SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

Similar documents
Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

SPECIFICATIONS FOR HYDRAULIC PTO DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

Darley UHP-HV Diesel Specification 1

PyroLance B 2000 M-G Technical Manual

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

Car Wash / Pressure Washer

B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank

OPTIONS SLIP-ON FIREFIGHTING UNITS

PRODUCT RELEASE CKMTA12 / 24

FOR YOUR SKID SPRAYER?

HIGH VELOCITY PUMP PUMP END

HOT WATER PRESSURE WASHER BREAKDOWN

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

M-B Companies, Inc. Specification. Model 155 PLS-155. Palletized Striper. High Pressure Airless. 2 x 55 Gallon Drum. Standard Rev. 2 January 11, 2008

B Pump Mounting. Page 1 of 7

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

PARTS LIST FOR CW ME3 (AFTER SERIAL # )

05 Water Pressure Systems INTRODUCTION

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Portable Pumps Transportable MaxStream Diesel Floating Pumps Pro Kit Skid and Trailer

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

2 YEAR WARRANTY HOSE REELS. reelmaster Series heavy duty, quality hose reel engineered to save space

Fog Misting System. Misting systems have been used in outdoor cooling applications for decades. These systems can provide outdoor cooling

3.2 UTLI41A AND UTLI46A GENERAL SPECIFICATIONS

CW ME1/3 CW ME1/3 CW ME3:

Solenoid Operated Block Valves A2800 Series

MODEL NO. TSSK GALLON SKID-MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

Cartridge Valves Technical Information. Spreader Valves. Spreader Valves SCHEMATIC MODEL PRESSURE FLOW* WEIGHT SPR-2FFL12 SPR-2FFLC12 SPR-2FFLW86

PARTS LIST FOR CM MEH. Copyright 2015, Mi-T-M Corporation

PARTS LIST FOR CM MEH (AFTER SERIAL # ) Copyright 2007, Mi-T-M Corporation

Complete Systems & Parts Automatic Oiler & Grease Bank MADE IN THE USA

Custom Vac 822 Hydrovac with the following specifications (Tri Drive Mounted):

32 quarts Transmission Allison HT 740 Automatic Fluid

HIGH PRESSURE SPRAYERS

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

MODEL: PX10-200ET70 / PX15-280ET140

DARLEY PUMPS CAF SYSTEMS DAVEY PORTABLES DIESEL PORTABLE FAST ATTACK SKIDS

Introduction. General Information. Systems Operation

Spreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86

FIRE KNAPSACK FIRE RESPONSE UNITS FIRE TRAILERS. Fire Fighting. Pages Designed to perform better.

CM MHC CM MHC CM MKC CM MMC

UNIVERSAL, INDEPENDENT DUAL SYSTEM HYDRAULIC TEST STAND

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

Priming Systems Installation Instructions

PARTS LIST FOR 4004 SERIES PORTABLE/ALUMINUM GASOLINE DRIVEN/BELT DRIVE COLD WATER PRESSURE WASHER

THE JOB PRO PARTS LIST FOR JP-1002/1502-0ME1. Motor Horsepower: Nozzle Size: Copyright 2003, Mi-T-M Corporation

CW-2004-SME3: PARTS LIST FOR (AFTER SERIAL # ) Motor Horsepower: Pump Oil Capacity: Nozzle Size: CW-2004-SME3: 5.5

PUMPERS CUSTOM AND COMMERCIAL. Discover Innovation. Experience Technology.

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

M-B Companies, Inc. Specification. Model 155. High Pressure Palletized Striper. High Pressure Airless. Options REV. 2.

The TR-Series are large volume,

DIAMOND CONCRETE SAW PARTS LIST MODEL CC8000 P R O D U C T S. (Revised )

SECTION D Engine 6.0L Diesel

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

OPERATOR S MANUAL. To locate your local Kärcher Commercial Pressure Washer Dealer nearest you visit

MODEL NO. UTL-60-7

AIR COMPRESSORS.

Model: SK-61-4R 60 Gallon Skid Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

AccuMax 3060 Multi-Point Detailed Specifications

REPAIR MANUAL AFX8010

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

PARTS LIST FOR CA E2G CA E2G-W. Pump Oil Capacity: Nozzle Size: 4.0

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Model &

ERWC RM Shown with Optional Akron Brass Junction Box and Guide Roller

PARTS LIST FOR CA MHB/RB (AFTER SERIAL # ) CA MVB

PARTS LIST FOR CA MHB (AFTER SERIAL # ) Engine Oil Grade: SAE 10W-30 Engine Oil Capacity: 37 oz.

5 15 HP QUIET ENCLOSED RECIPROCATING AIR COMPRESSORS. Paradigm

NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES

NOZZLES NOZZLES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE TURBOJET NOZZLES NEW LOW PRICE

LIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS

PARTS LIST FOR CBA MHB (AFTER SERIAL # ) CBA MVB

Table of Contents WARRANTY

Page 6-6. Page 6-3. Page 6-3. Page 6-5. Self- Educting Foam. Foam Compatible. Location

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD


PARTS LIST FOR GC-1002/1502-0ME1 (GRAINGER ITEM #3WB86 AND #3WB87) COLD WATER PRESSURE WASHER (AFTER SERIAL # )

MITSA INTERNATIONAL P.O.

Darley Fire Storm Nozzle

ALAMO INDUSTRIAL Specifications Versa Series, 17 Mid-Mount Articulated Boom

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

5200 ITH Specifications and Features

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised

NOZZLES NOZZLES SPECIALTY SABERJET NOZZLES THE FIRST TRULY MULTI-PURPOSE NOZZLE

Transcription:

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A firefighting system shall be provided for offensively attacking a fire. The high pressure firefighting system shall allow the operator to attack fire from a safe position. The system shall be extremely effective on wildland fire and initial fire attack operations with limited water supplies. Components and Base Plate Design The firefighting system shall consist of: Engine: PTO driven ( PTO supplied by fire truck OEM) Water pump: High pressure positive displacement piston pump Hose Reel: Ultra-high pressure hose reel and attack hose Nozzle: Manually operated ultra-high pressure pistol grip style fog nozzle The major components shall be assembled on a removable assembly with integral hydraulic motor. The entire system shall be designed to be a quickly installed or removable plug-and-play module. Safety and Standards Compliance The system shall be designed for the safety of the operator and fire fighter in mind with a safety margin of 4:1 built into all components. 6140 S Gun Club Road, Ste. K6-270 Aurora, Colorado 80016 USA +1 (303) 952.5018 +1 (303) 474.3104 www.pyrolance.com

Performance Capabilities The firefighting system shall be tested and proven to be highly effective in the following scenarios: Wildland, grass, and brush fire applications Automobile and truck fires Limited structural fires Confined or concealed space fires Limited industrial fires Shipboard and marine firefighting Military firefighting applications Container fires BASE FRAME MOUNTING The firefighting system shall be mounted in a frame assembly. The mounting assembly shall be powder coated and shall be designed to contain the specified major components of the system. ULTRA HIGH PRESSURE FIRE PUMP SPECIFICATIONS The firefighting system shall be equipped with a heavy duty ultra high pressure three plunger type positive displacement fire pump. The pump shall be driven as specified under the drive system section of these specifications. The pump shall have the following features: Pump rating: 20 GPM @ 2,200 PSI (80 LPM @ 150 bar) Operational rating: 20 GPM @ 1,450 PSI (80 LPM @ 100 bar) Solid Keyed Shaft Brass Manifold Stainless Steel Check Valve Stainless Steel Plunger Guides Bronze Connecting Rods Tapered Roller Bearings Solid Ceramic Plungers Heavy Duty Flat Base High Pressure Seals Heat Treated Crankshaft. REXROTH HYDRAULIC DRIVE SYSTEM SPECIFICATIONS Once the PTO is activated on the pump control panel via the master PTO switch the variable speed hydraulic drive motor is controlled via an pressure compensating flow control switch which will activate when water flow in the fire pump circuit is sensed and allow the variable speed hydraulic drive pump to spool up to maximum flow regardless of engine RPM. Once the flow condition in the water circuit is stopped it will send a return signal via the pressure sensor flow control switch which in turn will put the pump into standby mode that will allow the pump to flow 1 GPM @2400PSI until the situation is reversed. As soon as the demand on the fire pump is replaced the hydraulic drive motor will spool up and pump 28GPM@2400PSI regardless of engine RMP. 2

Once the PyroLance PTO system is engaged and master/emergency stop switch is activated on the PyroLance control panel the system is active until either the PTO is disengaged or the E-Stop button is depressed. The system shall: a.) Reduce engine RPM when the pump is in by-pass resulting in reduced engine wear. b.) Prolong pump life by reducing potential heat build-up while the pump is in by-pass. c.) Reduce fuel consumption because the engine is not continually running at full RPM. d.) Allow the PyroLance system to be shut down in case of emergency by activating the Master/Emergency stop switch. e.) Allow rapid on/off throttle response eliminating pressure control delays when the PyroLance system is in operation. Hydraulic drive pump flow requirement shall be 28GPM@2400PSI and consist of the following: Hydraulic Pump Hydraulic Motor 40 gallon (152 L) Hydraulic Reservoir Hydraulic Cooler Thermostat PTO (Supplied by OEM0 The system shall be capable of delivering full rated output at 925 engine rpm. The system shall be compatible with a PTO with the following specifications: 1.3 step up ratio. 1.25 14 Tooth Splined Shaft Left Hand Rotation 2 Bolt C Mount INSTRUCTIONS AND LABELING A fire fighting pump instruction nameplate and necessary warning labels shall be installed on the assembly (English language). PANEL LIGHT The pump control panel shall be provided with an LED 12 volt light with switch. PUMP CONTROL PANEL The control panel shall be ergonomically designed and operator friendly. The panel shall be labeled and installed to be easily visible from the operator s position. The following instruments and controls shall be installed: Emergency Stop/Master Switch (red) PTO engagement switch Control panel light and switch One (1) pressure gauge Tank to pump open/closed switch 3

PLUMBING The firefighting system shall be plumbed with high pressure hydraulic type hose, plumbing and fittings. This shall include double wire braided high pressure hoses of various sizes, zinc plated steel hose ends, and plated steel hydraulic fittings. The threads shall be male and female NPT, JIC, SAE O-ring style in various sizes. Rigid plumbing shall be in zinc plated steel piping with pipe fittings of zinc plated steel. BYPASS UNLOADER VALVE The ultra-high pressure plumbing system shall include a bronze adjustable by-pass unloading valve set for the maximum working pressure of the system. The valve shall unload the main pump to the intake side of the pump. PRESSURE SAFETY, EASY START, THERMAL RELIEF VALVE The ultra-high pressure plumbing system shall include the following devices: f.) One (1) pressure safety relief valve which shall relieve water pressure to atmosphere; set at a slightly higher pressure than the unloading valve. g.) One (1) thermal relief valve which shall open if water temperatures exceed 145 F (62 C) degrees; designed to protect the pump from high temperature conditions and relieve the water to atmosphere. h.) One (1) EZ start valve. INTAKE FILTER A 1-1/4" (31 mm) water filter with 32 mesh stainless steel screen shall be installed in the water supply line to the fire pump. The filter shall be accessible for cleaning the screen. ELECTRICAL WIRING Necessary low voltage automatic circuit breaker protection shall be provided where required. Wiring shall be stranded copper automotive type, sized for the appropriate electrical load. Exposed wiring shall be protected with convoluted split plastic loom; such looms shall be mechanically secured. Wiring shall be run in protected areas or enclosed in metal panels where subject to mechanical injury. Electrical connections and termination of wiring shall be within weather proof plastic enclosures with waterproof strain reliefs and connectors. WATER TANK SUPPLY LINE A 1.25" (31 mm) water tank to fire pump line shall be installed as follows: From the fire pump to the water filter shall be a 1.25 (31 mm) flexible transparent hose. 15' (5 m) of 1.25 (31 mm) flexible water hose with removable connections and clamping devices. One (1) 1.25 (31 mm) manual two way tank to pump control valve. DISCHARGE PRESSURE GAUGE One (1) 2.5 (62 mm) liquid filled pressure gauge shall be installed from the discharge side of the ultrahigh pressure fire pump, with the gauge mounted on the pump panel. 4

ELECTRIC REWIND HOSE REEL ULTRA-HIGH PRESSURE One (1) painted ultra-high pressure steel hose reel shall be installed. The reel shall have a leak proof ball bearing swing joint, electric 12 volt rewind provisions. The reel system shall have a minimum of 4:1 safety ratio and designed for a 2,000 PSI (135 bar) working pressure. Each reel shall be equipped with a locking pin assembly. One (1) push button electric rewind control shall be installed near the reel. The wiring from the hose reel electric box shall be protected with conduit or loom. The hose reel shall be equipped with a electrical wiring junction box of plastic construction with a sealed cover assembly. The box shall house the reel solenoid, circuit breaker, and electrical wiring for the rewind control circuit and electric rewind motor power supply. The electrical supply shall be sized for the reel motor for both positive and neutral cables. The electrical supply wiring shall be supplied from the main electrical supply box for high pressure pump skid or module. The supply line to the reel shall have a quick disconnect connection at the main electrical supply box. The hose reel(s) shall be installed by the OEM. The high pressure hose reel shall be supplied by a ½ (12 mm) hydraulic type wire braided flexible hose line. One (1) chrome plate hose roller assembly shall be supplied for protection of the hose during hose removal and rewind operations. REEL MOUNTED ULTRA-HIGH PRESSURE HOSE 150 foot (45 m) length x 3/4" (19 mm) hose shall be installed with threaded couplings. The hose shall have a working pressure of 3,125 psi (215 Bar) NOZZLE -- ULTRA-HIGH PRESSURE One (1) 20 GPM (80 LPM) ultra-high pressure pistol grip fog nozzle shall be provided for the high pressure fog reel. OPTIONS AND MODIFICATIONS: (INSERT OPTIONS AND MODIFICATIONS ONLY IN THIS SPACE) FACTORY TESTING PRIOR TO SHIPMENT The entire pump and the plumbing system shall undergo a complete factory test. These test results shall be provided with shipment. CRATING The equipment shall be properly crated, sealed, and protected for shipment. The crate shall be approximately: 48" (1219 mm) wide x 48" (1219 mm) long x 36" (914 mm) high in size and under 500 lbs. (227 kg) in weight. 5

WARRANTY The PyroLance ultra-high pressure type firefighting system components shall be covered by a one (1) year parts and labor warranty. The installation portion of the warranty shall be covered by the final stage assembler. TECHNICAL MANUAL The ultra-high pressure firefighting system shall be covered by a highly detailed technical manual covering installation, testing, operation, maintenance, and parts. This manual shall have various levels of warnings and caution notices provided. The manual shall be spiral bound with divided sections with a CD electronic version. 07-140-20140307 6