SERIES: VBT1-SMT DESCRIPTION: DC-DC CONVERTER date 11/01/2012 page 1 of FEATURES 1 W isolated industry standard 8 pin SMT package dual unregulated s 1,000 V isolation short circuit protection UL safety approvals (some models) wide temperature (-40~8 C) efficiency up to 79 RoHS MODEL input voltage voltage current power ripple and noise 1 efficiency typ () range () () min (ma) (ma) (W) (mvp-p) typ () VBT1-S3.3-S3.3-SMT 3.3 3.0~3.63 3.3 30 303 1 7 73 VBT1-S3.3-S-SMT 3.3 3.0~3.63 20 200 1 7 74 VBT1-S-S3.3-SMT 4.~. 3.3 30 303 1 7 72 VBT1-S-S-SMT 4.~. 20 200 1 7 7 VBT1-S-S9-SMT 4.~. 9 12 111 1 7 76 VBT1-S-S12-SMT 4.~. 12 9 84 1 7 79 VBT1-S-S-SMT 4.~. 7 67 1 7 78 VBT1-S-S24-SMT 4.~. 24 4 42 1 7 78 VBT1-S12-S3.3-SMT 12.8~13.2 3.3 30 303 1 7 7 VBT1-S12-S-SMT 12.8~13.2 20 200 1 7 69 VBT1-S12-S9-SMT 12.8~13.2 9 12 111 1 7 73 VBT1-S12-S12-SMT 12.8~13.2 12 9 84 1 7 73 VBT1-S12-S-SMT 12.8~13.2 7 67 1 7 74 VBT1-S12-S24-SMT 12.8~13.2 24 4 42 1 7 79 VBT1-S-S-SMT 13.~16. 20 200 1 7 74 VBT1-S-S-SMT 13.~16. 7 67 1 7 79 VBT1-S24-S3.3-SMT 24 21.6~26.4 3.3 30 300 1 7 69 VBT1-S24-S-SMT 24 21.6~26.4 20 200 1 7 70 VBT1-S24-S9-SMT 24 21.6~26.4 9 11 1 1 7 72 VBT1-S24-S12-SMT 24 21.6~26.4 12 8 83 1 7 7 VBT1-S24-S-SMT 24 21.6~26.4 7 67 1 7 76 VBT1-S24-S24-SMT 24 21.6~26.4 24 4 42 1 7 77 Notes: 1. ripple and noise are measured at 20 MHz BW PART NUMBER KEY VBXT1 - SXX - SXX -SMT - X Base Number X indicates ALT PIN configuration, see page 3 Input Voltage Output Voltage Packaging Style Package Options "blank" = standard TR = Tape & Reel
CUI Inc SERIES: VBT1-SMT DESCRIPTION: DC-DC CONVERTER date 11/01/2012 page 2 of INPUT operating input voltage OUTPUT 3.3 V model V model 12 V model V model 24 V model line regulation load regulation voltage accuracy switching frequency for change of 1, 3.3 V model for change of 1, all other models measured from load to full load 3.3 V model V model 9 V model 12 V model V model 24 V model see derating curves 0 load, and 12 V input 0 load, 24 V input 0 load, all other models 3.0 4..8 13. 21.6 3.3 12 24 12.8 8.3 6.8 6.3 6.0 3.63. 13.2 16. 26.4 1. 1.2 20 0 00 0 00 temperature coefficient ±0.03 / C PROTECTIONS short circuit protection 1 s SAFETY AND COMPLIANCE isolation voltage for 1 minute at 1 ma. 1,000 isolation resistance at 00 1,000 MΩ safety approvals 1 UL 6090-1 (E222736) MTBF 3,00,000 hours RoHS compliant Notes: yes 1. VBT1-S3.3-S9/12//24, VBT1-S-S3.3 and 24, VBT1-S12-S3.3 and S24, VBT1-S (all), and VBT1-S24 (all) models UL 6090-1 pending ENVIRONMENTAL operating temperature -40 8 C storage temperature - 12 C storage humidity non-condensing 9 temperature rise at full load 2 C lead temperature 1. mm from case for seconds 300 C
CUI Inc SERIES: VBT1-SMT DESCRIPTION: DC-DC CONVERTER date 11/01/2012 page 3 of DERATING CURVES 1. power vs. ambient temperature 2. voltage vs. current + Load () 0 80 60 40 20 Output Voltate () + Nominal Voltage +2. -2. -7. -40-20 0 20 40 60 8 120 Ambient Temperature ( C) 0 0 Output Current () MECHANICAL dimensions 0.00 x 0.441 x 0.246 (12.70 x 11.20 x 6.2 mm) inch case material plastic (UL94-V0) weight 1.41 g MECHANICAL DRAWING units: mm [inches] tolerance: ±0. [±0.006] pin section tolerance: ±0. mm [±0.004] (Side View) 6.2 [0.246] 6.00 [0.236] 0.2 [0.0] 0.60 [0.024] VBT1 VBXT1 12.70 [0.00]. [0.398] 8 7 6 2.4 [0.0] 8 2.4 [0.0] 1 2 3 4 2. [0.083] 1 2 4 7.0 [0.29] 8 7 6 (Top View) 11.20 [0.441] 2.4 [0.0] 1.00 [0.039] 1 2 3 4 PIN CONNECTIONS PIN FUNCTION ALT FUNCTION 1 GND GND A 2 + + 0.2 [0.0] 8.0 [0.33] 4 0 V 0 V +Vo +Vo 3,6,7 NC No PIN A 0.2 [0.0] 8 NC NC 1.3 [0.03]
CUI Inc SERIES: VBT1-SMT DESCRIPTION: DC-DC CONVERTER date 11/01/2012 page 4 of APPLICATION NOTES 1. Requirement on Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the minimum load is not less than load. If the actual load is less than the specified minimum load, the ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual power is very small, please add an appropriate resistor as extra loading. 2. Overload Protection Under normal operating conditions, the circuit of these products has no protection against over-current and short-circuits. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. 3. Filtering In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC end and input end to reduce the noise and ripple. However, the capacitance of the filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an LC filtering network may be connected to the input and ends of the DC/DC converter, which may produce a more significant filtering effect. It should also be noted that the inductance and the frequency of the LC filtering network should be staggered with the DC/DC frequency to avoid mutual interference (Figure 1). +Vo Figure 1 Cin DC DC Cout GND 0V 4. Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or end in series (Figure 2). Figure 2 GND REG DC DC REG +Vo 0V. External Capacitor Table It is not recommended to connect any external capacitor in the application field with less than 0. W. () Cout (μf) Vout () Cout (μf) Table 1 3.3/ 4.7 3.3/ 12 2.2 9 4.7 2.2 12 2.2 24 0.47 1 -- -- 24 0.47
CUI Inc SERIES: VBT1-SMT DESCRIPTION: DC-DC CONVERTER date 11/01/2012 page of REVISION HISTORY rev. description date 1.0 initial release 01/14/2011 1.01 new template applied 04/11/2012 1.02 V-Infinity branding removed 09/0/2012 1.03 added TR package option 11/01/2012 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 2000 SW 112th Ave. Tualatin, OR 97062 800.27.4899 Fax 03.612.2383 techsupport@ CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.