Electronic Heat Meters

Similar documents
Electronic Water Meters

Electronic Water Meters in measuring cell design

Electronic Water Meters

Heating Cost Allocation Valve with local acquisition of the flow temperature

Supercal 539. Compact thermal energy meter

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

F 90 Heat Meter Warmly recommended to cool-headed economisers

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Measuring capsule heat meter G54 / G55

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

M-bus impeller type heat and heat/refrigeration meters

Fluidic Oscillation Compact Heat Meter

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

zelsius Installation and operating manual All that counts EnergyMetering

RAY COMPACT ENERGY METER MECHANICAL

zelsius Installation and operating manual All that counts. EnergyMetering

WZMC-402 Ultrasonic Apartment Energy Meters

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Paddle-wheel flow controller with optical principle for On/Off control

Heating / Cooling Meter PolluCom E Installation and Operation Instructions

Heat Meter Integrator

SonoMeter 30 Energy Meters

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Compact Static Heat Meter of High-Tech Composite

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Immersion temperature sensor QAE26.9.

CORONA E ELECTRONIC METER MULTI-JET

Paddle-wheel flow controller for On/Off control

WESAN WPV E ELECTRONIC METER WOLTMAN

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

SonoMeter 30 Energy Meters

Ultrasonic heat meter

Temperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features

Heat / Chill Meter PolluCom M Installation and Operating Instructions. PolluCom M. Installation and Operating Instructions. M H 1210 INT, Page 1

COMPONENTS FOR SOLAR THERMAL SYSTEMS

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Paddle-wheel flow controller for On/Off control

Compressed Air-Supply Meter

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

VPI45..Q with pressure test points. Combi valves, PN 25

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

HYDRUS ULTRASONIC METER

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Supercal 539 Universal compact heat meter

Combi valves PN 16 with flanged connections

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

SITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

Differential Pressure Sensors

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Horizontal Distribution Units - HDU Multi-port

INSERTION flow sensor for continuous flow measurement

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

INSERTION flowmeter with paddle wheel, ELEMENT design

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

HYDRUS ULTRASONIC METER

VPI45..Q with pressure test points. Combi valves, PN 25

Residential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Two-port seat valves with male thread, PN16

Differential Temperature Controller

TURBINE FLOW METER SELECTION GUIDE

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

FEATURES AND BENEFITS

Hydro-Flow Model 3100

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

Differential Pressure Sensors

Differential Pressure and Flow meters Accessories for the Media Series

tprime TM Series 280T

RVD G2383en. Installation. - Compact station - Control cabinet (in the front, on the inner wall or on a

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

Differential Pressure Sensors

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Cable Temperature QAP... Sensor. Use

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Turbine gas flow quantometer series CPT

Type Electronic Limit Switch

Differential pressure sensor

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Mounting and Operating Instructions EB 5868/5869 EN

ULTRASONIC HEAT METER

aquaconcept Product features Customer benefits

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Continuous level sensor NSK

Pressure Sensors. for liquid and gaseous media

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Transcription:

5 333 WFQ2... WFM2... MEGATRON2 Electronic Heat Meters WFM2... WFQ2... Electronic, mains-independent meters to acquire heating energy consumption in autonomous heating and domestic hot water plants. Storage and display of the cumulated consumption values on a selectable set day. Available as single-jet meters in «combined» all-in-one or split version Nominal flow rates of single-jet meters 0.6 m 3 /h, 1.5 m 3 /h or 2.5 m 3 /h. MEGATRON2 is a component of the SYNERGYR M-Bus Metering and SYNERGYR Radio Metering Systems. Use MEGATRON2 meters are used for measuring heating energy. Their major field of use are central heating plants, where heating energy is delivered individually to several consumers. Plants of this type are used in buildings such as: Multi-family houses Office and administrative buildings Typical users are: Private building owners Property associations Building maintenance companies Housing estate agents CE1N5333E 08.01.2002 Siemens Building Technologies HVAC Products

Functions Acquisition of heating energy consumption based on the measurement of flow rate and temperature differential Cumulation of the consumption values Storage of the cumulated consumption values on the set day Display of the consumption values Display of the key operational data Self-supervision, with fault indication Data transmission via M-bus or radio Type summary List of heat meters Nominal Temperature sensors Communication Type ref.** flow rate q p Cable length Immersion Return sensor 0.6 m 3 /h 110 mm 1.5 m directly integrated via M-bus * WFM21.B111 1.5 m 3 /h 110 mm 1.5 m directly integrated via M-bus * WFM21.D111 2.5 m 3 /h 130 mm 1.5 m directly integrated via M-bus * WFM21.E131 0.6 m 3 /h 110 mm 2.5 m directly integrated via M-bus * WFM21.B112 1.5 m 3 /h 110 mm 2.5 m directly integrated via M-bus * WFM21.D112 2.5 m 3 /h 130 mm 2.5 m directly integrated via M-bus * WFM21.E132 0.6 m 3 /h 110 mm 1.5 m directly integrated via radio WFM22.B111 1.5 m 3 /h 110 mm 1.5 m directly integrated via radio WFM22.D111 2.5 m 3 /h 130 mm 1.5 m directly integrated via radio WFM22.E131 0.6 m 3 /h 110 mm 2.5 m directly integrated via radio WFM22.B112 1.5 m 3 /h 110 mm 2.5 m directly integrated via radio WFM22.D112 2.5 m 3 /h 130 mm 2.5 m directly integrated via radio WFM22.E132 0.6 m³/h 110 mm 1.5 m directly integrated pulse output WFM24.B111 1.5 m³/h 110 mm 1.5 m directly integrated pulse output WFM24.D111 2.5 m³/h 130 mm 1.5 m directly integrated pulse output WFM24.E131 0.6 m³/h 110 mm 2.5 m directly integrated pulse output WFM24.B112 1.5 m³/h 110 mm 2.5 m directly integrated pulse output WFM24.D112 2.5 m³/h 130 mm 2,5 m directly integrated pulse output WFM24.E132 1.5 m 3 /h 80 mm 1.5 m directly not integrated via M-bus * WFQ21.D081 1.5 m 3 /h 80 mm 2.5 m directly not integrated via M-bus * WFQ21.D082 1.5 m 3 /h 80 mm 1.5 m directly not integrated via radio WFQ22.D081 1.5 m 3 /h 80 mm 2.5 m directly not integrated via radio WFQ22.D082 1.5m³/h 80mm 1.5m directly not integrated pulse output WFQ24.D081 1.5m³/h 80mm 2.5m directly not integrated pulse output WFQ24.D082 1.5 m 3 /h 110 mm 1.5 m indirectly integrated via M-bus * WFM21.D115 2.5 m 3 /h 130 mm 1.5 m indirectly integrated via M-bus * WFM21.E135 1.5 m 3 /h 110 mm 2.5 m indirectly integrated via M-bus * WFM21.D116 2.5 m 3 /h 130 mm 2.5 m indirectly integrated via M-bus * WFM21.E136 1.5 m 3 /h 110 mm 1.5 m indirectly integrated via radio WFM22.D115 2.5 m 3 /h 130 mm 1.5 m indirectly integrated via radio WFM22.E135 1.5 m 3 /h 110 mm 2.5 m indirectly integrated via radio WFM22.D116 2.5 m 3 /h 130 mm 2.5 m indirectly integrated via radio WFM22.E136 1.5 m³/h 110 mm 1.5 m indirectly integrated pulse output WFM24.D115 2.5 m³/h 130 mm 1.5 m indirectly integrated pulse output WFM24.E135 1.5 m³/h 110 mm 2.5 m indirectly integrated pulse output WFM24.D116 2.5 m³/h 130 mm 2.5 m indirectly integrated pulse output WFM24.E136 * Prepared for communication via M-bus ** Short-form MEGATRON2 2/10

Scope of delivery of heat meters Item Temperature sensors, cable length and immersion Packing 80 mm 110 mm, directly 110 mm, indirectly 130 mm, directly 130 mm, indirectly Flow measuring section Box Electronic unit Box Temperature sensor with fitting Box Temperature sensor without fitting Box Bracket Box Protective cap 2 2 2 2 2 Box Mounting instructions Box Commissioning and operating instructions Box Flat seal 2 2 2 2 2 Bag 1 Sealing wire 3 2 2 2 2 Bag 1 Self-lock seal 3 2 2 2 2 Bag 1 (Adhesive seal) Bag 1 Fischer dowel S6 2 2 2 2 2 Bag 2 Screws C4, 2x25 2 2 2 2 2 Bag 2 Blanking screw Bag 3 Flat seal for blanking screw Bag 3 List of mounting kits Scope of delivery, description Type reference For 80 mm mounting length, both sensors directly immersed, flow temp. sensor in ball valve WFZ.E80 For 80 mm mounting length, return temp. sensors directly immersed, flow temp. sensor in ball valve WFZ.E80G3 For 110 mm mounting length, return temp. sensors directly immersed, flow temp. sensor in ball WFZ.E110-I valve For 110 mm mounting length, return temp. sensor indirectly immersed, flow temp. protection pocket WFZ.E110-IT For 110 mm mounting length, return temp. sensor directly immersed, flow temp. ball valve WFZ.E110G3-I For 110 mm mounting length, return temp. sensor indirectly immersed, flow temp. protection pocket WFZ.E110G3-IT For 130 mm mounting length, return temp. sensor directly immersed, flow temp. ball valve WFZ.E130-I For 130 mm mounting length, return temp. sensor indirectly immersed, flow temp. protection pocket WFZ.E130-IT For 130 mm mounting length, return temp. sensor directly immersed, flow temp. ball valve WFZ.E130G1-I For 130 mm mounting length, return temp. sensor indirectly immersed, flow temp. protection pocket WFZ.E130G1-IT Scope of delivery of mounting kits Accessory Mounting kit WFZ.E... E80 E80G3 E110-I E110-IT E110G3-I E110G3-IT E130-I E130-IT E130G1-I E130G1-IT Spacer Ball valve, internally threaded ½, for use in return pipe, cap nut * ¾, with thread for sensor, flat seal ¾ Ball valve, internally threaded ½, for use in return pipe, cap 2 2 2 2 nut* ¾, flat seal ¾ Ball valve, internally threaded ¾, for use in return pipe, fitting ¾ with cap nut 1, flat seal 1 2 2 2 2 3/10

Ball valve, internally threaded ½, for use in flow pipe, with thread for sensor Ball valve, internally threaded ¾, for use in flow pipe, with thread for sensor Ball valve, internally threaded 1, for use in flow pipe, with thread for sensor T-piece, internally threaded ½, for use in flow pipe T-piece, internally threaded ¾, for use in flow pipe T-piece, internally threaded 1, for use in flow pipe Protection pocket M10x1 * Cap nut integrated in ball valve (cannot be removed) List of accessories Accessory Description, scope of delivery Type reference Spacer For mounting length 80 mm (¾ male) WFZ.R80 Spacer For mounting length 110 mm (¾ male)) WFZ.R110 Spacer For mounting length 130 mm (1 male) WFZ.R130 Ball valve Connecting thread ½, with thread for sensor WFZ.K16 Ball valve Connecting thread ¾, with thread for sensor WFZ.K19 Ball valve Connecting thread 1, with thread for sensor WFZ.K22 T-piece Internally threaded ½, with protection pocket M10x1 WFZ.T15 T-piece Internally threaded ¾, with protection pocket M10x1 WFZ.T18 T-piece Internally threaded 1, with protection pocket M10x1 WFZ.T22 M-bus connection kit 1 plug with cable (1 m long),1 adhesive label WFZ.MBUSSET Bezel Only for surface mounting, when the electronic unit is installed separately from the volume meter WFZ.B4 Ordering When ordering, please give type reference according to «Type summary». MEGATRON2 comes standard with an M-bus output. If the heat meter is connected to a SYNERGYR M-Bus Metering System, the M-bus connection kit is required. For the pulse output version the M-bus connection kit is also required. If a set day other than 31 December is required, the desired month is to be added to the type reference when ordering (normally, the last day of the month is the set day). Ordering example for a heat meter, 130 mm mounting length, set day 30 April: WFM21.E131, set day: April. Technical design Measurement principle The meter operates based on the single-jet measurement principle where the water jet hits the impeller tangentially. The impeller's speed is sensed electronically without producing a magnetic field. The temperatures in the flow and return pipes are measured with immersion type platinum sensing elements (Pt 500). 4/10

Acquisition of heat consumption Storage of consumption values Display Fault status signals The heat meter is designed for mounting in the return pipe. The flow measuring section measures the flow continuously and the flow and return temperatures at least once per minute. A microprocessor in the flow measuring section determines the temperature differential, which the microprocessor uses along with the mean flow rate and the heat coefficient, to calculate the amount of heat consumed. The heating energy consumption values are continuously cumulated. At 23:59 hours of the next set day, the actual meter reading will be stored. The set day is factory-set, the standard setting being 31 December (also refer to «Ordering»). At the same time the annual consumption values are stored, the meter calculates a verification code. Tenants who make their own reading need to give this code to the billing center, along with the set day reading. This enables the billing center to verify the reading. The stored set day value will be retained for one year. The heat meter has three display levels which show the following values and variables: Cumulated heating energy consumption since the last set day Segment test Actual heating energy output Actual flow rate Actual flow temperature Actual return temperature Actual temperature differential Meter's number of operating hours since it was first installed Set day and set month Stored heating energy consumption of previous year Stored heating energy consumption of the last 13 month Verification code Cumulated heating energy consumption since the meter was first installed Indication of faults (also refer to section below) The units displayed are C or K, kwh (or GJ on request), m 3 /h, kw, and hours. Standard display is the cumulated heating energy consumption. The meter monitors itself and can display faults it has detected. It differentiates between two categories of faults. Temporary faults: they have no impact on the correct functioning of the meter. In that case, the display flashes for 32 seconds and then returns to the standard display. Severe functional faults: the measurements have been stopped. In that case, the display alternates between error code and date the fault occurred the first time. The values that have been cumulated until the fault first occurred remain stored. Mechanical design The heat meter is comprised of flow measuring section, electronic unit and two temperature sensors. The flow measuring section is mounted in the piping with the help of fittings. It is made of nickel-plated brass and contains the measuring chamber with the single-jet impeller. The inlet has a strainer to retain larger dirt particles. The meter is supplied as a compact all-in-one unit, but the electronic unit can be detached if required (split version). Electronic display unit The electronic display unit houses the electronics and the eight-digit LCD. The operating voltage of DC 3 V is supplied by a lithium battery. Below the display, there is a button for advancing the display. The electronic display unit on the flow measuring section can be swiveled through 360 and tilted by 90. 5/10

Temperature sensors The temperature sensors are immersion type sensors. They are immersed either indirectly or directly. The temperature sensors consist of an immersion rod the end of which carries the sensing element (Pt 500), the threaded nipple, and the shielded silicon cable which establishes the connection to the electronic display unit. The temperature sensors are designed for fitting in ball valves (direct immersion) or protection pockets (indirect immersion). The temperature sensors used are ready mounted, approved, mounted as pairs, or certified. Sizing p 1,0 Q p 0,6 m 3 /h Q Q p 2,5 m 3 p 1,5 m 3 /h /h 0,5 0,4 0,3 0,2 0,1 0,05 0,04 0,03 0,02 0,01 0,2 0,3 0,4 0,5 0,6 1,0 1,2 1,5 2 2,5 3 4 5 6 Q 5333D01 Pressure drop characteristic p Pressure drop in bar Q Flow rate in m 3 /h Mounting notes The local regulations for the use of heat meters (mounting, sealing, operation, etc.) must be complied with. The heat meter must be mounted in the return pipe between two shutoff valves. To facilitate readout and service work, it should be easily accessible. A settling path is required just upstream of the meter: 150 mm with the mounting lengths 80 mm and 110 mm 200 mm with the mounting length 130 mm If the meter is only used at the time of commissioning, it is possible to fit the spacer first. Prior to mounting the meter, the piping must be thoroughly flushed; for this purpose, the spacer is to be used. When mounting the meter, the direction of flow (indicated by an arrow on the body) must be observed. If T-pieces of other manufacture are used, it must be ensured that they are compliant with EN1434! The electronic display unit can be mounted away from the flow measuring section (split version). If the hole in the wall is too large for the display unit, it can be mounted with the help of the mounting cover. If required, a chromium-plated covering plate can be used. The display unit should be located such that it is easy to read. After mounting, the required test pressure must be applied to the plant. The display unit, the two temperature sensors and the fittings must be sealed to ensure protection against tampering. If required, the M-bus service interface must also be sealed. The piece of piping where the temperature sensors are located should be lagged. 6/10

Operating notes For recalibration, the local regulations must be observed. Technical data General Data Measurement accuracy class 3 to EN 1434 Environmental class A to EN 1434 Unit of energy Standard On request kwh GJ Flow rates Min. flow rate q i (Q min ) H / V Nominal flow rate q p (Q nenn ) Max. flow rate q s (Q max ) Starting flow, horizontal Max. perm operating pressure Range of use of flow measuring section 1... 90 C Temperature measurement Sensor measurement range 20...110 C Temperature differential 3...90 K Output signal under measuring conditions in test mode Behavior in the event of excessive flow flow rate = 2 q s flow rate > 2 q s Perm. ambient temperature Transport and storage Operation Battery life Connections and weight Pipe connection (inlet and outlet) Weight Temperature sensors Sensing element Connecting cable 0.6 m 3 /h 1.5 m 3 /h 2.5 m 3 /h 6 / 12 l/h 15 / 30 l/h 25 / 50 l/h 600 l/h 1,500 l/h 2,500 l/h 1,200 l/h 3,000 l/h 5,000 l/h 1.2 l/h 3 l/h 5 l/h 10 bar optional M-bus (EN 1434) optional M-bus (EN 1434) optional voltage pulses (DC 3 V) linear constant 5...55 C 55 C max. >8 years (>7 years for units with radiobased data transmission) 0.6 m 3 /h 1.5 m 3 /h 1.5 m 3 /h 2.5 m 3 /h ¾ ¾ ¾ 1 110 mm 80 mm 110 mm 130 mm 0.73 kg 0.65 kg 0.71 kg 0.8 kg Pt 500 Ω to EN 60751 1.5 or 2.5 m Pulse output (WF...24... ) Pulse output Open collector protection resistor 2440 Ω ±10 % Polarity reversal not possible Pulse length 100 ms Pulse pause 100 ms Max. voltage <30 V Current 0.1 ma Impedance to ground (water pipe) 10 nf (50 V) Pulse valency 1 kwh per pulse (heat energy) Advice The service tools ACC210, AZS210 and ABS210 can not be used with the pulse output meter! 7/10

90 5333M01 26 46 10 1500/2500 13,5 85 71,5 137 Dimensions R 74 79 90 360 19 12 G ¾ SW19 50 67 5 M 10x1 110 110 mm, direct immersion of sensor R 74 79 90 360 71,5 85 137 19 G ¾ 50 67 46 1500/2500 5 110 12 13,5 5333M02 110 mm, indirect immersion of sensor R 74 79 360 1500/2500 17 73 90 142 14 14 24,5 SW13 G1 50 67 46 10 26 5 M 10x1 130 5333M03 130 mm, direct immersion of sensor 8/10

90 R 74 79 360 1500/2500 17 90 73 142 14 14 24,5 G1 50 67 46 5 130 5333M04 130 mm, indirect immersion of sensor R 74 79 90 360 1500/2500 13,5 71,5 85 137 SW13 19 G ¾ 50 67 48 10 26 5 M 10x1 80 5333M05 80 mm, direct immersion of sensors 9/10

10/10 1999 Siemens Building Technologies Ltd. Subject to modification