MX Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable

Similar documents
C Power Connection Kit

Wiring Assembly Instructions Section 5 P/N CASS P/N 1899AS RG316 P/N CASS P/N 1899AS RG316

RG6 TLC F Hands-On. Materials Needed RG6 regular/dual coax cable Adjustable prep tool (stripper) (45-526) RG6 F TLC connector (85-168)

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

VITALink Taped Splice Pigtail Crimp

Handyman Motor Capacitor Meter PART NO

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

QT-III Cold Shrink Silicone Rubber

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

THE safety accessory of the 21 st Century.

Bel Stewart Connector

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

MX2040, DYNAMIC SIGNAL CHECKER Instruction Manual

CASS Interface System Parts Section 1

1 COPPERHEAD 3D PRINTER ASSEMBLY GUIDE WELCOME

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

Installation Instructions

1 GENERAL INFORMATION

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

Installation of Raxiom Switchback Turn Signal Conversion Kit w/resistors

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Bob's Shop Notes: Alternatives to RG58 in Lightspeed Ignition Wiring

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

PPT 802, Proximity Probe Transducer System

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink QT-III Silicone Rubber Termination

S6 BATTERY REPLACEMENT

IMPORTANT! READ BEFORE INSTALLING!

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

System Date of Issue Bulletin Number Bulletin Type. Title: Elimination of AC Connectors J29a and J29b

Voice/Data/ Video Tools

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

WARNING. Important Notice

M GT 2005 up Mustang ENGINE START Push-Button INSTRUCTION SHEET

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402

918 Remote Control Switches

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

Solstice Electric Fryers SE Series Service Manual

American Standard ProAx Triaxial Camera Connectors Installation Instructions

Always Moving Forward. Operating Manual. Please Read Before Operating Unit. Models D1, DV1, D9 Wire Strippers & Braid Combers

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

Lakela nd H2 Low Speed Stator Coil Installation

HTP PTP/ PTJ Power Connection Kit for Pipes

Job Sheet 1 Installing the Net Watt-Hour Meter

Cold Shrink QS T Trifurcating Transition Splice Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs

HVS S 15kV Class

QUICKTERM TERMINATION KIT

Termination Procedure for 723 Series SolderTacts Contacts for Coaxial Cable: D , D

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

CETAC Z-Drive Nylon Cable

Installation Instructions

Athearn Pacific Digital Sound Decoder Installation Notes

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

WRSS Wraparound Repair Sleeve Installation Instructions

BD Dual Transmission Cooler Dodge (68RFE, 518, 47RH, 47RE & 48RE) Ford (5R110) & Chevy (Allison 1000) Transmissions

Around the cable. Stripping.... convincing solutions

SUBMERSIBLE TRANSDUCER CABLE REPAIR

Upgrade v3 to v3.2. SeeMeCNC Guides. Upgrade v3 to v3.2. Rostock Max v3 Uprgade to v3.2. Written By: SeeMeCNC seemecnc.dozuki.

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

Around the cable. Stripping. Cable strippers, Wire stripping pliers. haupa...technology that connects

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

3M Cold Shrink Splice Kit QS-III 5536A

Application Note. KATO SD40-2 Mid Tsunami Digital Sound Decoder Installation Notes

I n s t a l l a t i o n I n s t r u c t i o n s

Custom Dynamics Spyder Stingerz Installation Instructions

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

PROBLEMS OR QUESTIONS? Or via

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Installation Instructions

Athearn SD40T-2 Tsunami Digital Sound Decoder Installation Notes

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

C A Heating Cable Gland Kit Installation Instructions

* * Inside Toyota Avalon. Tools Required IMPORTANT

Signal Mirror Installation Instructions

Accessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms

Signal Mirror Installation Instructions Standard West Coast Mirror

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

CI 3000 Coil Inserter

LTX RF LEVEL SENSOR. Instruction Manual

Headlamp Durability Enhancement

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

DCS-400 Measuring Chains with LIN-340 Signal Conditioner and 10m Triaxial Cable Front End Installation Manual

Power Connection Kit installation instructions

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

Step #1 From your spool of 18 gauge primary wire, cut between 11 and 21 three inch strips of wire. You will only need 11 for the ROV, but it is good t

Transcription:

MX8020-001 Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable The Metrix MX8020-001 Cable Trimming and Connector Kit provides an easy way to reduce the length of an extension cable and maintain the electrical integrity of the MX8030/8031 or MX2030/2031 Proximity Probe System. This kit coupled with the Metrix Digital Proximity System software provides the means for plants, OEM s and packagers to clean up their cabinets and enclosures from the usual coils of cable associated with Proximity Probe Systems. Part# 100951 REV A (January 2018)

MX8020-001 Cable Connector Kit Manual Parts Included Quantity Description 1 Hand Crimping Tool 1 Crimping Tool Die for Cable Connectors 1 Triaxial Cable Cutter (Black Cartridge) 1 Wire Cutter 1 Wire Stripper 10 MX8031 Cable Connectors 10 Shrink Tubing Segments Parts not Included, but recommended for procedure Needle Nose Pliers Heat Gun (for the Shrink Tubing) Safety Glasses Accessories not included MX8020-002 Cable Connector Refill Kit Quantity Description 1 Cable Cutter Cartridge (Black) 20 MX8031 Cable Connectors 20 Shrink Tubing Segments Part# 100951 REV A (January 2018) Page 2 of 5

Procedure: 1. Cut the MX8031 Triaxial Cable to the desired length using an appropriate wire cutting tool. 2. Use the Triaxial Cable Cutter with the Black Cartridge (1 active blade) to remove approximately 25mm (1.0 ) of the outer shield of the triaxial cable. This is the most difficult step of this process. The armor shield is very tough and rugged. Be careful with sharp edges and bare wires. With proper blade adjustment, rotate the cutter at least ten times for a clean cut. Use the wire strippers to remove the triaxial shield (10 AWG, 2.6mm). A proper cut may leave the clear coaxial jacket of the coaxial cable (clear plastic covering) intact. Adjust the blade and tension to obtain the desired depth of cut, you don t want to cut through the coaxial shield so you may have to remove the clear coaxial jacket with the wire stripping tool (14 AWG, 1.6mm). 3. Remove the clear coaxial jacket without cutting into the coaxial shield using the wire stripping tool if necessary. Put the shield ferrule over the coaxial cable shield, with the thicker edge away from the cut (or trimmed) end. Move the ferrule down the coaxial cable so it meets the blue triaxial cable. Slide on the blue heat shrink tubing. Part# 100951 REV A (January 2018) Page 3 of 5

4. Pull back, and fan out, the wire coaxial shield to the ferrule to expose the center conductor insulator and conductor. Use the wire strippers to expose approximately 6mm (0.25 ) of the center conductor (22 AMG, 0.80mm). Gently twist the center conductor wire, then slide the center core pin onto the center conductor wire and insulator. 12mm 6mm 6mm 5. Push the shield onto the shield side of the center core pin. Slide the ferrule onto the center core pin to cover 30% of the back end of the center core pin. Trim off the shield to 30% engagement on the pin. This will allow the ferrule to slide up easier and still maintain shield engagement. Put the wire strippers in the locked positon and use the strippers as a drift (stop) for the pin body. This will help you with counter force to slide the ferrule on. Do not let the center core pin slip while sliding on the ferrule. Do not let shield wire extrude beyond the ferrule, or it will make installing the connector difficult. Remove excess coaxial shield that will not fit under the ferrule. Note: The shield takes the cable load not the center pin conductor. 6. Crimp the center core pin, using the.041 hole, next to the connector insulation. Use the kit supplied die and crimping tool. Note: The crush is very light on the center pin conductor. Shrink Wrap Part# 100951 REV A (January 2018) Page 4 of 5

7. Slide the connector onto the center core pin and ferrule. Be careful to ensure the center core pin comes through the connector. Crimp the connector, using the.178 hexagon hole, at the ridge line. Test the connection by pulling on the connector with approximately 8kg (20lbs) of force. Use the hot air gun to shrink the tubing onto the connection. 8. Test the modified MX8031 extension cable. Ensure you have an open circuit between the center pin and the connector case. Ensure you have continuity between the cases at both ends of the cable. Ensure you have continuity between the pin at one end and center conductor at the other end. If any of these checks are not true you must do the connection over again. 9. Ensure you program the Metrix DPS unit (MX2033 or MX2034) for the closest meter electrical length that you now have. Verify the system is linear. Perform calibration if necessary. For instructions on how to modify the Metrix DPS configuration, from the Factory Purchased configuration go to the below link. http://www.metrixvibration.com/tenants/metrix/documents/100545.pdf info@metrixvibration.com www.metrixvibration.com 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1.281.940.1802 Fax: 1.713.559.9421 After Hours (CST) Technical Assistance: 1.713.452.9703 Part# 100951 REV A (January 2018) Page 5 of 5