Hydraulic power unit CE8L Technical data

Similar documents
Chandrashekar.p. Electrical and Electronics Engineering, PESITM-Shivamogga, Karnataka-India

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SIME BRAKES INDUSTRIAL BRAKING SYSTEMS

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL

2/2 or 3/2 way direct acting rocker solenoid valve

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Dosing pump series G A

VTZ variable speed Reciprocating compressors

Steering column and sensor

D e s c r i p t i o n

Thermal-magnetic Miniature Circuit Breaker 4230-T...

ProMinent Beta Solenoid Diaphragm Metering Pumps

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

SOLSTART Instruction Manual

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

3/2-5/2 ports / positions

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

Variable speed application guidelines

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Lenze. Drives with worm gearboxes 52.

EPN/EPNCR Applications. Features

EVI 5 S13 Solenoid System

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

DATASHEET 16 Mar 2016

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

0322, 0324, Pilot Solenoid Valve, Plastic

ARBO. ARBO Magnetic drive pumps. Pompen en Filters b.v. Product group 2.2

- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO

HYDRAULIC GROUPS 1.1KW 1~ / 6.1CC. Article Code: 1GH008

COILS AND CONNECTORS. Atlantic Fluid Tech SECTION 21. Rev. 10/ Connector Page class

In line high pressure filters. HF 735 series

Gauges, Sight Glasses and Vacuum Breakers

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

MT/MTZ 50 Hz R22 R407C R134a R404A / R507

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Off-Line Filter BNF. FluidControl

Phoenix Inverter

CIRCOGRAPH Sensor systems Rotating Head Ro 35 P Rotating Head Ro 35 L

EMO TM. Actuators High performance proportional actuator For modulating control

SDC,Inc. SCR-Regenerative Ac Drive

G4 Diesel Fuel Shut off Valve A very safe method to protect YOUR engine

Clamping and drive module

Technical Documentation Radial Pump with Canned Motor Y-1638-MM

Introduction. Pressure drops

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

FSP Fan Speed Power Module Technical Data

Technical Documentation Regenerative Turbine Pump with Canned Motor Y-2951-W-MM

Solenoid System FLANGE MOUNTING VERSION

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

FLUID TRANSFER SECTION 1

RVS-AX Instruction Manual

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

THE IMPORTANCE OF AN EFFICIENT FILTRATION

ST Wiring diagram. Product description. Temperature controller. Order number

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Seated valves 500 bar

Position switches FR series

J3C-L Nm Smart Electric Valve Actuator Failsafe Function Type: J3C Model: L140-BSR

SOLENOID VALVES AND PNEUMATIC VALVES

FA + solenoid valve Type ICF 15/20 EVRAT

Position switches FR series

In line high pressure filters. HF 725 series

W22 Brake Motor Three-phase Electric Motor

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303

MINIATURE CIRCUIT BREAKER

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

CB to 1000 A. 1 to 4 single pin main poles with silver pad contacts.

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

HIGH POWER SOLENOID DRIVER 1

Technical brochure Electrically operated expansion valves, type ETS 6

BATTERY CHARGERS.

Flow Meter Terminal Boxes

Control Relays Overview

Electric expansion valves Type ETS 6

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 855 / 0817 / E

FA 016 FAPC 016. Oil Service Units. Description. Page 53

Industrial Pressure Transmitter

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

4 pole insulated conductor rails ULA 35A, 50A, 80A, 100A

Position switches FC series

Off-line filter / cooler unit BKF

VE-S_15-32 Pressure Independent Balancing & Control Valves

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

SIE BV/ED EVS. SINGLE HEAD PUMPS IN-LINE ELECTRONIC CONTROL Heating - Air conditioning S.H.W. 50 et 60 Hz. operating limits SIE BV/ED

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

16mm miniature rocker solenoid valve with isolating diaphragm for special applications

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Transcription:

Hydraulic power unit CE8L 26/02/15 1/10

1 - PRESENTATION 1-1 Use The hydraulic power unit CE8L (fig.1) is intended to deliver an hydraulic pressure to open the emergency hydraulic brakes SH and TH. Fig. 1 1-2 Operating conditions Working conditions: - Ambient temperature: -10 C to +60 C - Relative humidity 70 % - Dust in atmosphere 65 µ - Protection against vertically falling waters. Other conditions, consult Stromag France. 2 - OPERATION 2-1 Flow diagram See fig. 5. 2-2 Principle (fig. 5) a) Opening of the calipers 1-2 General characteristics The CE8L hydraulic power unit is fitted with a gear pump and a motor of 2,2 kw at 1500 rpm for a nominal flow rate of 8,4 l/mn (on network 50 Hz). The maximal utilization pressure is 225 bar. Frequency of operations = 100 operations / hour maximum The caliper can be installed horizontally (CE8L-H) or vertically (CE8L-V) (reservoir at the bottom). See flow diagram fig.5 and description fig.6. Calipers are closed by means of a single solenoid valve EV1 (NO). For installations requiring a high level of safety, we advise the option OP1 (2 EV). In additional, we recommend a device of permanent diagnosis of the solenoid valves operation (CS2EV) which allows the detection of a possible fault. When the hydraulic power unit is switched on, the solenoid valve EV1 (NO) closes and the motor M starts simultaneously. This motor drives the gear pump P1 which gives the oil pressure allowing the hydraulic calipers to open. The opening of the pressure switch CP1, included in the working circuit, stops the motor M when working pressure reaches the maximum set level. Then, the installation stays under pressure with the motor M stopped. If pressure lowers down to the minimum level, the switch closes and starts the pump motor M again. b) Closing of the calipers and braking Switching off the motor M and the solenoid valve EV1 brings the oil back to the power unit reservoir and the pressure back to zero. Calipers close and braking torque is applied. c) Manual opening of the calipers With the flow limiter LD1 closed, the hand pump P2 provides the necessary pressure to open the calipers, in case of mains failure or manual operations on the calipers. 26/02/15 2/10

2-3 Options Options of the CE8L power unit are described in the "Options" leaflet quoted in the bottom of the page. Table 1 below sums up all these options : Options Description Comments MS Motor 290/500VAC 50Hz or Motor 230/400 VAC with PTC sensor Other voltages, consult us. EVS EV coils voltage different from the standard K1 K2 Electrical power unit integrated to the hydraulic power unit, Input voltage 400V 3 phases 50 Hz. + 230V single phase 50 Hz Electrical power unit integrated to the hydraulic power unit, Input voltage 400V 3 phases 50 Hz. For CE8L standard and CE8L OP1. For the other voltages (MS and EVS), consult us. OP1 Enhanced security return circuit by 2 solenoid valves. - Noncumulable options with option Y5. - For monitoring device of the 2 EV OP1-OP2 Manual lowering with a dead man safety device. (CS2EV), conult us (APS). - To equip the hydraulic unit CE8L-OP1-OP3 OP1-OP3 Manual lowering with overspeed safety by solenoid valve 24VDC. with an electrical unit, consult us (APS). CS2EV Y5 OP4 Monitoring device of the 2 solenoid valves EV1 and EV2, consult us. The hydraulic unit is fitted with a proportional pressure limit valve for a regulated braking or the lowering of the load. The function of braking on/off is kept. Indicator switch of the position of the main control valve and of the lowering control valve (if option OP2 or OP3) For CE8L-OP1, CE8L-OP1-OP2, and CE8L-OP1-OP3. - Non cumulable option with options OP1, OP2 et OP3. - This option requires a specific electrical unit according to the control system (lowering of the load, constant deceleration, etc..), consult us (APS). - R option enables to limit the full braking torque, consult us (APS). OP5 Visual or electrical clogging Indicator OP6 Hydraulic unit for "iron and steel industry" with: 2 oil level sight glasses in pyrex no ventilation on the motor This option enables to work in atmospheres with high concentration of dust and at ambient temperature of 60 C in continuous (90 C at the peak < 2 minutes 6 times per hour maximum). OP8 Electrical indicator of the oil level in the reservoir OP10 Drip tray for hydraulic unit mounted horizontally For CE8L-V (vertical) hydraulic unit, CE8L-K1 and CE8L-K2, consult us RV Drain valve for reservoir 26/02/15 3/10

Options available requiring an adaptation (APS) : Options Description Remarques Z1 At the time of a braking order or a voltage failure, Z1 option allows a delay of caliper closing by maintaining a voltage on the coil of the solenoidvalve. (delay of 0,1 to 1,2 second). Option with specific K2 electrical unit. APS obligatory. Consult us. Z2 At the time of a braking order or a voltage failure, Z1 option allows a delay of caliper closing by maintaining a voltage on the coil of the solenoidvalve. (delay of 0,1 to 20 seconds). Option with specific K2 electrical unit. APS obligatory. Consult us. OP7 Thermostat 80 for the reservoir Consult us. 26/02/15 4/10

3 - CHARACTERISTICS 3-1 Designation a) Power unit (table 2) CE8L - XX - X - XX - voltage- frequency Unit type Example: Pressure switch setting Position H : horizontal V : vertical Options CE8L-20-V-OP6: hydraulic power unit CE8L with the maximum of the pressure limit switch set to 200 bar, fitted for a vertical mounting and steel plant environment. b) Calipers (table 2) SH15 - X Caliper type Example: SH15-3 Table 2 Braking force code Power unit type Calipers types Main limit valve LP Limit switch CP1 SH25 SH18 SH18B SH15 SH9 SH6 SH5 TH9 SHM10 mini/maxi Hand pump limit valve LP1 CE8L - 20 SH25-2 SH18-2 SH18B -- SH9-3 -- SH5-6 -- -- 225 180 / 200 250 CE8L - 18 -- -- -- SH15-3 SH9-2 SH6-3 -- -- -- 205 150 / 180 230 CE8L - 16 SH25-1 -- -- SH15-2 -- -- SH5-5 TH9-3 -- 205 140 / 160 230 CE8L - 14 -- SH18-1 -- SH15-1 SH9-1 SH6-2 SH5-4 -- -- 165 110 / 140 180 CE8L - 11 -- SH18-0 -- -- -- SH6-1 SH5-3 TH9-2 -- 140 85 / 115 160 CE8L - 07 -- -- -- -- -- -- -- -- SHM10 90 55 / 75 100 The maximum number of calipers associated with the CE8L hydraulic unit is in the leaflet "Connection of a hydraulic unit" quoted below. Example: calipers SH15-3 are related to the supply unit CE8L-18. All the values LP, LP1 and CP1 are pressures given in bar. 26/02/15 5/10

3-2 Dimensions See fig.4. 3-3 Hydraulic characteristics a) Calipers associated See table 2. b) Mineral oil A mineral oil must be imperatively used. Characteristics conform to the standard ISO 6743/4. Choose a type in accordance with the temperatures of utilization. Grade L-HM or L-HV. Avoid to mix oils of types HM and HV. For oils with other characteristics, consult us. Refer to the leaflet "Oils" quoted in the bottom of the page. b) Solenoid valve EV1 Coil under 230 V RAC ± 10%, 50 or 60 Hz single phase with a rectifier bridge in the connector (20 W). Other optional voltages, option EVS: 48, 110 V RAC, 50 or 60 Hz - 24 V DC c) Pressure limit switch CP1 - Single-pole and snap-acting contact "OC" - Protection: IP 66-240 V AC, 1,5 A - 250 V DC, 0,1 A The reservoir capacity is : Horizontal or vertical installation : - High level = 8 litres - Low level = 6 litres 3-4 Electrical characteristics a) Motor M 3 phase: 230/400 VAC 50 Hz 2.2 kw, 4 poles Protection IP 55 class F Aluminium body, metallic terminal box, brass cable gland Other 3 phase voltage on option MS : 290/500VAC 50Hz 230/400VAC 50Hz with PTC sensor To specify according to table 3. Table 3 Mains 3 phases Motor /Y Frequency 50 Hz 230/400VAC 50Hz STD 220-230-240VAC ±10% 50Hz 230/400VAC 50Hz + PTC MS 230/400VAC 50Hz Y STD 380-400-415VAC ±10% 50Hz 230/400VAC 50Hz Y + PTC MS 440VAC ±10% 50Hz 255/440VAC 50Hz Y APS 500-525VAC ±10% 50Hz 290/500VAC 50Hz Y MS 660-690VAC ±10% 50Hz 400/690VVAC 50Hz Y APS Frequency 60 Hz 220-230-240VAC ±10% 60Hz 230/400VAC 60Hz APS 265-277-290VAC ±10% 60Hz 230/400VAC 50Hz STD 380-400-415VAC ±10% 60Hz 230/400VAC 60Hz Y APS 440-460-480VAC ±10% 60Hz 230/400VAC 50Hz Y STD 575-600VAC ±10% 60Hz 290/500VAC 50Hz Y MS STD = standard / MS = option / APS = adaptation, consult us. 26/02/15 6/10

d) Wiring examples (fig. 2 and 3) The whole wiring connections are to be realised by the customer following examples fig. 2 and 3. Fig. 2 3 phase mains + T Single phase supply Fig. 3 3 phase mains + T 1 2 3 7 8 1 2 3 F1 F1 0V T1 230V F2 KM1 I> I> I> 4 5 6 H1 B1 13 14 9 10 KF P x 1 KM1 Braking / release control 11 12 EV1 KM1 I> I> I> 4 5 6 0V H1 B1 13 Braking / KF release control 14 9 10 P x 1 KM1 EV1 11 12 M 3 Pressure limit switch CP1 M 3 Pressure limit switch CP1 Motor M Motor M provided by Stromag France provided by Stromag France On option, an electrical control system K1 (fig. 2) or K2 (fig. 3) is mounted integral with the hydraulic unit to simplify the customer wiring. The customer supplies the alternative current and braking/release control (KF). See "Options" leaflet quoted below 26/02/15 7/10

Fig.4 - Dimensions 478 830 40 50 200 37,5 110 37,5 695 4 holes Ø9 332 Weight : 54 kg without oil Representation: CE8L-H (horizontal position) 26/02/15 8/10

Fig. 5 - Flow diagram of the hydraulic power unit 1G Caliper Caliper CP1 1Q Power unit PP LD1 CA4 CA1 LP1 EV1 CA3 CA5 Hand pump P2 CA2 LP F BR1 M P1 CR R BV Components: BR1 BV CA1 CA2 CA3 CA4 CA5 CP1 CR EV1 F Filling port Draining port 1/4"G Check valve Check valve Hand pump check valve Hand pump check valve Check valve Pressure switch Suction strainer Solenoid valve Filter LD1 LP LP1 M P1 P2 PP R 1G 1Q Flow limiter Main pressure limit valve Hand pump pressure limit valve Electrical motor Gear pump Hand pump Pressure port Reservoir Manometer Isolation cock of the manometer 26/02/15 9/10

Fig. 6 - Components of the hydraulic unit CE8L standard (shown in horizontal version) Pressure switch CP1 Manometer 1G High level sight glass Isolation cock 1Q Low level sight glass Filling port BR1 (breather replaced by a tight plug for option OP6) Draining port 1/4"G (BV) Output 1/2"G Hand pump P2 Reservoir R Motor M Filter F LP Hand pump lever Pressure port PP Solenoid valve EV1 Flow limiter LD1 Pressure limit valve LP1 Pressure port PP Main pressure limit valve LP Hand pump P2 26/02/15 10/10