Operating instructions FPCC FPFG FPCG FPFX FPAC

Similar documents
FPO 80 FPOC FPOS FPON, FPOS Tank truck vane pump

TruckFIT Vane pump with integrated multiple slide control

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Levelling valve

Medium and high pressure pumps

Dry installed pump type LANDY BTP.

Index. 4. Installation. 1. General advises

Index. 4. Installation. 1. General advises

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Starting up hydraulic systems

Axial Piston Variable Pump A2VK

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Vane pump, direct operated

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Feed Pumps Direct Drive Series 1.1.

Installation and Start-up Instruction. This instruction is valid for all standard low pressure pumps: LPD, ACD, ACE, ACG/UCG, ACF/UCF, LPQ and ABQ

Pneumatic Rotary Actuator Type 3278

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

original operating manual Operating manual Translation of the Item-No.: ,

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Pressure Reducing Valve Type 2114/2415

Suction Filters S8-455 SE56-560

Axial Piston Variable Pump A2VK

PACKING, HANDLING, TRANSPORTING AND STORING MOTORS

Operating Instructions

9/28/2018. Refrigeration compressor operation, maintenance and safety

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Feed Pumps VP / VPB / VPBM

A408 GB. Pneumatic oil and diesel pumps 1:1

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Operating Instruction

IPVS High-pressure Internal Gear Pumps Technical Data Sheet

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

PUMP SCPD 56/26 DIN BY-PASS

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve

Swing Piston Compressors and Vacuum Pumps

Instruction for RBP250-3 and RBP300-3

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Feed Pumps Direct Drive Series 1.1.

Installation and Operating Instructions

Axial Piston Variable Double Pump A8VO

Axial piston fixed pump A17FO Series 10

Operating and Maintenance Instructions. Abteilung TB, Schell Seite 1 8 SERIES 56

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Axial piston fixed pump A17FNO Series 10

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives Technical Data Sheet

2.4 HEAVY DUTY SERIES

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

Three Lobes Roots Blower. Instruction Manual

Single Sluice Gate Drive Type 1211/ / / ,5 1211/

Operating manual Separator

Axial Piston Fixed Pump A2FO

Axial piston fixed motor A2FM for explosive areas II 2G ck IIB Tx

SERIES PC INSTRUCTION AND OPERATION MANUAL

SERIES G3DB/AG3DB ELEVATOR

IPC Medium-Pressure Internal Gear Pumps Technical Data Sheet

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Operation & Maintenance Manual

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

Internal Gear Pumps Installation Manual

IPCA Medium-pressure Internal Gear Pumps Technical Data Sheet

Sealless Magnetic Coupled Multistage Centrifugal Pumps with Priming Stage Type HZSM / HZSMB / HZSMR / HZSMA / HZSMAR

Axial piston variable pump A4VG Series 40

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Axial Piston Fixed Pump A17FNO Series 10

Electric Immersion Pumps PXA and PXK, sealless

Performance-Gewindefahrwerke Performance Coilover Kits

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives

Mechanical seals external, single or double type Crane 58U 58U

Discharge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

GT-200 GATE VALVES PN16, Screwed end

Multiple disc brakes. pressure released and spring operated multiple disc brakes series LBD T brake. Installation- operating instructions

our contribution for environmental protection Sealless magnetic coupled centrifugal pumps acc. to EN Type NML / NMB

Flow direction is reversed by tilting the swash plate to the opposite side of the neutral or zero displacement position.

Vane pumps, direct controlled Type PV7...A

HPP06. Hydraulic Powerpack. HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

Operating Instructions for Elevator Buffers type LP

Clamping and drive module

Radial piston pump, fixed displacement

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Axial piston variable pump A4VG Series 40

Type 3320, Service Manual. Serviceanleitung Service Manuel

INSTALLATION AND OPERATING MANUAL Translation of the original manual. Series SCK. Mechanical Seal. double, to DIN EN Keep for future use!

AKG-A/AKGS-A. Type Series Booklet

Transcription:

Vane pumps Operating instructions FPCC 65 -... FPFG 65 -... Index Page Proper use 2 Type code 2 Technical data 3 Installation 3 Start-up 10 Maintenance 13 Trouble shooting 13 ALFONS HAAR MASCHINENBAU GMBH & CO. KG Postfach 530 160 D-22531 Hamburg FAX (49) 40 844 910 TEL (49) 40 833 91-0 Sales -183-144 -214 Service -164-229 -244 Spare parts -129 Repairs -137 INTERNET www.alfons-haar.de E-MAIL sales@alfons-haar.de Edition 12/2005 Subject to alteration!

Proper use People and material may be put at risk in the event of any deviation from the intended form of application. The limits contained in these instructions may not be exceeded. The vane pump is used to pump low-viscosity mineral oil products and non-corrosive and/or suspension-free liquids up to a viscosity of approx. 76 cst. It is suitable for installation for zone 1 according CD 1999/92/EG. Measures for explosion proofness These operating instructions describe the necessary measures for safe operation (e.g. prevention of excessive temperature, excessive run time of dry pumping). If this can not be assured, additional measures shall be taken (e.g. deactivation by temperature switch, safeguarding the connected systems by flame arrestors). Each modification of the vane pump and every alteration of the use, that was arranged at the sale, requires consultation with Alfons Haar. Type code Example: FP C C 65-289 Z R FP: Vane pump C: Housing design (dimensinal) C = with TW flanges according to DIN 28459 A = with flanges according to DIN 2501 F = for manifold ANST C: Shaft design (dimensional) C = free cylindrical drive shaft end G = as C, but other shaft end for additional drive for a hydraulic pump X = special shaft for slime line vari pump 65: Nominal bore of suction and discharge end 289: Theoretical delivery in litres/1000 revolutions or cm³/revolution (FP 65: 289, 343 or 407 cm³/revolution) Z: Special designs Z = Positive actuation of the vanes A 134 = version for solvents R: Directional rotation (viewed from the pump drive shaft) R = clockwise directional rotation, L = counterclockwise directional rotation R L = reversible 2 Operating instructions vane pumps

Technical data Flow rate: between 100 and 600 l/min Speed: n max = 1500 rpm n min = 600 rpm With positive actuation of vanes: n min = < 600 rpm Viscosity: ν max = 76 cst With pos. actuation: ν max = to approx. 50000 cst Delivery pressure p max = 0.7 MPa (= 7 bar) (depends on operating pressure of by-pass valve) Nominal pressure: p = 1 MPa (= 10 bar) Weight: m = 33 kg Temperature range: t = -25 C to + 70 C Installation Danger - Do not place hands etc. into the vane pump openings! Preparation Remove all transport packaging. Check the pump for external transport damage. Check that the pump functions correctly by manually turning the pump shaft. (It should be possible to hear all 12 vanes falling). Location Install the pump tension-free and horizontally. The shaft may deviate by up to 5 from the horizontal. The drain holes in the pump cover must always face downwards so that no moisture can accumulate. The pump shall be installed upright, fixed on its base. If this is not possible, please contact Alfons Haar for advice. Leave adequate space for service and maintenance access. The housing cover opposite the drive unit must be accessible. Operating instructions vane pumps 3

Fastening If possible, the vane pump and drive motor should be mounted on a base plate. The connection between the pump and the drive motor is made using a shock-absorbent coupling (base plate version). To prevent vibration, it is advisable to attach the pump unit using shock-absorbent elastic mounts. Set of elastic mounts (4 pcs.) Alternatively, the pump can be attached to, for example, an electric motor using a coupling (flanged version). For propshaft drive the mounting is made in the vehicle chassis. (for use in tank truck). Dimensions # # "! # & # & & " $ $ & # % # & & $ # ", 5 2 DIN = BA 6885 @ A H = feather? D, 1 $ key & & # 4 " " #! # ' %!! " # " & # Illustrated: Vane pump FPCC 65 -... with pneumatic by-pass valve type PÜVA 65 E 4 Operating instructions vane pumps

Ø11,5 154 130 228 125 58 208 Ø18 185 145 125 228 66 208 65 122 DIN 2401 flange Paßfeder DIN 6885 nach feather DIN key 6885 299 18 R 1/4" D S Ø24 j6 102 120 207 14 Ø24 j6 88 106 185 65 14 D S DIN Paßfeder 6885 nach feather DIN 6885 key 277 R 1/4" 14 50 100 Ø13 125 197 334 25 X 150 140 180 210 250 Illustrated: Vane pump FPCG 65 -... with pneumatic by-pass valve type PÜVA 65 E (and hydraulic pump ZFS 0/... with drive connection G-FP50/FP65) 50 100 Ø13 125 197 334 150 140 180 210 260 Illustrated: Vane pump with pneumatic by-pass valve type PÜVA 65 E Operating instructions vane pumps 5

" $ & $ " ' $! %! " &! $ " ' & DIN 6885 2 = BA @ A H =? D, feather 1 $ & & key # # $ " ' M12, 21 deep JEA B # : # # space for service ' % # ' Illustrated: Vane pump FPFG 65 -... with pipe connector and pneumatic bypass valve type PÜVA 65 E (and hydraulic pump ZFS 0/... with drive connection G-FP50/FP65) 6 Operating instructions vane pumps

Pipeline connection If mineral oils of hazard class AI or AII are being pumped, and depending on operating conditions, anti-explosion devices must be fitted in the suction line. See chapter Proper use. The pipelines should be attached using flexible pipe connectors. A filter (mesh size < 1000 µm) must be installed to protect the pump against mechanical damage caused at the suction end by foreign bodies. Pump accessories (order separately): - Mechanical or pneumatic by-pass valve - Pipe connector - Hydraulic pump with drive connection - Bi-directional by-pass valve for reversible pump operations - Pump strainer - Adapter for by-pass return - Adapter flange - Anti-explosion device - Dry operation protection (thermostat and intermediate plate) - Pressure gauge for suction and discharge - Vacuum controller - Starting aid star/delta electric motor - Starting aid (e.g. for diesel engine drive) - Mechanical by-pass control - Elastic mounts - Lubrication line extension The suction line must be as short and as straight as possible and have a sufficient nominal width. To avoid cavitation, the line should be sized in accordance with NSPH calculations. The discharge line is to be installed in such a way that it is vented when the pump starts up. The suction line must be prevented from running dry if venting before each commissioning is not envisaged on the discharge side. For safety reasons, the vane pump must only be used if it has a permanently mounted by-pass valve or a relief valve that has been integrated in the system. It must be ensured that this valve is assembled correctly. The suction and discharge line must be connected to the pump according to the directional rotation of the drive. Operating instructions vane pumps 7

Vane pumps supplied with by-pass valves have a S for suction and a D for discharge embossed on the by-pass valve. The suction end of the by-pass valve is indicated by an S and must correspond to the pump's suction end. Mechanical by-pass valve type ÜVA, ÜVB Pneumatic by-pass valve type PÜVA, PÜVB, 5 Discharge end Suction end Mechanical by-pass valve type ÜVFE, ÜVKE Pneumatic by-pass valve type PDÜVF, PDÜVK Designation S Discharge end Suction end Pipe connector with by-pass valve mechanical, type ÜVA pneumatic, type PÜVA Discharge end Suction end 8 Operating instructions vane pumps

Assembly at inaccessible locations Locate the pump's lubrication points to allow safe maintenance. Lubrication line extension, part no. 1017442 * * * Discharge of excess lubrication Preventing overheating Allowing the pump to run for a relatively long period (> 5 min) against the closed discharge end will cause overheating. To prevent overheating, a product line (8x1) can be led back to the tank or a dry operation protection device should be fitted to the pump (see pump accessories). Prop shaft drive (for use in tankers) α Abtrieb Drive Antrieb Drive α Parallel parallel Do not use force when fitting the coupling halves and articulatedshaft flange to the pump shaft (use lubricant and a rubber mallet). In the case of prop shaft drives, follow the manufacturer's instructions and do not exceed the specified angle of inclination α. The drive flanges must be parallel. No thrust should be transmitted from the drive to the pump shaft. If the pump is being driven via a vehicle engine, make sure that the pump is switched off when the vehicles is in motion. Operating instructions vane pumps 9

Temperature monitoring Pressure monitoring The maximum permissible temperature is 70 C. A temperature monitoring system should be fitted (e.g. dry operation protection) if there is any danger of exceeding this value. To allow the pump to be set and monitored, a pressure gauge should be installed at the discharge end and a vacuum meter at the suction end. Pressure gauge -1 to 9 bar Pressure gauge 0 to 10 bar Suction end Discharge end Start-up Checking the direction of rotation Failure to observe these guidelines may cause injury to personnel and damage to property! Allowing the pump to run dry will cause overheating. Assure correct direction of rotation by checking the markings on the by-pass valve: S for suction, D for discharge. To change the direction of rotation of the pump, turn the by-pass valve on the pump through 180 and, in the case of types FP...R or L, turn the pump-impeller vanes through 180 before inserting them in the rotor. In the case of the FP...RL, the pump-impeller vanes do not need to be turned. When using a mechanical by-pass control, this has to be turned in a clockwise direction up to the stop. After the pump has been started, the mechanical by-pass control has to be turned out. Initial start-up Start the pump only when there is sufficient pumping medium available. Maximum dry pumping time is 5 minutes. The pressure line should be vented when the pump starts up if required. 10 Operating instructions vane pumps

Setting the operating pressure In the case of complete units, the by-pass valve is already fitted to the pump and set in the factory to the required operating pressure. The operating pressure can be modified within the range of values specified on the type plate. In the case of mechanical by-pass valves, this is achieved by turning the shaft end (this changes the tension on the spring). On pneumatic by-pass valves, the pneumatic pressure must be changed. A B Shaft end or pneum. connection Type plate A B Direction A = Reduction in pressure Direction B = Increase in pressure If the operating pressure is increased (by increase of by-pass pressure), the required shaft power should be determined from the pump characteristic curve and compared against the drive output in order to avoid overload. If the customer has to adjust the operating pressure of the bypass valve, a pressure gauge and stopcock must be fitted on the discharge end. Slowly closing the stopcock while observing the pressure indicated on the pressure gauge enables the selected operating pressure to be checked. (recommended value: operating pressure = required delivery pressure + 0.5 bar) If the pressure exceeds the permissible value or the operating pressure is not achieved, the by-pass valve setting must be corrected. Operating instructions vane pumps 11

Pressure gauge Shut-off valve on discharge end The shut-off valve must be reopened. If the gauge shows a higher value than the predetermined by-pass pressure the spindel should be turned counter clockwise (direction A). If the gauge shows a lower value than the predetermined by-pass pressure the spindel should be turned clockwise (direction B). To control correct adjustment close the shut-off valve slowly. The procedure is to be repeated until correct adjustment. Note down the setting. Open the shut-off valve. In the case of pneumatic by-pass valves, the pressure applied to the by-pass valve is reduced or increased accordingly. A pressure regulating valve must therefore be installed in the pneumatic line (recommended value for the ratio between air pressure and operating pressure approx. 1:1.3). 12 Operating instructions vane pumps

Maintenance Lubrication Intervals Lubricant Procedure Central lubrication The vane-type pump is to be lubricated at the bearing positions. Every 600 operating hours or 3 years, whatever happens earlier. For standard operations: Beacon EP2 (part no. 1000189). For low temperature operations (e.g. for type X1): Molyduval Aero 14 (part no. 2067578). Apply lubrication to the lubricating points during pump is running (without load, min. 300 rpm) until the grease is discharged at the exit points. Danger - Be careful for running pumps! This is permitted providing a suitable lubricant is used. Troubleshooting Fault Pump does not draw/ Pump becomes louder The hydr. by-pass valve installed in the hydr. system by-passes Pump makes knocking sound and its performance is reduced Pump pressure too high Pump pressure too low/ no pump pressure Cause Filter blocked Pump excessively worn (high gap leakage) By-pass valve incorrectly installed By-pass valve set too high Vanes broken By-pass valve incorrectly installed By-pass valve set too high Seal between by-pass valve and pump missing or fitted incorrectly Rotational speed too low Remedy Clean filter Consult Service dept. Change vanes if necessary Turn by-pass valve Check by-pass valve setting, adjust if necessary Consult Service dept. Check pump filter for damage Turn by-pass valve Check by-pass valve setting, adjust if necessary Check seals, replace if necessary Increase rotational speed (n max ) Operating instructions vane pumps 13