CONNECTIONS Terminals and Interconnections page 4 OUTLINE DRAWINGS Current Transformers and CBS Modules pages 5 thru 8 INSTRUCTION MANUAL Reference Publication Number 9 2650 00 990 (CBS 212) 9 2707 00 990 (CBS 212A) P.O.BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE 618-654-2341 FAX 618-654-2351 SQA-2 11-93

DESCRIPTION: Each version of the Current Boost System consists of a current boost module and two separately supplied current transformers. These systems provide supplemental excitation, which allows the field to receive full forcing during generator overload and short circuit conditions. The Current Boost Systems allow three wire and four wire generators to provide sustaining current during single phase and multiple phase line-to-line faults. The CBS also permits four wire generators to support phase A and B line-to-neutral faults. Phase C line-toneutral faults also have fault sustaining capabilities when regulator input power is taken from the unshorted phases A and B. The CBS 212 and CBS 212A sense generator output voltage. When the voltage drops below the operation point selected on the OPERATION POINT adjustment (due to a short circuit or motor start) the current boost module will extinguish the OPERA- TION POINT indicator and will remove the SCR short from the CT. The module then provides current boost to the generator exciter until the voltage returns to a level just above the operation point, and illuminates the OPERATION POINT indicator. SPECIFICATIONS: Limit Adjust... 50% to 100% of selected output; (50/100/220 Vdc for CBS 212, 60/120/220 Vdc for CBS 212A) Operation Point Adjustment... 70 to 131 Vac for 120 Volt nominal, 140 to 262 Vac for 240 Volt nominal Dropout Ratio... Dropout @ 5v above pickup point for 120 Volt nominal, dropout @ 10v above pickup point for 240 Volt nominal Power Dissipation... Less than 50 watts at continuous rating Storage Temperature Range... -85 F (-65 C) to +185 F (+85 C) Operating Temperature Range... -40 F (-40 C) to +140 F (+60 C) Shock...Withstand up to 15 G s in each of three mutually perpendicular planes Vibration... Withstand 5 to 26 Hz @ 1.2 G s; 27 to 52 Hz @ 0.036... double amplitude; 53 to 260 Hz @ 5.0 G s Weight Current Boost Module (CBS 212)... 12.5 lbs. (5.68 Kg) (CBS 212A)... 15 lbs. (6.8 Kg) BE 25925 001... 84 lbs. (38.2 Kg) BE 25926 001... 78 lbs. (35.5 Kg) BE 25927 001... 66 lbs. (30.0 Kg) BE 25928 001... 122 lbs. (55.5 Kg) BE 25929 001... 73 lbs. (33.2 Kg) BE 25930 001... 50 lbs. (22.7 Kg) CT Secondary Turn Ratio BE 25925 001... 1:8 BE 25926 001... 1:17 BE 25927 001... 1:34 BE 25928 001... 1:69 BE 25929 001... 1:138 BE 25930 001... 1:277 2

SAMPLE SPECIFICATION: A current boost system shall be provided with the Basler Electric SSR model of voltage regulator. This unit shall sustain exciter field current during severe generator output overloads or short circuit. The current boost system shall sense generator line voltage and, upon a drop in voltage, become enabled. The current boost system shall receive power by two CTs, installed in the phases of the generator output. The current boost system shall be Basler Electric Company model CBS 212 or CBS 212A, with current transformers selected based on Basler recommendation and generator performance data. HOW TO ORDER: Current Transformer For current transformer selection, select the current transformer from the table below that matches the amount of system 3 phase short circuit line current. Excitation Module For reduced footprint requirements, order CBS 212; see Figure 2. For low profile requirements, order CBS 212A; see Figure 3. This unit gives mounting dimensions similar to the SSR voltage regulator. Two current transformers are required for use with each CBS unit. Pictured above: BE 25930-001. There are six standard CT designs available for the current boost modules. Select the CTs from the table below. For 3ø Short Circuit Line Current: Use Two (2) CTs: Turns Ratio: 125-250 Aac 250-500 Aac 500-1000 Aac 1000-2000 Aac 2000-4000 Aac 4000-8000 Aac BE 25925 001 BE 25926 001 BE 25927 001 BE 25928 001 BE 25929 001 BE 25930 001 1:8 1:17 1:34 1:69 1:138 1:277 TABLE 1. 3

FIGURE 1. TYPICAL INTERCONNECTION DIAGRAM. 4

NOTE: Dimensions in parentheses are in millimeters. FIGURE 2. OUTLINE DRAWING. NOTE: Dimensions in parentheses are in millimeters. FIGURE 3. OUTLINE DRAWING. 5

FIGURE 4. OUTLINE DRAWING BE 25925-001. FIGURE 5. OUTLINE DRAWING BE 25926-001. 6

FIGURE 6. OUTLINE DRAWING BE 25927-001. FIGURE 7. OUTLINE DRAWING BE 25928-001. 7

FIGURE 8. OUTLINE DRAWING BE 25929-001. FIGURE 9. OUTLINE DRAWING BE 25930-001. 8 ROUTE 143, BOX 269, HIGHLAND, ILLINOIS U.S.A. 62249 P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE PHONE 618-654-2341 FAX 618-654-2351 PHONE (33-3-88) 87-1010 FAX (33-3-88) 87-0808 http://www.basler.com, info@basler.com