ICON Link Flowmeter Wiring Manual

Similar documents
Crop Link Pro/Lite Flowmeter Wiring Manual

SOIL MOISTURE MONITORING

WIRING INSTRUCTIONS AQUA-TRAC Lite SOIL MOISTURE MONITORING

Aqua Trac Pro Wiring Manual

AgSense Manual. AgSense, LLC. 259 Dakota Ave S. Huron, SD Phone (605) Fax (605)

3-Stage Retard PN 8970

DYNOTUNE 2 STAGE RPM WINDOW SWITCH WITH TPS INSTALLATION INSTRUCTIONS

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

INSTALLATION, MAINTENANCE & SERVICE MANUAL

INSTALLATION & OWNER'S MANUAL

WiFi Tank Level Monitor Installation Instructions

Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL

A Member of the. Integrated Metering Technologies

Panel Mount Digital Tachometer Model

MSD Boost Control Module PN 7763

Tracer VM with User Interface

PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON.

Electronic Pulse Meters

A Member of the. Integrated Metering Technologies

Toro Sprayer Calibration Tool

EchoPod. Technical Support. Model: DL14-(XX) Quick Start

LU27 Series Quick Start

LU23, LU28 & LU29 Series Quick Start

Lingenfelter ECSS-001 Ethanol Content Sensor Signal Simulator Installation & Operating Instructions

Transmission Guardian

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

This document describes:

Installation and Operation Guide

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

Flap Encoder Installation manual

EAGL 1-Touch Laser Level

INSTRUCTION and OPERATIONS MANUAL. for

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Losi (LOSB9810) 2400mAh 11.1V LiPo Transmitter Battery for JR Z1, KoPropo Helios, and Other Radios of Similar Battery Configuration

MSD Circle Track LS Ignition Control PN 6014CT

Vision Ultra AC/DC Charger

TRUESENSE JOHN DEERE ROWSENSE

UPPER BIG BLUE Natural Resources District

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

Installation and Operation Guide

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

Cleaning & Sanitizing Instructions

MSD Start/Retard Control PN 8982

AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER!

SLX300. Register your product. Send us your photos. Warranty COLOR CHANGING HEADLIGHT ACCENT LIGHTING SYSTEM. Installation Manual

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

Installation Instructions

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

Ford Mustang. Installation Manual

Model Railroad Circuit Breaker (CB-1)

USER GUIDE 1 USER GUIDE

Series II ODYR/SLX-01-1-C PERFORMANCE SPEEDOMETER

5 Gallon Tall Tea Dispenser 3 Gallon Tall Tea Dispenser TALL TEA DISPENSERS. Cleaning & Sanitizing Instructions

MSD Boost Control Module PN 77631

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

SOLAR DASH CHARGING SYSTEM USER GUIDE

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3

REMOTE CENTRAL LOCK. Model: CLRxxx-ULT

Ultimate 5th Wheel Connection Rail Mount. Part #3200 Gooseneck Mount, 20,000 lbs GTWR - 4,500 lbs Tongue INSTALLATION MANUAL

RS-110 Rainfall Sensor Installation Guide

Tracer VMA with AutoReg

USER S MANUAL CDL S AUTOMATIC DRAW-OFF VALVES. Les Équipements d Érablière CDL inc.

Rig Master Power by Mobile Thermo Systems Inc.

12V DC MOTORISED OPENER FOR SWING GATES Section Table of Contents Page

MSD Blaster Ignition PN 5900

Installation & Operators Manual

ULX210. Register your product. Send us your photos. Warranty COLOR CHANGING LED UNDERCAR LIGHTING SYSTEM. Installation Manual

Mustang. Installation Manual

Speedometer Interface

BroadBand PowerShield. 20 AHr Battery. User Manual

WINDOW AIR CONDITIONER SUPPORT BRACKET

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION AND OPERATION MANUAL FOR MCH-GPS17 GPS Compass and Ambient Temperature Gauge. NUTS (x3) 1 +12V TEMP SENSOR

E7000 AND E7500 INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR. 4 TO 20 ma ANALOG TRANSMITTERS

PROPHET PLUS LCD INSTRUCTION MANUAL Horizon Hobby, Inc Fieldstone Road Champaign, IL USA

Installation supplement for. European Integrated Systems, Ltd. Enhanced BMW Bluetooth Interface. Table of Contents

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

Enter your and password then drag the car to the right.

BIM-17-2 Bus Interface Module for compass and outside temperature

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

INSTALLATION INSTRUCTIONS

Infinitybox Express Road Race Car Kit Installation Guide

For questions or technical support, 1. Wiring Reference:

NO SINGLE STAGE PROGRESSIVE, TPS, RPM WINDOW SWITCH

Classic Instruments Ford F100. Installation Manual

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS. Version 1.2

ONE-YEAR SERVICE AND FREIGHT WARRANTY GUIDELINES

Installation Instructions

Installation Instructions **THIS RAIL MOUNTING KIT USES 11 BOLTS**

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

3-Stage Retard PN 8970

Crop Link Pump Control Wiring

Speedo With Telltales and Display 85mm Tech Support Instruction Sheet # A2C Rev

This document describes:

ActuLink ABS Module - ABS-MOD-400

Braun Public Use. Paratransit Conversion Rev A

Transcription:

2017-18 ICON Link Flowmeter Wiring Manual Revised January 1, 2018

Items Covered In This Manual: Page 2: Netafim/Dwyer Mechanical Flow Meter Wiring Page 3: Netafim Octave Flow Meter Wiring Page 4: GF Signet Open Collector Flow Meter Wiring Page 5-9: GF Signet 8550 Flow Transmitter Wiring Page 10: McCrometer Mechanical Flow Meter Wiring Page 11-12: Seametrics AG2000 AG3000/Valley Flow Meter Page13-14: Endress Hauser Promag P 50/53 Flow Meters Page 15-16: Siemens MAG5000 Flow Meters Page 17-19: Seametrics PE102/FT520 Flow Meter Wiring Page 20-22: GF Signet 9900 Flow Transmitter Wiring Page 23-24: GF Signet 2551 Mag Meter Wiring Page 25: McCrometer FlowCom Flow Meter Wiring Page 26-27: McCrometer McMag 3000/EA-618 Flow Meters Page 28-29: Siemens Sitrans FM MAG 8000 Wiring Page 30-32: Greyline AVFM 5.0 Flow Meter Wiring Page 33-34: Senninger Flow Wise SC-3 Flow Meter Wiring Page 35-36: Banjo MFM 300DC Flow Meter Wiring Page 37-38: Seametrics FT415 Flow Meter Wiring Page 39-41: Sparling Tiger Mag Flow Meter Wiring Page 42-43: Sparling FT194 Flow Meter Wiring Page 44: Generic Flow Meter Wiring

Wire Connections for the Netafim/Dwyer Mechanical Flow Meter (two wire magnetic reed-switch style) 1. Install the Black Wire from the Netafim/Dwyer Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the Netafim/Dwyer Flow Meter into the terminal marked FLOW as shown in the picture above. Page 2

Wire Connections for the Netafim Octave Flow Meter (with pulse output module) 1. Install the Black Wire from the Netafim Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the Netafim Flow Meter into the terminal marked FLOW as shown in the picture above. 3. Cut off and/or tape off the Green Wire from the Netafim Flow meter so that it cannot touch anything. 4. The label on the inside of the Netafim Flow Meter lid will show how many gallons per pulse that output1 (the red wire) is programmed to do. You will need that info when configuring this unit on Wagnet. Page 3

Wire Connections for the GF Signet/Senniger Open Collector Type Flow Meters Note: The flow meter must be an Open Collector type output. (For example, models: Ag Rotor 4-3000-5, 2507 mini 198-801-732, 2000 micro 198-822-000 flow meters) 1. Install the Black Wire from the GF Signet Flow Meter into the screw terminal marked 5v as shown in the picture above. (add it in with the 5v wire that is already in that terminal) 2. Install the White/Bare Wire from the GF Signet Flow Meter into any terminal marked GND as shown in the picture above. 3. Install the Red Wire from the GF Signet Flow Meter into the terminal marked FLOW as shown in the picture above. Page 4

Wire Connections for the GF Signet/Senniger 8550 Flow Transmitter 1. Install the Power Supply, and Flow Meter wires into the GF Signet 8550 Unit as shown above. 2. Install a Red wire into terminal 5 (output+) of the 8550 Unit as shown above. This wire will connect to the AgSense unit in the steps below. 3. Install a Black wire into terminal 6 (output-) of the 8550 Unit as shown above. This wire will connect to the AgSense unit in the steps on the next page. Page 5

Wire Connections for the GF Signet/Senniger 8550 Flow Transmitter Cont. 1. Install the Black Wire from the GF Signet 8550 Flow Transmitter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the GF Signet 8550 Flow Transmitter into the terminal marked FLOW as shown in the picture above. 3. Setting up the 8550 Flow Transmitter calibrate and options menus use the charts below to correctly set up the menus in the 8550 Flow Transmitter you must do this for the AgSense unit to work properly. Page 6

Page 7

Page 8

Page 9

Wire Connections for the McCrometer Mechanical Flow Meter with EA-631-xxx module The ICON Link does not support the McCrometer EA-631 Pulse Module The new part number for mechanical McCrometer flow meters is EA-618-02. Please use the EA-618-02 Pulse Module for mechanical flow meter installations. Please see page 26 for EA-618-02 Wiring. Page 10

Wire Connections for the Seametrics AG2000, AG3000/Valley Flow Meter Note: The Seametrics AG2000 can come programmed for High-Frequency pulses or Standard Low Frequency Scaled Pulse Output (10 or 100 gallons per pulse) be sure to choose the correct version (HF or LF) in the AgSense unit configuration. Note2: When using external power supply with these Seametrics Flow Meters, you should add a jumper wire from Black (12v-) to the White (pulse -) going to the ICON Link so that all ground wires are connected together. Page 11

Wire Connections for the Seametrics AG2000, AG3000/Valley Flow Meter Cont. 1. Install the White Wire from the Seametrics Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Green Wire from the Seametrics Flow Meter into the terminal marked FLOW as shown in the picture above. Page 12

Wire Connections for the Endress Hauser Promag P 50/53 Series Flow Meter 120v powered meter shown meter must be ordered the correct type with terminals 24 and 25 setup as Frequency Output (pulses) Page 13

Wire Connections for the Endress Hauser Promag P 50/53 Series Flow Meter Cont. 1. Install the Black Wire from the EH Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the EH Flow Meter into the terminal marked FLOW as shown in the picture above. 3. Using the menu on the EH flowmeter, be sure that the display of the flowmeter is set to gallons per minute. Then, using the menu on the EH flowmeter, set the pulse output to 10 gallons per pulse. Page 14

Wire Connections for the Siemens MAG5000 Series Flow Meters 120v powered meter shown In the Siemens MAG5000 Menu, you must make sure the following is set: Page 15

Wire Connections for the Siemens MAG5000 Series Flow Meters Cont. 1. Install the Black Wire from the Siemens Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the Siemens Flow Meter into the terminal marked FLOW as shown in the picture above. 3. Set the Config on Wagnet for this unit to Siemens, and 10 gallons per pulse. Page 16

Wire Connections for the Seametrics FT520 Display / PE102 Flow Meter Connect the PE102 Flow Meter, the AC Power, and a cable to the ICON Link unit as shown. Use the SET button and the arrows on the FT520 display to change the flow rate to Gallons per Minute as shown below: Page 17

Use the SET button and the arrows on the FT520 display to set the decimal point for the display as shown below: Use the SET button and the arrows on the FT520 display to set the K-FACTOR as shown below: (use the actual K-Factor in the documentation for your specific flow meter the number below is only an example.) Use the SET button and the arrows on the FT520 display to set the Pulse Output to the correct scale as shown below: Page 18

Connect the wires from the FT520 unit into the ICON Link: 1. Install the Red Wire from the Seametrics FT520 into the terminal marked FLOW as shown in the picture above. 2. Install the Black Wire from the Seametrics FT520 into any terminal marked GND as shown in the picture above. 3. Set the Unit Config on Wagnet for this unit to SeaMetrics PE102/FT520, and 100 pulses per gallon. Page 19

Wire Connections for the GF Signet 9900 Flow Transmitter Connect the Flow Meter, the DC Power, and a cable to the ICON Link unit as shown above. Page 20

GF Signet 9900 settings: Hold down the Enter button for more than 3 seconds to enter the settings menus. When asked for a password or code, the default is: INPUT MENU 1. Set the sensor TYPE to FLOW. 2. Set the sensor NAME to FLOW. 3. Set the SENSITIVITY to 100 (if using with small flow meters, this number may need to be set lower. (see GF Signet 9900 Manual) 4. Set the AVERAGE to OFF. 5. Set the TOT UNITs to GALLONS 6. Set the FLOW UNITS to GPM (gallons per minute) 7. Set the SENSOR to FREQ for flow meters that output a frequency/pulse (most flow meters) or if you are using a S3L digital flow sensor, set SENSOR to S3L 8. Press the and arrows at the same time to exit this menu. RELAY MENU The RELAY menu enables the open collector (OC+, OC-) output to send pulse data to the ICON Link unit. The Relay 1 settings are what turns on the Open Collector output, change the settings as follows: 1. Set R1 to NORMAL OPEN 2. Set R1 MODE to VOL PULS 3. Set R1 VOLUME to 10.00 4. Set R1 PULSE WIDTH to 0.1 5. Press the and arrows at the same time to exit this menu. 6. Press the and arrows again at the same time to exit the settings menus and return to normal operation. Continue to the next page for ICON Link Unit wiring. Page 21

Connect the wires from the GF Signet 9900 into the ICON Link: 1. Install the Red Wire from the GF Signet 9900 into the terminal marked FLOW as shown in the picture above. 2. Install the Black Wire from the GF Signet 9900 into any terminal marked GND as shown in the picture above. 3. Set the Unit Config on Wagnet for this unit to GF Signet 8550 / 9900, and 10 pulses per gallon. Page 22

Wire Connections for the GF Signet 2551 Mag Flow Meter with Frequency Output 1. Make sure the jumper shown above is in place for this meter to output frequency. 2. Install a black wire into terminal 1 (5v input) in the 2551 Mag Meter. 3. Install a red wire into terminal 2 (pulse output) in the 2551 Mag Meter. 4. Install a white wire into terminal 3 (ground) in the 2551 Mag Meter. Page 23

Connect the wires from the 2551 into the ICON Link: 1. Install the Black Wire from the GF Signet Mag Meter into 5v terminal as shown in the picture above, with the other 5v wire that is already there. (there will be 2 wires in the 5v terminal at the same time) 2. Install the White Wire from the GF Signet Mag Meter into any terminal marked GND as shown in the picture above. 3. Install the Red Wire from the GF Signet Mag Meter into the terminal marked FLOW as shown in the picture above. Page 24

Wire Connections for the McCrometer FlowCom Flow Meter 1.Install the Green Wire from the McCrometer Flow Meter into any terminal marked GND as shown in the picture above. 2.Install the Bare Wire from the McCrometer Flow Meter into any terminal marked GND as shown in the picture above. 3.Install the White Wire from the McCrometer Flow Meter into the terminal marked FLOW as shown in the picture above. Page 25

Wire Connections for the McCrometer McMag 3000 Or EA-618-02 Flow Meters Page 26

Wire Connections for the McMag 3000 / EA-618-02 1. Install the Yellow Wire from the McCrometer Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Grey Wire from the McCrometer Flow Meter into the terminal marked FLOW as shown in the picture above. 3. On the wagnet website, Config Tab, select McMag3000 from the Digtal 1 Flow selection, and set the gallons per pulse of this flow meter to 100 (this is the normal amount set by the factory when the flow meter was manufactured) Page 27

Wire Connections for the Siemens Sitrans FM MAG 8000 Flow Meter 1. Install a Red wire into terminal 56 of the flow meter. This wire will go to the ICON Link Unit. 2. Install a Black wire into terminal 57 of the flow meter. This wire will go to the ICON Link Unit. 3. Also install a jumper wire into terminal 57 of the flow meter and connect the opposite end of the wire to one of the metal screws on the brackets that support the circuit boards inside the flow meter. Page 28

Wire Connections for the Siemens Sitrans FM MAG 8000 Flow Meter 1. Install the Black Wire from the Sitrans Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the Sitrans Flow Meter into the terminal marked FLOW as shown in the picture above. Page 29

Wire Connections for the Greyline AVFM 5.0 Flow Meter 1. Install a Red wire into the Relay 1 Normally Open terminal of the flow meter. This wire will go to the ICON Link. 2. Install a Black wire into Relay 1 Common terminal of the flow meter. This wire will go to the ICON Link. 3. Make sure the Menu Settings have been set to Gallons Per Minute, and Relay 1 set for pulse output as shown in the photos on the next page. Page 30

AVFM 5.0 Menu Settings Make certain the units is setup as Gallons Per Minute as shown above Make certain that Relay 1 is setup for Pulse operation, and set the gallons per pulse (10 gallons per pulse shown above) Depending on the size of pipe/channel that you are measuring, you will want to set the Gallons per pulse to a larger : 10.0=Small Pipe (less than 100 GPM) 100.0=Medium Pipe (100-1000 GPM) 1000.0=Large Pipe (1000+GPM) Page 31

Wire Connections for the Greyline AVFM 5.0 Flow Meter 1. Install the Black Wire from the Greyline Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the Greyline Flow Meter into the terminal marked FLOW as shown in the picture above. Page 32

Wire Connections for the Senninger Flo-Wise SC-3 Flow Meter 1. Install the wires from the flow meter to the SC-3 as shown (consult your flo-wise instruction manual for flow meter wiring variations). 2. Install the DC power supply to terminals 7 and 8 as shown above. 3. Install the pair of wires from the ICON Link unit to terminals 9 and 10 as shown above. 4. Configure the SC-3 Pulse Output in the SC-3 menu to output a pulse every 100 gallons. Page 33

Wire Connections for the Senninger Flo-Wise SC-3 Flow Meter 1. Install the Black Wire from the SC-3 Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the SC-3 Flow Meter into the terminal marked FLOW as shown in the picture above. 3. On the ICON Link unit config page, choose GF Signet 8550/9900/SC-3 in the Digital 1 Options section, and enter 100 gallons per pulse. Then click Save Config at the bottom of the page. Page 34

Wire Connections for the Banjo MFM300DC Flow Meter 1. Install the brown power wire from the flow meter to + terminal of a 10-30v DC power supply as shown above.(not supplied by AgSense) 2. Install the 4 Ground wires from the flow meter, and the Ground wire from the CommanderVP / ICON Link unit into a wire nut with the wire from the DC power supply as shown above. (all grounds connected together) 3. The Blue pulse output wire from the flow meter goes to the CommanderVP / ICON Link unit. 4. Install the See the next page for CommanderVP / ICON Link wiring. Page 35

Wire Connections for the Banjo MFM300DC Flow Meter 1. Install the Black Wire from the Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Blue Wire from the Flow Meter into the terminal marked 3. FLOW as shown in the picture above. 4. On the ICON Link unit config page, choose Banjo in the Digital 1 Options section, and enter 13 Pulses per gallon (high frequency meters) or 1 pulse per gallon (standard frequency meters). Then click Save Config at the bottom of the page. Page 36

Wire Connections for the Seametrics FT415 Flow Meter 1. Install a Black Wire into the FT415 Flow Meter into the terminal marked Pulse Scaled Output - as shown in the picture above. 2. Install a Red Wire into the FT415 Flow Meter into the terminal marked Pulse Scaled Output + as shown in the picture above. Page 37

Wire Connections for the Seametrics FT415 Flow Meter 1. Install the Black Wire from the FT415 Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the FT415 Flow Meter into the terminal marked FLOW as shown in the picture above. 3. ICON Link Unit Configuration: Click on the Config tab, and in the Digital 1 Options section, select TigerMag from the flow meter list, and enter either 10 or 100 gallons per pulse (depeding on how you set the flow meter settings above. Page 38

Wire Connections for the Sparling Tiger Mag Flow Meter The Tiger Mag Flow Meter must be an OPEN COLLECTOR output contact Sparling for more info. 1. Install a Black Wire into the Tiger Mag Flow Meter into the terminal marked Open Collector - as shown in the picture above. 2. Install a Red Wire into the Tiger Mag Flow Meter into the terminal marked Open Collector + as shown in the picture above. Page 39

Wire Connections for the Sparling Tiger Mag Flow Meter 1. Install the Black Wire from the Tiger Mag Flow Meter into any terminal marked GND as shown in the picture above. 2. Install the Red Wire from the Tiger Mag Flow Meter into the terminal marked FLOW as shown in the picture above. 3. See the next page for flow meter menu settings. Page 40

Sparling Tiger Mag Flow Meter Menu Settings Tiger Mag menu: Rescale Rate menu: Rate units = GPM Conversion Factor 1=1.0000000 GPM Rescale Total menu: Count direction = FWD Only TOT Units = GAL Set Registration = 10 or 100 (depends on how much total flow GPM you are going to have, low amounts of flow use 10, high amounts of flow (higher than 600-700 gpm) use 100 this equals how many pulses per minute this flow meter will send, and you will enter this same number (10 or 100) on the ICON Link Config page in the Gallons Per Pulse section. Set Outputs menu: Empty Pipe Detection (EPD) = 5 this is just a starting point, these meters default to EPD=0 and thus will count some flow when the pipe is empty, so need to start with 5 and adjust from there to see what works best, refer to the Tiger Mag manual for more information. ICON Link Unit Configuration: Click on the Config tab, and in the Digital 1 Options section, select TigerMag from the flow meter list, and enter either 10 or 100 gallons per pulse (depeding on how you set the flow meter settings above. Page 41

Wire Connections for the Sparling FT194 Flow Meter 1. Install a Black Wire into the Flow Meter in the terminal marked #4 Pulse OC - as shown in the picture above. 2. Install an Orange Wire into the Flow Meter in the terminal marked #3 Pulse OC as shown in the picture above. 3. Flow meter also requires power to operate. Install wires from a 12v DC regulated power supply into terminals #1 and #2 (4-20mA Loop) and make sure the Ground wire is also looped over to terminal #4. Page 42

CommanderVP Connections for the Sparling FT194 Flow Meter 4. Install the Black Wire from the Flow Meter into any terminal marked GND as shown in the picture above. 5. Install the Orange Wire from the Flow Meter into the terminal marked FLOW as shown in the picture above. Page 43

Generic Flow Meter Wiring Any flow meter with pulse output can be connected to the Aqua Trac Unit. Requirements: 1. Flow meter must have an isolated (not self-powered) pulse output that is either a switch/relay closure style, or an electronic open collector type pulse output. The important part is that the flowmeter needs to connect the two wires shown above together for each pulse. 2. Each Pulse momentarily connects the two wires together to indicate a pulse, then disconnects them again. The Pulse must be longer than 2ms each. 3. Flow meter typically is setup so each pulse is either 10 or 100 gallons per pulse. (depending on flow meter size) For example, systems that typically flow less than 300GPM, use 10 gallons per pulse - and systems that typically flow more than 300GPM, use 100 gallons per pulse. Page 44

Power Requirements for these units: DC Powered Unit 7-40V DC: At 12v DC: 1.0A MAX 0.1A - 0.5A during normal operation Warranty Information: All warranty service provided by the AgSense service center, or an authorized technician. Warranty repairs require a Return Merchandise Authorization Number (RMA); Have your dealer contact AgSense to obtain this RMA number. For the Period of : AgSense will: 60 Days Money back Guarantee if not satisfied with product. 2 Year Repair on any unit that fails due to defect in materials or workmanship. AgSense labor and parts would be provided free of charge during the warranty period. (This does not include dealer labor.) What is not covered: Service trips to your home to teach you how to use the product. Improper installation, delivery or maintenance. If you have an installation problem contact your dealer or installer. Failure of product resulting from modification to product or due to unreasonable failure to provide reasonable and necessary maintenance. Labor necessary to move device from one location to another. Improper installation of battery. Failure due to corrosion or water damage. o Units installed in direct contact with sprinklers require a tower box or other watertight protection. Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God. Damage caused after delivery. Page 45

Exclusion of implied warranties Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. This warranty is extended to the original purchaser and any succeeding owner for the products purchased for use within the USA. Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have the other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state s Attorney General. DISCLAIMER: The use of Field Commander/Crop Link shall not be utilized by customer as a substitute for the Customer's personal observation of the manner in which Customer's irrigation equipment is functioning. AgSense specifically advises Customer that this product is designed to enhance Customer's ability to control existing irrigation equipment and to provide the Customer with additional information about existing irrigation equipment. Field Commander/Crop Link relies upon GPS, Satellite and Internet technology which not always functions properly, accordingly, AgSense disclaims any and all responsibility for the reliability of this technology. Customer acknowledges that AgSense does not have the ability to control the reliability of GPS, Satellite and Internet Technology. AgSense specifically disclaims any and all liability for Customer's failure to personally determine whether or not the irrigation equipment that belongs to Customer is functioning properly. AgSense, its agents, members or officers will not be liable for Customer's loss of profits, business interruption, or any other type of consequential damages arising because of the failure to Customer's equipment, GPS, Satellite or Internet to function properly. CUSTOMER'S RESPONSIBILITIES: Customer agrees to keep the irrigation equipment upon which Field Commander/Crop Link is installed in good repair and maintenance. Customer acknowledges the importance of and agrees to keep all safety devices which came with Customer's irrigation equipment in working order. Customer agrees to keep an end field stop and barricades in place to prevent damage to the irrigation equipment in the event that Field Commander/Crop Link malfunctions. Customer agrees that Field Commander/Crop Link cannot solely replace the personal monitoring of the operation of irrigation equipment. REMEDY: Customer acknowledges that Field Commander/Crop Link s sole obligation and Customer's exclusive remedy in the event of any material and continuing nonconformity, defect, or error in the information service shall be to take reasonable corrective actions upon discovery of the problem.

AgSense, LLC 259 Dakota Ave S PO Box 53 Huron, SD 57350 605-352-8350 www.agsense.net