Double function Ball Valve with automatic safety lock Type , patented

Similar documents
LUMOTAST 25 selector switch 1-28 LUMOTAST 25 selector switch, Click quick-assembly feature 1-29 LUMOTAST 25 selector switch, ring nut fixing 1-29

QUICK UNLOCKING AND REARMING LOCKS

Double motor belt grinding machine

DOOR CLOSERS 601/T SERIES DOOR CLOSERS 601/T SERIES

Emergency lighting units LED series

A02 SERIES ILLUMINATED OR NON-ILLUMINATED PUSHBUTTON SWITCHES Panel cut-out Ø22 or 29.5 x 21.5

Specifications. Fluid Operating pressure range Proof pressure Operating temperature range Filtration Element proof pressure differential

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

ZB0050 / ZB0051 ZB0070 / ZB0071

Escape Door. For all kinds of buildings, particularly Hospitals, Hotels, Offices and Institutional Buildings

BMW X5 Customer Service Guide. 6V BMW X5 (5F60E99) Customer Service Guide

LUMOTAST FK. General data. Content

MAKING MODERN LIVING POSSIBLE. Pressure switch BCP. Technical brochure

4500/4600/4300 SERIES KEY IN LEVER LOCKSETS. ainsborough now offers a broad selection of key in lever lockset

Beep&Park kit fitting and operating instructions

Deluge Valves. Model 68 DE\ HRV-MR. Hydraulically Actuated, Anti-Columning, Manual-Reset Deluge Valve. Dorot Fire Protection Division

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

Hydraulic Valves Needle Valves

DA/SR. Pneumatic Rotary Actuators FEATURES VALBIA ISO 9001 CERTIFIED

WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR

The Antipanic Compliance to the standard EN1125

BMW i. Freude am Fahren. Wallbox Pure

Emergency lighting units EM powerled

Electronic Wall Lamps

General_technical_data Series

Lt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red

Accessories and spare parts

NAF-Trunnball ball valves

ANT. Materials. Features. Miniature Toggle

Mottura lifetime patented MM key profile. Controlled breaking shear in the event of break-in.

KPB 25 W M R &30 CONTROL COMPONENTS. Push Button Switches. KPB, KSL, KPL and KBL series are designed for a wide range applications.

Safety Shut-Off Valve HON 711 S2

RAFIX 22 QR. General data. Content

A01 SERIES PUSHBUTTON SWITCHES, ILLUMINATED OR NON-ILLUMINATED Panel cut-out.630" (16mm)

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Note: the numbers in parenthesis refer to the components in the exploded view of page 3 for UT-0 thru UT-6.5 and page 4 for UT-7 and UT-8.

SAFETY

Installation Guide. RunLock. NISSAN Navara D40. Art.Nr. B

Service/Installation Manual Full Wall Slide Systems CONTENTS. 82-S0379 Rev 3. Page. Before you operate the slide system 2

Pneumatic Rotary Actuators

Heating Cost Allocation Valve with local acquisition of the flow temperature

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Needle and Butterfly Valves

Emergency lighting units EM powerled

ACM 40 35T Technical Description VDG /04/17. For any inquiry related to this. product please contact:

2 CHANNEL MULTI-PURPOSE RECEIVER

Wireless Access Controlled Door Solution

Datasheet. Electrical Switching / Locking

Emergency lighting units EM powerled

Control Buttons / Switches for Panel Mounting Series 8003

Quarter-turn locks, compression latches

The best in security is at your fingertips

Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

INSTRUCTION MANUAL CAT Bio-Pump Plus

PCB plug-in connectors

Configurations: s.64. s.31. s.74 3 way. Flow: Mini 2 way Direct mount. Flow: Full. Flow: Standard 3 way. ISO 5211 F03 Flange

Three-port slipper valves PN10, female-threaded

502 VALVE WITH UM1.5 ELECTRIC ACTUATOR. Model/Ref:

Switches. Common Used Terminology:

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

Sealed Enclosures. Contact Blocks. Multiple Actuators

SFS-UFS Single Foot Switches

I&M UT Series (2003 Design)

Gunnebo Lifting Offshore programme - accessories. High consistent quality generates long durability and safety

Emergency lighting units EM powerled

NAILOR COMMERCIAL REGISTERS, GRILLES AND DIFFUSERS

Catalogue no. 80, valid as of January varimed Furniture for OR theatres and outpatient departments

Conflicts Note: Toyota Tacoma 2015 LED Bed Lights Preparation. Part Number: Accessory Code: BU1000

Standard Port, Uni-Body Flanged Ball Valves

Operating manual GA 250AL GA 400AL. Edition 07 / Automatic Airless Spraygun. II 2GX (Atex 95)

Industrial controls. Section G

brochure PN

Valve Lockouts. Valve lockouts are available to suit all types of valve including ball valve, gate valve, globe valve and plug valve.

AV series Anti-vandal and security pushbutton switches

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

A1-A01-A02-A03 series

Service - Safety Manual

XVS1300A Midnight Star Accessories Overview

Deluge Pressure Reducing Valves. Model 68 DE\ RCL\ PR. Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve

OPERATING INSTRUCTIONS. Operating Instructions

DatA sheet. D-2011/05/ Date: 02/2013. Type TK10 CNG. CNG Fuelling Nozzle. for cars FUTURE. TECHNOLOGY. TODAY.

OPERATION INSTRUCTIONS

HA6 INSTALL GUIDE BLADE-AL(DL)-HA6-EN INSTALL GUIDE ALL IN ONE HONDA/ACURA INSTALL TYPE SELECTION. Automotive Data Solutions Inc.

UT Series. Pneumatic Actuators. UT-**-DA Series UT-**-SR Series. A full range of double acting and spring return actuators designed

Material: Hinge Parts: zinc die, matt chrome plated, or zinc die, matt black. Pin: stainless steel Nut plate: steel, zinc plated

SECTION J CONTENTS OPTIONAL CONFIGURATIONS DESCRIPTION

Lecture #8. Design for Manufacturing DfM. ME 2110: Creative Decisions and Design

Product Range Comprehensive range of cylinders in various profiles and sizes, with the ability to integrate padlocks

UNION KESO CYLINDERS. An ASSA ABLOY Group brand ASSA ABLOY

The Fischertechnik ACEs (Robo Starter Model kit)

70.03 Victaulic Vortex TM

STS INSTALLATION MANUAL MECHANICAL SWITCH

PANEL ACCESS - CONTENT

INDUSTRIAL CONTROLS. Description. Products & features. Specifications. Illuminated or non-illuminated pushbutton switches.

USER INSTRUCTIONS STRIKER LED USER INSTRUCTIONS

ELECTRICAL SPECIFICATIONS

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

mm Solenoid Valves. 2.6 page 131

Transcription:

Double function Ball Valve with automatic safety lock Type 6584.04, patented blue aluminum handle fire varnished and 2 keys for each valve for one or more codes 1 Master Key allowing the opening of all codes with manual lock in closing and/or opening position with automatic lock only in closing position with manual lock in closing and / or opening position or with automatic lock on closing position if the valve with manual lock is locked by means of the relevant key it can be operated as an open / closed valve - offering in this way also an arrearage function manual lock in closing and / or opening position or with automatic lock only in closing position 6584.04......050...075...100 A 80 80 80 H 69 73 77 L 58,4 68,5 82 15 16,3 19,1 ø P 15 20 25 KG 0,490 0,680 0,970 proof if locking device is in position take out the key and close the valve, the locking device closes automatically with a snap reset of the safty device and take it out the safety device is ready, the valve can be used again 1

Type 6584.77, patented red aluminum handle fire varnished and 2 keys for each valve, for one or more codes blocked only in closed position 1 Master Key, nickel plated, allowing the opening of all codes this key should be kept by the utility's staff taking care of customers with overdue payments 1¼" 1½" 2" 6584.77......050...075...100...125...150...200 A 80 80 80 140 140 140 H 69 73 77 91 98 106 L 58,4 68,5 82 93 105 125 15 16,3 19,1 21,4 21,4 25,7 ø P 15 20 25 32 40 50 KG 0,490 0,680 0,970 1,530 2,100 3,140 in closing position lock the valve put the key in the lock, turn it from to and take it out, the valve is blocked to unlock the valve, put the key to, turn it to and take it out un if the key is taken out from position the locking device is deactivated, the valve can be operated as a common Ball Valve 2

Type 6584.41, patented red aluminum handle fire varnished and 2 keys for each valve, for one or more codes 1 Master Key, nickel plated, allowing the opening of all codes this key should be kept by the utility's staff taking care of customers with overdue payments blocked in open and closed position 6584.41......050...075...100 A 80 80 80 H 69 73 77 L 58,4 68,5 82 15 16,3 19,1 ø P 15 20 25 KG 0,490 0,680 0,970 in opening position unlock the valve put key in the lock, turn it from to and take it out the valve is blocked. to unlock the valve, put the key to, turn it to and take it out un if the key is taken out from position, the locking device is deactivated, the valve can be operated as a common Ball Valve 3

Type 6584.48, patented for gas distribution systems with patented double function (safety and anti arrearage) anti-effraction (DFA) and cannot be disassembled by an unauthorised person without demaging acc. to safety standard UNI 9036:2001 (4.1.1, 5.3.1.1, 5.3.2), preventing the operation by third or unauthorised persons acc. to PED (Pressure Equipment Directive) and CE marking where required tested with air at 5 bar and water at 24 bar, EN331:1998 working pressure max. 5 bar working temperature -20 C to + 60 C yellow aluminum handle fire varnished delivered with 35 different codes and 2 user's keys for each valve for one or more codes to identify the number of the key easily, this number is marked both on the latch of the valve and the key itself manual lock in closing and / or opening position or with automatic lock only in closing position Type 6584.48 6584.48......050...075...100 A 80,0 80,0 80,0 H 69,0 73,0 77,0 L 58,4 68,5 82,0 15,0 16,3 19,1 ø P 15,0 20,0 25,0 Kg 0,485 0,685 0,970 1 Master Key with green plastic cover allowing the opening of all codes 1 Master/Universal Key with pink plastic cover allowing the opening of all codes of the key and to put in/out the anti-arrearage device, to be kept by the utility's staff taking care of customer with overdue payments proof if locking device is in position take out the key and close the valve the locking device closes automatically with a snap reset of the safety device and take it out, the safety device is ready, the valve can be operated again 4

User's and Master Key 6584.11.27 Master Key for the Ball Valve with safety and arrearage lock and codes from 651 to 685. proof that the locking device is at, take out the key and close the valve, the locking device snaps shut reset of the safety device and take it out, the safety device is working and the valve can be operated again an arrow on the key indicates the position of the lock Arrearage and Master Key 6584.11.26 Arrearage and Master Key for the ball valve with safety and arrearage lock and codes from 651 to 685 proof if locking device is in position, then close the valve, the locking device closes with a snap and take it out, the valve is blocked in the anti-effraction position, the locking latch is blocked and cannot be turned back three coloured spots indicate the position of the key/lock the safety system is activated open position anti-arrearage position 5